Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.8 LAdmitted-Finance | -1.55% | ₹4.8 L | L1 | Admitted-Finance |
Tender Value
₹4.9 L
EMD Value
₹9,760
Closing Date
24 Jul 2026, 5:00 pmClosed
EE PWD Elec Dn Ajmer
EE PWD Elec Dn Ajmer
Electrical Emergency Repair and Maintenance work at Govt MCH and Saadat HOSPITAL TONK
2026_CEPWD_575895_5
NIT10 2026-27 EE PWD Elec Dn Ajmer
Open Tender
Electrical Works
Percentage
90 days
Ajmer
Refer NIT Documents
4 documents required · 4 mandatory
₹500
Egras Challan EE PWD Elec Dn Ajmer 7820
₹9,760
Yes
31 Jul 2026
19 Jul 2026
24 Jul 2026
19 Jul 2026
24 Jul 2026
19 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required. | |||||
| 1.1 | 25 mm | 100 | Mtr. | 45 | ₹4,500 |
| 2Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. | |||||
| 2.1 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. | 210 | Mtr. | 142 | ₹29,820 |
| 3Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. | |||||
| 3.1 | Single pole MCB (With B / C curve tripping characteristics) | - | - | - | - |
| 3.2 | 6 A to 32 A rating | 12 | Each | 169 | ₹2,028 |
| 4Triple pole MCB (With B / C curve tripping characteristics) | |||||
| 4.1 | 40 A rating | 6 | Each | 1,358 | ₹8,148 |
| 5Four pole MCB (With B / C curve tripping characteristics) | |||||
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.83 MB
Tendernotice_2.pdf
PDF • 0.37 MB
Tendernotice_3.pdf
PDF • 23.83 MB
Tendernotice_4.pdf
PDF • 4.91 MB
BOQ_1024011.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .