| 3 | L3₹21.3 L+₹2.1 L (10.8%)Rejected-Finance BHU | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹25.9 L+₹6.7 L (34.7%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹26.9 L+₹7.7 L (40.1%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 Sept 2024, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur-208008
REWIRING OF MD/OTM BLDG AND CONNECTED WORKS AT 7 AFH KANPUR CANTT
2024_MES_669153_1
GE (AF) BR/CHK/T-31 OF 2024-25 8965/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
7 AFH KANPUR CANTT
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹70,000
Yes
21 Nov 2024
31 Aug 2024
7 Oct 2024
31 Aug 2024
30 Sept 2024
16 Sept 2024
Amount
Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose , pendant holder, fitting and fixtures , call bell etc and making good to disturbed surface to wall ,floor etc to match with existing surface either by using same colour distemper or white colour wash all as required and directed by the Engr-in-Charge.
M&L for point wiring PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sq mm , 1100 V drawn in and including PVC casing and capping complete including cast iron/pressed steel terminal box 1.6 mm thick of required size bakelite sheet 3mm thick for mounting switch , socket brass screws and washer including PVC insulated and unsheathed solid copper wire of size 1.5 Sq mm will be used as continuous earth wire for the following :-
One light /fan point controlled by one, one way switch.
One 5/6 Amp socket on the same board with other switch.
One 5/6 Amp socket on independent board.
One bell point controlled by one, one way bell push button.
One 3 pin 15 Amp socket independent but with 2.5 q mm PVC insulated unsheathed copper stranded conductor and earth wire with 2.5 Sqmm
All as per item No. 2 above but concealed wiring drawn in and including non metallic PVC conduit 20mm dia medium grade :-
One light/ fan point controlled by one way switch.
One 3 pin 5 Amp socket on the same board
One 3 pin 5 Amp socket on independent board.
One bell point controlled by one bell push button.
All as per item no 3 but for one 3 pin 15 Amp socket independent but with 2.5 Sq mm PVC insulated unsheathed copper stranded conductor and 2.5 Sq mm size PVC insulated soild copper conductor as earth continuity conductor.
S&F switch piano type 240 V, 5 Amp complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 amps complete all as specified and directed.
S&F switch piano type 240V,15/16 Amps complete all as specified and directed.
S&F socket outlet 5/15 amps complete all as specified and directed.
S&F bell push 240V, 5 Amps complete all as specified and directed.
S&F ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed.
S&F batten holder PVC/Polycarbonate type 2A 250V AC with jumbo skirt including LED lamp 9W complete all as specified and directed.
M&L stepped type electronic fan regulator 240Volt single phase fix on the existing phenolic laminated sheet complete as specified
M&L bell electric , 240 Volt , single pole complete all as specified and directed.
S&F in replacement of sheet metal enclosures for distribution board VTPN 4 way double door type including with one no MCCB 4 pole 100 Amps,16KA fixed type as incomer with 200 Amp rated bus bar complete all as specified and directed.
S&F in replacement of sheet metal enclosure for MCB DB TPN double door, 4 way complete with 200 Amps rated Bus bar complete all as specified and directed.
S&F in replacement of sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified
S&F in replacement of sheet metal enclosures for MCB distribution board SPN 4 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified
S&F in in replacement of MCCB 4 pole, 125 Amps 16KA, 415 Volt complete all as specified and directed.
S&F in in replacement of Isolator 4 pole,100 Amps, 415 Volt complete all as specified and directed.
S&F in replacement of Isolator TPN , 63 Amp , 415 Volt complete all as specified and directed.
S&F in replacement of Isolator SPN , 63 Amp , 240 Volt complete all as specified and directed.
S & F in replacement MCB SP 5-32 Amp 240 V, 'C' Series, multi-breaking capacity of 10 KA with over load and short circuit protection, 1 module complete all as specified and directed.
S & F in replacement of MCB SPN 63 Amp, 230 Volt C curved, multi-breaking capacity not less than 10 KA with over load and short circuit protection, complete all as specified and directed.
M& L for earthing complete with galvanized steel earth plate electrode 60cm x60 cm x6.0 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion including PCC pit in (1:3:6) type C-2 cement concrete .RCC 1:2:4 Mix type B-1 reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip 4 mm protection etc. complete all as specified and directed by Engr-in-Charge
M&L for sub main wiring with 2 runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and including PVC rigid conduit 20 mm dia with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring all as specified. (Note. Three run of cable and one run of PVC conduit shall be measured as one run and type of wiring as per existing surface/concealed all as directed by Engr-in Charge.)
M&L for sub main wiring with 2 runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC rigid conduit 20 mm dia with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 6 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring all as specified. (Note. Three run of cable and one run of PVC conduit shall be measured as one run and type of wiring as per existing surface/concealed all as directed by Engr-in Charge)
M&L for sub main wiring with 3 runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and suitable size of PVC casing capping with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 6 Sqmm as continuous nuetral (Black colour) and one run of earth wire 6 Sqmm (green in colour ) respectively, run through PVC casing N capping and connected to the terminal and common earth dolly all as specified and directed. (Note. Five run of cable and one run of PVC casing capping shall be measured as one run complete all as specified.)
M&L for sub main wiring with three runs of single core 10 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC casing capping with all necessary fittings and accessories and 01xrun of PVC insulated and unsheathed single core cable multi stranded with one run of copper conductor of size 10 Sqmm as continuous neutral(Black colour) and 01 X run of earth wire 6 Sqmm (green in colour ) respectively, run through PVC casing N capping and connected to the terminal and common earth dolly all as specified and directed. (Note. Five run of cable and one run of PVC casing caping shall be measured as one run complete all as specified.)
S&F in replacement of LED batten fitting 1 x 20 Watt, 6000K,4' complete with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly,energy efficient complete with all light fitting connection with suitable flexible wire from ceiling rose to light fitting connection etc complete all as specified and directed by Engineer-in-charge.
S & Fix in replacement of existing LED type surface mounted decorative mirror light fitting 10 Watt complete with all accessories with cover etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as directed.
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connection up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing in replacement of recessed/surface as per site LED ceiling light with wide light window for maximized glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness SMD LEDs 36 watt, 6000K and one nos extra LED driver along the fittings including connecting electric connections complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of unserviceable bulk head fitting of any type with LED bulk fitting with 9 watt LED complete connection with suitable flexible wire connecting to bulk head fitting complete all as specified and directed.
S&F cirrus mini pro 20W LED surface mounting luminaire with dimension of 312mm X 312mm suitable for porch/office all as specified and directed.
S &F in replacement of building security light die cast aluminium IP 66 roadway luminaire with high power LED of 25 watt with toughened glass complete with suitable GI bracket for security light fitting fixing to wall/column & electrical connection to the light fitting providing suitable length and size of twin core round copper conductor cable and testing complete all as specified and directed.
M&L for replacement of unserviceable flood light fitting with energy efficient LED flood light 100 Watt complete with all acessories such as LED dirver and testing complete connection with copper wire 2.5 Sqmm three core from connecting point to the LED fittings all as specified and directed by Engr-in -charge.
S & F in replacement of PVC insulated heavy duty electric unarmoured cable with solid aluminium conductor 1100 Volts grade, cross sectional area 2.5 Sqmm 3 core all as specified and directed by Engr-in -charge.
S & F in replacement of modular switch 1 way 6 Amp, 1 module, 240 V flush type complete all as specified and directed.
S & F in replacement of modular switch 1 way 16 Amp, 1 module, 240 V flush type complete all as specified and directed.
S & F in replacement of modular bell push, flush type, 6 Amp, 1 module, 240 V complete all as specified and directed.
S & F in replacement of modular socket, 6A-2/3 pin combined, 2 module, 240 V complete all as specified and directed
S & F in replacement of modular socket, 6Amp / 16Amp-2/3 pin combined, 2 module, 240 V complete all as specified and directed.
S & F in replacement of modular fan step regulator, 120 W, 2 module, 240 V complete all as specified and directed.
S & F in replacement of modular white cover plate with frame, 3 module, complete all as specified and directed.
S & F in replacement of modular white cover plate with frame, 4 module, complete all as specified and directed.
S & F in replacement of modular white cover plate with frame, 6 module, complete all as specified and directed.
S & F in replacement of modular white cover plate with frame, 8 module, complete all as specified and directed.
S & F in replacement of modular metal flush box, 3 module, complete all as specified and directed.
S & F in replacement of modular metal flush box, 4 module, complete all as specified and directed.
S & F in replacement of modular metal flush box, 6 module, complete all as specified and directed.
S & F in replacement of modular metal flush box, 8 module, complete all as specified and directed.
S&F in replacement of electronic driver for LED 28 LED tube light complete all as specified and directed.
S&F in replacement of electronic driver 2 x 36 Watt, for ceiling light fitting complete all as specified and directed.
S&F in replacement of flexible wire 23/0076 copper conductor from ceiling rose to fitting/fixture complete all as specified and directed.
Taking down carefully storage type water heater (Geysers) 50/35/25 ltr capacity any make by disconnecting electrically and mechanically from all existing lines, opening of bottom and top for inspection complete incl base plate, heating element and copper tank etc, cleaning carefully and reassembling after necessary repair/replacement as specified here-in-after and replacement of old unserviceable nut/bolts and fixing in the same position complete (Note :- replacement of Major spare part shall be measured and paid separately as supply only under item No 56 to 63 & 65)
M&L for brazing/gas welding process of length n.exc 10 cm for clearance of lekages of copper/stainless inner tank for Geysers 25/35/50 Ltrs capacity by all as specified and directed at site the Engr-in-Charge.
Supply only glass wool for insulation of Geysers any capacity and any make complete all as directed by the Engr-in-Charge.
Supply only copper inner copper tank 25 Ltr capacity Geysers factory manufactured as approved complete all as specified and directed.
Supply only copper inner copper tank 35/50 Ltr capacity Geysers factory manufactured as approved complete all as specified and directed.
Supply only stainless steel inner tank 25 Ltr capacity Geysers factory manufactured as approved complete all as specified and directed.
Supply only stainless steel inner tank 35/50 Ltr capacity Geysers factory manufactured as approved complete all as specified and directed.
Supply only heating element 1500 watts push type with gasket ISI marked all as specified and directed.
Supply only heating element 2000 watts push type with gasket ISI marked all as specified and directed.
Supply only thermostatic switch suitable for Gysers of any make/ type with temperature range adjustable type 25 to 80 degree centigrade superior quality 20 Amps 220 Volts AC Supply complete all as directed.
S&F in repair non return valve, cast copper alloyISI marked horizontal/vertical position suitable for any make any type Geysers complete all as specified and directed.
Supply only indicator lamp 220 Volt AC supply rectangular/circular type as per sample superior quality with neon type lamp of red indicator complete all as specified.
S&F in repairs PVC insulated and sheathed copper conductor flexible cable of size 2.5 Sqmm for electrical connection complete all as specified at site by the Engr-in-Charge.
S&F in repairs pressure release valve with inlet coupling ISI marked complete all as specified and directed at site by Engr-in-Charge.
S & F in repairs bottom split cover for terminal box in as per existing shape & size all as specified and directed at site by the Engr-in-Charge.
S&F in repairs indoor assebmly suitable for 25 Ltrs capacity Geysers of any type made out of brass with inlet and outlet and fixing plate complete including gasket,nut bolts etc as required and as directed by Engr-in-Charge.
S&F in repair/replacement of indoor assebmly suitable for 35/50 Ltrs capacity Geysers of any type made out of brass with inlet and outlet and fixing plate complete including gasket,nut bolts etc as required and as directed by Engr-in-Charge.
S& F in replacement PVC connection of 450 mm long & 15 mm dia with brass nut at both end suitable for Geysers complete all as specified and directed
S&F in replacement chromium plated copper pipe connection 450 mm long & 15 mm dia suitable for Geysers complete all as specified and directed
S&F in repairs Bib taps suitable for bore dia of pipe in 15 mm, fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe and fixed complete all as specified and directed
S&F in repairs Stop valves, 15 mm Bore dia of pipe in mm fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe fixed complete all as specified and directed.
S&F in replacement of tubes 15 mm 'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete including taking down u/s pipes all as specified and directed
S & F in replacement Metal clad single pole and a nutral enclosure with a two pin and earth plug and socket with one single pole MCB SP 20 Amp,240V all as directed.
S & F in replacement Metal clad triple pole and a nutral enclosure with a two pin and earth plug and socket with one single pole MCB TP 32 Amp,240V complete.
Material and labour for Routine maintenance of Solar water heater plant (including any leakages in GI pipes/ replacement of air valve steel tank fixed in hot water tank/ replacement of float valve of cold water tank ) of Cap 100/200/300 /500 /1000 ltrs installed at single/ double/ triple story bldgs for preventing minor leakage using gasket of nitryl rubber of suitable thickness and size , cleaning of flat plate glass collector, cleaning / drain of water from hot and cold water tank and make up tank clean after disconnecting inlet and out let connections incl replacement of rusted nut bolts and washer of appropriate cap,rubber hose pipes and refixing the same at retrieved position after cleaning for proper functioning of the system to maintain proper water temperature, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Flat plate collector up to and including of size 2033 mm x 1033mm x 100 mm ISI marked and as per site requirement, assembly suitable for solar water system existing size and capacity with copper tube black coat/radiation reflector film, aluminum toughed glass, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of HDPE rotational moulded polyethylene cylindrical vertical water storage tanks 500 Ltr cap (triple layered with closed top), conforming to specification of IS:12701-1996 with amendment No 1 and 2 (covered by fig 1) hoisted and fixed in position, including out let and inlet connection including dismantling/taking down of existing unserviceable water storage tanks of any description and capacity complete complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of heating element 2000 watts push type with gasket ISI marked for solar water heater as per sample all as specified and directed.
S&F in replacement of thermostatic switch suitable for solar water heater of any make/ type with temperature range adjustable type 25 to 80 degree centigrade superior quality 20 Amps 220 Volts AC Supply complete all as directed.
S&F in replacement of hot water pipe of 15 mm dia with glass wool and aluminium cladding complete all as specified and directed.
S&F in replacement of hot water pipe of 20 mm dia with glass wool and aluminium cladding complete all as specified and directed.
M/L in replacement of sub main wiring with PVC insulated unsheathed copper conductor cable of 2x2.5 sq mm + 1x2.5 sq mm earth wire drawn in and including PVC conduit 20mm dia for solar water heater all as directed by Engr-in- Charge
AARADHIRAJ ASSOCIATES (BID ID -3106049)
Lalta Prasad vijay kumar Forwarding Agency (BID ID -3108176)
santosh electronics (BID ID -3107273)
SAKSHAM SUPPLIERS BUILDERS (BID ID -3109142)
M/S Balaji Infratech (BID ID -3102735)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .