Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.7 LAccepted-AOC | L-1 | Accepted-AOC lowest bidder | |
| 2 | L-2₹31.5 L+₹44,163.55 (1.42%)Rejected-AOC | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹32.4 L+₹1.4 L (4.46%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹34.8 L+₹3.7 L (12.0%)Rejected-AOC | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹34.9 L+₹3.8 L (12.4%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
₹46.5 L
EMD Value
₹92,960
Closing Date
30 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Tanuj Bagla, IDSE
GE Kaluchak Pin-900673 C/O 56 APO
CONVERSION OF LT OVERHEAD CONDUCTOR TO LT UNDERGROUND, SPL REPAIR TO ELECTRIFICATION AND PROVN OF LIGHTENING CONDUCTOR AT RATNUCHAK MIL STN UNDER GE KALUCHAK
2023_MES_616571_1
GE/KC/NIT-31/2023-24
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹92,960
Yes
20 Nov 2023
31 Aug 2023
7 Oct 2023
31 Aug 2023
30 Sept 2023
14 Sept 2023
31 Aug 2023 - 7 Sept 2023
Amount
Dismantling of cross arms of MS channel or angle iron etc. from pole, complete all as specified & directed.
Dismantling of ACSR conductor of any type & size from over head line or LT poles, complete all as specified & directed.
Dismantling of LT insulators of any type, shape & size, complete all as specified & directed.
Taking out old/ unserviceable damaged existing concrete poles of any size/length from existing position after disconnection of electric supply including necessary excavation, demolition of PCC foundation and removing the same from site, complete all as specified & directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Excavation in trenches n.exc 1.5 mtr wide exc 1.5 mtr in deep but not exceeding 3.0 mtr deep and getting out for foundation of poles etc. in any type of soil, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included the cost of excavation.
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed.
PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in stay etc including necessary form work, complete all as specified & directed.
PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed.
Steel tubular swaged poles in vertical position swaged type 410-SP-31, 9 Mtr long, ISI marked, in one piece, complete with cast iron base plate, finial taper plug, bolts, nuts washers and screws as required, drilling of holes for continious earth wire as specified duly painted with two coats of aluminium paint over a coat of red oxide primer above ground level including painting throughout internally & below GL (externally) with two coats of bituminous paint, numbering of poles with cut stencil lettering in size 6mm thick, 50mm high and white and black strips of size 30cm width each with synthetic elamel paint upto 1.5m above coping etc, complete all as specified and directed. Note:- 1. Earth work and PCC will be measured and paid for seperately under appropriate items.
Stay Assembly using stay rod of 20mm dia with complete accessories as shown in Electrical Plate No 1 of SSR 2009 Part-I such as loop type insulator, porcelain, vitreous white/ brown or green, large size with overall dimensions 90x140mm clearance of hole 25.5mm, stay wire of size 7/4.00mm, stay plate 300x300x6mm thick, 14mm dia 400mm long GI stay bow, 20mm dia 1.80m long GI stay rod, galvanized thimble, etc. including dismantling of old unserviceable stay assembly, complete all as specified & directed. Note :- Earth work and PCC shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes, testing after completion including disconnecting and taking out old unserviceable cable, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
All as per Srl item No.12 above but cross-sectional area 95 Sqmm 3.5 core.
All as per Srl item No.12 here-in-before but cross-sectional area 70 Sqmm 3.5 core.
All as per Srl item No.12 here-in-before but cross-sectional area 50 Sqmm 3.5 core.
All as per Srl item No.12 here-in-before but cross-sectional area 35 Sqmm 3.5 core.
All as per Srl item No.12 here-in-before but cross-sectional area 25 Sqmm 3.5 core.
All as per Srl item No.12 here-in-before but cross-sectional area 16 Sqmm 4 core.
All as per Srl item No.12 here-in-before but cross-sectional area 16 Sqmm 2 core.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 10 Sqmm twin core cable flat or circular including taking down old unserviceable service connections, complete all as specified & directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 16 Sqmm twin core cable flat or circular including taking down old unserviceable service connections, complete all as specified & directed.
Cable junction box, outdoor type, IP-66 insulated made out of PC-GFS polycarbonate, black colour (RAL 9011), environment friendly, recyclable, weatherproof (UV due to solar radiation, protected against rain water, temperature resistant), halogen & silicon free, anti-acid, anti-corrosive for outdoor installation of street light of size 225mm x 295mm x 122mm fixed on pole complete with links/terminals suitable for in/out cable size upto 35sqmm 3.5 core including MCB SP 10 Amps, 10KA, PVC insulated weather proof twin core 2.50 sqmm (nominal area) aluminium conductor cable, 1100 volts grade, drawn in & including PVC conduit of suitable size with clamps (3 Nos), nuts, bolts etc from junction box to street light connection necessary flat iron clamps with nuts, bolts & washers for fixing on pole & taking down old unserviceable junction box, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer after preparation of surfaces, complete all as specified & directed.
Shackle type insulator porcelain vitreous white, brown or green 75mm high and 90mm dia for conductor of working pressure 1100 volts including galvanised mild steel straps of 31x5mm size, 14mm dia insulator bolts, washers and nuts, complete all as specified & directed.
ACSR conductor of any size drawn straight horizontal on over head lines on existing poles including binding with insulators & 15mm dia PVC separator at equal intervals, weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers etc, complete all as specified & directed.
Re-stretching, restraining ACSR conductor laid over, OH LT line on steel/PCC poles after removing the binding from insulators, lowering the ACSR conductor or broken OH line due to any reason, jointing the broken conductor, Re-binding the ACSR with insulators including providing binding wire, jumpering & connecting the existing service cables after re-stretching/ Re-straining to OH line & removing unavoidable sag in the lines, complete all as specified & directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of LT over head line feeders and removal of the trimmed branches of trees, complete all as specified & directed. Notes : (a). Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. (b). The cutting / trimming of tree branches shall be done to at least 3.00 metre from the outer conductor of OH line. (c). The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Galvanised iron tube 50mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound including taking down old unserviceable tube, complete all as specified and directed.
Cutting/ boring of road/hard standing to a size of 30cm in width and not exc 90 cm in depth for laying of protection pipe / water line/ cable including returning, filling in, spreading, romoval of surplus soil and providing 100mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate on top, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included the cost of excavation.
Preparation of old painted steel surfaces of steel tubular swaged/rail poles of 9M/ 11M long including brackets, clamps, channel and cross arms by cleaning of oils, lubricants, gresse etc complete above PCC coping, applying two coats of aluminium paints superior quality of approved make on surfaces exposed to view and applying two coats of synthetic enamel paint in zebra pattern with aluminium and red colour combination upto 1m height above PCC coping, writing MES No of poles (number size shall be 25mm and lettering shall be 40mm), complete including applying two coats of white wash on exposed concrete surfaces of coping after preparation of old concrete surfaces of coping, complete all as specified & directed.
Supply, installation, testing and commissioning weather proof outdoor type LT electrical feeder piller box, factory fabricated and CPRI approved, made out of not less than 3mm thick CRCA sheet, vermin/ dust / weather proof with rain protection canopy on top, aesthetically designed, having at least IP-54 protection with front and rear side openings overall size 900 x 600 x 300mm including busbar chamber, contineous earth busbar, Aluminium strip 600 mm long of size 400 A rating mounted on 1100 V epoxy insulators and including MS angle iron base frame of size 50x50 x6 mm 30 cm grouted in ground & 60 cm above GL with necessary excavation, PCC 1:2:4, type B2 foundation, complete with locking arrangement, powder coated in postmen red color shade chemical for rust protection complete with electrical wiring,
1100V Danger notice board on front of the panel with PVC insulated sheathed stranded aluminium conductor cable of adequate size with suitable lugs, bolts, washers and duly cross marked with paint on front side and with proper locking arrangement complete connecting incoming & outgoing connections the panel shall be complete with instrumentation such as metering & indication and CT's, comprising of the following:- (a) MCCB 400 Amps, 4 pole with breaking capacity 36KA (Adjustable thermal & magnetic release) - 01 No (Incomer) (b) Multifunctional meter - 01 No (c) CT'S 250/5 - 01 Set (d) Indicator lamp RYB - 01 Set
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth strip 32x6mm size (up to 7.5m in length from earth plate) by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised steel strip of 32 x 6mm to connect earthpit to electrical equipment room, complete all as specified & directed.
Air termination single pointed aluminum rod 12mm dia and 300mm long, complete all as specified & directed.
Test terminal box of size 175x150x100mm made of 2mm thick hot dip galvanised sheet, drilled and screwed including 4 Nos 125mm long hexognal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed, complete all as specified & directed.
Galvanized iron water tubing, light grade, 25mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Galvanized iron water tubing, light grade, 40mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down carefully unserviceable main switche fuse unit, distribution boards of any type/size from their position including making good to disturbed surfaces of wall etc, complete all as specified & directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
Taking down carefully electric meter of any description by disconnecting electrically and refixing the same in old or new location, complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 47 above but for one 3/5 pin 6 Amps socket outlet on same board.
All as per Srl item No. 47 here-in-before but for one 3/5 pin 6 Amps socket outlet on independent board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 4.0 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15/16 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 6 Amps 240 volt, single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5/6 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 6 & 15/16 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
LED lamp 6500K, 1100lm in white colour of 10 watt, base cap B-22 with poly carbonate diffuser and aluminium heat sink, complete all as specified & directed.
Electronic fan regulator, 2 module, 120watt, (5 stepped type), 240 Volt for 1200/1400mm sweep AC ceiling fan, complete all as specified & directed.
Bell push flush type, one way 6 Amps single pole one way, complete all as specified & directed.
Electronic bell, musical type, AC, 240 volts, single pole, complete all as specified & directed.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
Metallic exhaust fan, 300mm (12") sweep, single phase, 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable including cutting holes in existing brick walls for making opening for fixing of exhaust fan of 300mm sweep including grounting bolts/nuts and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
Factory made epoxy powder coated distribution board vertical type, VTPN, 4 ways with metal double door (IP-43 protection) confirming to IS : 8623, fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar, cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one MCCB 100/160 Amp 4P as incomer and MCBs SP/TP as outgoing, complete all as specified & directed.
MCCB of capacity 100 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 16 KA (minimum) or higher, ATM (Thermal magnetic release), adjustable overload 80-100%, adjustable short circuit 5-10 In, complete all as specified & directed.
Factory made epoxy powder coated distribution board, SPN, 12 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, single pole & neutral, 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
Sub main wiring using uniform coding of wiring with two runs of 6 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 4 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour, complete all as specified & directed. Note:- Two runs of copper conductor 6 sqmm and one run of 4 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Intergral LED security light luminaire 60W LED, 230 volts made up of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, luminaire efficacy >110 Lumens per Watt, Secondary optics for better light distribution, having two nos Potted driver (OEM) (one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95, mounted on & including GI bracket made out of 40mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fittings, complete all as specified & directed.
Supply, hanging and testing of 1200mm sweep, 230 volts, AC ceiling fans, BEE rated energy efficient ceiling fan conforming to IS:374-2019, having 3 blades alongwith copper wound stator (capacitor start) with minimum air delivery 210 cubic metre per minute, power consumption not more than 50 watt, top speed minimum 370 RPM or higher, speed control by 5 step electronic regulator including capacitor, down rod, canopy, making connection with three core flexiable copper cable of 1.50 Sqmm upto ceiling rose & taking down old unserviceable ceiling fan of any type/size from existing location and depositing in MES store, complete all as specified & directed.
Supply, installation and testing of water heater storage type (Geyser), single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, inner tank coating of ferro glass powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners - 04 Nos, hot & cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 2 Nos, non return valve 01 No and including necessary plumbing work, complete with integrated shock safe plug with all protection features as per OEM design and standard, complete all as spcified & directed.
Cutting & screwing of existing water supply line of 15mm bore for alterations or additions (or lengthening screw on pipe to form connector) including testing after completion, complete all as specified & directed. (each cut measured)
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors , complete all as specified and directed.
Bib tap, 15mm bore, fancy type, chromium plated, long body with cup, cast copper alloy with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified & directed.
Stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specifed & directed.
Taking out carefully LT under ground cable of 25 Sqmm 3.5 core of any descriptiion from trenches, complete all as specified & directed.
Factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-I flat size 250x150x40mm, complete all as specified and directed.
Hi Tech Engineers
DARVESH ENGINEERING WORKS
Jiwan Singh
M/S GRD ENGINEERS
THAPA TRADERS
VEE ESS ENGINEERS
M/S SALARIA ASSOCIATES
Pyramid constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .