Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.7 L+₹45,639 (2.50%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹20.5 L+₹2.3 L (12.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹22.5 L+₹4.2 L (23.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
2 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
PROVN OF CONNECTING PASSAGE BLDGS TO COOK HOUSE/ DINING HALL/ LIVING AREA AT JWG AND PROVN OF SEPTIC TANK WITH SOAKAGE PIT NEAR BLDG NO T-13 AT SURANKOTE AND SPECIAL REPAIR TO BLDG NO T-06 AND T-08 AT SURANKOTE UNDER GE 881 EWS
2022_MES_543580_1
GE/PNH-37/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹48,000
Yes
13 Oct 2022
5 Aug 2022
8 Sept 2022
5 Aug 2022
2 Sept 2022
20 Aug 2022
Amount
B&R PORTION:- Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed.
Dismantling of fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
Dismantling framed trusses of span not exc 10 m, complete all as specified and directed.
Dismantling of timber scantling 40sqcm and over in section unframed work,as in fillets, rails, posts, rafters, purlins etc complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Demolition of cement concrete ( un reinforced ) in ground floors and paving n exc. 15 cm. thickness, below or above ground level complete all as specified and directed. .
Dismantling or wall/ceiling board (fibre, pulp, insulation, etc) or insulation board.slabs/ blankets, of any thickness, including cover fillets complete all as specified and directed.
M & L for Walling of random rubble, brought upto course, built in CM 1:6 complete all as specified and directed.
All as per item No 9 above but except stone complete all as specified and directed.
M&L for Brick work with old size sub class ‘B’ bricks, straight or curved on plan exc. 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed.
S&F rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 290(Gde E 165), complete all as specified and directed.
S&F Mild Steel rolled section in purlin, main and cross beam, rafter,posts etc. incl connected cleats, hold fasts etc of grade conforming to Fe 410-W (Gde E-250 quality A) complete all as specified and directed.
S & F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for preparation of new steel & Iron surfaces, width or girth exceeding 10cm & apply two coats of synthetic enamel paint of 1st quality over a coat of red oxide zinc chrome complete all as specified and directed.
S & F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter and similar works fixed with self tapping screws complete all as specified and directed.
M&L for PCC 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in coping, plinth band, bed block PCC blocks for hold fast including rounded or chamfered angle as directed including necessary form work etc., complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in sub base and flooring, etc. complete all as specified and directed.
M&L coloured Non Skid ceramic tiles 7 to 8mm thick (square/ rectangular) are of each tile exc 0.18 Sqm but n.exc. 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with & incl 15mm thick screed bed or bedding layer with CM 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles (300x200mm) x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick back coat layer in cement mortar 1:4, complete all as specified and directed.
S&F 4mm thick E-board(Classic) including fixing of frame work made of special section MS galvanised sheet with zink coating cellular intro painting and consisting of angle cleats of size 25mm wide 1.6mm thick with flag fixing to the ceiling with dash fastner 12.5mm x 40mm long or with 2mm dia GI wire or fixed with bolt in GI channel main 35x25x0.5mm thick and cross runner 25x25x0.5mm for fixing E-board of size 600x600x4mm thick including fixing of E-board with ceiling section and parimeter of channel 25x25x1mm thick, 27mm high flange of 20mm to 30mm long extra, complete all as specified and directed.
M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate, 50mm thick as in plinth protection finished fair & even laid in alternate bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
M & L for 75mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate , as in sub base. complete all as specified and as directed by the Engineer-in-Charge
M&L for chequered cement concrete tiles with grey pigment cement and pigments of size 30cmx30cmx25 mm thick,set, jointed and pointed in neat cement surry in floors including 20 mm thick screed bed in CM 1:6 for laying floor tiles complete all as specified and diected.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work, chajja and suspended work finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 20 mm thick in CM 1:4 on other than fair faces of brick work or stone masonry finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on other than fair faces of brick work or stone masonry or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L for applying two coats of cement base paint on walls including preparation of new plastered or un-plastered surfaces of wall complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of oil emulsion distemper over a coat of 1mm thick wall putty complete all as specified and directed.
Taking down chowkhats or frames with shutters n exc 1.5 Sqm (without taking off shutters from frame) complete all as specified and directed.
Taking down chowkhats or frames with shutters exc 1.5 Sqm but n.exc 4 Sqm (without taking off shutters from frame) complete all as specified and directed.
Taking down shutters and refixing in same opening of area exc 1 sqm but not exc 2 sqm ters n exc 1.5 Sqm after necessary repairing complete all as specified and directed.
S & F pressed steel frame of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges 100mm long , 03 Nos each for double shutters, lock strike plate etc complete all as specified and directed.
S & F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered or rounded, mitred and rebated shash bars, any numbers, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a), supplied & fitted to chowkats complete all as specified and directed.
S & F 35 mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board, medium density, wood particle board with commercial face veneered supplied & fitted to chowkat complete all as specified and directed.
S&F Steel window/ ventilator glazed and gauged (combination) with side hung/ top hung shutters incl box type / projecting type hinges, and steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame complete incl necessary cooler arrangement in window & guard bars all as per sample kept at GE Office complete all as specified and directed.
S & F 100 mm butt hinges, medium weight cold rolled mild steel and fixed, complete all as specified and directed.
S & F 150mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 150 mm long aluminium handles, cast type, anodised complete all as specified and directed.
S & F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S & F 300 mm, mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed.
M&L for Preparation of wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F Sheet glass, ordinary quality, 3mm thick and glazed with oil putty or wooden beads, in square n exc. 0.5 Sq m each pane, complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and directed.
S&F in repair 25mm dia MS powder coated tublar curtain rod, fancy type, complete all as specified and directed.
M&L for cement concrete 1:2:4 type C-1 using 20mm graded aggregate as in surface channel and drain complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc.Rough finished surfaces of concrete also splays between floors and beams, etc. complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per Item No. 49 above but in stirrups, spacers and binders complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified.
M&L for RCC ,1:2:4 type B1, using 20 mm crushed agg.as in beams, cantilevers, bressumers, lintels over 1.5 m span and the like, complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, shafts, wells, cesspits, manholes, pier holes, laying of pipes etc. n exc 10 sq m on plan and getting out in hard/ dense soil complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed.
Removal of excavated soil exc 50 m and not exc 100 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick wall surface or concrete surface finished even and smooth without using extra cement including mixing of water proofing compound @3% by weight of cement (WPC shall be measured and paid separately) including all necessary scaffolding, complete all as specified and directed.
Supply only liquid water proofing admixture complete all as specified and directed.
M&L for TMT bars, 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified.
M&L for precast cement concrete (1:2:4) using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for concrete bed to drain pipes of 150 mm dia incl packing under and haunching against the sides of pipes with concrete, after they are laid in cement concrete 1:3:6 typer C2 (using 40mm graded crushed stone aggregate) and testing including necessary form work, complete all as specified and directed.
M&L for Salt-glazed stoneware drain pipes laid in trenches and jointed on concrete bed, including testing, complete all as specified and directed.
Construction of 10 users LLDPE septic tank designed to carry sewage and sludge, excavation in any type of soil, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) below foundation, vent shaft, connections etc. conventional type all as shown on Drawing No: CE/TD-1202/2003 sheet 1/2 and 2/2 amended upo date complete all as specified and directed by Engineer-in-charge. Note: Drgs are not being uploaded however it can be seen in office during working hours
Construction of soakage well 2.4 mtr dia and 3.00 mtr deep below inlet (depth) from inlet pipe to ground level 45 cm, including excavation and earth work in any type of soil, PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) in foundation, wall in honey combed brick work in CM 1:4, cover slab of M-25 (Design mix), filling with brick bats, earth cushion on brick lining on top and inlet pipe 150mm dia all as shown on drawing No: CE/TD-1202/2003 sheet 1/2 and 2/2 amended upto date complete all as specified and directed by Engineer-in-charge.Note: Drgs are not being uploaded however it can be seen in office during working hours
Surface excavation not exceeding 30cm deep and average 15cm deep and getting out in any type of soil, complete all as specified and directed.
M & L for 100mm thick cement concrete type E-2 1:5:10 using 40mm graded aggregate , as in sub base to tiles complete all as specified and as directed by the Engineer-in-Charge
M&L for chequered cement concrete tiles with grey pigment cement and pigments of size 20cmx20cmx25 mm thick,set, jointed and pointed in neat cement surry in floors including 20 mm thick screed bed in CM 1:6 for laying floor tiles complete all as specified and diected.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following:-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per srl item No 69 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC poly carbonate, insulated body, complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 5 pin, 6 Amp flush type universal), complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin, 6 Amp flush type, complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 3 pin, 6 & 16 Amp flush type universal, complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed.
Supply and fixing inverter LED batten 20 W with square profile and polycarbonate channel, lithium lon battery with charging time 8 hours - 10 hours and backup time upto 4 hours with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make :- Havellas Cat part No- LHEXACP7FN1W020 or equivalent Make as specified in PS.
S & Fin repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED 9 W inverter bulb B22 CDL with holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 4 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN 32 amps, capacity 10 KA, 'C' series complete all as specified and directed.
S&F in repair MCB single pole 6 to 32 amps, capacity 10 KA, 'C' series complete all as specified and directed.
S&F in repair submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable, 1100 volts grade of size 4 Sqmm (nominal area) each and one single core 4 Sqmm cable as earth continuity conductor to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover complete all as specified and as directed. Note : Three runs of 4.00 Sqmm cable and one run of PVC conduit shall be measured as on unit
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
Supply, laying and testing of cable in trenches/ poles XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 2 core 16 sqmm including taking down complete all as specified and directed.
M&L for sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed.Note: 1.Dry fine sand of best available quality shall be used. 2.Punned down thickness shall be made and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
S&F in replacement of GI pipe light grade 40 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps, nuts bolts etc all as specified.
M/S Farooq Ahmed Bhat
M/S BADRI NATH GUPTA
narayan construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .