| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.0 Cr+₹3.3 L (3.38%)Rejected-Finance H NO 2715 SECTOR 9 11 HISAR 125001 HARYANA | HISAR | HARYANA | 125001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹1.0 Cr+₹6.8 L (6.99%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹1.1 Cr+₹10.8 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹1.1 Cr+₹15.6 L (16.0%)Rejected-Finance A 102 GOLDEN SAND APARTMENTS GAZIPUR DHAKOLI ZIRAKPUR PB 160104 | ZIRAKPUR | S A S NAGAR | PUNJAB | 160104 | L5 | Rejected-Finance Being L5 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
11 Jun 2024, 6:00 pmClosed
Commander Works Engineer Hisar
Headquarters Commander Works Engineer Military Engineer Services Hisar, Military Station Hisar Hisar (Haryana)-125006
SPECIAL REPAIR AND PROVISION OF ROADS AT VARIOUS LOCATIONS AT HISAR MIL STN UNDER GE HISAR
2024_MES_652796_1
CA NO CWE/HSR/13 OF 2024-25
Open Tender
Civil Works - Roads
Item Rate
180 days
Hisar
As per Notice Inviting Tender (NIT)
7 documents required · 7 mandatory
₹1,000
Yes
GE Hisar
₹2.2 L
Yes
22 Jul 2024
7 May 2024
13 Jun 2024
7 May 2024
11 Jun 2024
28 May 2024
7 May 2024 - 4 Jun 2024
Amount
Repair to potholes any depth, not exceeding 1 sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc., cutting around edges to at least 25 mm in depth, making good by applying tack coat with cationic bitumen emulsion RS-1 grade at the rate of 5 kg per 10 sqm, putting in semi dense bituminous concrete consolidated/ compacted thickness using hot mix plant and mechanical paver using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 5% by weight of total mix & hydraulic lime filler, rolled and compacted to required camber and gradient complete all as specified and as directed. Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.
Preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and as directed.
M & L for applying tack coat on existing bituminous, cement concrete or primed granular surface to ensure a bond between the surface being paved and the overlaying course with cationic bitumen emulsion RS-1 grade at the rate of 5 kg per 10 sqm of surface complete all as specified and as directed.
M & L for semi dense bituminous concrete 30 mm (compacted thickness) using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 5% by weight of total mix & hydraulic lime filler, rolled and compacted to required camber and gradient complete all as specified and as directed. Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.
Supply and fix in repairs Glow studs (cat's eye) of size 80 to 100 mm X 80 to 100 mm X 15 to 20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The cat’s eye shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35⁰ ± 5⁰ to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 Part 4: 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete all as specified and as directed.
S & F in repairs solar road studs of size not less than 125 mm X 125 mm X 25 mm made of weather resistance aluminium alloy and poly carbonate material electronically welded micro- prismatic lens with abrasion resistant coating as approved by the Engineer in charge. The cats eye shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35⁰ ± 5⁰ to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM E: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge. The solar panel shall be high efficiency mono crystalline 2.5 V/60 m A and the battery shall be one Ni-mh type (1.2 V/1200 m Ah) high temp for backup of 36 hours full charging. The flash frequency shall be 60 ± 5 times per minute.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed.
M & L for construction of granular sub-base (GSB) as filter-cum-drainage layer, 150 mm thick (compacted thickness) by providing grading V material as per Table 400-1 of the MORTH Specifications for Road and Bridge (Fifth revision published by IRC, 2013 Edition) mixing in a mechanical mix plant at optimum moisture content, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 of the MORTH Specifications for Road and Bridge (Fifth revision published by IRC, 2013 Edition) complete all as specified and as directed.
M & L for 15 cm thick (compacted thickness) WBM in two layers of 7.5 cm each with coarse aggregates of granite, trap or basalt of grading 2 (63 to 45 mm size) or of grading 3 (53 to 22.4 mm size), spread, rolled and compacted to required gradient and camber with three wheel-power roller of 80 to 100 kN capacity or an equivalent vibratory roller complete all as specified and as directed.
Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and as directed.
M & L for applying primer on the surface of non-bituminous granular base course preparatory to the superimposition of bituminous treatment coat with cationic bitumen emulsion SS-1 grade at the rate of 10 kg per 10 Sqm of surface complete all as specified and as directed.
M & L for applying tack coat on existing bituminous, cement concrete or primed granular surface to ensure a bond between the surface being paved and the overlaying course with cationic bitumen emulsion RS-1 grade at the rate of 3 kg per 10 sqm of surface complete all as specified and as directed.
M & L for semi dense bituminous concrete 40 mm (compacted thickness) using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 4.5% by weight of total mix & hydraulic lime filler, rolled and compacted to required camber and gradient complete all as specified and as directed. Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.
Providing and laying at or near ground level factory made kerb stone of any size, top bullnosed shape, made of M-25 (Design Mix) grade cement concrete, in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed.
Excavating over areas not exceeding 1.5 m deep and getting out in soft/ disintegrated rock complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.
Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed.
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 conforming to IS 15658: 2021 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness, size and shape, made by table vibratory method using polyurethane mould, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand having gradation as per IRC SP 63: 2018 and 2 to 4 mm wide joints filled with fine sand having gradation as per IRC SP 63: 2018, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
Preparation of newly or previously untreated plaster surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer of the same manufacturer complete all as specified and as directed.
Sh. Raj Kumar Malik Contractor
malik constructions
M/S Sulakh Brothers
AP BUILDERS
PAWAN KUMAR
BAL SINGH AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .