Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹13.4 L+₹1.1 L (9.23%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹16.1 L+₹3.8 L (31.2%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
18 Jan 2020, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Military Engineer Services, Kamptee Cantt - 441 001
REPAIR / REPLACEMNT AND STREET LIGHT, PAINTING LT/HT STEEL TUBULAR POLE AND CONNECTED ITEMS OF DISTRIBUTION SYSTEM IN KAMPTEE AREA AND REPAIR AND MAINT OF DG SET AND STP AT AREA UNDER GE KAMPTEE.
2019_MES_308098_1
8135/E8
Open Tender
Civil Works
Item Rate
180 days
Kamptee
Class E, b (i) and b (ii)
7 documents required · 7 mandatory
₹500
GE Kamptee
₹32,000
Yes
3 Feb 2020
20 Dec 2019
20 Jan 2020
21 Dec 2019
18 Jan 2020
8 Jan 2020
21 Dec 2019 - 6 Jan 2020
Amount
S&F LED street light luminaires of capcity 60 watts with pressure die cast aluminium housing heat resistance toughened glass, IP 66 protection complete with driver,2.5 sqmm 2 core multistranded Aluminium wire for connection from street light fitting to OH line or junction box,and fixing accessories including taking down old unserviceable fitting complete all as specified as directed. Make :- Cat No. LSTP-60-CDL of CG or equiv.in Philips, Bajaj.
S&F LED street light luminaires of capcity 45 watts with pressure die cast aluminium housing heat resistance toughened glass, IP 66 protection complete with driver,2.5 sqmm 2 core multistranded Aluminium wire for connection from street light fitting to OH line or junction box,and fixing accessories including taking down old unserviceable fitting complete all as specified as directed. Make :- Cat No. LSTS-45-CDL-1 of Crompton or equiv.in Philips, Bajaj.
S&F in repair LED flood light fittings with pressure die-cast housing and toughened glass cover 100 watt IP65 protection including driver prewired with 3 core multistranded copper wire 1.5 sqmm from fitting to OH conductor / connector and necessary mounting arrangement as required at site complete all as specified and directed. Make:- Crompton/Phillips / wipro/ Bajaj.
Taking down existing street light fitting, any size, any type (HPSV, HPMV, LED, MH, FTL, energy saving street light fitting, T5 multiple FTL 4x14, 4x24 watt, CFL) from pole / wall after disconnecting connection from pole & repair the same by replacing choke, bipin holder, holders, ignitor, unserviceable flexible wire, tube rod, CFL etc & refixing the fitting on pole / wall including connection with overhead lines / connector & testing etc complete all as specified and directed. Note:- Spares will be measured under relevent items as S&F.
S&F in repair ignitor suitable for 70W to 400W HPSV/MH lamp fitting complete all as specified and as directed. Make:- Phillips / CG / Bajaj.
S&F in repair copper wound ballast suitable for HPSV lamp fitting 70 W complete all as specified and as directed. Make:- Phillips / CG / Bajaj.
S&F in repair copper wound ballast suitable for HPSV lamp fitting 150W complete all as specified and as directed. Make:- Phillips / CG / Bajaj.
S&F in repair copper wound ballast suitable for HPSV lamp fitting 250 W complete all as specified and as directed. Make:- Phillips / CG / Bajaj.
S&F in repairs tubular HPSV lamp 70 W, single ended complete all as specified and as directed. Make:- Phillips / CG / Bajaj / Wipro / Surya.
S&F in repairs tubular HPSV lamp 150 W, single ended complete all as specified and as directed. Make:- Phillips / CG / Bajaj / Wipro / Surya.
S&F in repairs tubular HPSV lamp 250 W, single ended complete all as specified and as directed. Make:- Phillips / CG / Bajaj / Wipro / Surya.
S&F LED driver for 100 W LED street light fittings complete all as specified and as directed. Make:- Wipro/ Bajaj/ Crompton/ Surya or equivalent.
S&F LED driver for 150/200 W LED street light fittings complete all as specified and as directed. Make:- Wipro/ Bajaj/ crompton/ Surya or equivalent.
S&F LED driver for 25/30 W LED street light fittings complete all as specified and as directed. Make:- Wipro/ Bajaj/ crompton/ Surya or equivalent.
S&F LED driver for 45/60 W LED street light fittings complete all as specified and as directed. Make:- Wipro/ Bajaj/ crompton/ Surya or equivalent.
S&F in repair LED Surge protection devices compatible with industrial & Outdoor Led fixture 10 KV Voltage complete all as specified and as directed. Make:- Wipro/ Bajaj/ crompton/ Surya or equivalent.
S&F in repair PVC insulated sheathed twin core flat multi stranded aluminium conductor 2.5 sqmm conductor 1100 volt grade complete all as specified and as directed. Make:- Finolex / Havells / Anchor / Indo Asian.
All as per item No 17.00 above but of size 4.00 sqmm.
All as per item No 17.00 above but of size 6.0 sqmm.
S&F in repairs thermoplastic cable entry junction boxes of size 200 x 160 x98 mm and IP-65 protection level with metric knock out fixed on poles with MS clamps, nuts, bolts and washers including MCB SP, 5-32 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of lugs etc., separate (detachable) gland plate, bakelite connector 4 way 20 amp, dust and vermin proof, front door opening with hinges and locking arrangement, complete all as specified and as directed. Make:- Hansel/ Rittal/ Cape.
S&F of Automatic Street light Switch using NATURE SWITCH for automatic switching of street lights based on LUX level of natural light consisting with Sensor (Natural Switch) along with suitable power contractor, MCB and support terminals should be enclosed in pole/ wall mountable enclosure made out of Rust proof, Electric shock proof, termite proof and FR grade SMC junction Box conforming to IP 54 protction of cpacity 12 KW 3 phase 4 wire (3 separate power contactor) including all accessories and fixing arrengment all as specified and directed.
Supply and fix MCB SP 10-32 Amps, 240 volts, 10 KA capacity complete all as specified as directed.
Supply and fix MCB SPN 10-32 Amps, 240 volts, 10 KA capacity complete all as specified as directed.
Supply and fix MCB TPN 32/40 Amps, 240 volts, 10 KA capacity complete all as specified as directed.
S&F bracket for street light fittings made out of 40 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 30 x 5 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fitting including taking down old unserviceable bracket of any shape and size complete all as specified as directed.
M&L for preparing surfaces of electric poles HT/LT of any type of following sizes including MS cross arms, MS clamps, street light brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint complete all as specified as directed.
Height of HT rail/tubular poles exceeding 7.5 Mtrs upto 9.5 Mtrs above ground leval.
Height of steel tubular poles 7.5 Mtrs above ground level .
M&L for preparing surfaces of electric HT/ LT 4 pole Structures of any make and height of pole up to 10 Mtrs above ground level including MS cross arms, AB Switch pipe, DO Fuse assembly,MS clamps, brackets, bracket clamps, cable protection pipe stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint complete all as specified as directed.
M&L for writing pole No. with letters of size 25 mm height on pole/ plate with Black synthetic enamelled paint complete all as specified and as complete all as specified as directed.
Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables,poles, stay and getting out of excavated material complete all as specified as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified as directed.
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed by EIC.
S&F Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 50mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified as directed. Make:- Dura. Line/Tijaria/REX.
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified as directed. Note :- laying of cable route is same as old cable route .
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip, electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq mm, 4 core including testing after laid and jointed complete all as specified as directed. Make :- Gloster/ Polycab/Havells Note:- Excavation and earth work sand cushioning pipe/ cable protection shall be measured and paid separetely.
All as per ser item No. 34.00 but cable size 10 sq mm 4 core all as specified and as directed.
M&L for Servicing, repair to 125 KVA DG Set (Installed at MH OT of make Kirloskar) including servicing greasing of nipples, draining of unserviceable engine oil by unscrewing drain plug (Engine oil shall be measeured and paid seperatly in respective item) cap, and other moving parts of engine and alternator as per manufacturer’s instructions opening cleaning and re connecting of battery terminals and apply petroleum jelly, checking of coupling and replace it if required, Checking of engine oil leakage if any by replacing gasket, tightening of all nuts and bolts etc, removing radiator completely and cleaning as per manufacturer instructions and refitting the same , check the tightness of fan belts if found loose to be tightened. draining of water accumulated in filter or separate in fuel line including complete fuel tank drying and cleaning re filling of drain out fuel, checking of all electric connections in AMF & LT panel board , switches and contactors etc, checking of free rotation of fly wheel/ shaft of generator and testing to the satisfaction of Engr-in-Charge complete all as specified and directed.
All as per ser item No 36.00 above but DG Set of 200 KVA installed at MSL Power house, Trg shed Msl, MH Kamptee, Treated water pump house, Radial well complete all as specified as directed. Make:- Kirloska/KOEL
All as per ser item No 36.00 above but DG Set of 100 KVA installed at Record Office GRC, Auditorium GRC, Station Exchange complete all as specified as directed. Make:- Ashok Leyland / KOEL/Mahindra
All as per item No 36.00 above but DG Set of 62.5 TO 63KVA (Installed at Shivaji Pump House, APS Tech Block, Tele Exchange Msl, Msl Gp pump house) complete all as specified as directed. Make:- Kirloskar Green/KOEL
All as per ser item No 36.00 above but DG Set upto 30 to 40 KVA installed at APS record, NCC OTA , STP complete all as specified as directed. Make :- Kirloskar Green/KOEL
All as per item No 36.00 above but DG Set of 15 to 25 KVA installed at 'R' Line Pump House, 'T' Line pump house, 8 Major pump house Nagpur, Signal centre GRC complete all as specified as directed. Make :- Kirloskar / Kerala Electricals. Notes for Item No 36 to 41 above:- Rate quoted by Contractor shall deemed to be included following provisions:- (a) Sufficient/required man power employed for the servicing purpose, T&P used and other petty items such as cotton waste kerosene oil, nuts and bolts etc and any other minor items. (b) Replacement of spares will be measured and paid separately as supply only under respective items. (c) If any defect observed during defect liability period the same shall be rectified by contractor without any extra cost to the Govt. The Contractor shall visit each DG Set prior quoting the rate to know the current status of respective DG Sets. No claim what so ever on this account shall be entertained whether he visit the DG set or not.
Supply only in repair lubricant oil filter element with washer suitable for DG set of capacity of 125 KVA Make:- Kirloskar (Installed at MH OT) complete all as specified as directed. (All Make should be as per recommended by manufacturer)
All as per ser item No 42.00 above but DG Set of 200 KVA complete all as specified as directed. Make:- Kirloskar, (Installed at MH , Radial Wall, MSL Power house ,Trg Sed)
All as per ser item No 42.00 above but DG Set of 100 KVA complete all as specified as directed. Make:- Kirloskar, Mahendra Powerol, Ashok Leyland (Installed at Auditorium GRC, Station Exchange, Record Office GRC respectively)
All as per ser item No 42.00 above but DG Set of 62.5 to 63 KVA complete all as specified as directed. Make:- Kirloskar (Installed at Tech Block APS Centre, Msl Pump house, MSL Exchange & Shivaji Pump House)
All as per ser item No 42.00 above but DG Set upto 30 to 40 KVA complete all as specified as directed. Make :- Kirloskar (Installed at , APS record, NCC OTA , STP)
All as per ser item No 42.00 above but DG Set of 15 to 25 KVA Make:- Kerala Electricals (Installed at Signal Centre GRC, R Line Pump House and T Line Pump House, 8 Maj pump house) complete all as specified as directed. Note for item No 42.00 to 47.00 above Make shall be of same as existing or equivalent make as approved by GE.
M&L radiator coolant concentrate complete all as specified and directed.
M&L in repair fuel filter element with 'O' ring suitable for DG Sets 100 to 200 KVA complete all as specified as directed. Make:- Kirloskar, Mahindra, Ashok Leyland complete all as specified and directed.
All as per ser item No 49.00 above but for DG Set of capacity 15 to 63 KVA complete all as specified as directed. Make:- Kirloskar, Ashok Leyland, Mahindra, cummins complete all as specified and directed.
M&L for Lubricant oil 20W 40 complete all as specified and directed. Make : Castrol /HP
S&F battery connection copper lead with 200 Amps rated capacity of approved make complete all as specified as directed.
M&L for distilled water in supplier's packing complete all as specified as directed.
S&F battery terminals as per sample complete all as specified as directed.
M&L for fan belt of suitable sizes as per sample for dynamo/ alternator for the following DG sets:-
All as per ser item No 55.00 but DG Set 200 KVA Make: Kirloskar/Cummins/Mahindra/Ashok Leyland
All as per ser item No 55.00 but DG set 100 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
All as per ser item No 55.00 but DG set 63 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
All as per ser item No 55.00 but DG set 40 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
All as per ser item No 55.00 but DG set 25 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
All as per ser item No 55.00 but DG set 20/15 KVA Make: Kirloskar/Cummins/Mahindra./Ashok Leyland
M&L for rubber hose pipe complete of suitable sizes for DG sets 15 to 63 KVA complete all as specified as directed.
M&L for rubber hose pipe complete of suitable sizes for DG sets 100 to 200 KVA complete all as specified as directed.
M&L for fuel pipe of suitable size for the DG Set 15 TO 200 KVA complete all as specified as directed. Make:- Kirloskar/Mahindra/cummins complete all as specified and directed.
M&L for air filter complete of suitable sizes for DG Set 200 KVA complete all as specified and directed.
All as per ser item No 65.00 above but for DG Set 125 KVA (Installed at MH) complete all as specified and directed.
All as per ser item No 65.00 above but for DG Set 100 KVA (Installed at Records GRC, GRC Auditorium, Station Exchange) complete all as specified and directed.
All as per ser item No 65.00 above but for DG Set 63 KVA complete all as specified as directed. Make:- Kirloskar (Installed at MSL Power house, Shivaji PH, APS Tech block, MSL Trg Shed)
All as per ser item No 65.00 above but for DG Set 30 to 40 KVA complete all as specified as directed. Make:- Kirloskar (Installed at APS Record, NCC OTA, STP)
All as per ser item No 65.00 above but for DG Set 15 to 25 KVA complete all as specified as directed. Make:- Kirloskar (Installed at Signal centre, 8 major Pump, R line, T line)
Supply only automatic voltage regulator (AVR) suitable for the DG Set 40 to 100 KVA Make:- Kirloskar (Installed at MH OT) complete all as specified as directed.
Supply only automatic voltage regulator (AVR) suitable for the DG Set 200 KVA complete all as specified as directed. Make:- Kirloskar/ Mahindra/ Ashok leyland
M&L for taking down old unserviceable self starter from DG set for rewinding of stator, armature and refixed to the existing position after rewinding, including replacement of suitable size bearing complete all as specified as directed.
M&L for taking down old unserviceable Alternator from DG set for rewinding of stator, armature and refixed to the existing position after rewindinding, including replacement of suitable size bearing complete all as specified as directed.
S&F iron hinges suitable for DG set doors complete all as specified as directed. Make : Kirloskar or equivalent
S&F in repair, indicator lamp LED type complete all as specified as directed.
M&L for painting to LT panel board of size not more than 5.0 sqmtr and any capacity with two coats of synthetic enamel paint after cleaning the existing rust and direct with the entire satisfaction complete all as specified as directed.
S&F in repair ammeter complete all as specified as directed.
S&F in repair unserviceable contactor coil of power contactor MNX 300 voltage range 240 v at 50 Hz complete all as specified as directed. Make : L&T or equivalent
M&L for replacement of Digital Meter indicating hrs run ,PF, Voltage, Ampers, Energy consumed complete all as specified as directed.
M&L for replacement of radiator cap with rubber gasket complete all as specified as directed.
S&F in repair unserviceable canopy door lock of suitable size complete all as specified as directed.
S&F broken door glases of DG set canopy complete all as specified as directed.
M&L for replacement of Ignition/ Starter Switch with Key complete all as specified as directed.
M&L for replacement of water temperature meter gauge complete all as specified as directed.
M&L for replacement of oil pressure gauge meter complete as per existing specification complete all as specified as directed.
M&L for replacement of fuel tank cap with locking arrangement complete all as specified as directed.
S&F MCX 32 power contactor for DG set of Make: L&T complete all as specified as directed. Make:- L&T / ABB / Legrand
M&L for cleaning of hypo solution tank, treated water tank & sludge holding tank for 400 KLD STP by cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and draining out spoiled water including using pressure jet pump and suction pump capacity of pool surface complete in all in as specified and directed. Using acid and other suitable methods before filling as required at site complete all as specified as directed. Note:- Quoted rates shall include for using fresh water for cleaning & sludge cutter pump for removing of sludge from tank the stp and de-watering as per the contractor scope arrangement.
M&L for taking down radiator of DG set of capacity from 40 to 200KVA at site and cleanning its fins externaly by air pressure and washed internaly by cleaning agent carefully and fiixing its original position after checking any leakage complete all as specified as directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 32,412.50]
Chinmaya Enteprises
Sharma Electrical and Services
Bidder Name
Sharma Electrical and Services
Paragon Electrotechnics
Chinmaya Enteprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .