Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹30.4 L+₹2.3 L (8.22%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹31.0 L+₹2.9 L (10.4%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹32.6 L+₹4.5 L (15.9%)Rejected-AOC HIMACHAL BUILDING SHOP NO 10 CD BARFYWALA ROAD JUHU LANE ANDHERI W MUMBAI 400058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹33.3 L+₹5.2 L (18.5%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
6 Mar 2023, 6:00 pmClosed
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
REPAIR AND REPLACEMENT TO STREET LIGHTS, SECURITY LIGHT, DG SETS LT PANELS CABLES WITH OTHER MISC CONNECTED WORKS AT NCHC POWAI AND ULHASNAGAR UNDER GE(NW) BHANDUP
2023_MES_578052_1
8252/B
Open Tender
Civil Works
Item Rate
270 days
POWAI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹86,000
Yes
28 Mar 2023
30 Jan 2023
7 Mar 2023
30 Jan 2023
6 Mar 2023
20 Feb 2023
Amount
Taking down unsv LED street light fitting and Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Taking down unsv LED street light fitting and Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Taking down unsv LED street light fitting and Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistantcomplete with driver and lamp complete all as specified and directed.
Taking down unsv LED security light fitting and Supply and fixing LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and drawing through conduit pipe on pole/ wall for making connectiion to the light fittings 3 Core, Copper cable,PVC insulated and sheathed heavy duty 1100 volt grade multistranded copper conductor (FRLS) cable 1.5 sqmm complete all specified and directed
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 140 x 140 x 95 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to wall complete all as specified and directed.
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 200 x 140 x 95 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to wall complete all as specified and directed.
Taking out old unsv steel tubular sewaged pole/PCC pole with all necessary earth work complete all as specified and directed.
Supply and fix in repairs pipe bracket made out of 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Supply and fix in repairs pipe bracket made out of 25 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Taking down unserviceable LT cable complete all as specified and directed
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm x 4 core complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm x 4 core complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
Supplying and laying High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 of size 32 mm laid in trenches for cable protection complete all as specified and directed.
M&L in repairs of GI pipe 80 mm dia light grade with all fittings for cable protection complete all as specified and directed.
M&L in repairs of GI pipe 50 mm dia light grade with all fittings for cable protection complete all as specified and directed.
Supply and fix in repairs of MCCB 63 to 100 Amps 3 Pole, abjustable type, 50Hz with breaking capacity 16 KA, as per site requirement with sheet metal enclosure and complete all as specified and directed.
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint all as specified and directed.
M & L For PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation filling & mass concrete complete all as specified and directed.
M & L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in coping / fountation of poles including use of form work and finishing all exposed faces of concrete as per clause 4.11.66 (a) & (d) of SSR Part-I complete all as specified.
Supply and fixing in repairs analog timer switch 3P module, 24 Hrs programme complete all as specified and directed.
M&L for LT straight through joint heat shrinkable kit suitable for 3 ½ / 4 core of size 10 to 16 sqmm underground cable complete all as specified and directed.
M&L for LT straight through joint heat shrinkable kit suitable for 3 ½ / 4 core of size 25 to 50 sqmm underground cable complete all as specified and directed.
M&L for LT straight through joint heat shrinkable kit suitable for 3 ½ / 4 core of size 70 to 95 sqmm underground cable complete all as specified and directed.
M&L for LT straight through joint heat shrinkable kit suitable for 3 ½ / 4 core of size 120 to 185 sqmm underground cable complete all as specified and directed.
S&F 7 metre long hot dipped galvanised octagonal poles with top A/F 70 mm bottom A/F 130 mm ,made out of 3 mm thick HT sheet alongwith base plate of size 220x220x12mm ,including 1500 mm long single/double arms bracket made out of 48 mm dia,GI pipe,M20 in PCD 205 mm,700mm long and projected 100mm,"J" type EN8 grade set of 4 Nos foundation bolts along with tempalates,also including provision of the followings :- a)MCB,SP,6A,230v,B series,10KA mounted on and including 3 mm thick plastic laminated sheet-01 No. b) 4 way connector ,bolt type having locking arrangement,weather proof and water proof control space: 01 No. Notes :- a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete. b) The rate quoted shall also be deemed to include the cost for connecting with including suitable lugs of the existing incoming and outgoing LT UG cable of any size in the pole box of new octagonal pole. c) The concrete for foundation ,Reinforced and form work will measured and paid seperately. d) The existing light fittings retrived from relevant items here in before shall be refixed at the pole and the quoted rate shall also be deemed to include the cost of above mentioned element. e) The excavation and earth work for foundation of pole shall be measured and paid separately in case the new poles are provided at different locations as compared to old poles dismantled vide relevant items here in before .
M&L for TMT steel bars 10 mm dia and over in reinforcement cut to length,bent to shape required,including cranking bending spirally forhooping for coloumns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm di or ecuring with clips etc, complete all as specified and directed
M&L for TMT steel bars but 5mm dia and over upto and including 10mm dia as in strirups, spacers, binders cut to length,bent to shape required,including cranking bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm di or ecuring with clips etc, complete all as specified and directed
M&L Carrying out 'B' check for 200 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
M&L Carrying out 'B' check for 160 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
M&L Carrying out 'B' check for 125 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
M&L Carrying out 'B' check for 100 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
M&L Carrying out 'B' check for 82.5 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
M&L Carrying out 'B' check for75 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
M&L Carrying out 'B' check for 50 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
M&L Carrying out 'B' check for 45 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
M&L Carrying out 'B' check for 7.5 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
Supply only Engine oil grade 20 W 40 for incorporation against "B" check complete all as specified and directed.
Supply only coolant for DG set radiator complete all as specified and directed.
Supply only fuel filter & oil filter suitable for 200 KVA DG set capacity as per existing size complete all as specified and diretced,
Supply only fuel filter & oil filter suitable for 160KVA DG set capacity as per existing size complete all as specified and diretced,
Supply only fuel filter & oil filter suitable for 125 KVA DG set capacity as per existing size complete all as specified and diretced,
Supply only fuel filter & oil filter suitable for 100 KVA DG set capacity as per existing size complete all as specified and diretced,
Supply only fuel filter & oil filter suitable for 82.5 KVA DG set capacity as per existing size complete all as specified and diretced,
Supply only fuel filter & oil filter suitable for 75 KVA DG set capacity as per existing size complete all as specified and diretced,
Supply only fuel filter & oil filter suitable for 50 KVA DG set capacity as per existing size complete all as specified and diretced,
Supply only fuel filter & oil filter suitable for 45 KVA DG set capacity as per existing size complete all as specified and diretced,
Supply only fuel filter & oil filter suitable for 7.5 KVA DG set capacity as per existing size complete all as specified and diretced,
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 200 KVA DG set complete all as per specified and directed.
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 160 KVA DG set complete all as per specified and directed.
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 125 KVA DG set complete all as per specified and directed.
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 100 KVA DG set complete all as per specified and directed.
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 82.5 KVA DG set complete all as per specified and directed.
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 75 KVA DG set complete all as per specified and directed.
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 50 KVA DG set complete all as per specified and directed.
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 45 KVA DG set complete all as per specified and directed.
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 7.5 KVA DG set complete all as per specified and directed.
S&F in repairs of fan belt suitable for DG set of 45 to 200 KVA capacity complete all as specified and directed.
S&F in repairs of fan belt suitable for DG set 7.5 KVA capacity complete all as specified and directed.
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 200 KVA complete all as specified and directed.
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 160 KVA complete all as specified and directed.
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 125 KVA complete all as specified and directed.
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 100 KVA complete all as specified and directed.
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 82.5KVA complete all as specified and directed.
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 75KVA complete all as specified and directed.
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 50KVA complete all as specified and directed.
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 45KVA complete all as specified and directed.
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 7.5 KVA complete all as specified and directed.
Repairing radiator for 160 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and refixing on the chasses complete all as specified and as directed.
Repairing radiator for 82.5 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and refixing on the chasses complete all as specified and as directed.
Repairing radiator for 75 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and refixing on the chasses complete all as specified and as directed.
Repairing radiator for 50 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and refixing on the chasses complete all as specified and as directed.
Repairing radiator for 7.5 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and refixing on the chasses complete all as specified and as directed.
S&F in repairs solenoid switch for DG set upto 200 KVA capacity complete all as specified and directed.
Repairs of AMF Panel of 160 KVA DG set as per the site requirement complete all as specified and as directed.
Material and labour for disconnecting / dismantling of self starter from DG set 82.5 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc, greasing and connecting , testing complete all as specified and as directed.
Material and labour for disconnecting / dismantling of self starter from DG set 75 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc, greasing and connecting , testing complete all as specified and as directed.
Material and labour for disconnecting / dismantling of self starter from DG set 50 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc, greasing and connecting , testing complete all as specified and as directed.
Material and labour for disconnecting / dismantling of self starter from DG set 7.5 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc, greasing and connecting , testing complete all as specified and as directed.
Material and labour for disconnecting / dismantling of self starter from DG set 16KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc, greasing and connecting , testing complete all as specified and as directed.
Material and labour for servicing and overhauling of dynamo including replacement of unsv parts such as carbon brush, armature winding, varnishing of coil and reassembling and fitted with the engine including testing complete of capacity 12 volts complete all as specified and directed.
Material and labour for painting of DG sets of 75 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Material and labour for painting of DG sets of 160 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Material and labour for painting of DG sets of 50 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Material and labour for painting of DG sets of 7.5 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Supply and fix in repair unserviceable Maintenance free battery 180 Ah 12 volts complet all as specified and directed. Make Exide/Amron
Supply and fix in repair unserviceable battery lead copper lead of 25 Sqmm copper conductor, 2 Mtr length with brass terminal complete suitable for DG set 7.5 KVA to 160 KVA all as specified and directed. Make Exide/Amron
Dismantling and calibrating the fuel injector assembly from authorised dealer of capacity 82.5 KVA DG set complete allas specified and directed
Dismantling and calibrating the fuel injector assembly from authorised dealer of capacity 160 KVA DG set complete allas specified and directed
Dismantling and calibrating the fuel injector assembly from authorised dealer of capacity 75 KVA DG set complete allas specified and directed
Dismantling and calibrating the fuel injector assembly from authorised dealer of capacity 50 KVA DG set complete allas specified and directed
Dismantling and calibrating the fuel injector assembly from authorised dealer of capacity 7.5 KVA DG set complete allas specified and directed
Supply and fixing in repairs electronic based generator controller unit suitable for 50 KVA generator set including testing complete all as specified and as directed.
Dismantling the UNSV Automatic voltage Regulator of the 160 KVA DG set and replacement of the same with new as per existing make and size and fixing and testing complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm x 3.5 core complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm x 3.5 core complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm x 3.5 core complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 75 sqmm x 3.5 core complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm x 3.5 core complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sqmm x 3.5 core complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 sqmm x 3.5 core complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 185 sqmm x 3.5 core complete all as specified and directed.
Supply and laying in repair cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 sqmm x 3.5 core complete all as specified and directed.
M&L in repairs of GI pipe 100 mm dia light grade with all fittings for cable protection complete all as specified and directed.
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed.
Supply and spreading sand in trenches as cushioning to under ground cable on top and bottom of cable complete all as specified and directed.
Supplying and laying High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 of 50 mm bore pipe laid in trenches for cable protection complete all as specified and directed..
Supply and fix in repairs of MCCB 100 Amps 3 Pole, with breaking capacity 16 KA, as per site requirement and complete all as specified and directed.
Supply and fix in repairs of MCCB 125 Amps 3 Pole, with breaking capacity 16 KA, as per site requirement and complete all as specified and directed.
Supply and fix in repairs of MCCB 63 Amps 4 Pole, with breaking capacity 16 KA, as per site requirement and complete all as specified and directed.
Supply and fix in repairs of MCCB 160 Amps 4 Pole, with breaking capacity 36 KA, as per site requirement and complete all as specified and directed.
Supply and fix in repairs of MCCB 200 Amps 4 Pole, with breaking capacity 36 KA, as per site requirement and complete all as specified and directed.
Supply and fix in repairs of MCCB 250 Amps 4 Pole, with breaking capacity 36 KA, as per site requirement and complete all as specified and directed.
M & L in repairs of ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps fixing in existing LT panel with including provision of the followings (a) Conform IEC 60947-2 &3, ICU=ICS=50kv & ICW(1sec)=4 KA (b) ET range of trip system (c) 4 pole breakers equipped with adustable neutral protections (d) ensure safty with realy to close contact, multiple locking option safty shutter etc (e)Suitable for copper / aluminium terminations (f) Optional spreaders enableing ease of connection with cables and complete all as specified and directed.
Taking out old rusted steel tubular sewaged pole/PCC pole (street light) with all necessary earth work complete all as specified and directed
S&F 8 metre long hot dipped galvanised octagonal poles with top A/F 70 mm bottom A/F 130 mm ,made out of 3 mm thick HT sheet alongwith base plate of size 220x220x12mm ,including 1500 mm long double arms bracket made out of 48 mm dia,GI pipe,M20 in PCD 205 mm,700mm long and projected 100mm,"J" type EN8 grade set of 4 Nos foundation bolts along with tempalates,also including provision of the followings :- a)MCB,SP,6A,230v,B series,10KA mounted on and including 3 mm thick plastic laminated sheet-01 No. b) 4 way connector ,bolt type having locking arrangement,weather proof and water proof control space: 01 No. Notes :- a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete. b) The rate quoted shall also be deemed to include the cost for connecting with including suitable lugs of the existing incoming and outgoing LT UG cable of any size in the pole box of new octagonal pole. c) The concrete for foundation ,Reinforced and form work will measured and paid seperately. d) The existing light fittings retrived fromrelevantitems here in before shall be refixed at the pole and the quoted rate shall also be deemed to include the cost of above mentioned element. e) The excavation and earth work for foundation of pole shall be measured and paid separately in case the new poles are provided at different locations as compared to old poles dismantled vide relevant items here in before
M & L for painting of synthetic enamal paint for panel board other MS steel suface, preparation oil painted surface by scraching and apply one coat of red oxide and one coat of synthetic enamel paint and complete all as specified and directed
M & L Structural steel, rolled section such as joist, beam, channel, angle, Tee, in available lengths for stuctural fram of panel complete all as specified and directed
Supply and fix in repair CT's in panel board of current ratio 500 A/5A, nessecary connection to Ameter and complete all as specified and directed
Supply and fix in repair indication lamp, single phase 240A/ 240 VAC of colourRed, Green, Yellow with nessecary connection and complete all as specified and directed
M&L for finding faults of LT UG XLPE cable of any size and any length upto 240 Sqmm by using computerised / primary current injection method / any other method as directed by the Engr-in-charge and locating fault, cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing complete all as specified and directed. Note: Joints shall be paid for separately.
Supply and fix in repair Bolted 63 Amp HRC diode fuse links sutable for existing panel board and complete all as specified and directed.
Supply and fixing on load change over switch of capacity 250 Amp, 415 V, 4 Pole, front handle operated,suitable for wall mounting in steel metal enclouser and complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 106460.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Radha Engineering Services
ORIENT ELECTRIC CO
M/s PIONEER CONTRACTORS
industrial suppliers
Anjali Constructions
M/s Mukesh Engineers
GRAND SERVICES
M/s ASPIRE ENGINEERING ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .