Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹52.6 LAccepted-Finance MAIN BAZAR GHUMARWIN DISTT BILASPUR HP 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | L 1 | Accepted-Finance L 1 | |
| 2 | L 2₹62.8 L+₹10.2 L (19.5%)Rejected-Finance | L 2 | Rejected-Finance L 2 |
Tender Value
Refer Docs
EMD Value
₹86,310
Closing Date
8 Jul 2021, 6:00 pmClosed
Executive Engineer Electrical HPPWD Division Una
Executive Engineer Electrical HPPWD Division Una
Providing E.I. there in
2021_PWD_49262_1
C/O I.P.D.Block at Civil Hospital at Ghumarwin D
Open Tender
Electrical Works
Item Rate
730 days
Una
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
₹86,310
28 Jul 2021
30 Jun 2021
9 Jul 2021
30 Jun 2021
8 Jul 2021
30 Jun 2021
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge .
Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge .
Group C.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge .
S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge .
12 modules (205mmx135mmx60mm)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge .
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge .
Supplying and fixing Computer board comprising 3 nos 5 amp modular switches , metal box 2 module for jack box and metal box 200 mmx150 mmx75 mm for 5 amp switchs and 5amp sockets comprising sheet cover for each 2module metal box , one no computer jack (RJ-45)with shutter including connections etc as required .Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge .
Supplying and fixing power plug socket with MCB protection 25 amp with plug top and 4 module box including making connection ,testin etc as required .Make:-SSK,CAT NO-psm -1501,HSN CODE -8336 /Anchor/L&T or its equivalent make.Make:-Legrand(Myrius),L&T(entice),Anchor (Roma plus )
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge .
2x2.5 Sq. mm.
2x6.0 Sq. mm.
2x16 Sq. mm.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge .
3x2.5 Sq. mm.
3x4.0 Sq. mm.
providing installation testing and commissioning of ceiling fan with step size socket size regulator , including wiring the down rods of standard length (up to 30 cm ) with 16/0.20 mm twin twisted flexible ,cotton braided copper cable including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc as required. Usha Technix plus ,BEE,Crompton -HS 5 Star,Bajaj-3 star or its equivalent not less than three star. rating.
ceiling fan 1200 mm
ceiling fan 1400 mm
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required.Make :-Usha ,Crompton or its equivalent as approved by Engineer-in - charge ..
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Exhaust Fan, Heavy duty, 300 mm sweep
Supplying and fixing of Exhaust fan (PVC ) with Louver shutter 300mm 1000RPM `1125 Air Delivery Ex fan on the existing opening including making the hole to suit the size of above fan making good the danmages complete with connections,testing and commissioning etc. as required.Make :-Usha ,Crompton or its equivalent as approved by Engineer-in - charge ..
S/F of Cabin/wall fan 400 mm Mist Air on the existing wall complete with connections,testing and commmissioning etc,as required.Make:-Usha,crompton or its equivalent as approved by Engineer-in - charge .
Supply and fixing exhaust fan louver shutter for 300/380mm exhaust fan on the existing wall painting including 12 mm thick wooden ply board for suitable size of exhaust fan hole.
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
Supplying and fixing of bulk head fitting LED 10 watt ,6500k ,(Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.Make -Panasonic (Model -PBHM01107)/PHILIPS/wipro as approved by Engineer-in-Charge
Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-Confrming to IS :64139 and tested /approved from the CPRI lab .Make:-EVA/Power control & system.
300 mm deep (nominal)
Providing and fixing 630 AMP , four pole, 415 volts, On-Load change over switch unit, panel mounting, front handle operation, including drilling holes in the cubical, making connections, etc. as required.Make:-L&T (CODE:-CO463000000),Legrand,Hagger as approved by Engineer-in -charge.
Supplying and fixing 4 pole MCCB 500 Amp Ics = 100% icu, 36 KA & @ 415 volts, 50 Hz with Microprocessor release Mtx2.0 & iTRP3 conforms to IS/IEC 60947-2 complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (CM930070000AG ),Legrand,Hagger , as approved by Engineer-in -charge.
Supplying and fixing 2 pole MCCB 63 Amp Ics = 100% icu, 25KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (EM90982OOHO),Legrand,Hagger , as approved by Engineer-in -charge.
Supplying and fixing 4 pole MCCB 63 Amp Ics = 100% icu, 25KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (CM91712OOHOOG,),Legrand,Hagger as approved by Engineer-in -charge.
Supplying and fixing 4 pole MCCB 125 Amp Ics = 100% icu, 25 KA & @ 415 volts, 50 Hz with thermal magnet in release complete with connection ,testing and commissioning etc as required .Make:-L&T Cat. No. (CM90642 OOMO)),Legrand,Hagger , or its equivalent as approved by Engineer-in -charge.
Supplying and fixing of Segregated tripple pole and neutral 12 way, sheet steel MCB distribution board 415 Volt on surface /recess with provision to mount MCCB as incomer with provision of 125 amp insulated phase bus bar /neutral bar with shroud/s /earth bar sticking saddles cement spill protector /colour coded interconnected wire set /cable ties/blanking plate and circuit indentification labels .SP/TP MCB as out going ,Powder painted including earthing etc as required.Make:-or its equivalent asapproved by Engineer-in - charge .
Supplying and fixing of Segregated tripple pole and neutral 8 way, sheet steel MCB distribution board 415 Volt on surface /recess with provision to mount MCCB as incomer with provision of 125 amp insulated phase bus bar /neutral bar with shroud/s /earth bar sticking saddles cement spill protector /colour coded interconnected wire set /cable ties/blanking plate and circuit indentification labels .SP/TP MCB as out going ,Powder painted including earthing etc as required.Make:-L&T (code-DBPGLOO8DD )/Legrand,Hagger as approved by Engineer-in charge.
Supplying and fixing of Segregated tripple pole and neutral 6 way, sheet steel MCB distribution board 415 Volt on surface /recess with provision to mount MCCB as incomer with provision of 125 amp insulated phase bus bar /neutral bar with shroud/s /earth bar sticking saddles cement spill protector /colour coded interconnected wire set /cable ties/blanking plate and circuit indentification labels .SP/TP MCB as out going ,Powder painted including earthing etc as required.Make:-L&T (code-DBPGLOO6DD )/Legrand,Hagger , as approved by Engineer-in charge.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Make:-L&T ,Legrand,Hagger as approved by Engineer-in -charge.
Double door-8 way
Double door-12 way
Double door-16 way
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required.Make:-L&T ,Legrand,Hagger as approved by Engineer-in -charge.
Supplying and fixing copper strip bus-bars suitable for 500 Amp. 415 volts capacity 4 No. each of cross-sectional area (50.80mmx6.35mm),in the existing enclosure with all accessories including connections etc. as required.Make:-L&T ,Legrand,Hagger as approved by Engineer-in -charge.
supplying and fixing CT coil 500/5 amp with burden of VA 15 accuracy class -1 Make:-Automatic Electric Ltd ,L&T,Legrand .
S/F indicator set RY &B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.
S/F Shock treatment chart on the existing wall etc as required including carriage of material within all leads and lift.
S/F rubber mat 1x2 meter long 12mm thick infront of main panel as required including carriage of material with in all leads and lift.
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:Make L&T Legrand,Heggar as approved by Engineer-in -charge
Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-:Make L&T Legrand,Heggar as approved by Engineer-in -charge
Double pole. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. :Make L&T Legrand,Heggar , as approved by Engineer-in -charge
40 Amps. Cat-A.
63 Amps. Cat-A.
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 25mm x 5mm copper strip in 40 mm dia. G.I. pipe from earth electrode etc. as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-Make :-KEI,Havells ,Polycab.
Armoured cable 400 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, unarmoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:Make :-KEI, Havells , Polycab.
Unarmoured cable 35 sq. mm (3.5 core)
Unarmoured cable 50 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size.Make :-KEI, Havells , Polycab.
Armoured cable 400 sq. mm (3.5 core)
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required.Make:- Racold,Jaquar,Usha ,minimum 3- star rating.
15 Liter capacity water heater (Cat-A)
25 Liter capacity water heater (Cat-A)
35 Liter capacity water heater (Cat-A)
Supplying and fixing of PVC PIPE 100 MM dia of size along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-Make:-Diplast/BEC.
Supplying and fixing SURFACE SQUARE type LED 36 watt 2feet X2 Feet ,6000k ,(Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficacy ≥100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.Make -JAQUAR (Model -LSVR01S036 SN )/Philips/Panasonic/wipro as approved by Engineer-in-Charge
Supplying and fixing surface mounting 1'x4' size 36 Watt LED surface mounted base light comprises of CRCA housing luminaire LED 36 watt 5700 K with five year warranty and it should be compatible with specification i.e Power Factor > .95,Harmonic Distortion<10% and efficacy ≥100 Lumens per watt suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.as required Make :-Panasonic (Code :-PBLM15368) ),Jaquar,Philips ,wipro as approved by Engineer-in-Charge.
Providing and fixing of surface mounted Luminaire LED 22 Watt batten ,having high Quality design aluminium extruded decorative end caps with five year warranty and it should be compatible with specification i.e. Power Factor >.9,Harmonic Distortion <10% and efficacy ≥ 100 Lumens per watt ,CRI> 80 suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.as required .Make :-Panasonic (PBTNM17228),Jaquar,Philips,wipro as approved by Engineer-in-charge.
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required.Make:-Philips/Jaquar/wipro.
Mirror light 460 mm, single lamp.(Category-A)
Supplying and fixing surface round type LED 20 watt ,6000k ,(Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficacy ≥ 100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.Make -Panasonic (Model -PDLM10206BS)/PHILIPS ,wipro as approved by Engineer-in-Charge
Supplying and fixing surface round type LED 10 watt ,6000k ,(Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficacy ≥ 100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.Make -Panasonic (Model -PDLM10103BS)PHILIPS ,wipro as approved by Engineer-in-Charge
Supplying and fixing LED. Lamp 9 watts E-27 base in the existing batten holder/pendent holder .Make:-Philips,Wipro.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.Make:-Diplast/BEC.
25 mm. dia
Supplying and drawing Lan cable Cat -6 solid copper conductor 4 pair protected with PVC Sheathed in existing surface /recessed steel/PVC Conduit as required.Make :Polycab,Finolex ,D-link.
Supplying and fixing D- link DGS-1008A 8 Port 10/100/1000M unmanaged switch standalone switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .Make:- D-Link/cisco
Supplying and fixing 1.5 ton invertor split type air conditioner Hot and Cold with vloltage stablizer 150v to 280 v ,(APC/Emerson/Numeric/Microtec) advanced filter ,E saver mode , quit mode, dual display ,auto clean ,anti bacteria filter jet Cool on/off timer sleep mode compressor cord less remote complete in all respect as per comprising to ISI with latest amendment suitable to operate on 230 volt /240 volt +_ 10 % AC supply capable to perform the function of cooling dehumidification air circulation ventilation and fitting in size of nominal cooling capacity and drain pipe 20 mm dia approximately 3mrs long 2 nos copper pipe with insulator for inlet and outlet approximatey 3 mtrs long and M.S power coated frame /stand for erection of out door unit of split type A.,C including carrigae of material with in all leads and lift.Make -Daikin (model:FTHT50), O Genral/Mitsubsi or equivalent as approved by the Engineer Charge.
Supplying and fixing 1.8/2.0 ton invertor split type air conditioner Hot and Cold with vlotage stablizer 150 V TO 290 V,(APC/Emerson/Numeric/Microtec) advanced filter ,E saver mode , quit mode, dual display ,auto clean ,anti bacteria filter jet Cool on/off timer sleep mode compressor cord less remote complete in all respect as per comprising to ISI with latest amendment suitable to operate on 230 volt /240 volt +_ 10 % AC supply capable to perform the function of cooling dehumidification air circulation ventilation and fitting in size of nominal cooling capacity and drain pipe 20 mm dia approximately 3mrs long 2 nos copper pipe with insulator for inlet and outlet approximatey 3 mtrs long and M.S power coated frame /stand for erection of out door unit of split type A.,C including carrigae of material with in all leads and lift.Make -Daikin (model:FTHT60), O Genral/Mitsubsi or equivalent as approved by the Engineer Charge.
Supplying and fixing of DLP 105x50 mmPVC adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap .Make:-Legrand ,MK or its equivalent as required complete in all respect .
Providing, laying and fixing of interconnecting copper piping with Nitrile tublar insulation AC indoor to outdoor for split type AC 1.5 ton and 1.8 AC as required complete in all respect.
Providing, laying and fixing of drian condensate drain water pipe with all necessary fitting for alll type A.C as required complete in all respect.
Supplying and fixing Surge protection device protection against indirect/direct lighting surges maxiumum dicharge current- I max upto 100 KA/ 3 pole+neutral Type 1+2 .Make :L&T(AUSP 123PN100),Legrand ,Hagger as approved by Engineer-in charge.
Supplying and fixing Nurse station terminal monitor with in built Digital display indicator panel with three year warranty for 20 beded set including call bell push button (bed side unit with jack), hand module for call bell push button, complete with all aceesories ,connection testing and commissioning etc as required.Make:-RS control device/Keyence/Supreme as per best satisfaction of Engineer-in-charge .
Supplying and fixing Nurse station terminal monitor with in built Digital display indicator panel with three year warranty for 14 beded set including call bell push button (bed side unit with jack), hand module for call bell push button, complete with all aceesories ,connection testing and commissioning etc as required. Make:-RS control device/Keyence/Supreme as per best satisfaction of Engineer-in-charge .
Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required.
Kalra Hardware and Electric Store
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .