| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-Finance | ₹18.0 L | L1 | Accepted-Finance L1 |
| 2 | L2₹18.4 L+₹43,775 (2.43%)Accepted-Finance | ₹18.4 L+₹43,775 (2.43%) | L2 | Accepted-Finance L2 |
| Sl No | Description | Qty | Unit | DAV SALES AND SERVICES PVT. LTD L1 | ARROW REFRIGERATION L2 |
|---|---|---|---|---|---|
| 1.00 | Supply of hi-wall type split AC units with heat pump for hot and cold applications meeting following requirements:
Rated Cooling capacity: Min. 5,000 W
Rated Heating capacity: Min. 5,000 W
Performance: ISEER≥4.40
Refrigerant: R-32
Approved makes: Daikin/ Mitsubishi/ O General/ equivalent (approved by the Bank)
Year of manufacturing: 2025 or later
Location: 16A colony: 8 Nos., 44B colony: 4 Nos., 30A colony: 4 Nos.
(Rate inclusive of GST, as applicable). | 16 | Nos. | 48,800 ₹7,80,800 Lowest | 49,000 ₹7,84,000 |
| 2.00 | Supply of hi-wall type split AC units for cooling only applications meeting following requirements:
Rated Cooling capacity: Min. 5,000 W
Performance: ISEER≥5.70
Refrigerant: R-32
Approved makes: Daikin/ Mitsubishi/ O General/ equivalent (approved by the Bank)
Year of manufacturing: 2026
Location: 44B colony: 2 Nos.
(Rate inclusive of GST, as applicable). | 2 | Nos. | 54,290 ₹1,08,580 | 53,600 ₹1,07,200 Lowest |
| 3.00 | Supply of hi-wall type split AC units for cooling only applications meeting following requirements:
Rated Cooling capacity: Min. 3,500 W
Performance: ISEER≥5.70
Refrigerant: R-32
Approved makes: Daikin/ Mitsubishi/ O General/ equivalent (approved by the Bank)
Year of manufacturing: 2026
Location: 30A colony: 12 Nos.
(Rate inclusive of GST, as applicable). | 12 | Nos. | 43,310 ₹5,19,720 Lowest | 48,000 ₹5,76,000 |
| 4.00 | Installation, testing & commissioning of hi-wall split AC units along with initial charge of refrigerant.
(Rate inclusive of GST, as applicable). | 30 | Nos. | 1,770 ₹53,100 Lowest | 2,800 ₹84,000 |
| 5.00 | Supply & laying of Insulated interconnecting copper piping with flexible multicore copper cable of appropriate size between indoor and outdoor units of 1.5 TR split AC units at item no. 1 & 2 above. No seperate measurement for the length of copper cable shall be done. (Rate inclusive of GST, as applicable). | 75 | RM | 1,550 ₹1,16,250 Lowest | 1,600 ₹1,20,000 |
| 6.00 | Supply & laying of Insulated interconnecting copper piping with flexible multicore copper cable of appropriate size between indoor and outdoor units of 1.0 TR split AC units at item no. 3 above. No seperate measurement for the length of copper cable shall be done. (Rate inclusive of GST, as applicable). | 110 | RM | 1,550 ₹1,70,500 Lowest | 1,600 ₹1,76,000 |
| 7.00 | Supply & fixing of duly powder coater MS heavy duty floor/ wall mount stand for outdoor units. (Rate inclusive of GST, as applicable). | 30 | Nos. | 850 ₹25,500 | 650 ₹19,500 Lowest |
| 8.00 | Drain piping: Supply and laying rigid Schedule 40 uPVC drain piping (along with all accessories such as tees, bends, couplers etc.) (Rate inclusive of GST, as applicable). | 135 | RM | 350 ₹47,250 | 205 ₹27,675 Lowest |
| 9.00 | Labour charges for dismantling of existing split ACs and shifting them to a loation within the colony premises as directed by the Bank's Engineer. (Rate inclusive of GST, as applicable) | 17 | Nos. | 3,200 ₹54,400 | 500 ₹8,500 Lowest |
| 10.00 | Buyack for old 1.5 TR nominal capacity split AC units (Rate inclusive of GST, but exclusive of TCS) | 17 | Nos. | 4,500 ₹-76,500 | 3,500 ₹-59,500 Lowest |
Tender Value
₹20.3 L
Closing Date
14 Aug 2026, 11:00 amClosed
Regional Director
Reserve Bank of India, Central Vista, Sector-17A, Chandigarh
SITC of split AC units for THH and VOF flats at Reserve Bank of India residential premises at sectors 16A, 30A and 44B in Chandigarh
2026_RBI_286835_1
RBI/CHD/Estate/2026-27/2/CPPP
Limited
Electrical Works
Works
Chandigarh
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
Chandigarh
19 Aug 2026
7 Aug 2026
17 Aug 2026
7 Aug 2026
14 Aug 2026
7 Aug 2026
10 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of hi-wall type split AC units with heat pump for hot and cold applications meeting following requirements:
Rated Cooling capacity: Min. 5,000 W
Rated Heating capacity: Min. 5,000 W
Performance: ISEER≥4.40
Refrigerant: R-32
Approved makes: Daikin/ Mitsubishi/ O General/ equivalent (approved by the Bank)
Year of manufacturing: 2025 or later
Location: 16A colony: 8 Nos., 44B colony: 4 Nos., 30A colony: 4 Nos.
(Rate inclusive of GST, as applicable). | - | Nos. | - | - |
| 2 | Supply of hi-wall type split AC units for cooling only applications meeting following requirements:
Rated Cooling capacity: Min. 5,000 W
Performance: ISEER≥5.70
Refrigerant: R-32
Approved makes: Daikin/ Mitsubishi/ O General/ equivalent (approved by the Bank)
Year of manufacturing: 2026
Location: 44B colony: 2 Nos.
(Rate inclusive of GST, as applicable). | - | Nos. | - | - |
| 3 | Supply of hi-wall type split AC units for cooling only applications meeting following requirements:
Rated Cooling capacity: Min. 3,500 W
Performance: ISEER≥5.70
Refrigerant: R-32
Approved makes: Daikin/ Mitsubishi/ O General/ equivalent (approved by the Bank)
Year of manufacturing: 2026
Location: 30A colony: 12 Nos.
(Rate inclusive of GST, as applicable). | - | Nos. | - | - |
| 4 | Installation, testing & commissioning of hi-wall split AC units along with initial charge of refrigerant.
(Rate inclusive of GST, as applicable). | - | Nos. | - | - |
| 5 | Supply & laying of Insulated interconnecting copper piping with flexible multicore copper cable of appropriate size between indoor and outdoor units of 1.5 TR split AC units at item no. 1 & 2 above. No seperate measurement for the length of copper cable shall be done. (Rate inclusive of GST, as applicable). | - | RM | - | - |
| 6 | Supply & laying of Insulated interconnecting copper piping with flexible multicore copper cable of appropriate size between indoor and outdoor units of 1.0 TR split AC units at item no. 3 above. No seperate measurement for the length of copper cable shall be done. (Rate inclusive of GST, as applicable). | - | RM | - | - |
| 7 | Supply & fixing of duly powder coater MS heavy duty floor/ wall mount stand for outdoor units. (Rate inclusive of GST, as applicable). | - | Nos. | - | - |
| 8 | Drain piping: Supply and laying rigid Schedule 40 uPVC drain piping (along with all accessories such as tees, bends, couplers etc.) (Rate inclusive of GST, as applicable). | - | RM | - | - |
| 9 | Labour charges for dismantling of existing split ACs and shifting them to a loation within the colony premises as directed by the Bank's Engineer. (Rate inclusive of GST, as applicable) | - | Nos. | - | - |
| 10 | Buyack for old 1.5 TR nominal capacity split AC units (Rate inclusive of GST, but exclusive of TCS) | - | Nos. | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
TenderCPPP.pdf
Tender Documents • 1.12 MB
BOQ_334699.xls
BOQ • 0.40 MB
Extensions.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .