Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 CrAccepted-AOC 711 S S T NAGAR RAJPURA ROAD PATIALA PUNJAB MOB 9592400025 | ₹32.0 Cr | L1 | Accepted-AOC Due to lowest bid price |
| 2 | L2₹32.5 CrRejected-Finance | ₹32.5 Cr | L2 | Rejected-Finance Due to high bid price |
| 3 | L3₹36.8 CrRejected-Finance | ₹36.8 Cr | L3 | Rejected-Finance Due to high bid price |
Updated dates
Tender Value
₹38.0 Cr
EMD Value
₹76.1 L
Closing Date
9 Jan 2026, 12:00 pmClosed
Executive Engineer
Provincial Division PWD BandR DAC Complex Sangrur
Construction of Sports Complex at village Kaheru Block Dhuri Distt. Sangrur
2025_CEPW_154902_1
Bid No 74 Dt.28-11-2025
Open Tender
Civil Works - Buildings
540 days
Sangrur
Please refer Tender documents.
7 documents required · 7 mandatory
₹50,000
₹76.1 L
Sangrur
9 Feb 2026
28 Nov 2025
9 Jan 2026
28 Nov 2025
9 Jan 2026
28 Nov 2025
15 Dec 2025
11KV Compact Sub Station 400KVA XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
PIPELINE FOR PUMPING MAIN
Prime Coat @ 0.85kg per sqm Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85kg/sqm complete as per technical clause 502 of MORT&H specifications
Providing and applying tack coat with bitumen emulsion RS using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause 503 of MORT&H specifications
Providing and laying 50mm thick BM
Providing and laying 30mm thick BC
(i) Providing & Laying FIH Global Certified Turf from FIH Certified Turf Manufacturer having pile height of 13mm both recommended for water or sand dressed hockey international tournaments and national level tournaments, maintaining international hockey federation (FIH).Detailed specification attached in BOQ/DNIT. (ii) Providing and laying 15 mm thick rubberized (cast in situ) under layer as per F.I.H. reuirement and specification F.I.H. compettions, including all fittings and net etc all complete as per direction of Engineer in Charge.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
CC 1:2:4 with stone ballast
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position.
Providing & laying 110mm o/d 10kg/cm2 PVC pipe including jointing, testing and fixing of sluice valve,Air Valve including carriage charges along with Sluice Chamber. (50 mtr.)
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge
PIPELINE FOR DISTRIBUTION MAIN
Providing laying, jointing & fixing of uPVC pipes in the distribution including Dismantling of road manually & mechanically and filling the trenches including the provision of sluice valves in the distribution network (330 mtr.
CHLORINATION & DISINFECTION
Extra rate for First Floor
Providing, installing, testing & commissioning one no. Electrically actuated, diaphragm operated, Metering system, chemical dosing Chlorinator, suitable for delivering 0.5 to 0.6 litres of bleching powder solution/ sodium hypo solution per hour under maximum delivering pressure upto 7 kgcm^2 and suction lift not less than 1.5m as per DWSS standard Specification.
PUMP CHAMBER WITH TOILET
Construction of Pump Chamber size 3.70 m x 4.30 m including cost of electric wiring ,with toilet block including carriage complete in all respect Analysis A-1 as per standard drawing D-1-1 to D-1-2.
SOLAR PANEL
CONSTRUCTION OF PAVILLION
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.
PUMPING MACHINERY
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 456 lpm against a head of 90 mtr (17.5 BHP) along with electric panel board consisting of electric appliances such as automatic star delta push button or oil immersed starter, main switch, vm, ampere meter, elcb, shunt capacitor, single phase preventor, indicating lamps, kit-kat etc. complete including cost of C.I. fitting delivery main & V-Notch Haudi.
DEVELOPMENT OF HEADWORKS
Carrage of Matrial
Construction of Pavilion at Guru Tag Bhahadar Collage,Baradwal Athletic Track 400 M at ,Dhuri Distt Sangrur.:- Sub work-1
Centring and shuttering for parapet, fascias and other similar items including edges
Providing, fixing and jointing CPVC Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. Union 25 mm o/d complet
Triple Layer Tanks
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
12.5mm thick cement plaster 1:5.
20 mm thick cement plaster 1:5 in two coats work.
12.5 mm thick cement plaster 1:4.
G.I. tank nipple 40 mm i/d
Providing and fixing on walls face unplasticised rigid PVC rain water pipes single socketed (working pressure 4 Kgf/cm2 ) confirming to IS : 4985 including fixing with MS clamps U-PVC pipes (working pressure 4 kgf/cm2) pipes 100 mm dia
Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including ttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
BlackGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coarsesand)andjointedwithneatcement slurry mixed with pigment atchtheshadeofstone, including rubbingandpolishing including labour for fixing dowel pins and cramps.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Providing & fixing in position Split AC 2 ton of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Including Excavation Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
Construction of embankment with good quality earth obtained from borrow pit including compensasion of earth, bading deenage to sine of work spreading, grading to required slope and compacting to meet requirement table 300-2 as per technical clause 305 of MORT&H specificatioms
Kota stone tile flooring 20mm to 25 mm thick over 20mm thick base of cement mortar 1:4 (1 cement, 4 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing.
110mm o/d pipe of 10 Kgf. / sqcm
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate
Sub head-2 Estate Sewerage System
Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop ..
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS- 2191 Part-I) 1973, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :For fixed portion & Chaukhat
Sub head-3 Providing and fixing of Hockey Field Sprinkler System with boster pumps
Including Excavation Providing, Laying , fixing & jointing of P.V.C.Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
63 mm o/d pipe of 10 Kgf. / sqcm
Sub head-3 Providing and fixing of Hockey Field Sprinkler System with boster pumps
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 5.5 mm thickness.
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two coats)
Applying priming coat with metal primer on new steel or iron work including preparation of surface.With ordinary quality Paint
CONSTRUCTION OF BUILDING OF MULTIPURPOSE INDOOR SPORT'S COMPLEX
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead up
Extra Rate for First Floor
Cement Concrete 1:5:10 with stone ballast of size 40 mm guage.mixing by mechanical means using concrete mixer volumetric type (10.9 b (ii))
ing batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure
Extra Rate for First Floor
Cement Concrete 1:5:10 with stone ballast of size 40 mm guage.mixing by mechanical means using concrete mixer volumetric type (10.9 b (ii))
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (10.16)
Extra Rate for First Floor
Cement Concrete 1:5:10 with stone ballast of size 40 mm guage.mixing by mechanical means using concrete mixer volumetric type (10.9 b (ii))
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i)
Extra Rate for First Floor
Cement Concrete 1:5:10 with stone ballast of size 40 mm guage.mixing by mechanical means using concrete mixer volumetric type (10.9 b (ii))
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. (10.21)
Extra Rate for First Floor
Extra Rate for Second Floor
Centering and shuttering for columns (circular or curved in plain)
Extra Rate for First Floor
Cement Concrete 1:5:10 with stone ballast of size 40 mm guage.mixing by mechanical means using concrete mixer volumetric type (10.9 b (ii))
Centring and shuttering for sides and soffits of beam, beams launchingsgirders bressumers, lintels
Extra rate for First Floor
Extra rate for Second Floor
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra rate for First Floor
Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. (11.6)
Extra Rate for First Floor
Cement Concrete 1:5:10 with stone ballast of size 40 mm guage.mixing by mechanical means using concrete mixer volumetric type (10.9 b (ii))
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement sand mortar in super structure.
Extra Rate for First Floor
Cement Concrete 1:5:10 with stone ballast of size 40 mm guage.mixing by mechanical means using concrete mixer volumetric type (10.9 b (ii))
Extra rate forSecond Floor
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. (10.27)
12.5 mm thick cement plaster 1:5 (15.10)
20mm thick cement plaster 1:5 in two coat work (15.21)
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (13.45)
Providing and fixing in position gratings 150mmx150mm for gully trap. PVC grating
Centring and shuttering for parapet, fascias and other similar items including edges
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. (13.51)
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing (13.13 (i))
Extra Rate for First Floor
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (13.55)
Extra Rate for First Floor
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material (14.3)
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge to be laid below the topping using mechanical mixer for mixing of material (14.11)
Extra Rate for First Floor
Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 12mm to 15mm Slabs sizes above 0.50 sqm (14.74 (iv) (b))
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (14.84)
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing (14.86)
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness and colouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects. (14.142)
Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (14.89 b)
Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications (24.58)
Providing and laying Laminate wooden flooring (Grade AC4 or AC4+ laminates) 6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminum oxide finish that protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacture
Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. (14.135)
Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop ..
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) Float glass panes of 5 mm thickness
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm 5.0mm thick Plate glass (INDIAN)
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4)
Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Finishing walls with Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti ncluding finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:-Above 15.00 mt. Span including the cost for machinery i.e. Hydra cranes etc. for hoisting in position.
Supply & applying Squash court Rebound Wall Hard Plaster system as per international standard. BOUNCE WALL HARD PLASTER shall provided with Silica sand With Cement Mixing 5:1 Total Thickness 10-12mm & Bounce wall Topcoat Plaster is Made 99% Pure Gypsum, Fiber, Marble hard Sand Powder complete in all respects.
Providing and fixing of Made of kiln seasoned treated Mapple Wood Flooring finished with 20 to 21 mm thick, 55 to 90mm width and in random length in tongue and groove shape. The edges of the boards will have a finger lock grove and the bottom side with air pass groove and treated with special anti-termite and water resistant lacquer. The Under Frame: Made of PINE WOOD runners of 70 mm X 45 mm treated with anti-termite solution and fixed on the bottom side with 10mm Or 19mm thick Air-cushion pads by staple at 350 mm c/c. The Installation: The IPS sub-floor to be treated with Acrostic and a vapor barrier of 1- 2 ml.(100 - 200 micron) thick to be placed on the leveled IPS sub-floor before lying the under frame. The runners having air-cushion pads to be placed on the vapor barrier in perfect level at 350 mm c/c in one direction. The surface boards will be screwed to the runners
through the tongue only and will lock the screwed tongue by the groove of the adjoining boards. The ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion gap of 10 mm will be left open between the wooden flooring and the surrounding tiled area/walls. The Finishing: After installation the floor shall be used anti-skid wood filler machine sanded in uniform level and finishing in pu water base polish. the game line marking to be carried out in required colors before applying the finish coat. Warranty:- Flooring shall have Five Years Warranty
Supply & installation of Squash court Sound Board as per WSF Specification.The upper 50mm of the Tin – shall project into the court by not more than 15mm at the top and 45mm at the bottom and shall be shaped so as to deflect any ball striking it . and all edges of the Tin shall be rounded. Below the upper 50mm, for the full width of the court, the Tin shall be constructed in such a manner as to make a distinctive noise when struck by the ball.
Providing and fixing of Made of kiln seasoned treated Tanzanian Teak or equivalent Wooden Flooring BWF Approved finished with 20 to 21 mm thick, 55 to 90mm width and in random length in tongue and groove shape. The edges of the boards will have a finger lock grove and the bottom side with air pass groove and treated with special anti-termite and water resistant lacquer. The Under Frame: Made of PINE WOOD runners of 70 mm X 45 mm treated with anti-termite solution and fixed on the bottom side with 10mm Or 19mm thick Air-cushion pads by staple at 350 mm c/c. The Installation: The IPS sub-floor to be treated with Acrostic and a vapor barrier of 1- 2 ml.(100 - 200 micron) thick to be placed on the leveled IPS sub-floor before lying the under frame. The runners having air-cushion pads to be placed on the vapor barrier in perfect level at 350 mm c/c in one direction. The surface boards will be screwed to the runners through the tongue only and will lock the screwed tongue by the groove of the adjoining boards. The ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion gap of 10 mm will be left open between the wooden flooring and the surrounding tiled area/walls. The Finishing: After installation the floor shall be used anti-skid wood filler machine sanded in uniform level and finishing in pu water base polish. the game line marking to be carried out in required colors before applying the finish coat. Warranty:- Flooring shall have Five Years Warranty
Providing & applying RED colour PU paint on wall surface & wooden flooring surface
Providing and instalation of integrally weighted movable Badminton Posts. The badminton posts shall allows regulation net height to be achieved detachable front upright. It shall be manufacture from 47x47mm square pipe 4mm thick. Base shall made up of strong pipe and shall have weight stock of cast/mild steel 70kg each side. Wheels shall non marking with bearing inside and the wheel shall have 100 mm dia. Complete with rubber feet to protect the playing surface and grip on wooden & synthetic floor. The poles shall either powder coated or spray painted.The net shall made up of nylon material ,suitable for all weather use.The four sides of net shall be covered with white waterproof vinyl tapes.
Supply of set of Moveble Basket Ball Poles having minimum weight 600kg on each side of pole and having adjustable height extension. Each Pole shall consist of Fibre board of size 1.05x1.8mtr and 25mm thick and shall consist of 2 nos dunking rings with net as per Standard Design
Providing and fixing Gym rubber matt 1 mtr x 10 mtr with 8-10 mm thickness including pasting of matt as per specification and satisfaction of engineer-in-charge.
Providing and Fixing multilayer Polyuerthane flooring (10+2mm) consisting of primer on asphault surface, elastic layer SBR matt (5-12mm), Pore sealer(0.1mm), Cast coating (2-3mm), Antiskid multitop (0.5mm) incliding making of Ground Approved by ITF on already laid Flooring System complete in all respect
Providing & fixing of knobset made of stainless steel body, having provision of latch and bolt, 3 nos key set, inside push lock model ETL-101A, Finish SS/PB/AB make-ENOX or any equivalent (Lock should be releasable from out side in case of emergency) as per requirement for unisex toilet for PwD complete as per specifications, Harmonised guidelines for PwD and as desired by engineer-in-charge.
Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS-316 Grade Stainless steel Spider.& bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non star bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
Providing and Fixing of Turbo Fan /Non Electric Exhaust Fan 21"/22" dia to be fitted on roof top/shed etc. with imported polycarbonate body base complete in all respects upto to the entire satisfaction of the Engineer-In-Charge of the work
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/makin
g, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Construction of Plinth protection complete
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.
Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer In-Charge.
Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer. (10.6 b ii)
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 (i))
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material (14.3)
Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material). (14.6)
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. (15.10)
Construction of 200 mtr Track
Cement Concrete 1:8:16 with 40mm guage Stone Ballast Using Concrete Mixture Volumetrictype
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position.
Providing & laying 110mm o/d 10kg/cm2 PVC pipe including jointing, testing and fixing of sluice valve,Air Valve including carriage charges along with Sluice Chamber. (50 mtr.)
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge
PIPELINE FOR DISTRIBUTION MAIN
Providing laying, jointing & fixing of uPVC pipes in the distribution including Dismantling of road manually & mechanically and filling the trenches including the provision of sluice valves in the distribution network (330 mtr.
CHLORINATION & DISINFECTION
Extra rate for First Floor
Providing, installing, testing & commissioning one no. Electrically actuated, diaphragm operated, Metering system, chemical dosing Chlorinator, suitable for delivering 0.5 to 0.6 litres of bleching powder solution/ sodium hypo solution per hour under maximum delivering pressure upto 7 kgcm^2 and suction lift not less than 1.5m as per DWSS standard Specification.
PUMP CHAMBER WITH TOILET
Construction of Pump Chamber size 3.70 m x 4.30 m including cost of electric wiring ,with toilet block including carriage complete in all respect Analysis A-1 as per standard drawing D-1-1 to D-1-2.
SOLAR PANEL
CONSTRUCTION OF PAVILLION
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.
PUMPING MACHINERY
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 456 lpm against a head of 90 mtr (17.5 BHP) along with electric panel board consisting of electric appliances such as automatic star delta push button or oil immersed starter, main switch, vm, ampere meter, elcb, shunt capacitor, single phase preventor, indicating lamps, kit-kat etc. complete including cost of C.I. fitting delivery main & V-Notch Haudi.
DEVELOPMENT OF HEADWORKS
Carrage of Matrial
Construction of Pavilion at Guru Tag Bhahadar Collage,Baradwal Athletic Track 400 M at ,Dhuri Distt Sangrur.:- Sub work-1
Centring and shuttering for parapet, fascias and other similar items including edges
Providing, fixing and jointing CPVC Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. Union 25 mm o/d complet
Triple Layer Tanks
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
12.5mm thick cement plaster 1:5.
20 mm thick cement plaster 1:5 in two coats work.
12.5 mm thick cement plaster 1:4.
G.I. tank nipple 40 mm i/d
Providing and fixing on walls face unplasticised rigid PVC rain water pipes single socketed (working pressure 4 Kgf/cm2 ) confirming to IS : 4985 including fixing with MS clamps U-PVC pipes (working pressure 4 kgf/cm2) pipes 100 mm dia
Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including ttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
BlackGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coarsesand)andjointedwithneatcement slurry mixed with pigment atchtheshadeofstone, including rubbingandpolishing including labour for fixing dowel pins and cramps.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Providing & fixing in position Split AC 2 ton of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Including Excavation Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
Construction of embankment with good quality earth obtained from borrow pit including compensasion of earth, bading deenage to sine of work spreading, grading to required slope and compacting to meet requirement table 300-2 as per technical clause 305 of MORT&H specificatioms
Kota stone tile flooring 20mm to 25 mm thick over 20mm thick base of cement mortar 1:4 (1 cement, 4 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing.
110mm o/d pipe of 10 Kgf. / sqcm
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate
Sub head-2 Estate Sewerage System
Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop ..
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS- 2191 Part-I) 1973, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :For fixed portion & Chaukhat
Sub head-3 Providing and fixing of Hockey Field Sprinkler System with boster pumps
Including Excavation Providing, Laying , fixing & jointing of P.V.C.Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
63 mm o/d pipe of 10 Kgf. / sqcm
Sub head-3 Providing and fixing of Hockey Field Sprinkler System with boster pumps
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Providing and Laying Brick bats in 115 mm layers grouted with sand, including all leads Complete as per Specifications and to the entire specification of engineer-in-charge
Lime Concrete (1:2:8) (0.13 cum lime, 0.26 cum surkhi one cum brick blast) 40mm Gauge
Providing & laying Coal cinder mixed with earth in (70:30) ratio in 10cm layers ramming, watering, & Consolidating with road roller including all leads complete in all respect as per specification and as desired by Engineer in charge.
Precast Cement Concrete KerbsProviding and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications
Providing and laying 50mm thick BM
Providing and laying 30mm thick BC
(i) Providing & Laying FIH Global Certified Turf from FIH Certified Turf Manufacturer having pile height of 13mm both recommended for water or sand dressed hockey international tournaments and national level tournaments, maintaining international hockey federation (FIH).Detailed specification attached in BOQ/DNIT. (ii) Providing and laying 15 mm thick rubberized (cast in situ) under layer as per F.I.H. reuirement and specification F.I.H. compettions, including all fittings and net etc all complete as per direction of Engineer in Charge.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
CC 1:2:4 with stone ballast
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surfaces
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade
Providing and laying 50mm thick BM
Providing and laying 30mm thick BC
(i) Providing & Laying FIH Global Certified Turf from FIH Certified Turf Manufacturer having pile height of 13mm both recommended for water or sand dressed hockey international tournaments and national level tournaments, maintaining international hockey federation (FIH).Detailed specification attached in BOQ/DNIT. (ii) Providing and laying 15 mm thick rubberized (cast in situ) under layer as per F.I.H. reuirement and specification F.I.H. compettions, including all fittings and net etc all complete as per direction of Engineer in Charge.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
CC 1:2:4 with stone ballast
Providing and Laying Brick bats in 115 mm layers grouted with sand, including all leads Complete as per Specifications and to the entire specification of engineer-in-charge
Lime Concrete (1:2:8) (0.13 cum lime, 0.26 cum surkhi one cum brick blast) 40mm Gauge
CONSTRUCTION OF BASKET BALL COURT
Providing/Collection and Laying sand filling laying in 15 cm layers, ramming, watering and consolidating including all leads complete as per specification and as per entire satisfaction of engineer-in-charge.
Cement Concrete 1:5:10 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Providing and Laying Brick bats in 115 mm layers grouted with sand, including all leads Complete as per Specifications and to the entire specification of engineer-in-charge
Lime Concrete (1:2:8) (0.13 cum lime, 0.26 cum surkhi one cum brick blast) 40mm Gauge
Providing & laying Coal cinder mixed with earth in (70:30) ratio in 10cm layers ramming, watering, & Consolidating with road roller including all leads complete in all respect as per specification and as desired by Engineer in charge.
Providing and laying 50mm thick BM
Providing and laying 30mm thick BC
(i) Providing & Laying FIH Global Certified Turf from FIH Certified Turf Manufacturer having pile height of 13mm both recommended for water or sand dressed hockey international tournaments and national level tournaments, maintaining international hockey federation (FIH).Detailed specification attached in BOQ/DNIT. (ii) Providing and laying 15 mm thick rubberized (cast in situ) under layer as per F.I.H. reuirement and specification F.I.H. compettions, including all fittings and net etc all complete as per direction of Engineer in Charge.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
CC 1:2:4 with stone ballast
Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surfaces
Providing & fixing Basketball pole pairs made of MS standard size complete in all respects. (Fixed Type)
Providing and laying 50mm thick BM
Providing and laying 30mm thick BC
(i) Providing & Laying FIH Global Certified Turf from FIH Certified Turf Manufacturer having pile height of 13mm both recommended for water or sand dressed hockey international tournaments and national level tournaments, maintaining international hockey federation (FIH).Detailed specification attached in BOQ/DNIT. (ii) Providing and laying 15 mm thick rubberized (cast in situ) under layer as per F.I.H. reuirement and specification F.I.H. compettions, including all fittings and net etc all complete as per direction of Engineer in Charge.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
CC 1:2:4 with stone ballast
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
CONSTRUCTION OF SKATING RINK
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Providing and Laying Brick bats in 115 mm layers grouted with sand, including all leads Complete as per Specifications and to the entire specification of engineer-in-charge
Lime Concrete (1:2:8) (0.13 cum lime, 0.26 cum surkhi one cum brick blast) 40mm Gauge
Providing & laying Coal cinder mixed with earth in (70:30) ratio in 10cm layers ramming, watering, & Consolidating with road roller including all leads complete in all respect as per specification and as desired by Engineer in charge.
For Providing and Fixing railing 1mtr high made of G.I Pipe 50mm dia vertical post 2mtr center to center, 2 Nos Horizontal member, Wire Mesh 10guage 25mm x 25 mm fixed in 40 mm x 40 mm x 5 mm angle iron fixed with 20 mm x 6 mm flat iron in a frame of G.I Pipe, 50mm thick 200 high Kalwood plank in entire length of the railing embeded in cement concrete complete in all respect.
Providing and laying 50mm thick BM
Providing and laying 30mm thick BC
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Providing and laying 50mm thick BM
Providing and laying 30mm thick BC
(i) Providing & Laying FIH Global Certified Turf from FIH Certified Turf Manufacturer having pile height of 13mm both recommended for water or sand dressed hockey international tournaments and national level tournaments, maintaining international hockey federation (FIH).Detailed specification attached in BOQ/DNIT. (ii) Providing and laying 15 mm thick rubberized (cast in situ) under layer as per F.I.H. reuirement and specification F.I.H. compettions, including all fittings and net etc all complete as per direction of Engineer in Charge.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surfaces
CONSTRUCTION OF TENNIS COURT
Providing and Laying Brick bats in 115 mm layers grouted with sand, including all leads Complete as per Specifications and to the entire specification of engineer-in-charge
Lime Concrete (1:2:8) (0.13 cum lime, 0.26 cum surkhi one cum brick blast) 40mm Gauge
Providing and laying multilayer synthetic acrylic flooring (8 layers) approved by ITF on already laid flooring system complete in all respects and as per specifications laid in handbook on field of play published by SAI
Supply & installation of Squash court Sound Board as per WSF Specification.The upper 50mm of the Tin – shall project into the court by not more than 15mm at the top and 45mm at the bottom and shall be shaped so as to deflect any ball striking it . and all edges of the Tin shall be rounded. Below the upper 50mm, for the full width of the court, the Tin shall be constructed in such a manner as to make a distinctive noise when struck by the ball.
Applying priming coat with metal primer onnew steel or iron work including preparation ofsurface.
Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:-Above 15.00 mt. Span including the cost for machinery i.e. Hydra cranes etc. for hoisting in position.
CONSTRUCTION OF VOLLEY BALL COURT
Providing & fixing Volley ball poll pairs made of MS standard size complete in all respects
Providing & fixing Volley ball net of polyster white colour size 9.5m x 1.00 m, mesh size 100mm x 100mm complete in all respects
CONSTRUCTION OF BADMINTON COURT
Providing & fixing Badminton Pole pairs made of MS and polyester net (movable) standard size complete in all respects
CONSTRUCTION OF KHO KHO COURT
Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications
CONSTRUCTION OF DRAINING SYSTEM
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Earth work upto 1.5 m. Depth for All classes of soil except rocky (CSR 28.2 (a)(i))
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.
Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type (CSR 10.9 bii)
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.(CSR 10.16)
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete (CSR 18.18)
ing batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal (CSR 29.60 c)
Constructing brick masonry manhole in cement mortar 1:5 ( 1
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. (10.21)
Centering and shuttering for columns (circular or curved in plain)
Centring and shuttering for sides and soffits of beam, beams launchingsgirders bressumers, lintels
Extra rate for First Floor
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. (11.6)
cement : 5 coarse sand ) with RCC core wall between masonary, R.C.C. top slab 20mm thick using M-20 mix, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps ncluding RCC cover with frame internal imensions.complete as per standard design. (In water logged area) Inside size 75x120 cm and 120 cm deep (CSR 29.56 a)
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement sand mortar in super structure.
cement : 5 coarse sand ) with RCC core wall between masonary, R.C.C. top slab 20mm thick using M-20 mix, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps ncluding RCC cover with frame internal imensions.complete as per standard design. (In water logged area) Inside size 75x120 cm and 120 cm deep (CSR 29.56 a)
Extra rate forSecond Floor
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. (10.27)
12.5 mm thick cement plaster 1:5 (15.10)
20mm thick cement plaster 1:5 in two coat work (15.21)
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (13.45)
Providing and fixing in position gratings 150mmx150mm for gully trap. PVC grating
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. (13.51)
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (13.55)
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer -in-charge. (CSR 28.94)
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material (14.3)
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge to be laid below the topping using mechanical mixer for mixing of material (14.11)
Extra Rate for First Floor
Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 12mm to 15mm Slabs sizes above 0.50 sqm (14.74 (iv) (b))
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness and colouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects. (14.142)
CONSTRUCTION OF SWIMMING POOL BUILDINGS
Cement concrete 1:5:110 With brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion and chawkhats
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) Float glass panes of 5 mm thickness
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm 5.0mm thick Plate glass (INDIAN)
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4)
Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type
Providing and Fixing multilayer Polyuerthane flooring (10+2mm) consisting of primer on asphault surface, elastic layer SBR matt (5-12mm), Pore sealer(0.1mm), Cast coating (2-3mm), Antiskid multitop (0.5mm) incliding making of Ground Approved by ITF on already laid Flooring System complete in all respect
Providing & fixing of knobset made of stainless steel body, having provision of latch and bolt, 3 nos key set, inside push lock model ETL-101A, Finish SS/PB/AB make-ENOX or any equivalent (Lock should be releasable from out side in case of emergency) as per requirement for unisex toilet for PwD complete as per specifications, Harmonised guidelines for PwD and as desired by engineer-in-charge.
Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS-316 Grade Stainless steel Spider.& bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non star bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
Providing and Fixing of Turbo Fan /Non Electric Exhaust Fan 21"/22" dia to be fitted on roof top/shed etc. with imported polycarbonate body base complete in all respects upto to the entire satisfaction of the Engineer-In-Charge of the work
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/makin
g, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc when curved.
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
Extra Rate for First Floor
Providing and laying vitrified floor tiles in different size in light colour shades made using Full Body Technology (thickness to specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand ), complete. (Full body vitirified tiles have pigment in entire body/ thickness of which make chips and scratches less noticeable and na ideal choice for high traffic zones) Size 600x600 mm CSR 14.115 a
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 161mm x 60mm with 40 mm wide double rebate weighing 4.05 kg per meter. For fixed portion and chawkhats
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate.
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect 5.0mm thick Plate glass (INDIAN)
Deodar wood doors shutter windows shutter including hinges, screw and cords etc. Complete fixed in position 35mm thick
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Construction of Swimming Pool
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Waterproofing of wet areas (Concrete/ Masonary Surface ) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating ( DR. FIXIT FASTFLEX / Equivalent ) to provide tough film build up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning, washing and removing dust,dirt and loose particles from concrete / masonary surface complete in all respects.
Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mmsand or stone filling.
Conglomerate floor 25mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
CONSTRUCTION OF TOILET BLOCK
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement concrete 1:8:16 With stone aggregates 40mm gauge mixing by mechanical means using concrete mixer volumetric type
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Shuttering for faces of concrete foundations and foundation beam & plinth beam (For RCC)
20mm thick cement p
laster in damp proof course 1:3 with two coats of bitumen at 1.65Kg. Per sqm laid hot and sanded
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above Plinth Level
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure.
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Centering and shuttering for sides and soffits of beam, launchings girders, bressumers, lintels.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete
Extra for work done in additional storey upto 4 meter above the top of structural roof of lower storey for Brick work/ Concrete Block/ Clay Block.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Cement concrete 1:2:4 gola 10cm x 10cm
Earth filling under floors with surplus soil conatining more than 40% taking outside the premises in 15cm layers including ramming, watering and consolidated lead upto 1000 meters
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
12.5 mm thick cement plaster 1:4
Cement Concrete 1:8:16 with 40mm guage Stone Ballast Using Concrete Mixture Volumetrictype
Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
20mm thick cement plaster 1:4 in two coat work
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality
Providing and fixing 1st quality ceramic glazed wall tiles 310 x 450mm
Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (10.16)
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Reinforced cement concrete M-25 mechanically batch mixed us
ing batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure
Centring and shuttering for Columns ( Square or Rectangular or plygonal in plain) in superstructure
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 18.18
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. 11.6
12.5mm thick cement plaster 1:5. (15.10)
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
20 mm thick cement plaster 1:5 in two coats work. (15.21)
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications
Iron grated doors, including pintle hinges & arrangements.
Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 35mm thick
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete 300mm x 16mm
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications (CSR 24.7)
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats
Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.
Precast Cement Concrete Kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications
Iron grated doors, including pintle hinges & arrangements.
Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
LANDSCAPING
CONSTRUCTION OF BOUNDARY WALL
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts
Supplying and planting permanent shrubs in prepared pits and watering.
Cement concrete 1:4:8 With brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type CSR 10.10 b ii
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.
Dismantling of brick work in cement sand mortar / lime mortar including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 metre (By Mechanical Means)
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..
Credit Of Bricks
Credit Of Brick Bat
CONSTRUCTION OF PARKING
Providing, laying, spreading and compacting stone aggregates of Grading I to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8- 10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (CSR 24.11 (i) )
Precast Cement Concrete Kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code : 15658(2006)
Planting seasonal flower in beds Planting seasonals at flowering stage in beds including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting at 20cm distance from plant to plant and row to row.
Edging of paths/ beds with bricks/tiles laid dry, including required excavation, refilling, consolidating with hand and spreading surplus earth neatly within lead of 50 m Brick inclined at 60 deg to horizontal
400 mtr & 8 Lane Synthetic Track
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, as required for IAAF approved Track With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 - (150mm thick layer)
Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85kg/sqm complete as per technical clause 502 of MORT&H specifications
Providing and laying dense graded bituminous macadam 50mm to 75mm thick with Continuous type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 4.5%, laying with a Paver Finisher Mechanical to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 505 of MORT&H specifications 24.20 b
Tack Coat @ 0.40kg per sqm Providing and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical specifications 24.16 b
Providing and laying bituminous concrete on the prepared surface with specified graded crushed stone aggregate for wearing course including loading of aggregate with FE loader and hot mixing of stone aggregate, filler and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed material with paver finisher fitted with electronic sensing device to the required level and grade and rolling by road roller as per IAAF Approved track specifications, to achieve the desired density, but excluding the cost of primer / tack coat. 30 mm compacted thickness with bitumen of grade VG-30 @ 5.4% and lime @ 2% (percentage by weight of total mix)
Providing and laying Synthetic Athletic Track of FULL PUR with FULL EPDM System having a minimum thickness of 15mm with valid product approval certificate and laboratory test certifi
cates from World Athletics (IAAF) for minimum 15mm thickness, including markings on the surface all complete as per requirements/ specifications laid down by World Athletics (IAAF) and Class-I certification. The agency should have supplied and installed at least 5 World Athletics (Earlier IAAF) Certified class 2 facility track Cast in situ in the last 5 years, out of which one should be Full PUR Full EPDM with the same proposed product/brand including complete sub base in India from the last day of previous month from tender floatation in their individual capacity and not as a Joint Venture. The proposed product should be certified by World Athletic (Earlier IAAF) for a minimum thickness of 15MM for Class I Track. The proposed product/brand should be of European/American/Australian origin only.
Supply and fixing of Track field equipment: As per IAAF approved. Long jump/ triple jump Take off board- As per IAAF approved
Construction of sand filling Jumping pit for long jump/ triple jump. As per IAAF approved.
Construction of steeple chase water jump pit at inside the North D portion . As per IAAF approved.
Pole -vault box with cover
Shotput throwing circle of dia 2.135m
Stop board for shotput circle
Discuss throwing circle of dia 2.50m
Hammer throwing circle of dia 2.50m
Hammer throwing cage incl. Poles and net.
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal (CSR 29.60 c)
Centering and shuttering for columns (circular or curved in plain)
Discuss throwing cage incl. Poles and net.
Aluminium kerbing-400m standard track
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.Earth work upto 1.5 m. Depth for Ordinary soil having gravel upto 40%
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, C57testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 200 mm o/d pipes
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.dia 75mm o/d pipe of 10 Kgf. / sqcm
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 90x150 cm and 120 cm deep
Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type.
First class burnt brick work laid in cement sand mortar 1:5 in foundation & Plinth.
12.5mm thick cement plaster 1:4.
Reinforced cement cocrete M-25 Mechnicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrator by needle vibrator but excluding steel reinforcement, centering and shuttering in foundation and plinth.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer -in-charge.
Repair Work
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.Doors of area 3 sqm and below. Doors of area 3 sqm and below.
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Windows of area 3 sqm and below
Dismantling cement conglomerate floors 25mm to 50mm including concrete base.
Dismantling brick or flagged stone flooring including concrete base.
Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Cement concrete 1:8:16 with stone agreegate 40mm gauge mixing by mechanical means using concrete mixer vol. type
Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge.
Kotah stone tile flooring 40mm to 50mm thick over 12.5 mm thick base of cement mortar 1:3 (1 cement; 3 sand) laid and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:-Glazing, wire gauge and grill will be paid as per respective items)
Providing and fixing glass panes with nails and putty and wooden strip complete n all respect Glazing area above 0.09 sqm.
Factory manufac
tured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973.Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- (iv) 35mm thick
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 35mm thick
Sports Grounds/Courts (Hockey Ground, Athletic Track 200mete
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt). For shutter area above 0.50 sqm
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing surface to required finish complete.
Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
Scraping of white wash or color wash.
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Scraping of cement plaster
Cement rendering on plastering 1mm thick.
12.5 mm thick cement plaster in CM 1:4
clearing ang grubbing road land
Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm (+ 0.05 %) thick
25mm i/d Brass Ball valves
Stone (building or pitching) Sand, Earth, Fly Ash, Bajri, Shingle, Spalls, Brick bats, Brick ballast and Stone metal. Loading Unloading.
Scraping of cement plaster
Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm (+ 0.05 %) thick
Earth,Surkhi, Sand, Earth, Fly Ash, Bajri, Ballast, Stone boulders, Kankar and building rubbish, Earth. Carriage for 5 Km.
Ceiling Rose (Flush Piano type)
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Overall size 1sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point (With fan box)
Wiring light point
Wiring call-bell point
Wiring 6Amp. wall socket point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:-
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
Overall size 10sq.mm (4Core) Un-armoured (Loose)
Overall size 16sq.mm (4Core) Un-armoured (Loose)
Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
On Load Change Over Switch Four Pole 160amp., 415volts
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
Overall size 95sq.mm (3½ Core) Un-armoured (Loose)
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
Wiring light point with double control switches.
HEAVY GAUGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan.
MCB Triple Pole 50, 63amp. (10kA, Curve-C)
Cable End Box for TPN Vertical 4/8/12Way
MCB Four Pole 50, 63amp. (10kA, Curve-C)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy Gauge PVC Conduit
Pipe 25mm dia. (On Surface)
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed)
COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:
Additional Length 20mm x 3mm thick Copper Tape
GALVANIZED IRON PIPES AND G.I. EARTHING Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-
GI Earth rod 20 mm dia., 3 mtr. Long
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Double Pole 40amp. (10kA, Curve-C)
Overall size 16sq.mm (Un-sheathed)
Supply and erection of RCBO (Residual Current Breaker Overload) for Earth leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61009 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Triple Pole 40amp. (10kA, Curve-C)
RCBO Four Pole 63amp., Sensitivity 30mA
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
SP&N Double Door Distribution Board 12 way each
TP&N Horizontal Double Door Distribution Board 4 way each
TP&N Horizontal Double Door Distribution Board 6 way each
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-
TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB upto 125amp.)
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
Cable End Box for SPN 12 Way
MCB Four Pole 40amp. (10kA, Curve-C)
MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
Cable End Box for SPN 12 Way
Cable End Box for TPN 4 Way
Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm
Cable End Box for TPN 6 Way
ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): LT PANELS: Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floo
r mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Aluminium thimble cable Core size 10 -16sq.mm
LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm) (FOR PAVILION BUILDING) (Main Panel Incomer:- MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=2 no., MCCB 125Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=1 no., On Load Change Over swtich 160A FP = 1 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCB's 40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm)(FOR SWIMMING POOL) (Main Panel Incomer:- MCCB 125Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=4 no., MCCB 40Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=2 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm)(FOR SPORTS HALL) (Main Panel Incomer:- MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=5 no., MCCB 40Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=2 no. ,On Load Change Over swtich 160A FP = 1 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
MCCB's (FOR PANELS & SHEET ENCLOSURE): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.)
Double Walled Corrugated HDPE Pipe 90/ 76mm (Outer/ Inner dia.)
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Aluminium thimble cable Core size 50sq.mm
Aluminium thimble cable Core size 70sq.mm
Aluminium thimble cable Core size 95sq.mm
GI PIPE POLES: Supply and erection of G.I. pipe ‘A’ quality of suitable length and dia. confirming to IS:1239 (Part-I) 1979, including fixing up to a given depth below G/L, the hole of excavation about 30cm dia. and given depth to be filled in up to 15cm below G/L with 1:2:4 cement concrete including painting of pole with two coats of approved aluminium paint as required:-
G.I. Pipe Pole 6.1 metre Long, Dia. 80mm, Planting Depth 120cm with Pit Depth 135cm.
CEMENT CONCRETE MUFFS: Making of cement concrete muff of overall size 450mmdia., suitable length (15cm below ground level) with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole/ GI pipe pole.
The outer surface of the muff shall be finished with 1:2 cement plaster with two coats of white snowcem complete in all respect as approved and desired by the Engineer in-Charge at site:-
Cement Concrete Muff of Overall Size 450mm dia., 60cm long
LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS: Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-
SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement
M.S. FLAT/ CHANNEL BRACKETS:
Supply and erection of MS sheet metal box (1mm thick) of length 1225mm, breadth 400mm, height 425mm with MS angle iron 40mm x 40mm x 5mm frame at the base of the box for storing metal halide flood light fitting in it. Sheet metal should have top portion hinged with 6" (6 inch) hinges and divided into equal 8 compartments with sheet 1mm thick.
Supply and erection of LED batten 20watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary
Supply and erection of LED batten 40watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Supply and erection of Recessed mounted 18watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of LED Surface type downlighter 18watt LED (including constant LED driver) with High quality Presure die cast aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Recessed mounted 12watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of LED Recessed downlighter 6watt LED (including constant LED driver) with High quality Presure die cast aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
Supply and erection of Recessed mounted 36watt LED 2x2 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers and hanging GI wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of ventilation fan 200mm 8 Inch including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Heavy duty Exhaust Fans 300mm 900RPM with aluminium louver shutter Canon of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
Supply and erection of Heavy duty Exhust Fans 450mm sweep 900RPM complete with aluminium louver shutter Canon Make, double ball bearing, longer life including flexible wire & petty material etc.
Cable End Box for TPN 6 Way
for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Ceiling Fans 1200 Sweep 48" (3 star) having two ball bearing including flexible wire & petty material etc.complete in all respects as appd. and desired by the Engineer in-charge at site.
Supply and erection of Wall fan 400mm Swing 16 Inch high speed including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Air Circulator Wall Fan 600MM Metallic Body, 24" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and Erection of LED High Bay Light 150watt (including LED driver) with pressure die cast aluminium housing with control gear ( with IP 65/ IP 66 protection), CRI Minimum 70, CCT >5700K, toughened glass fitting, LED fixture minimum 120 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection (as per BIS standards) , surge protection 10kv and above (as per (IS/IEC standards) wattage of each LED High power LED of 1 watt to 5 watt with mandatory modular lenses, input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and Erection of LED High Bay Light 250watt (including LED driver) with pressure die cast aluminium housing with control gear ( with IP 65/ IP 66 protection), CRI Minimum 70, CCT >5700K, toughened glass fitting, LED fixture minimum 120 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection (as per BIS standards) , surge protection 10kv and above (as per (IS/IEC standards) wattage of each LED High power LED of 1 watt to 5 watt with mandatory modular lenses, input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of LED Flood Light 350watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Aluminium thimble cable Core size 10 -16sq.mm
Aluminium thimble cable Core size 25 -35sq.mm
Aluminium thimble cable Core size 120sq.mm
Overall size 35sq.mm (3½ Core) Un-armoured (Loose)
Overall size 240sq.mm (3½ Core) Un-armoured (Loose)
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:-
Overall size 2.5sq.mm (10 Core)
Earthing with 25mm x 5mm Copper Tape (upto 14Metre in Length)
COPPER EARTHING (Upto 23 metre in Length): 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 19.50 metre (63.96 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 23metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 18metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 25mm x 5mm Copper Tape (upto 23Metre in Length)
Additional Length 25mm x 5mm thick Copper Tape
Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.)
Double Walled Corrugated HDPE Pipe 120/ 103.5mm (Outer/ Inner dia.)
XLPE INSULATED HT ARMOURED CABLES (LOOSE): Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid loose in the existing trench or pipe:-
HT Cable Overall size 50sq.mm (3Core)
S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:-
Heat Shrinkable End Termination for cable size 50-95 sq. mm, 3Core (Indoor Type)
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Supply, Erection, Testing and Commisioning of 12kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type Extenable 1no's VCB (Vacuum Circuit Breaker) switch board unit 800/630 Amp. totally factory assembled which includes 800/630 Amp. Vacuum Circuit Breaker for 1 no. Incoming cum Out goings VCB 630Amp. 'Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of Min. 21kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance
(i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 50 opeartions or more VCB parameters are as below: (a). Rated Voltage: 12kV (b). Rated short circuit breaking current withstand : Min. 25kA for 3sec. (c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak (d). Rated insulation voltage( Power frequency withstand) : Min. 28kV (e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO (f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz) (g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) VCB incorporating mechanical as well as electrical ON/OFF indiaction "OFF" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door. Incomer shall consist of: (a). Cast Resin CT's 11kV : 150-70/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Cast Resin PT's 11kV : PT Ratio 11kV/√3 / 110V/√3 / 110V/√3, Class 1, Class 0.5 Burden 50VA
11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Switch board unit 800/630 Amp. which includes 1 No. 800/630 Amp. Vacuum Circuit Breaker for Incomer cum Out going feeder with inbuilt powerpack. complete in all respects as approved and desired by the Engineer-in-charge at site. Besides this the manufactures should have NABL accredited labortary certificate. The Supervision,Inspection & testing at Manufactuers site(By department)
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
Supply, Erection, Testing and Commisioning of HT 11kV Package Substations 400KVA is completely self-contained Solution for power distribution that includes Pre fabricated outdoor duty enclosure, high voltage switchgear, distribution transformer, low voltage panel and accessories such as power factor improvement equipment, control and protection equipments, all providing a cost effective. The complete unit shall be installed on a substation plint (base) as outdoor substation. Package substation shall have the following equipments: 11kV Switchgear: 11 kV, 3 Phase, SF6 compact switchgear panel with 11kV Load break switches controls incoming-outgoing feeder cables of 11kV ring main distribution system and Vacuum circuit breaker (VCB) as protection to the transformer. The Load break switch, Vacuum circuit breaker, Bus bars should be mounted inside a sealed robotically welded stainless steel tank enclosure. The operating mechanism of switches and breakers shall be outside the SF6 tank and accesible from front. The tank should be filled with SF6 gas at an adequate pressure. The degree of protection for gas tank should be IP67. There shall be provision for filling the SF6 gas at site. Stainless steel gas tank shall confirm to the sealed pressure system and ensure the gas leakage to 0.1% per year as per IEC 60298. The Panels shall be tested for IAC level of min. 21kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 40 opeartion. Load break switch parameters are as below: (a). 11kV, 3Phase HT manually operated Load break switches 630Amp., copper busbars with integral earth switch having ON/OFF/EARTHED indiaction, live cable indiaction cable termination bushing suitable for 300sq mm XLPE cable. (b). Type: Load breaking and fault making in SF6 tank (c). Fault making capacity : 52.5kAp (d). Operating Mechanism: Operating handle with ON, OFF, Earth positions with arrangement for padlocking in each position
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring 6Amp. wall socket point
Wiring 6Amp. Plug control comprising wall socket point
Wiring fan point (With fan box)
Wiring light point
VCB parameters are as below: (a). Rated Voltage/ PF withstand/ Impulse withstand: 11kV/28kV/52.5kVp (b). Rated short circuit breaking current withstand : Min. 21kA for 3sec. (c). Operating mechanism: Trip free & free handle type mechanically operated indication & pad locking (d). Cast Resin CT's 11kV : 100-50/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (e). Digital Ammeter : Applic
Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
On Load Change Over Switch Four Pole 160amp., 415volts
Transformer: 11KV/433V Distribution Transformer, Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type double wound with copper conductor cnforming to IS:1180 (2021) Level-2 ( As Latest Amedments -4) & IS: 2026, vector group Dyn11 suitable for packaged substation housed in a enclosure with corrugated tank arrangement hermeatically sealed. Transformer parameters are as follows: (a). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%. (b). Permissible Temp. Rise of Oil: 40°C (c). Permissible Temp. Rise of Winding 45°C (d). Magnetic Core: Prime grade of M4 or better (e). System Highest Voltage :- 12kV at the HV side (f). Terminations: Cable Box on HV & LV Side (g). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp Enclosure for PSS: Outdoor type enclousre shall be made of 2mm thickness of galvanised sheet steel tropicalised to meet indian weather conditions including all the partition sheets and doors. The enclosure shall be corrugated type wall design for better heat dissipation, provinding robust construction and enclousre should have IP54 degree of protection for HT & LT switchgear compartment & IP 23 protection for transformer compartment. the base of the enclosure shall be of 4mm thickness hot dip galavanized sheet steel to ensure rigidity for easy transport & installation. The entire package substation shall be factory assemble & factory fitted. Each compartment should be provided with the door and pad locking arrangement. The unit shall be tested for internal arc fault test to the tune atlest 20kA for 1 second as per latest IEC 62271-202. Interconnection & Earthing: Interconnection between HT switchgear & transformer using screened covered aluminium XLPE single core cable & interconnection between transformer & LT switchgear using aluminium busbars with copper flexibles. Internal earthing connections by 50x 6mm G.I strips.
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
LT switchgear: (a). LT switchgear with 433V suitable ampere rating Aluminium busbars with 100% neutral (b). 1 No. MCCB/ ACB FP microprocessor based for O/C, S/C & Integrated E/F release type for incomer according to the KVA rating of the transformer Metering compartment: (a). 1 No.Digital multi functional meter class1.0 Package Substation 11kV HT Switchgear with 1way RMU (RRL), consisting of 2 Nos. manually operated Load Break Switch 630 Amp., 1 No. manually operated VCB 630 Amp., 11KV/433V, 400kVA ONAN type transformer, 1 No. ACB 800Amp., FP, 50KA microprocessor based. The Concerened contactor shall be provide the detailed drawing of panel with complete specification and approved from the Engineer in charge at site.
Designing, Supplying, installation, testing & commissioning of Oudoor cubical type Designed Indoor PTTA LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 60439-1&2 -Partilaly Type Tested panel with IP 65 (outdoor type).PTTA Panel shall be tested for all type test as per IEC 60439-1&2 & IEC61641 with aluminum busbar,OEM shall submit the all type test reports during drawing approval. (Dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system,IP65 and minimum 50kA. The Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 60439-1&2 and IEC 61921. Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet,,conforming to IS:8623. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. The Panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel.The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7 tank Powder coated process should present in company pemises) after necessary putty work . The Concerened contactor shall be provide the detailed drawing of panel with complete specification and approved from the Engineer in charge at site.
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Cable End Box for TPN Vertical 4/8/12Way
Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed)
COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:
eports. The Supervision,Inspection & testing at Manufactuers site(By department). The Concerened contactor shall be provide the detailed drawing of panel from company designed attested and submitted to department for approval with complete specification and approved from the Engineer in charge at site. Bus Bar :- 1000A, TPN Aluminium Busbar suitable for with standing fault level of 50KA with heat shrinkable coloured sleeves i/c SMC/DMC bus bar supports at required intervals. (Current density shall be maximum 1.3 A/sqmm) The Cost of ACB, MCCB, MCB, C/O Switch etc included & Detail of ACB/MCCB's to be installed in the cubical panel Enclosure as per following .
Main LT Panel (OUTDOOR TYPE) :- Main Incomer:- 1. ACB 630 Amps. FP Icw=50kA for 1 sec Microprcoessor EDO based release with LSIG protection = 1No. Outgoings:- 1. MCCB 250Amp. Thermal magnetic releases (adjustable overload and short circuit rating) with overload, Short circuit protection & rotary handle , FP, 25KA = 1No. (For APFC) 2. MCCB 160Amp. Thermal magnetic releases (adjustable overload and short circuit rating) with overload, Short circuit protection & rotary handle , FP, 25KA=3 no. 3. MCCB 125Amp. Thermal magnetic releases (adjustable overload and short circuit rating) with overload, Short circuit protection & rotary handle , FP, 25KA=3 no. 4. MCCB 100Amp. Thermal magnetic releases (adjustable overload and short circuit rating) with overload, Short circuit protection & rotary handle , FP, 25KA=8 no. 5. MCCB 63Amp. Thermal magnetic releases (adjustable overload and short circuit rating) with overload, Short circuit protection & rotary handle , FP, 25KA=2 no., 6. On Load Change Over switch 630A FP = 1 no. Note:- The Panel cost includes cost of fabrication of panel including cost of ACB, MCCB & Change over)
TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB upto 125amp.)
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
Cable End Box for SPN 12 Way
Cable End Box for TPN 4 Way
Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm
Supply , fixing , connecting and testing of Factory Manufactured / Company TTA APFC Panel with 7% reactor of capacity 125 KVAR @ 440V along with Capacitors 525V. The stage ratings shall be 1 X 50 KVAR + 1 x 25KVAR + 2 x 12.5KVAR + 1 x 10KVAR+ 3 x 5KVAR The incomer of Each Capacitor Bank should having MCCB 36/25ka as per standards , Ics = 100% Icu & Power Contactors of same rating. The APFC Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 61439-1&2 and IEC 61921. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. As equipment shall be comprising of the following:- 1. Insulated bus bar pan assembly made from copper and rated of 400 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. 2. The incomer of the APFC Panel shall be a 250/320 Amp MCCB / 36KA/4P/TP Microprocessor based LSIG protection. The MCCB shall be of certified design confirming to IEC 60947-1,2 & 3., Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier. 3. Capacitor Units : The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993,13341-1992 & IEC -60831-1&2.
4. Short-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 50kAThe MCCB shall be of certified design confirming to IEC 60947-1,2 & 3. 5. PF Regulator : Advanced Range PF Regulator shall have 6 steps with a LCD Display, Voltage Range : 90V - 550V, 50 / 60Hz, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326. 6. Stage Contactor & Reactor : The electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1. The de-tuning reactors shall be connected in series with each capacitor stage and shall be of iron cored type.The Detuned Reactor Should be equipped with Thermal Switch inside the Winding which should cut-off the respective contactor in case of Over-temperature. Tolerance of reactors shall not exceed +/-3% of rated value.
Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
7. Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted along with the offer. Note:- Manufacturer/Company of Panel should be CPRI Approved & ISO certified (Manufacturer / Company workshop as per ISO9001:2015 standerd). The warranty period will be start after complete commissioning. The Supervision,Inspection & testing at Manufactuers site (By department in contractor scope). The Concerened contactor shall be provide the detailed drawing of panel from OEM designed attested and submitted to department for approval with complete specification in all respects as approved and desired by the Engineer-in-charge at site
Overall size 10sq.mm (3Core) Un-armoured (On-Surface)
Making of Cement concrete foundation of size 15' X 8' X 2' high for Panels & CSS. The foundation start with Earth work in excavation 16' x 10' in foundations, Cement Concrete 1:5:10 with 40mm gauge stone agreegate mixing by mechanical means using concrete mixer volumetric type of size 15'x10'x0.75' , First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth size 15'x1.125'x 2' , Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres sizes 15.75'x5.75'x2', Shuttering for faces of concrete foundations and foundations, Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. sizes 15'x8'x0.5', Cold twisted deformed (Ribbed/for Steel Bar) Bar Fe 500 grade as per IS 1786-2008 complete in all respect as per site requirement and as desired by the Engineer in charge.
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Aluminium thimble cable Core size 10 -16sq.mm
LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm) (FOR PAVILION BUILDING) (Main Panel Incomer:- MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=2 no., MCCB 125Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=1 no., On Load Change Over swtich 160A FP = 1 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
Centring and shuttering for columns (Square or rectangular or
Supply and erection of providing and fixing of fire bucket with MS hook stand complete in all respect as desired by engineer in charge of the work.
Supply and erection of Non skkid rubber mat ISI 1000mm x 2000mm x 12mm for 11 KVA supply complete in all respect as desired by engineer in charge of the work.
Supply and erection of Medical Kit complete in all respect as desired by engineer in charge of the work.
Supply and erection of Danger Plate 11000 volts and 440 volts size 200mm x 150mm complete in all respect as desired by engineer in charge of the work.
Supply of 11 KV HT Glovees complete in all respect as desired by engineer in charge of the work.
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.)
Overall size 2.5sq.mm (50/0.25mm), 3Core
8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm
and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:
poly gonal in plain)
Cubical Size 1400mm high, 1200mm wide and 500mm deep with platform dimensions 1300mm x 600mm x 450mm
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)
Additional Length 25mm x 3mm thick Copper Tape
Supply, installation, testing & Commissioning of 5 meter Steel Poles are made out of galvanised mild steel tubes having (140mm dia at bottom and 75mm dia at top) with cast iron and Emlishment -Q4.The pole are primer coated and painted with polyurethane paint. The pole are suitable for single/double triple/four side post top/drop down luminaries.The pole has service window at the bottom compresing four way 25Amp connector terminal and a MCB rating of 6A . Pole has a mild steel plate having four number mounting hole as per drawing provided by manufacturer and can be mounted with four number anchor bolt. Coating on pole should have minimum DFT of 90 microns. Total height of the lighting pole shall be 4000 mm without foundation bolt as recommended by pole manufatures company. Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply and erection of LED batten 40watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:
Aluminium thimble cable Core size 240sq.mm
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring call-bell point
Wiring light point
Overall size 95sq.mm (3½ Core) Un-armoured (Loose)
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
VCB parameters are as below: (a). Rated Voltage/ PF withstand/ Impulse withstand: 11kV/28kV/52.5kVp (b). Rated short circuit breaking current withstand : Min. 21kA for 3sec. (c). Operating mechanism: Trip free & free handle type mechanically operated indication & pad locking (d). Cast Resin CT's 11kV : 100-50/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (e). Digital Ammeter : Applic
Designing, Supplying, installation, testing & commissioning of Oudoor cubical type Designed Indoor PTTA LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 60439-1&2 -Partilaly Type Tested panel with IP 65 (outdoor type).PTTA Panel shall be tested for all type test as per IEC 60439-1&2 & IEC61641 with aluminum busbar,OEM shall submit the all type test reports during drawing approval. (Dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system,IP65 and minimum 50kA. The Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 60439-1&2 and IEC 61921. Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet,,conforming to IS:8623. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. The Panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel.The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7 tank Powder coated process should present in company pemises) after necessary putty work . The Concerened contactor shall be provide the detailed drawing of panel with complete specification and approved from the Engineer in charge at site.
MCB Single Pole 6-32amp. (10kA, Curve-C)
TP&N Horizontal Double Door Distribution Board 8 way each
MCCB's (FOR PANELS & SHEET ENCLOSURE): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.)
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: CUBICAL PEDESTAL: Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:-
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
Cable End Box for TPN 4 Way
Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm
Main Incomer:- MCCB 100Amp. Microprocesser based, Four Pole, 25 KA = 1 no., Outgoings:- MCCB 40/63/100Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=6 no. (Excluding cost of MCCB's)
Main Incomer:- MCCB 125Amp. Microprocesser based, Four Pole, 25 KA = 1 no., Outgoings:- MCCB 40/63/100Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=6 no. (Excluding cost of MCCB's)
3-STEPPED STEEL TUBULAR POLE (WITH PRE-CAST FOUNDATION): Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP-Mpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix on precast RCC column of suitable dimensions. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The steel tubular pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level including painting of pole with two coats of approved aluminium paint as required:-
Supply and erection of Danger Plate 11000 volts and 440 volts size 200mm x 150mm complete in all respect as desired by engineer in charge of the work.
Overall length 12 metre, length of sections 5.8 metre, 3.1 metre and 3.1metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 193.7mm x 5.4mm, 165.1mm x 4.5mm and 139.7mm x 4.5mm (Bottom, Middle and Top respectively) with approximate weight 259 kg. (410 SP-62), Foundation size below G/L 650mm x 650mm x 2200mm, 4Nos. Foundation Bolts size 24mm dia., Length≥850mm with Base Plate Dimensions 320mm x 320mm x 20mm Thick
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
Supply , fixing , connecting and testing of Factory Manufactured / Company TTA APFC Panel with 7% reactor of capacity 125 KVAR @ 440V along with Capacitors 525V. The stage ratings shall be 1 X 50 KVAR + 1 x 25KVAR + 2 x 12.5KVAR + 1 x 10KVAR+ 3 x 5KVAR The incomer of Each Capacitor Bank should having MCCB 36/25ka as per standards , Ics = 100% Icu & Power Contactors of same rating. The APFC Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 61439-1&2 and IEC 61921. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. As equipment shall be comprising of the following:- 1. Insulated bus bar pan assembly made from copper and rated of 400 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. 2. The incomer of the APFC Panel shall be a 250/320 Amp MCCB / 36KA/4P/TP Microprocessor based LSIG protection. The MCCB shall be of certified design confirming to IEC 60947-1,2 & 3., Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier. 3. Capacitor Units : The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993,13341-1992 & IEC -60831-1&2.
4. Short-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 50kAThe MCCB shall be of certified design confirming to IEC 60947-1,2 & 3. 5. PF Regulator : Advanced Range PF Regulator shall have 6 steps with a LCD Display, Voltage Range : 90V - 550V, 50 / 60Hz, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326. 6. Stage Contactor & Reactor : The electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1. The de-tuning reactors shall be connected in series with each capacitor stage and shall be of iron cored type.The Detuned Reactor Should be equipped with Thermal Switch inside the Winding which should cut-off the respective contactor in case of Over-temperature. Tolerance of reactors shall not exceed +/-3% of rated value.
Supply and erection of LED Flood Light 350watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Aluminium thimble cable Core size 10 -16sq.mm
7. Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted along with the offer. Note:- Manufacturer/Company of Panel should be CPRI Approved & ISO certified (Manufacturer / Company workshop as per ISO9001:2015 standerd). The warranty period will be start after complete commissioning. The Supervision,Inspection & testing at Manufactuers site (By department in contractor scope). The Concerened contactor shall be provide the detailed drawing of panel from OEM designed attested and submitted to department for approval with complete specification in all respects as approved and desired by the Engineer-in-charge at site
MS TOWER LADDER:
Supply and erection of M.S. Tower Ladder suitable for tower structure of height 8.4mtr. made from M.S. Angle iron 30mm x 30mm x 5mm of length 6.94mtr with 24Nos. steps made from M.S. Rods of 16mm dia. for climbing on the tower/ octagonal platform. Each rod should be 300mm long and welded with vertical M.S. angle iron of tower ladder.
Supply and erection of Hot dip galvanised, polygonal high mast with Fixed Head Gear Frame suitable for mounting 20 Nos. of 500W LED Flood Lights as required. The height of the mast from base upto
top of head frame shall be 25.0 Mtrs.( 20 mt high mast + 5 mt fixed head frame) The mast has been designed with Fixed Head Frame shaft shall be structurally suitable to accommodate the requisite flood lights asymmetrical Distribution. with 15 degree Angle and considering base wind speed as per IS 875. High Mast Should Support Manrider Unit Made up of Steel Frame with Special Designed winch with Safety Rope Feature and Power Tool with Auto/Manual Operation with Safe Load Capacity of 300KG with lifting Speed 9m/minute.The Manrider unit must have Security lock & overload protection switch. The Lift must decend if there is no power and magnetic brake would be applied immediately. The Manrider system shall be independent unit with inbuilt Winch & Motor with Remote facility for operations of Manrider. Manrider must have anti fall arresting system with independent safety wire rope of min 8mm.The Soil Bearing Capacity is 10 T/m² at 2.5Mtr Below G.L and Density of Soil 1.44 T/m³, It should be the responsibility of the contractor to get the soil tested from authentic laboratory. All the Specifications and Safety Parameters complete in all respect including supply and installation of of Aviation Dome Light on the top of High Mast Pole as approved and desired by the Engineer-In-Charge at site. (A) Specifications Height of mast:- 25 Mtr Max (20 mt High mast + 5 mt Foxed Head Frame) No of section:- Four Section including fix head frame Length of Bottom Section:- 15 Mtr Minimum Material Construciton:- ASTM A572 Grade 50/ BSEN 10025 5335 Base dia and top diameter:- Base 740mm , Top 350mm (min) Thicnness of base plate :- >- 30mm Cross section of mast:- 20 side polygon Standard of galvansation:- IS2629/ BS-EN ISO 1461 Thickness of base plate:- 30mm minimum Lightining protection final:- G.I single spike of length 1200 mm Minimum Base wind speed as per IS 875:- As per IS:875/ 180Km/Hr Number of foundation bolts:- 8 Nos. PCD of foundation bolts:- 740 mm Miniumum Type/ Diameter/ Length of foundation bolts:- TS 600/30mm dia/minumum 1200 mm long Steel grade:- BSEN-10025with tenslle strength 355N/Sqm/ASTM A572 Thickness of Galvanization:- 85 Microns Minimum Diameter of Baseplate:-Minimum 840mm Size of Door Opening at Base of Mast:- 1200mmX300mm
Casting of suitable open raft type shallow foundation with M-25 cement concrete and steel reinforcement for 25 Mtr. High mast.The Cost of Soil testing in contractor Scope.The rate includes excavation, filling with M-25 cement concrete including disposal of waste material complete with finishing to the satisfaction of Engineer-in charge.Making Reniforced Cement Concrete Foundation for 25 Mtr. High Mast Pole including Earth work in excavation 4400mmX4400mmX2600mm= 52.67 cum, Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) complete 4X4400mmX450mm = 8.09 sqm, Providing/Laying of cement concrete 1:4:8 with brick/stone complete 4400mmX4400mmX100mm =2.0 cum, Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. Complete 4X2350mmX1500mm =14.40 sqm, Providing/ Laying reniforced cement concrete M25 in base 4400mmX4400mmX450mm =9.12 cum, Providing/ Laying reniforced cement concrete M25 in vertical beam 1500mmX1500mmX2350mm =5.53 cum, Providing/Laying of cold twisted deformed bar FE-500 = 7.08 Qtl.(Approx) complete in all respect as per site requirement and as desired by the Engineer in charge and as per drawing supplied by the high mast pole manufacturer.
Supply and erection of LED Flood Light 500watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Supply and erection of LED Recessed downlighter 6watt LED (including constant LED driver) with High quality Presure die cast aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Manrider Unit suitable for 25 meter height pole made up of Steel Frame with Special Designed winch with Safety Rope Feature and Power Tool with Auto/ Manual Operation with Safe Load Capacity of 300KG with lifting Speed 4m/minute.The Manrider unit must have Security lock & overload protection switch. The Lift must decend if there is no power and magnetic brake would be applied immediately. There is no motor or winch shall be placed inside of the Mast. The Manrider system shall be independent unit with inbuilt Winch & Motor with Remote facility for operations of Manrider. Manrider must have anti fall arresting system with independent safety wire rope of min 8mm complete in all respect as approved and desired by the Engineer-In-Charge at site. in charge and as per drawing supplied by the high mast pole manufacturer.
On Load Change Over Switch Four Pole 160amp., 415volts
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
Overall size 1.5sq.mm (48/0.20mm), 3Core
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (on surface) as per PWD General Specifications:-
MCB Double Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 40amp. (10kA, Curve-C)
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
SP&N Double Door Distribution Board 8 way each
Scraping of cement plaster
clearing ang grubbing road land
Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm (+ 0.05 %) thick
25mm i/d Brass Ball valves
SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS): Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:-
Ceiling Rose (Flush Piano type)
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Overall size 10sq.mm (Un-sheathed)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring call-bell point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
Aluminium thimble cable Core size 240sq.mm
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Overall size 10sq.mm (4Core) Un-armoured (Loose)
Overall size 16sq.mm (4Core) Un-armoured (Loose)
Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
On Load Change Over Switch Four Pole 160amp., 415volts
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
Wiring light point with double control switches.
Designing, Supplying, installation, testing & commissioning of Oudoor cubical type Designed Indoor PTTA LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 60439-1&2 -Partilaly Type Tested panel with IP 65 (outdoor type).PTTA Panel shall be tested for all type test as per IEC 60439-1&2 & IEC61641 with aluminum busbar,OEM shall submit the all type test reports during drawing approval. (Dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system,IP65 and minimum 50kA. The Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 60439-1&2 and IEC 61921. Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet,,conforming to IS:8623. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. The Panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel.The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7 tank Powder coated process should present in company pemises) after necessary putty work . The Concerened contactor shall be provide the detailed drawing of panel with complete specification and approved from the Engineer in charge at site.
MCB Single Pole 6-32amp. (10kA, Curve-C)
Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan.
MCB Triple Pole 50, 63amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
Pipe 25mm dia. (On Surface)
Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed)
COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:
Additional Length 20mm x 3mm thick Copper Tape
Bus Bar Chamber 63amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal
GI Earth rod 20 mm dia., 3 mtr. Long
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Double Pole 40amp. (10kA, Curve-C)
Overall size 16sq.mm (Un-sheathed)
Supply and erection of RCBO (Residual Current Breaker Overload) for Earth leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61009 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Triple Pole 40amp. (10kA, Curve-C)
AUTOMATIC VOLTAGE STABLIZER, TIMER: S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO
Street Light Controller (For Single Phase Circuit) with 1 No. Three Pole Power Contactor 40A, 1 No. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 1 No. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
MCB Four Pole 40amp. (10kA, Curve-C)
MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
Cable End Box for TPN 6 Way
ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): LT PANELS: Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floo
r mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Aluminium thimble cable Core size 10 -16sq.mm
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCB's 40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm)(FOR SWIMMING POOL) (Main Panel Incomer:- MCCB 125Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=4 no., MCCB 40Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=2 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE: Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½" x 1½" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thick triangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:-
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
Double Walled Corrugated HDPE Pipe 90/ 76mm (Outer/ Inner dia.)
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Aluminium thimble cable Core size 50sq.mm
Aluminium thimble cable Core size 70sq.mm
The outer surface of the muff shall be finished with 1:2 cement plaster with two coats of white snowcem complete in all respect as approved and desired by the Engineer in-Charge at site:-
LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS: Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-
Casting of suitable open raft type shallow foundation with M-25 cement concrete and steel reinforcement for 25 Mtr. High mast.The Cost of Soil testing in contractor Scope.The rate includes excavation, filling with M-25 cement concrete including disposal of waste material complete with finishing to the satisfaction of Engineer-in charge.Making Reniforced Cement Concrete Foundation for 25 Mtr. High Mast Pole including Earth work in excavation 4400mmX4400mmX2600mm= 52.67 cum, Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) complete 4X4400mmX450mm = 8.09 sqm, Providing/Laying of cement concrete 1:4:8 with brick/stone complete 4400mmX4400mmX100mm =2.0 cum, Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. Complete 4X2350mmX1500mm =14.40 sqm, Providing/ Laying reniforced cement concrete M25 in base 4400mmX4400mmX450mm =9.12 cum, Providing/ Laying reniforced cement concrete M25 in vertical beam 1500mmX1500mmX2350mm =5.53 cum, Providing/Laying of cold twisted deformed bar FE-500 = 7.08 Qtl.(Approx) complete in all respect as per site requirement and as desired by the Engineer in charge and as per drawing supplied by the high mast pole manufacturer.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
Supply, Erection, Testing and Commisioning of HT 11kV Package Substations 400KVA is completely self-contained Solution for power distribution that includes Pre fabricated outdoor duty enclosure, high voltage switchgear, distribution transformer, low voltage panel and accessories such as power factor improvement equipment, control and protection equipments, all providing a cost effective. The complete unit shall be installed on a substation plint (base) as outdoor substation. Package substation shall have the following equipments: 11kV Switchgear: 11 kV, 3 Phase, SF6 compact switchgear panel with 11kV Load break switches controls incoming-outgoing feeder cables of 11kV ring main distribution system and Vacuum circuit breaker (VCB) as protection to the transformer. The Load break switch, Vacuum circuit breaker, Bus bars should be mounted inside a sealed robotically welded stainless steel tank enclosure. The operating mechanism of switches and breakers shall be outside the SF6 tank and accesible from front. The tank should be filled with SF6 gas at an adequate pressure. The degree of protection for gas tank should be IP67. There shall be provision for filling the SF6 gas at site. Stainless steel gas tank shall confirm to the sealed pressure system and ensure the gas leakage to 0.1% per year as per IEC 60298. The Panels shall be tested for IAC level of min. 21kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 40 opeartion. Load break switch parameters are as below: (a). 11kV, 3Phase HT manually operated Load break switches 630Amp., copper busbars with integral earth switch having ON/OFF/EARTHED indiaction, live cable indiaction cable termination bushing suitable for 300sq mm XLPE cable. (b). Type: Load breaking and fault making in SF6 tank (c). Fault making capacity : 52.5kAp (d). Operating Mechanism: Operating handle with ON, OFF, Earth positions with arrangement for padlocking in each position
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring light point
VCB parameters are as below: (a). Rated Voltage/ PF withstand/ Impulse withstand: 11kV/28kV/52.5kVp (b). Rated short circuit breaking current withstand : Min. 21kA for 3sec. (c). Operating mechanism: Trip free & free handle type mechanically operated indication & pad locking (d). Cast Resin CT's 11kV : 100-50/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (e). Digital Ammeter : Applic
Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
On Load Change Over Switch Four Pole 160amp., 415volts
Designing, Supplying, installation, testing & commissioning of Oudoor cubical type Designed Indoor PTTA LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 60439-1&2 -Partilaly Type Tested panel with IP 65 (outdoor type).PTTA Panel shall be tested for all type test as per IEC 60439-1&2 & IEC61641 with aluminum busbar,OEM shall submit the all type test reports during drawing approval. (Dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system,IP65 and minimum 50kA. The Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 60439-1&2 and IEC 61921. Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet,,conforming to IS:8623. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. The Panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel.The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7 tank Powder coated process should present in company pemises) after necessary putty work . The Concerened contactor shall be provide the detailed drawing of panel with complete specification and approved from the Engineer in charge at site.
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Cable End Box for TPN Vertical 4/8/12Way
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
eports. The Supervision,Inspection & testing at Manufactuers site(By department). The Concerened contactor shall be provide the detailed drawing of panel from company designed attested and submitted to department for approval with complete specification and approved from the Engineer in charge at site. Bus Bar :- 1000A, TPN Aluminium Busbar suitable for with standing fault level of 50KA with heat shrinkable coloured sleeves i/c SMC/DMC bus bar supports at required intervals. (Current density shall be maximum 1.3 A/sqmm) The Cost of ACB, MCCB, MCB, C/O Switch etc included & Detail of ACB/MCCB's to be installed in the cubical panel Enclosure as per following .
Supply , fixing , connecting and testing of Factory Manufactured / Company TTA APFC Panel with 7% reactor of capacity 125 KVAR @ 440V along with Capacitors 525V. The stage ratings shall be 1 X 50 KVAR + 1 x 25KVAR + 2 x 12.5KVAR + 1 x 10KVAR+ 3 x 5KVAR The incomer of Each Capacitor Bank should having MCCB 36/25ka as per standards , Ics = 100% Icu & Power Contactors of same rating. The APFC Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 61439-1&2 and IEC 61921. The APFC Panel shall be (Indoor) type, weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. As equipment shall be comprising of the following:- 1. Insulated bus bar pan assembly made from copper and rated of 400 Amps capacity. The short circuit withstand capacity shall be 50 KA / 1 Sec ( Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. 2. The incomer of the APFC Panel shall be a 250/320 Amp MCCB / 36KA/4P/TP Microprocessor based LSIG protection. The MCCB shall be of certified design confirming to IEC 60947-1,2 & 3., Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier. 3. Capacitor Units : The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993,13341-1992 & IEC -60831-1&2.
4. Short-circuit and Overload Protection : Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 50kAThe MCCB shall be of certified design confirming to IEC 60947-1,2 & 3. 5. PF Regulator : Advanced Range PF Regulator shall have 6 steps with a LCD Display, Voltage Range : 90V - 550V, 50 / 60Hz, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326. 6. Stage Contactor & Reactor : The electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1. The de-tuning reactors shall be connected in series with each capacitor stage and shall be of iron cored type.The Detuned Reactor Should be equipped with Thermal Switch inside the Winding which should cut-off the respective contactor in case of Over-temperature. Tolerance of reactors shall not exceed +/-3% of rated value.
7. Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted along with the offer. Note:- Manufacturer/Company of Panel should be CPRI Approved & ISO certified (Manufacturer / Company workshop as per ISO9001:2015 standerd). The warranty period will be start after complete commissioning. The Supervision,Inspection & testing at Manufactuers site (By department in contractor scope). The Concerened contactor shall be provide the detailed drawing of panel from OEM designed attested and submitted to department for approval with complete specification in all respects as approved and desired by the Engineer-in-charge at site
Overall size 10sq.mm (3Core) Un-armoured (On-Surface)
Single Arm Bracket 1 metre Long for Steel Tubular Pole (7 to 8m)
Overall length 7 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2), Foundation size below G/L 550mm x 550mm x 1400mm, 4Nos. Foundation Bolts size 20mm dia., Length≥700mm with Base Plate Dimensions 240mm x 240mm x 16mm Thick (approx. weight 7.235 kg.)
Cubical Size 1400mm high, 1200mm wide and 500mm deep with platform dimensions 1300mm x 600mm x 450mm
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)
Additional Length 25mm x 3mm thick Copper Tape
Supply, installation, testing & Commissioning of 5 meter Steel Poles are made out of galvanised mild steel tubes having (140mm dia at bottom and 75mm dia at top) with cast iron and Emlishment -Q4.The pole are primer coated and painted with polyurethane paint. The pole are suitable for single/double triple/four side post top/drop down luminaries.The pole has service window at the bottom compresing four way 25Amp connector terminal and a MCB rating of 6A . Pole has a mild steel plate having four number mounting hole as per drawing provided by manufacturer and can be mounted with four number anchor bolt. Coating on pole should have minimum DFT of 90 microns. Total height of the lighting pole shall be 4000 mm without foundation bolt as recommended by pole manufatures company. Complete in all respect to the entire satisfaction of the engineer-in-charge.
Making of Cement Concrete plinth 600mm x 600mm x 1800mm deep for fixing of tubular poles, Earth Work in excavation in foundations including dressing of bottom and sides of trenches, shuttering for faces of concrete foundations, cage of cold twisted deformed steel Bar Fe 500 grade as per IS 1786-2008 & filling with reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator complete including fixing the 4 nos foundation bolts in cement concrete plith in all respects as approved and desired by the Engineer-in-charge at site.
Supply and Erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14m
etre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
CPVC SDR 11 Pipe & fitting 32mm o/d
Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 40KVA/32KW without AMF Panel, Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be Water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable 53 BHP for giving a power rating as per ISO 8528- Part-1 (With CPCB-IV Norms upto date amendments) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled
Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.
MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-42 degree of protection & front operated, composite meter for digital display. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site
Making of Cement concrete foundation of size 15' X 8' X 2' high for DG Set. The foundation start with Earth work in excavation 16' x 10' in foundations, Cement Concrete 1:5:10 with 40mm gauge stone agreegate mixing by mechanical means using concrete mixer volumetric type of size 15'x10'x0.75' , First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth size 15'x1.125'x 2' , Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres sizes 15.75'x5.75'x2', Shuttering for faces of concrete foundations and foundations, Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. sizes 15'x8'x0.5', Cold twisted deformed (Ribbed/for Steel Bar) Bar Fe 500 grade as per IS 1786-2008 complete in all respect as per site requirement and as desired by the Engineer in charge.
1. Solar PV Module Warranty 25 Years & Certified Under IS/IEC 61730 1&2 IS/ IEC 61701 & IS/IEC 14286 & IEC 61215, BIS Certificates & MNRE, GOI latest specifications / Standards. 2. Power Conditioning Unit (String Solar Inverter) & Certified under IEC/EN 62109-1,IEC / EN 62102-2 , EN 61000-6-2, EN61000-6-3, IEC61683, EN 50530 , IEC 60068-2-1,2,14,30,EN 60529, IES 60947 Part 1,2,3 IS 60947 Part 1&2 , IES 60227/IS 694,IES 60502/IS 1554 BIS Certificates & MNRE, GOI latest specifications / Standards. 3. Structure : 25 Years Service Life with AMC & Certified under IS 2062:2011 4. Complete Plant Insurance for the period of 5 Years (Excluding Theft of the material) 5. Annual Maintenance Contarct for the period of 5 Years Conditions:- 1. The Plant will be installed as per MNRE and GOI guidelines specifications.(Detail of Material as per Annxeure -1 Attached) 2. The Work will got done from approved MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) Contractors.PWD enlisted contractor subject to condition that PWD Enlisted contractor will get work done from MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) approved Conractors. The Rates are inclusive of Bi-directional meter testing charges, PSPCL Connection Charges, Unidirectional meter cost and all type of taxes including GST
Wiring fan point (Without fan box)
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp)
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): LT PANELS: Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Vo
lts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm)(FOR ATHELTIC SPORTS HALL) (Main Panel Incomer:- MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=6 no., MCCB 100Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=1 no. ,On Load Change Over swtich 160A FP = 1 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester
Supply and erection of Hot dip galvanised, polygonal high mast with Fixed Head Gear Frame suitable for mounting 20 Nos. of 500W LED Flood Lights as required. The height of the mast from base upto top of head frame shall be 25.0 Mtrs.( 20 mt high mast + 5 mt fixed head frame) The mast has been designed with Fixed Head Frame shaft shall be structurally suitable to accommodate the requisite flood lights asymmetrical Distribution. with 15 degree Angle and considering base wind speed as per IS 875. High Mast Should Support Manrider Unit Made up of Steel Frame with Special Designed winch with Safety Rope Feature and Power Tool with Auto/Manual Operation with Safe Load Capacity of 300KG with lifting Speed 9m/minute.The Manrider unit must have Security lock & overload protection switch. The Lift must decend if there is no power and magnetic brake would be applied immediately. The Manrider system shall be independent unit with inbuilt Winch & Motor with Remote facility for operations of Manrider. Manrider must have anti fall arresting system with independent safety wire rope of min 8mm.The Soil Bearing Capacity is 10 T/m² at 2.5Mtr Below G.L and Density of Soil 1.44 T/m³, It should be the responsibility of the contractor to get the soil tested from authentic laboratory. All the Specifications and Safety Parameters complete in all respect including supply and installation of of Aviation Dome Light on the top of High Mast Pole as approved and desired by the Engineer-In-Charge at site.
Clearing herbaceous wild growth From open areas with shrub master and brush cutter, collection and disposal of undesirable material.
(A) Specifications Height of mast:- 25 Mtr Max (20 mt High mast + 5 mt Foxed Head Frame) No of section:- Four Section including fix head frame Length of Bottom Section:- 15 Mtr Minimum Material Construciton:- ASTM A572 Grade 50/ BSEN 10025 5335 Base dia and top diameter:- Base 740mm , Top 350mm (min) Thicnness of base plate :- >- 30mm Cross section of mast:- 20 side polygon Standard of galvansation:- IS2629/ BS-EN ISO 1461 Thickness of base plate:- 30mm minimum Lightining protection final:- G.I single spike of length 1200 mm Minimum Base wind speed as per IS 875:- As per IS:875/ 180Km/Hr Number of foundation bolts:- 8 Nos. PCD of foundation bolts:- 740 mm Miniumum Type/ Diameter/ Length of foundation bolts:- TS 600/30mm dia/minumum 1200 mm long Steel grade:- BSEN-10025with tenslle strength 355N/Sqm/ASTM A572 Thickness of Galvanization:- 85 Microns Minimum Diameter of Baseplate:-Minimum 840mm Size of Door Opening at Base of Mast:- 1200mmX300mm (B) LANTERN CARRIAGE Material of Construciton:- 40/50 NB ERW Class B- M.S.Pipe/ ICMC Channel Hight/ LANTERN CARRIAGE:- 3000mm Min No of Luminaries:- 20 Nos. Type:- Asymmetrical
(C) CONTROL CABLE Cable for supply:- Copper Conductor, 6.0 sq mm 5 core maximum Insulation/sheathed:- EPR Insulated & PCP sheathed/ PVC No of cables/ circuits per mast:-
1 No (3phase) flexible tpe multicore (D) WINCH/POWER TOOL Type/SWL of which:- Double drum (DD2GPB) tested from IIT/ any accredited Lab of Govt. of India approved with specific Load bearing capacity 750kg Method of operation:- Integral Motor Motor Capacity:- 2HP Power tool 3 phase electric moter reversible type 415/250 volt intergral (inside high mast) No of speeds:- Single speed 6 pole (E) STAINLESS STEEL WIRE ROPE Grade/ construction:- ASIS 316,7/19,SS 316,7/19 construction tested from IIT and of reputed make e.g Usha Martin or Equivalent. Number of Ropes:- 3 Nos Diametre of Rope (mm):- 8 mm dia Breaking load capacity of rope:- Minumum 3250 Kg per SS wire rope Foundation Bolts:- The foundation bolts included as same as supplied by the high Mast manufacturing company as per high mast standard with suitable size and length. Complete in all respect including connections, testing & other petty material required for commissioning as desired by the Engineer In Charge.
Supply and erection of LED type single dome aviation obstruction light with LED lamps on the existing 20 meter High Mast pole complete in all respect as approved and desired by the Engineer-In-Charge at site.
Public Health
Sub work-1
Sub head-1 Water Supply System
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
CPVC SDR 11 Pipe & fitting 20 mm o/d
SDR 11 CPVC pipes & fittings 25mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.
Size 75 mm x 75 mm
Providing, fixing and jointing CPVC Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. Union 25 mm o/d complete
For 2000 ltr Water Tank
Providing, fixing and jointing CPVC Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
20mm i/d Brass Ball valves
40mm i/d Brass Ball valves
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks
2000 Ltr x4 nos.
Construction of Plateform complete as per specification & as desired by Enginer-in-charge For 2000 ltr Water Tank
Providing & fixing in position CPVC.tank nipple of approved make to the approval of engineer in charge in PVC water storage tanks complete in all respects. .CPVC tank nipple 40 mm i/d
Providing and fixing in position automatic brass ball valves in tanks. 40 mm i/d Brass ball valve with plastic ball with G.I. socket
Sub head-2 Sewerage System
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
110mm o/d single socket SWR UPVC pipe lines laid complete
Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes
For 110mm o/d pipes
Elbow 90 Degree (All side socketed) bend 110 mm
Door Elbow 90 Degree (All side socketed) door bend 110mm
P Trap/Floor Trap 110mm x 110mm
For 90mm o/d pipes
Elbow 90 degree (all side socket) door bend 90mm
Single Tee
Door elbow 90 degree (all side socket)
32mm i/d Brass Ball valves
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty double sea
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
Sub head-3 wall / Floor tile work & False Ceilling
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/ Glosy/ Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling using mechanical mixer for mixing of material
Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
BlackGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coarsesand)andjointedwithneatcementslurry mixedwithpigment tomatchtheshadeofstone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Sub head-4 Sanitary Fixtures & CP Brass Fittings
Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge.
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Providing and fixing in position concealed cistern including flushing plate of approved make (to the approval of the Engineer-incharge) complete in all respect.
Providing and fixing Stainless steel health faucet complete in all respect.
Providing and fixing jet spray with 2'-6" long PVC pipe.With C.P. Brass nut
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all espect. Note:-To be provided only for VIP Installations and with prior approval of the Engineer-in-charge. C.P. brass Bib cock with Wall flange
Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge) C.P. Brass Pillar Cock foam flow
Providing &Fixing in position C.P. Brass Hexa Nipple 15mmofapprovedmake(tothe approvalofEngineer-in-charge)completein all respect.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 630mm x 500mm (above counter oval)
Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge)
Providing and fixing in position premium range paper holders of approved make (to the approval of Engineer-in
-charge ) fixed in to wall with C.P brass screws complete in all respect. C.P. brass toilet roll holder with flap
Providing and fixing in position premium range towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P brass towel ring square
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. brass liquid soap container
Providing & Fixing in position premium range Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P.brass 15mm Angle valve without flange
Providing & Fixing in position 5mm thick bevelled edgemirror of superior glass (of approvedmake) completewith 4mm thick hardboardbacking fixed inwithrawl plugs 50 mm, C.P.brass screws and washer sand S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 450mmx600mm or any other size
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 4 pegs
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
Providing and fixing in position vitreous Chinaware white lIndian make large flatback orangular lipped front urinal 375x390x590 mm of approved make (to the approval of the Engineer-in-charge) consistingofC.P.brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Vitreous white Chinaware Partition Large partition size 75x16.5x 36.5 cm
Providing & fixing in position best Indian make flexible tube connection of approved make to the approval of engineer in charge complete in all respects. PVC tube connection of size 15 mm x450 mm with C.P. Brass nut
Providing & Fixing in position C.P. Brass flange under various fixtures complete in all respects (as required by the Engineer-in-Charge)
Sub head-5 Fire fighting System
Providing and fixing of FIRE EXTINGUISHER, ABCPowder type (stored pressure) asper IS:15683 completewithall accessories as per Manufactures Specification. ISI Mark complete in all respect.6 Kg. Capacity
Providing and fixing of FIRE EXTINGUISHER,CO2typeasper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.4.5 Kg. Capacity
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks, 5000 Ltr x4 nos.
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.
Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required.
Supply and Erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.
etre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
CPVC SDR 11 Pipe & fitting 32mm o/d
Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 40KVA/32KW without AMF Panel, Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be Water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable 53 BHP for giving a power rating as per ISO 8528- Part-1 (With CPCB-IV Norms upto date amendments) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled
Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.
Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect.
Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. 80 mm i/d check valve
Providing and fixing S.S Pressure Gauge complete as required complete in all respect. Dial diameter 100mm calibration 0-16 kg
Providing and fixing Vane type Water flow switch in MS Pipe line for a service pressure up to 450PSI , Minimum flow rate for alarm 10GPM (38 LPM ), Minimum surge 18 FPS (5.5 m/s ) including connection with panel complete in all respect
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. ZONE-6
External work FIRE SYSTEM
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects.
Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc. 1200 mm wide x 900 mm high x 400 mm deep Size
Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm)(FOR ATHELTIC SPORTS HALL) (Main Panel Incomer:- MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=6 no., MCCB 100Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=1 no. ,On Load Change Over swtich 160A FP = 1 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
Construction of Plateform complete as per specification & as desired by Enginer-in-charge. For 5000 ltr Water Tank
Supply and erection of Hot dip galvanised, polygonal high mast with Fixed Head Gear Frame suitable for mounting 20 Nos. of 500W LED Flood Lights as required. The height of the mast from base upto top of head frame shall be 25.0 Mtrs.( 20 mt high mast + 5 mt fixed head frame) The mast has been designed with Fixed Head Frame shaft shall be structurally suitable to accommodate the requisite flood lights asymmetrical Distribution. with 15 degree Angle and considering base wind speed as per IS 875. High Mast Should Support Manrider Unit Made up of Steel Frame with Special Designed winch with Safety Rope Feature and Power Tool with Auto/Manual Operation with Safe Load Capacity of 300KG with lifting Speed 9m/minute.The Manrider unit must have Security lock & overload protection switch. The Lift must decend if there is no power and magnetic brake would be applied immediately. The Manrider system shall be independent unit with inbuilt Winch & Motor with Remote facility for operations of Manrider. Manrider must have anti fall arresting system with independent safety wire rope of min 8mm.The Soil Bearing Capacity is 10 T/m² at 2.5Mtr Below G.L and Density of Soil 1.44 T/m³, It should be the responsibility of the contractor to get the soil tested from authentic laboratory. All the Specifications and Safety Parameters complete in all respect including supply and installation of of Aviation Dome Light on the top of High Mast Pole as approved and desired by the Engineer-In-Charge at site.
Clearing herbaceous wild growth From open areas with shrub master and brush cutter, collection and disposal of undesirable material.
(A) Specifications Height of mast:- 25 Mtr Max (20 mt High mast + 5 mt Foxed Head Frame) No of section:- Four Section including fix head frame Length of Bottom Section:- 15 Mtr Minimum Material Construciton:- ASTM A572 Grade 50/ BSEN 10025 5335 Base dia and top diameter:- Base 740mm , Top 350mm (min) Thicnness of base plate :- >- 30mm Cross section of mast:- 20 side polygon Standard of galvansation:- IS2629/ BS-EN ISO 1461 Thickness of base plate:- 30mm minimum Lightining protection final:- G.I single spike of length 1200 mm Minimum Base wind speed as per IS 875:- As per IS:875/ 180Km/Hr Number of foundation bolts:- 8 Nos. PCD of foundation bolts:- 740 mm Miniumum Type/ Diameter/ Length of foundation bolts:- TS 600/30mm dia/minumum 1200 mm long Steel grade:- BSEN-10025with tenslle strength 355N/Sqm/ASTM A572 Thickness of Galvanization:- 85 Microns Minimum Diameter of Baseplate:-Minimum 840mm Size of Door Opening at Base of Mast:- 1200mmX300mm (B) LANTERN CARRIAGE Material of Construciton:- 40/50 NB ERW Class B- M.S.Pipe/ ICMC Channel Hight/ LANTERN CARRIAGE:- 3000mm Min No of Luminaries:- 20 Nos. Type:- Asymmetrical
(C) CONTROL CABLE Cable for supply:- Copper Conductor, 6.0 sq mm 5 core maximum Insulation/sheathed:- EPR Insulated & PCP sheathed/ PVC No of cables/ circuits per mast:-
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 Pipe & fitting 32mm o/d
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete. 32mm i/d Brass Ball valves
Public Health
Sub work-1
CPVC SDR 11 Pipe & fitting 20 mm o/d
oviding and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball Brass Ball Cock with rod and Plastic Ball 32mm i/d
Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank). Two Way inlet connection
Size 75 mm x 75 mm
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325 M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads 450 LPM AT 35 M HEAD
For 2000 ltr Water Tank
Providing, fixing and jointing CPVC Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
Sub head-6 Water cooler , RO And Air conditioning
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks
2000 Ltr x4 nos.
Construction of Plateform complete as per specification & as desired by Enginer-in-charge For 2000 ltr Water Tank
Providing & fixing in position RO of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Providing and fixing in position automatic brass ball valves in tanks. 40 mm i/d Brass ball valve with plastic ball with G.I. socket
Providing & fixing in position Split AC 2 ton 5 Star invter type with all fitting and Steplizer out let Stand Electric Cable with drain pipe etc of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Construction of Multipurpose Sports Hall G+1 at Sports Stadium kaheru,Dhuri Distt Sangrur.
CPVC SDR 11 Pipe & fitting 20mm o/d
Providing, fixing and jointing CPVC Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. Union 25 mm o/d complete
Union 40 mm o/d complete
Providing, fixing and jointing PVC Ball valves screwed with PVC ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes
25mm i/d PVC Ball valves
40mm i/d PVC Ball valves
Elbow 90 Degree (All side socketed) bend 110 mm
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
Triple Layer Tanks. 5000 Ltr x2 nos.
C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)
Construction of Plateform complete as per specification & as desired by Enginer-in-charge
For 5000 ltr Water Tank
For 90mm o/d pipes
Providing and fixing in position CPVC Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
CPVC. tank nipple 40mm i/d
Providing and fixing in position automatic brass ball valves in tanks.
Door elbow 90 degree (all side socket)
32mm i/d Brass Ball valves
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty double sea
40 mm i/d Brass ball valve with plastic ball with G.I. socket
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Sub head-3 wall / Floor tile work & False Ceilling
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/ Glosy/ Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling using mechanical mixer for mixing of material
Elbow 90 Degree (All side socketed)
Door Elbow 90 Degree (All side socketed)
BlackGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coarsesand)andjointedwithneatcementslurry mixedwithpigment tomatchtheshadeofstone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Sub head-4 Sanitary Fixtures & CP Brass Fittings
Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge.
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. ZONE-6
Elbow 90 degree (all side socket)
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty double sea
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
Providing and fixing jet spray with 2'-6" long PVC pipe.With C.P. Brass nut
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all espect. Note:-To be provided only for VIP Installations and with prior approval of the Engineer-in-charge. C.P. brass Bib cock with Wall flange
Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge) C.P. Brass Pillar Cock foam flow
Providing &Fixing in position C.P. Brass Hexa Nipple 15mmofapprovedmake(tothe approvalofEngineer-in-charge)completein all respect.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
BlackGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coarsesand)andjointedwithneatcementslurry mixedwithpigment tomatchtheshadeofstone, including rubbingandpolishing including labour for fixing dowel pins and cramps.
Providing and fixing in position concealed cistern including flushing plate of approved make (to the approval of the Engineer-incharge) complete in all respect.
Providing and fixing in position premium range paper holders of approved make (to the approval of Engineer-in
-charge ) fixed in to wall with C.P brass screws complete in all respect. C.P. brass toilet roll holder with flap
Providing and fixing in position premium range towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P brass towel ring square
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing and fixing jet spray with 2'-6" long PVC pipe.With C.P. Brass nut
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
Providing & Fixing in position premium range Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.Note:-To be provided only for VIP Installations and with prior approval of the Engineer-in-charge.
Providing & Fixing in position 5mm thick bevelled edgemirror of superior glass (of approvedmake) completewith 4mm thick hardboardbacking fixed inwithrawl plugs 50 mm, C.P.brass screws and washer sand S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 450mmx600mm or any other size
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 4 pegs
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
C.P. brass Bib cock with Wall flange
C.P. brass Bib cock long nose/ long body foam flow without flange
Single Tee With Door
Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge)
CPVC SDR 11 Pipe & fitting 40mm o/d
C.P. Brass Pillar Cock foam flow
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect.
Size 630mm x 500mm (above counter oval)
Providing and fixing in position C.P. brass overhead shower arm chrome round or square with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect.CP Brass rain Fall Shower arm 24" length round chrome
Providing and fixing in position premium range paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.
Providing and fixing in position premium range towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P brass towel ring square
Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P. brass liquid soap container
Providing & Fixing in postion premium range Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Providing and fixing of FIRE EXTINGUISHER,CO2typeasper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.4.5 Kg. Capacity
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.
C.P. Brass khunti with 4 pegs
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.
Providing & fixing in position best Indian make flexible tube connection of approved make to the approval of engineer in charge complete in all respects.
Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.
etre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
CPVC SDR 11 Pipe & fitting 32mm o/d
Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 40KVA/32KW without AMF Panel, Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be Water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable 53 BHP for giving a power rating as per ISO 8528- Part-1 (With CPCB-IV Norms upto date amendments) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled
Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.
Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect.
Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. 80 mm i/d check valve
PVC tube connection of size 15 mm x450 mm with C.P. Brass nut
Providing and fixing Vane type Water flow switch in MS Pipe line for a service pressure up to 450PSI , Minimum flow rate for alarm 10GPM (38 LPM ), Minimum surge 18 FPS (5.5 m/s ) including connection with panel complete in all respect
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. ZONE-6
Triple Layer Tanks. 10000 Ltr x2 nos.
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
C.P. brass toilet roll holder with flap
Providing, la
ying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm)(FOR ATHELTIC SPORTS HALL) (Main Panel Incomer:- MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=6 no., MCCB 100Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=1 no. ,On Load Change Over swtich 160A FP = 1 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester
Supply and erection of Hot dip galvanised, polygonal high mast with Fixed Head Gear Frame suitable for mounting 20 Nos. of 500W LED Flood Lights as required. The height of the mast from base upto top of head frame shall be 25.0 Mtrs.( 20 mt high mast + 5 mt fixed head frame) The mast has been designed with Fixed Head Frame shaft shall be structurally suitable to accommodate the requisite flood lights asymmetrical Distribution. with 15 degree Angle and considering base wind speed as per IS 875. High Mast Should Support Manrider Unit Made up of Steel Frame with Special Designed winch with Safety Rope Feature and Power Tool with Auto/Manual Operation with Safe Load Capacity of 300KG with lifting Speed 9m/minute.The Manrider unit must have Security lock & overload protection switch. The Lift must decend if there is no power and magnetic brake would be applied immediately. The Manrider system shall be independent unit with inbuilt Winch & Motor with Remote facility for operations of Manrider. Manrider must have anti fall arresting system with independent safety wire rope of min 8mm.The Soil Bearing Capacity is 10 T/m² at 2.5Mtr Below G.L and Density of Soil 1.44 T/m³, It should be the responsibility of the contractor to get the soil tested from authentic laboratory. All the Specifications and Safety Parameters complete in all respect including supply and installation of of Aviation Dome Light on the top of High Mast Pole as approved and desired by the Engineer-In-Charge at site.
Clearing herbaceous wild growth From open areas with shrub master and brush cutter, collection and disposal of undesirable material.
(A) Specifications Height of mast:- 25 Mtr Max (20 mt High mast + 5 mt Foxed Head Frame) No of section:- Four Section including fix head frame Length of Bottom Section:- 15 Mtr Minimum Material Construciton:- ASTM A572 Grade 50/ BSEN 10025 5335 Base dia and top diameter:- Base 740mm , Top 350mm (min) Thicnness of base plate :- >- 30mm Cross section of mast:- 20 side polygon Standard of galvansation:- IS2629/ BS-EN ISO 1461 Thickness of base plate:- 30mm minimum Lightining protection final:- G.I single spike of length 1200 mm Minimum Base wind speed as per IS 875:- As per IS:875/ 180Km/Hr Number of foundation bolts:- 8 Nos. PCD of foundation bolts:- 740 mm Miniumum Type/ Diameter/ Length of foundation bolts:- TS 600/30mm dia/minumum 1200 mm long Steel grade:- BSEN-10025with tenslle strength 355N/Sqm/ASTM A572 Thickness of Galvanization:- 85 Microns Minimum Diameter of Baseplate:-Minimum 840mm Size of Door Opening at Base of Mast:- 1200mmX300mm (B) LANTERN CARRIAGE Material of Construciton:- 40/50 NB ERW Class B- M.S.Pipe/ ICMC Channel Hight/ LANTERN CARRIAGE:- 3000mm Min No of Luminaries:- 20 Nos. Type:- Asymmetrical
(C) CONTROL CABLE Cable for supply:- Copper Conductor, 6.0 sq mm 5 core maximum Insulation/sheathed:- EPR Insulated & PCP sheathed/ PVC No of cables/ circuits per mast:-
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 Pipe & fitting 32mm o/d
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete. 32mm i/d Brass Ball valves
Public Health
Sub work-1
90mm o/d single socket SWR UPVC pipe lines laid complete
CPVC SDR 11 Pipe & fitting 20 mm o/d
100 mm internal diameter
Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete
Size 75 mm x 75 mm
80 mm i/d check valve
For 2000 ltr Water Tank
Providing, fixing and jointing CPVC Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
Sub head-6 Water cooler , RO And Air conditioning
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks
Construction of Plateform complete as per specification & as desired by Enginer-in-charge For 2000 ltr Water Tank
Providing & fixing in position CPVC.tank nipple of approved make to the approval of engineer in charge in PVC water storage tanks complete in all respects. .CPVC tank nipple 40 mm i/d
Providing and fixing in position automatic brass ball valves in tanks. 40 mm i/d Brass ball valve with plastic ball with G.I. socket
Sub head-2 Sewerage System
Providing and fixing S.S Pressure Gauge complete as required complete in all respect.
CPVC SDR 11 Pipe & fitting 20mm o/d
Providing, fixing and jointing CPVC Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. Union 25 mm o/d complete
Union 40 mm o/d complete
Providing, fixing and jointing PVC Ball valves screwed with PVC ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes
25mm i/d PVC Ball valves
40mm i/d PVC Ball valves
Dial diameter 100mm calibration 0-16 kg
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects.
1200 mm wide x 900 mm high x 400 mm deep Size
C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)
For 10000 ltr Water Tank
For 5000 ltr Water Tank
For 90mm o/d pipes
Providing and fixing in position CPVC Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
CPVC. tank nipple 40mm i/d
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
Door elbow 90 degree (all side socket)
32mm i/d Brass Ball valves
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty double sea
40 mm i/d Brass ball valve with plastic ball with G.I. socket
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Sub head-3 wall / Floor tile work & False Ceilling
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling using mechanical mixer for mixing of material
Elbow 90 Degree (All side socketed)
Door Elbow 90 Degree (All side socketed)
BlackGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coarsesand)andjointedwithneatcementslurry mixedwithpigment tomatchtheshadeofstone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball
Sub head-4 Sanitary Fixtures & CP Brass Fittings
Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge.
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. ZONE-6
Elbow 90 degree (all side socket)
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty double sea
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
Providing and fixing jet spray with 2'-6" long PVC pipe.With C.P. Brass nut
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all espect. Note:-To be provided only for VIP Installations and with prior approval of the Engineer-in-charge. C.P. brass Bib cock with Wall flange
Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge) C.P. Brass Pillar Cock foam flow
Providing &Fixing in position C.P. Brass Hexa Nipple 15mmofapprovedmake(tothe approvalofEngineer-in-charge)completein all respect.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
BlackGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coarsesand)andjointedwithneatcementslurry mixedwithpigment tomatchtheshadeofstone, including rubbingandpolishing including labour for fixing dowel pins and cramps.
Brass Ball Cock with rod and Plastic Ball 32mm i/d
Providing and fixing in position premium range paper holders of approved make (to the approval of Engineer-in
-charge ) fixed in to wall with C.P brass screws complete in all respect. C.P. brass toilet roll holder with flap
Providing and fixing in position premium range towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P brass towel ring square
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing and fixing jet spray with 2'-6" long PVC pipe.With C.P. Brass nut
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
Providing & Fixing in position premium range Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.Note:-To be provided only for VIP Installations and with prior approval of the Engineer-in-charge.
Providing & Fixing in position 5mm thick bevelled edgemirror of superior glass (of approvedmake) completewith 4mm thick hardboardbacking fixed inwithrawl plugs 50 mm, C.P.brass screws and washer sand S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 450mmx600mm or any other size
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 4 pegs
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
C.P. brass Bib cock with Wall flange
C.P. brass Bib cock long nose/ long body foam flow without flange
Single Tee With Door
Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank).
CPVC SDR 11 Pipe & fitting 40mm o/d
Two Way inlet connection
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
Size 630mm x 500mm (above counter oval)
Providing and fixing in position C.P. brass overhead shower arm chrome round or square with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect.CP Brass rain Fall Shower arm 24" length round chrome
Providing and fixing in position premium range paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.
Providing and fixing in position premium range towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P brass towel ring square
Providing & Fixing in postion liquid soap container of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P. brass liquid soap container
Providing & Fixing in postion premium range Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Providing and fixing of FIRE EXTINGUISHER,CO2typeasper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.4.5 Kg. Capacity
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.
C.P. Brass khunti with 4 pegs
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads
450 LPM AT 35 M HEAD
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
Construction of Swimming Pool(25mx15m) at Sports Stadium kaheru,Dhuri Distt Sangrur:- Sub work-1
Providing, fixing and jointing CPVC Ball valves screwed with PVC ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
Triple Layer Tanks. 5000 Ltr x2 nos.
Providing and fixing in position CPVC Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
CPVC tank nipple 40mm i/d
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty double sea
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
Providing and fixing 1st quality ceramic glazed, wall tiles Matt/Semi att/Glosy/ Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. Note:-To be provided only for VIP Installations and with prior approval of the Engineer-in-charge.
Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge)
Providing and fixing in position C.P. brass overhead shower arm chrome round or square with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect.CP Brass rain Fall Shower arm 24" length round chrome
Providing and fixing in position premium range paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.
Providing and fixing in position premium range towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
Providing & Fixing in postion premium range Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Providing and fixing in position vitreous Chinaware white lIndian make large flatback orangular lipped front urinal 375x390x590 mm of approved make (to the approval of the Engineer-in-charge) consistingofC.P.brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Dial diameter 100mm calibration 0-16kg
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.
Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball
Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.
etre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
CPVC SDR 11 Pipe & fitting 32mm o/d
Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 40KVA/32KW without AMF Panel, Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be Water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable 53 BHP for giving a power rating as per ISO 8528- Part-1 (With CPCB-IV Norms upto date amendments) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled
Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.
Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect.
Providing and fixing S.S Pressure Gauge complete as required complete in all respect. Dial diameter 100mm calibration 0-16 kg
Providing and fixing Vane type Water flow switch in MS Pipe line for a service pressure up to 450PSI , Minimum flow rate for alarm 10GPM (38 LPM ), Minimum surge 18 FPS (5.5 m/s ) including connection with panel complete in all respect
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. ZONE-6
Brass Ball Cock with rod and Plastic Ball 32mm i/d
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
C.P. brass toilet roll holder with flap
Providing & fixing in position Split AC 1.5 ton 5 Star invter type with all fitting and Steplizer out let Stand Electric Cable with drain pipe etc of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Sub work-2
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm)(FOR ATHELTIC SPORTS HALL) (Main Panel Incomer:- MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=6 no., MCCB 100Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=1 no. ,On Load Change Over swtich 160A FP = 1 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
Sub head-1 Providing & fixing in position all weather swimming pool meachinery of filtaration system and cold & hot water system approved make complete in all respects.
Supply and erection of Hot dip galvanised, polygonal high mast with Fixed Head Gear Frame suitable for mounting 20 Nos. of 500W LED Flood Lights as required. The height of the mast from base upto top of head frame shall be 25.0 Mtrs.( 20 mt high mast + 5 mt fixed head frame) The mast has been designed with Fixed Head Frame shaft shall be structurally suitable to accommodate the requisite flood lights asymmetrical Distribution. with 15 degree Angle and considering base wind speed as per IS 875. High Mast Should Support Manrider Unit Made up of Steel Frame with Special Designed winch with Safety Rope Feature and Power Tool with Auto/Manual Operation with Safe Load Capacity of 300KG with lifting Speed 9m/minute.The Manrider unit must have Security lock & overload protection switch. The Lift must decend if there is no power and magnetic brake would be applied immediately. The Manrider system shall be independent unit with inbuilt Winch & Motor with Remote facility for operations of Manrider. Manrider must have anti fall arresting system with independent safety wire rope of min 8mm.The Soil Bearing Capacity is 10 T/m² at 2.5Mtr Below G.L and Density of Soil 1.44 T/m³, It should be the responsibility of the contractor to get the soil tested from authentic laboratory. All the Specifications and Safety Parameters complete in all respect including supply and installation of of Aviation Dome Light on the top of High Mast Pole as approved and desired by the Engineer-In-Charge at site.
Clearing herbaceous wild growth From open areas with shrub master and brush cutter, collection and disposal of undesirable material.
(A) Specifications Height of mast:- 25 Mtr Max (20 mt High mast + 5 mt Foxed Head Frame) No of section:- Four Section including fix head frame Length of Bottom Section:- 15 Mtr Minimum Material Construciton:- ASTM A572 Grade 50/ BSEN 10025 5335 Base dia and top diameter:- Base 740mm , Top 350mm (min) Thicnness of base plate :- >- 30mm Cross section of mast:- 20 side polygon Standard of galvansation:- IS2629/ BS-EN ISO 1461 Thickness of base plate:- 30mm minimum Lightining protection final:- G.I single spike of length 1200 mm Minimum Base wind speed as per IS 875:- As per IS:875/ 180Km/Hr Number of foundation bolts:- 8 Nos. PCD of foundation bolts:- 740 mm Miniumum Type/ Diameter/ Length of foundation bolts:- TS 600/30mm dia/minumum 1200 mm long Steel grade:- BSEN-10025with tenslle strength 355N/Sqm/ASTM A572 Thickness of Galvanization:- 85 Microns Minimum Diameter of Baseplate:-Minimum 840mm Size of Door Opening at Base of Mast:- 1200mmX300mm (B) LANTERN CARRIAGE Material of Construciton:- 40/50 NB ERW Class B- M.S.Pipe/ ICMC Channel Hight/ LANTERN CARRIAGE:- 3000mm Min No of Luminaries:- 20 Nos. Type:- Asymmetrical
(C) CONTROL CABLE Cable for supply:- Copper Conductor, 6.0 sq mm 5 core maximum Insulation/sheathed:- EPR Insulated & PCP sheathed/ PVC No of cables/ circuits per mast:-
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. CPVC SDR 11 Pipe & fitting 32mm o/d
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete. 32mm i/d Brass Ball valves
Public Health
Sub work-1
90mm o/d single socket SWR UPVC pipe lines laid complete
CPVC SDR 11 Pipe & fitting 20 mm o/d
100 mm internal diameter
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.
Size 75 mm x 75 mm
LE-1600 DIA MS FILTER (MILD STEEL) 1. SIZE - 1600 DIA Top Mount FRP FILTER With 6 Way Multiport Valve 6 way of Multiport Valve 1. Filter , 2. Backw
For 2000 ltr Water Tank
Providing, fixing and jointing CPVC Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
ash 3. Rinse , 4. Waste 5. Recirculation , 6. Closed Pipe Size ( 63mm PVC ) Working Pressure id 2.5 Kg cm2/36 psi. HEIGHT – 6.5 FEET LENGTH- 2 FEET Operating Temperature 43 Degrees WARRANTY - ONE YEAR
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks
5 HP MOTOR Motor Ip 55 Rating with pre filters. Total Electrical Separation Ambient temperature up to 50 Degree C. Capacitor Inside. Pipe Size ( 63mm PVC ) Make by kiloshkar WARRANTY – ONE YEAR
Providing & fixing in position RO of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Providing and fixing in position automatic brass ball valves in tanks. 40 mm i/d Brass ball valve with plastic ball with G.I. socket
Providing & fixing in position Split AC 2 ton 5 Star invter type with all fitting and Steplizer out let Stand Electric Cable with drain pipe etc of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Construction of Multipurpose Sports Hall G+1 at Sports Stadium kaheru,Dhuri Distt Sangrur.
CPVC SDR 11 Pipe & fitting 20mm o/d
Union 40 mm o/d complete
Providing, fixing and jointing PVC Ball valves screwed with PVC ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes
25mm i/d PVC Ball valves
FILTER MEDIA (PER BAG 50 KG) FILTER MEDIA PACKAGING - 50 KG BAG MASH - 8-16 MASH- 16-32
TEST KIT Water Test Kit Basic Ph` & CI Test Kit Phinol Red - 15 mI Orthotodiline - 15 mI Make by blue Aid
WALL BRUSH Standard wall Brush (Poly bristle Wall Brush ) Size – 18” Weight - 320gm Make by Blue Aid
C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)
For 10000 ltr Water Tank
For 5000 ltr Water Tank
For 90mm o/d pipes
Providing and fixing in position CPVC Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
CPVC. tank nipple 40mm i/d
ALGAE BRUSH Algae Stainless Steel Brush ( Hi- Grade Stainless Steel ) Size – 10” Weight – 190gm Make by Blue Aid
Door elbow 90 degree (all side socket)
32mm i/d Brass Ball valves
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty double sea
40 mm i/d Brass ball valve with plastic ball with G.I. socket
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Sub head-3 wall / Floor tile work & False Ceilling
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling using mechanical mixer for mixing of material
Elbow 90 Degree (All side socketed)
Door Elbow 90 Degree (All side socketed)
BlackGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coarsesand)andjointedwithneatcementslurry mixedwithpigment tomatchtheshadeofstone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball
LEAF NET BLUE/WHITE NET Leaf Net Heavy Duty Plastic Leaf Net Make by blue Aid
TELESCOPIC ROD ALUMINIUM 8 FT. Telescopic Adjustable Rod Size – 8FT. Long. Body – Aluminum Thickness/Blue/Silver Make By BLUE AID
VACUUM HEAD 18 INCHI Vacuum head with 4 wheel , Alu Body Size - 18 inch Weight – 2.20 Kgs Make by blue Aid
Hose Pipe 15 Mtr (Per Pcs) Hose Pipe Extruded EVA Vaccum Hose Quality - EVA Make by Blue Aid
12v-20w 7 INCH Swimming Pool Under Water Light (12 V- 20W)LED Size - 7" Color – As per Requirement IP 68 Rating Make By BLUE AID WARRANTY – ONE YEAR
40 AMP SMPS
EYES BALL NOZZLES (6 KG) Floor Inlet Nozzle Body – ABS Fiber Color – White Flow Rate – 45M3/hr Multiple flow UV Protected Appreciated for long life. Connection 50mm/63mm Suitable for 10Kg & 6 Kg Pressure. Make By BLUE AID
Drilling of 500mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL.
SUCTION VACCUM 6 KG Suction Nozzle Material –ABS Make - Blue Aid
SQURE DRAIN SMALLE Square Main Drain Color – White Flow Rate – 850L/Min Material – ABS Make by BLUE AID
10 Inch Single Pin White (Per Mtr) Swimming Pool Over Flow Grating UV Protected Make by Blue Aid Material –PP,CP Heavy Duty/Non Skid
Construction of Plateform complete as per specification & as desired by Enginer-in-charge. For 5000 ltr Water Tank
Ladder 3 Step Stainless Steel LadderPool Ladder is made with high quality Grade SS 304 Stainless Steel 38/42mm Tube for reliability Durability complete with anchoring fixtures. Make By BLUE AID
TCCA Trichloroisocyanuric Acid (PER KG)GRANULAR CHLORINE PACKAGING - 50 KG DRUM MAHS - 5 TO 8
Four Inchi Racing Lane (Per Mtr.) Swimming Pool Lane Rope Size – 4” with Hook Lane Size – 25 Mtr. Color –Blue/ Red/Yellow/White Rope Material – Stainless SteeRacing Lane Anti Wave
Anchor Hook Anchor Hook Material - ss ( 304 ) Racing Lane Hook
STARTING BLOCK Pool Starting block Material- Stainless Steel and Fiberglass Color – Blue Height - 400 mm Width – 2510 mm
HEAT PUMP 135 KW Heat pump with Patented Titanium heat exchanger , Exterior protected METAL body with reversible defrosting and R410A Gas. Top mounted Three fans Heat Pump Commercial, 135KW Output, 24.1 kw Input power at measuring conditions A 15º C W 27º C
Construction of 1 no Toilet block near Sports Hall at Sports Stadium kaheru,Dhuri Distt Sangrur. Sub work-1
Triple Layer Tanks. 2000 Ltr x4 nos.
Providing & fixing in position CPVC.tank nipple of approved make to the approval of engineer in charge in PVC water storage tanks complete in all respects.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
CPVC. tank nipple 40 mm i/d
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Table Top (size 49 x 40 x 15 cm)
Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge)
Providing and fixing in position premium range paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.
Providing & Fixing in postion premium range Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Construction of External services like Sewer,Strom,Water Supply,UGSR & Tube well at Sports Stadium kaheru,Dhuri Distt Sangrur. Sub work-2
Sub head-1 Estate Water Supply system
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,wateing , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Including Excavation Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
90mm o/d pipe of 10 Kgf. / sqcm
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).
80 mm i/d Sluice Valves flanged
450 LPM AT 35 M HEAD
Size 0.9 m. x 0.9 m.
Sub head-2 Estate Sewerage System & UGSR 25,000 ltr for SPT treted water.
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing
sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , ncluding the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the ouses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Single socket type B
160mm o/d single socket SWR UPVC pipe lines laid complete IC TO MH
Sand filling under floor and in wells of bridge foundation including handling withing 100 metres
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.
Inside size 90x150 cm and 120 cm deep
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , ncluding the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the ouses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
200mm o/d pipe
Construction of UGSR 25,000 ltr for SPT Treted water Storage water use for irragation perpous complete in all respects
Earth work in excavation of foundations of bridges culverts, buildings including handling of material with a combined lead of 15 metres dressing of bed and sides stacking the excavated soil from the edge of excavation and subsequent filling
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
(carrage material drive rate)
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75 kg/Sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer.
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/Sqm including pointing the joints with white cement and matching pigment etc., complete white cement slurry in joints including corners angles and beading. (carrage material drive rate)
12.5 mm thick cement plaster 1:5
Preparation of plastered or concrete surface for painting (including sand papering the surface) using Acryllic Wall Putty by applying two or more coats to get required finish including priming coat to make an even surface before applying Acrylic wall putty on new plastered surface. Complete as per specifications
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code: IS 2202-1 (1999)
Wire gauge Hollock wood door shutter without springs housed in chowkhat
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :250mm x 16mm
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect 4mm thick or 10.78 Kg/ sqm
Cold twisted deformed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).560mm i/d RCC man hole cover with frame as per ISI
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 63mm o/d pipe of 6 Kgf. / sqcm
160mm o/d pipe of 6 Kgf. / sqcm
Sub head- 3 Strome sewer System with Recharge well
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
200mm o/d PVC pipe of 4 Kgf. / sqcm
Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level removal of surplus spoils from the site of works upto chain (15 m), complete in all respects.
For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky
Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing
of beds and sides of chambers to exact profiles, 15cm thick C.C 1:6:12 in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar (as specified in item No. 29.49) complete and to the requirement of the engineer in charge
Single Road Gully chamber
Size 610mm x 457mm x 800mm
Providing & fixing in position CPVC.tank nipple of approved make to the approval of engineer in charge in PVC water storage tanks complete in all respects.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
CPVC. tank nipple 40 mm i/d
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Table Top (size 49 x 40 x 15 cm)
Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge)
Providing and fixing in position premium range paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.
Providing & Fixing in postion premium range Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Construction of External services like Sewer,Strom,Water Supply,UGSR & Tube well at Sports Stadium kaheru,Dhuri Distt Sangrur. Sub work-2
Sub head-1 Estate Water Supply system
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,wateing , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Including Excavation Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
90mm o/d pipe of 10 Kgf. / sqcm
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).
110mm o/d PVC pipe of 4 Kgf. / sqcm
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.
From bottom of well
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – incharge.200mm ominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200mm nominal size dia
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. 200mm internal diameter (weight 41.6 kg per metre) 8.0 mm thickness
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. 200mm internal dia
Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.200mm internal dia
Foot Rest for Manhole.Providing orange colour safety footrest of minimum 6mmthick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) com lete as per design.
Earth work in excavation in foundation and trenches as per CSR 6.6
Cement concrete 1:2:4 with stone ballast or shingle using concrete mixer volumetric type
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Extra for Circular work
12.5 mm thick cement plaster 1:2
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:- Bottom Layer :----- Broken stone, screened, cleaned and washed and graded from 50mm to 75mm (from Pathankot or approved equivalent quarry).
1st layer
Bajri (Coarse) screened, cleaned and washed and graded from 20mm to 25mm (from Pathankot or approved equivalent quarry).
2nd Layer
Third Layer :----- Bajri screened, cleaned and washed and graded from 6mm to 20mm (fromPathankot or approved equivalent quarry).
3rd Layer
Second Layer :----- Coarse sand screened, cleaned and washed and graded from 3mm to 6mm (from Pathankot or approved equivalent quarry).
4th Layer
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing and fixing RCC manhole covers 560mm i/d heavy duty
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Sub head- 4 Construction of UGSR 50,000 ltr for Drinking Use complete in all respects
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading i cluding stacking and setting the same to correct lines manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).560mm i/d RCC man hole cover with frame as per ISI
Machinery
3 Phase open well submersible pump Supplying &installation of approved make required capacity 3 phase, 50 Hz, 415V, open well submersible pump, with control panel starter with dry run protection, single phase preventer, connections, etc. as required as per specifications but excluding pipe and connection cable.7.5 HP head metre 12-32, discharge LPM 1620-420
Supplying lowering of 80 mm dia GI pipe as per IS 1239 (B - class) premim make such (as Jindal Hisar) including cost of specials such as tees, bends, sockets elbow etc, cutting, treading and testing in trenches in the ground. Complete in all respects
Providing and fixing of submerssible of 4 mm2 core cable, complete in all respect.
Providing installing, testing and commissioning of 1 no. control panel with closed transition star delta with enclosure consisting of electrical appliances such as contactor, furses, MCCB's over load relays , isolator switches wiring and connnections. Complete in all respect .
Sub head-5 InstallationTube Well 200 x 200 mmm , Submersible Pump with 643 lpm 70 mtr head for fillup of swimming pool with delivery 100 mm dia G.I B-Class , wire 6 mm with requisite cable and Panel board of approved make.
Boring/ Drilling
EYES BALL NOZZLES (6 KG) Floor Inlet Nozzle Body – ABS Fiber Color – White Flow Rate – 45M3/hr Multiple flow UV Protected Appreciated for long life. Connection 50mm/63mm Suitable for 10Kg & 6 Kg Pressure. Make By BLUE AID
Drilling of 500mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect.
Drilling of 500mm dia bore with Reverse Rotatry Rig Beyond 150 m depth BGL up to 300 Mtr
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.
Supplying & lowering MS Pipe as per IS 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strenght to lower the pipe into tubewell bore.
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – incharge.200mm ominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200mm nominal size dia
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. 200mm internal diameter (weight 41.6 kg per metre) 8.0 mm thickness
200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness
Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI Marked,duly
welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
200mm Steel Strainer (slot size 0.50mm)6.30 mm thickness
Supplying and fixing of bail plug of M.S. Pipe complete with inverted U-hook attached to the bottom plug complete in all respects.
200mm internal diameter (Weight 33.6 kg per meter) 6.4mm thickness.
Supplying & fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.
12v-20w 7 INCH Swimming Pool Under Water Light (12 V- 20W)LED Size - 7" Color – As per Requirement IP 68 Rating Make By BLUE AID WARRANTY – ONE YEAR
Supplying and fixing of well cap having threads to fix on housing pipe complete in all respects.
200 mm internal diameter
Supplying and fixing M.S. Clamps of size 150mm x 12mm made out of MS Flat 1.52m long, suitable to fit Housing Pipe including the cost Nut & Bolts of Suitable size complete in all respects.
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Supplying, fixing and lowering of stainless steel socket as per IS 8110: 2000 or latest, ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respects.
200mm internal diameter
Supplying at site wooden box of suitable size with Lid & lockign arrangement for preserving strata sample collected from the bore.
Supplying at quarry site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipe assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe)
Development and stabilizing of the tubewell with Air compressor or required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air Compressor 500 cfm at 600 PSI
Development and stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide & urenium etc.).
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect.
Supplying at site Tibba sand etc. including pouring and packing in the annular space between the pipes assembly and the bore above clay seal complete in all respect.
Providing & Fixing Clay seal in graval pack minimum 3 Mtr.(as per BIS code 2800-2019)
Providing & Fixing Sanitery Seal(as per BIS code 2800-2019)
Sterilization of Well (as per BIS code 2800-2019)
Pumping main
Providing, Laying, fixing & jointing of PVC pipes as per ISI-4985 (ISI marked with prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation & back filling (Including excavation).
90mm o/d PVC Pipe of 10kg/Sqm2
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI
Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14m
etre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
CPVC SDR 11 Pipe & fitting 32mm o/d
Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 40KVA/32KW without AMF Panel, Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be Water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable 53 BHP for giving a power rating as per ISO 8528- Part-1 (With CPCB-IV Norms upto date amendments) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled
Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete @ 3Kg Each (2x33kg = 66kg)
Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. 80 mm i/d check valve
Making of Cement concrete foundation of size 15' X 8' X 2' high for DG Set. The foundation start with Earth work in excavation 16' x 10' in foundations, Cement Concrete 1:5:10 with 40mm gauge stone agreegate mixing by mechanical means using concrete mixer volumetric type of size 15'x10'x0.75' , First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth size 15'x1.125'x 2' , Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres sizes 15.75'x5.75'x2', Shuttering for faces of concrete foundations and foundations, Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. sizes 15'x8'x0.5', Cold twisted deformed (Ribbed/for Steel Bar) Bar Fe 500 grade as per IS 1786-2008 complete in all respect as per site requirement and as desired by the Engineer in charge.
100mm i/d Sluice Valves flanged
Wiring fan point (Without fan box)
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. ZONE-6
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (2 no. each of size 0.9m x 0.9m
TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp)
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. on surface and providing angle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
C.P. brass toilet roll holder with flap
Providing & fixing in position Split AC 1.5 ton 5 Star invter type with all fitting and Steplizer out let Stand Electric Cable with drain pipe etc of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Providing, installing, testing and commissioning of 1 no. Electrically driven pumping set of reputed make capable of deleviring 519 lpm against a head of 65 mt. Complete in all respects
LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm)(FOR ATHELTIC SPORTS HALL) (Main Panel Incomer:- MCCB 160Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA =1 no. Outgoings:- MCCB 63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=6 no., MCCB 100Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=1 no. ,On Load Change Over swtich 160A FP = 1 no. ) Note:- The Panel excluding cost of MCCB's & Changeover
Sub head-1 Providing & fixing in position all weather swimming pool meachinery of filtaration system and cold & hot water system approved make complete in all respects.
Supply and erection of Hot dip galvanised, polygonal high mast with Fixed Head Gear Frame suitable for mounting 20 Nos. of 500W LED Flood Lights as required. The height of the mast from base upto top of head frame shall be 25.0 Mtrs.( 20 mt high mast + 5 mt fixed head frame) The mast has been designed with Fixed Head Frame shaft shall be structurally suitable to accommodate the requisite flood lights asymmetrical Distribution. with 15 degree Angle and considering base wind speed as per IS 875. High Mast Should Support Manrider Unit Made up of Steel Frame with Special Designed winch with Safety Rope Feature and Power Tool with Auto/Manual Operation with Safe Load Capacity of 300KG with lifting Speed 9m/minute.The Manrider unit must have Security lock & overload protection switch. The Lift must decend if there is no power and magnetic brake would be applied immediately. The Manrider system shall be independent unit with inbuilt Winch & Motor with Remote facility for operations of Manrider. Manrider must have anti fall arresting system with independent safety wire rope of min 8mm.The Soil Bearing Capacity is 10 T/m² at 2.5Mtr Below G.L and Density of Soil 1.44 T/m³, It should be the responsibility of the contractor to get the soil tested from authentic laboratory. All the Specifications and Safety Parameters complete in all respect including supply and installation of of Aviation Dome Light on the top of High Mast Pole as approved and desired by the Engineer-In-Charge at site.
Clearing herbaceous wild growth From open areas with shrub master and brush cutter, collection and disposal of undesirable material.
C.I FITTING INSIDE PUMP CHAMBER
(C) CONTROL CABLE Cable for supply:- Copper Conductor, 6.0 sq mm 5 core maximum Insulation/sheathed:- EPR Insulated & PCP sheathed/ PVC No of cables/ circuits per mast:-
1 No (3phase) flexible tpe multicore (D) WINCH/POWER TOOL Type/SWL of which:- Double drum (DD2GPB) tested from IIT/ any accredited Lab of Govt. of India approved with specific Load bearing capacity 750kg Method of operation:- Integral Motor Motor Capacity:- 2HP Power tool 3 phase electric moter reversible type 415/250 volt intergral (inside high mast) No of speeds:- Single speed 6 pole (E) STAINLESS STEEL WIRE ROPE Grade/ construction:- ASIS 316,7/19,SS 316,7/19 construction tested from IIT and of reputed make e.g Usha Martin or Equivalent. Number of Ropes:- 3 Nos Diametre of Rope (mm):- 8 mm dia Breaking load capacity of rope:- Minumum 3250 Kg per SS wire rope Foundation Bolts:- The foundation bolts included as same as supplied by the high Mast manufacturing company as per high mast standard with suitable size and length. Complete in all respect including connections, testing & other petty material required for commissioning as desired by the Engineer In Charge.
Supply and erection of LED type single dome aviation obstruction light with LED lamps on the existing 20 meter High Mast pole complete in all respect as approved and desired by the Engineer-In-Charge at site.
Public Health
Sub work-1
Sub head-1 Water Supply System
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
CPVC SDR 11 Pipe & fitting 20 mm o/d
100 mm internal diameter
Construction of Gravel Pit outside the Pump Chamber. (0.90m Dia.) as per standard design & drawings of public health department.
Size 75 mm x 75 mm
LE-1600 DIA MS FILTER (MILD STEEL) 1. SIZE - 1600 DIA Top Mount FRP FILTER With 6 Way Multiport Valve 6 way of Multiport Valve 1. Filter , 2. Backw
For 2000 ltr Water Tank
Providing, fixing and jointing CPVC Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
ash 3. Rinse , 4. Waste 5. Recirculation , 6. Closed Pipe Size ( 63mm PVC ) Working Pressure id 2.5 Kg cm2/36 psi. HEIGHT – 6.5 FEET LENGTH- 2 FEET Operating Temperature 43 Degrees WARRANTY - ONE YEAR
Providing and installing 100 mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks
2000 Ltr x4 nos.
Sub Head 6 Providing and installation sewerage treatment plant. 40 KLD Capacity
Providing & fixing in position CPVC.tank nipple of approved make to the approval of engineer in charge in PVC water storage tanks complete in all respects. .CPVC tank nipple 40 mm i/d
Providing and fixing in position automatic brass ball valves in tanks. 40 mm i/d Brass ball valve with plastic ball with G.I. socket
Providing & fixing in position Split AC 2 ton 5 Star invter type with all fitting and Steplizer out let Stand Electric Cable with drain pipe etc of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Construction of Multipurpose Sports Hall G+1 at Sports Stadium kaheru,Dhuri Distt Sangrur.
CPVC SDR 11 Pipe & fitting 20mm o/d
Union 40 mm o/d complete
Providing, fixing and jointing PVC Ball valves screwed with PVC ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes
25mm i/d PVC Ball valves
FILTER MEDIA (PER BAG 50 KG) FILTER MEDIA PACKAGING - 50 KG BAG MASH - 8-16 MASH- 16-32
TEST KIT Water Test Kit Basic Ph` & CI Test Kit Phinol Red - 15 mI Orthotodiline - 15 mI Make by blue Aid
1200 mm wide x 900 mm high x 400 mm deep Size
C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)
For 10000 ltr Water Tank
For 5000 ltr Water Tank
For 90mm o/d pipes
Providing and fixing in position CPVC Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
CPVC. tank nipple 40mm i/d
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
Door elbow 90 degree (all side socket)
32mm i/d Brass Ball valves
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty double sea
40 mm i/d Brass ball valve with plastic ball with G.I. socket
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Sub head-3 wall / Floor tile work & False Ceilling
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling using mechanical mixer for mixing of material
Elbow 90 Degree (All side socketed)
Door Elbow 90 Degree (All side socketed)
BlackGranitestonetiles15mmto20mmthickinskirting,risersofsteps,dadowallsandpillarslaidin12.5mmthickcementmortar1:3(1cement3coarsesand)andjointedwithneatcementslurry mixedwithpigment tomatchtheshadeofstone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball
Sub head-4 Sanitary Fixtures & CP Brass Fittings
Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge.
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Providing and fixing of FIRE EXTINGUISHER,CO2typeasper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.4.5 Kg. Capacity
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.
C.P. Brass khunti with 4 pegs
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 100 mm internal diameter
Design, Erection commisioning & testing of 1 Nos. 40 KLD STP based on SBR technology and pumping station with machinery for disposal of clear water and for flushing system complete as per manufacturer specification guideline and design & drawings will be submitted by Contractor as approve by entire satisfaction of Engineer-in-Charge Operation & Maintenance of STP for 1st years including all consumable material after completion of defect liability period
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325
TELESCOPIC ROD ALUMINIUM 8 FT. Telescopic Adjustable Rod Size – 8FT. Long. Body – Aluminum Thickness/Blue/Silver Make By BLUE AID
Sub head-7 Providing and fixing of Hockey Field Sprinkler System with boster pumps
Including Excavation Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
Providing, Laying , fixing & jointing of water pressure booster pumps system (ISI marked with the prior approval of Engineer-in-Charge)
40 AMP SMPS
Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc.
Drilling of 500mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL.
SUCTION VACCUM 6 KG Suction Nozzle Material –ABS Make - Blue Aid
Providing, Laying , fixing & jointing of sprinkler rotary pop system(ISI marked with the prior approval of Engineer-in-Charge)
Providing, Laying , fixing & jointing of Aluminium Rain Gun Sprinkler, Rotary Nozzles/ Rotators with pipe and stand (ISI marked with the prior approval of Engineer-in-Charge)
Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester
Ladder 3 Step Stainless Steel LadderPool Ladder is made with high quality Grade SS 304 Stainless Steel 38/42mm Tube for reliability Durability complete with anchoring fixtures. Make By BLUE AID
TCCA Trichloroisocyanuric Acid (PER KG)GRANULAR CHLORINE PACKAGING - 50 KG DRUM MAHS - 5 TO 8
Four Inchi Racing Lane (Per Mtr.) Swimming Pool Lane Rope Size – 4” with Hook Lane Size – 25 Mtr. Color –Blue/ Red/Yellow/White Rope Material – Stainless SteeRacing Lane Anti Wave
Anchor Hook Anchor Hook Material - ss ( 304 ) Racing Lane Hook
STARTING BLOCK Pool Starting block Material- Stainless Steel and Fiberglass Color – Blue Height - 400 mm Width – 2510 mm
c) Development & Stabilization of T/well with requisite compressor and as well as confirming to IS 2300 – 1979 with latest amendments.
Construction of 1 no Toilet block near Sports Hall at Sports Stadium kaheru,Dhuri Distt Sangrur. Sub work-1
OVER HEAD SERVICE RESERVOIR
Construction of one No. new RCC OHSR 75 KL Capacity having height of 19.00 mtr. upto from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilators single main hole cover lightening conductor etc. complete as described in schedule No.3 Providing and fixing D.I. K-9 D/F expansion joints conforming to (IS-9523 with lastest amendments) or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming (IS-9523 with lastest amendments) and D.I. K-9 D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI K-9 double flanged pressure pipes centrifugally cast as per IS 8329-2000 with latest amendments duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/f aluminium ladder inside, steel ladder outside tank of the OHSR including testing of soil bearing capacity tested from the reputated institute such as PEC Chandigarh/TTT Sector-26, Chandigarh, GNEC Ludhiana/ Thapar Institute of Engineering and Technology Patiala complete in all respects. SBC shall be tested in the presence of Engineer or his representative as per specifications. (The specifications & drawing are based on safe bearing capacity of soil is not less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. The contractor shall submit his own design, keeping in view seismic Zone-IV for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceil
ing Premium including overflow haudi, including providing and fixing Water Level indicating system and Construction of Plinth protection around OHSR with masonry toe wall including foundation depth, earthing, CC 1:8:16 with 40mm stone agregate and conglomerate floor 40mm with CC 1:2:4 as per DWSS specification. Providing & applying intergal crystalline slurry of hydrophilic in nature for water proofing management for vertical & horizontal surfaces and swellable type water stop tape.
Supplying and fixing M.S. Clamps of size 150mm x 12mm made out of MS Flat 1.52m long, suitable to fit Housing Pipe including the cost Nut & Bolts of Suitable size complete in all respects.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
SBD_Kaheru.pdf
Tender Documents • 29.98 MB
BOQ_313861.xls
BOQ • 2.54 MB
Download all tender documents and submit your bid