Loading…
Loading…
Tender Value
₹4.9 L
EMD Value
₹9,800
Closing Date
24 Sept 2026, 6:00 pm
Executive Engineer
Executive Engineer, PHED, Division Nagaur
Work of Repairing of Electric Panel or Starter of various UWSS in jurisdiction of PHED Dn. Nagaur
2026_PHCJA_589616_1
NIT No. 42/2026-27 EE Nagaur
Open Tender
Civil Works - Water Works
Percentage
365 days
Executive Engineer, PHED, Division Nagaur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer
₹9,800
Yes
24 Sept 2026
17 Aug 2026
25 Sept 2026
17 Aug 2026
24 Sept 2026
17 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tools) of motor pump set with starter at headworks of water supply scheme / tubewell / openwell including cost of insulation taps etc. | 28 | each | 413 | ₹11,564 |
| - | Labour charges for replacement of defective ampere meter / volt meter with new one on existing panel board in pump house./Tubewell /openwell (new voltmeter/ampere meter will be provided by department | 2 | each | 227 | ₹454 |
| - | Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Depatment) | - | - | - | - |
| - | 5 to 15 HP. | 4 | each | 297 | ₹1,188 |
| - | 16 to 30 HP. | 30 | each | 344 | ₹10,320 |
| - | 31 to 60 HP. | 10 | each | 372 | ₹3,720 |
| - | 61 to 100 HP. | 1 | each | 372 | ₹372 |
| - | 101 to 150 HP. | 1 | each | 391 | ₹391 |
| - | Supply & filling starter oil in oil immersed starters at site. | 100 | Litre | 244 | ₹24,400 |
| - | SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . With Thermal Magnetic release | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.20 MB
BOQ_1047126.xls
BOQ • 0.36 MB
42.pdf
Tender Documents • 3.72 MB
0Corrigendum25to42.pdf
PDF • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].