| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.8 LAccepted-AOC 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L-1 | Accepted-AOC Being L-1 Bidder | |
| 2 | L-2₹26.4 L+₹68,896.10 (2.68%)Rejected-Finance | L-2 | Rejected-Finance Not being L-1 bidder. | |
| 3 | L-3₹27.2 L+₹1.5 L (5.80%)Rejected-Finance B 814 8TH FLOOR B G TOWER OPP DELHI GATE SHAHIBAUG ROAD AHMEDABAD 380004 | AHMADABAD | GUJARAT | 380004 | L-3 | Rejected-Finance Not being L-1 bidder. | |
| 4 | L-4₹30.7 L+₹5.0 L (19.4%)Rejected-Finance 2ND FLOOR 2B SORAJ ESTATE ULUBARI K C PATOWARI ROAD ULUABRI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | L-4 | Rejected-Finance Not being L-1 bidder. | |
| 5 | Rejected-Technical 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | - | Rejected-Technical Not meeting NIT Criteria. |
Tender Value
₹30.8 L
Closing Date
31 Aug 2021, 6:00 pmClosed
AGM (E-E)-II
Airports Authority of India, Imphal International Airport
Provision Of Energy Efficient Split Type Air Conditioners And Water Cooler For Various Locations In Place Of Old ACs At Imphal International Airport (Year 2021-22).
2021_AAI_85320_1
AAI/IMP/AGME (E)/eNIT-CW-05/ACs/2021-22
Open Tender
Electrical Works
Works
60 days
Imphal
As per NIT
14 documents required · 14 mandatory
₹1,180
Exempted
23 Sept 2021
18 Aug 2021
2 Sept 2021
19 Aug 2021
31 Aug 2021
19 Aug 2021
19 Aug 2021 - 24 Aug 2021
Amount
Supply of 1.5 TR, Highwall Split A/Cs, 5 star rating, Inverter Split Units with R410a / R-32 Gas. (Both indoor and outdoor units), complete with filters, DX cooling coils connected to DX condensing units,Condenser coil- Copper, including remote control operation for temperature adjuistment, indoor unit blower speed, swing adjustment, auto restart, sleep mode turbo mode, with LED display for temparalure i/c standard lengh of copper refrigerant pipe, copper electrical cable & drain pipe etc. Complete as per technical specifications.
Supply of 2 TR, Highwall Split A/Cs, 5 star rating, Inverter Split Units with R410a / R-32 Gas. (Both indoor and outdoor units), complete with filters, DX cooling coils connected to DX condensing units,Condenser coil- Copper, including remote control operation for temperature adjuistment, indoor unit blower speed, swing adjustment, auto restart, sleep mode turbo mode, with LED display for temparalure i/c standard lengh of copper refrigerant pipe, copper electrical cable & drain pipe etc. Complete as per technical specifications.
Supply of 2 TR, Cassette A/Cs, 5 star rating, Inverter Split Units with R410a / R-32 Gas. (Both indoor and outdoor units), complete with filters, DX cooling coils connected to DX condensing units,Condenser coil- Copper, including remote control operation for temperature adjuistment, indoor unit blower speed, swing adjustment, auto restart, sleep mode turbo mode, with LED display for temparalure i/c standard lengh of copper refrigerant pipe, copper electrical cable & drain pipe etc. Complete as per technical specifications.
Supply, installation, testing and commisssioning of water cooler suitable for operation on 230 V, 50 Hz AC supply with RO + UV purification, 80 ltrs storage capacity and 60 LPH water flow rate through the faucets, etc. complete as per technical specification.
Installation testing and Commissioning of following capacity Airconditioning Unit Including making of necessary hole on concrete/brick wall and making good the same i/c providing suitable size PVC pipe for drawing the /drain pipe and wire etc through the concrete/brick wall as required.
1.5 TR High wall Split AC (Invertor type)
2 TR High wall Split AC (Invertor type)
2 TR Cassette AC (Invertor type)
Supply, fixing, testing and commisssioning of wall mounting type automatic electronic voltage stablizer suitable for split Air Conditioners single phase and auto voltage range of 180-270 V with high/low voltage cut off on delay etc complete as required.
Supply of following sizes XLPE insulated PVC sheathed unarmoured copper conductor flexible cable etc, complete as required.
4 core X 2.5 Sqmm.
Supply, installation testing and commisssioning of extra refrigent copper pipe suitable for 1 TR, 1.5 TR and 2 TR invertor type AC including leakage testing and providing fixing of insulation, soldering, necessary clamping arrangement etc. of following size as reqiured.
Supply & fixing of 6mm thick Nitrile Rubber Tube Insulation for 1 TR, 1.5 TR and 2 TR refrigerant piping to prevents condensation, reduces energy losses and protects against frost on pipes of following sizes.
Supply, installation testing and commisssioning of UPVC pipes complete with fittings and 'U' traps for condensate drain piping with supports and thermal insulation as per specifications of following sizes.
Supply, installation testing and commisssioning of MS frame L/chair type stand for fixing outdoor units of 1 TR, 1.5 TR & 2 TR split A/Cs complete as required.
Supply of following sizes XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required.
4 core X 25 Sqmm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 25 sq. mm (28mm)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required .
4 Way TPN, Double Door
Supplying and fixing of following amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supply, installation, testing and commissioning of 20 ampere Modular Socket Box with inbuilt 20 ampere SP, C curve Mini MCB, Plastic enclosure & unbreakable heavy duty with ISI mark plug top and necessary connection complete as reqiured.
Dismantling of different capacity existing A/Cs & Water Cooler i/c transportation of dismantled items upto AAI dismantle store complete as require.
Mercantile Agency
jaydeep agency corporation
RS COOLING APPLIANCES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .