Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.2 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹16.8 L+₹94,575.40 (5.96%)Rejected-Finance H NO 177 GOVINDPURA SATWARI JAMMU CANTT 180003 J K | JAMMU | JAMMU AND KASHMIR | 180003 | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹17.7 L+₹1.8 L (11.3%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹21.0 L+₹5.2 L (32.5%)Rejected-Finance 14 ILTIFATGANJ AMBEDKAR NAGAR UTTAR PRADESH 224145 UDYAM UP 04 0036158 | AMBEDKAR NAGAR | UTTAR PRADESH | 224145 | L-4 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
23 Jan 2023, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
AUGMENTATION OF SEWAGE SYSTEM INCLUDING CLEANING AND REPAIR OF MANHOLES, SEPTIC TANKS ETC IN ZONE A AREA AT MIRAN SAHIB UNDER GE JAMMU
2022_MES_571694_1
GEJC-64/2022-23
Open Tender
Civil Works
Item Rate
240 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹40,000
Yes
4 Feb 2023
28 Dec 2022
25 Jan 2023
28 Dec 2022
23 Jan 2023
10 Jan 2023
Amount
Cleaning and clearing the blockage of sewage lines of any dia, type and any depth removing any type of blockage by roding from main holes or by flushing water with pressure pump complete all as specified and as directed.
Taking out of solid / semi solid sludge from existing main holes of any size and any depth and burying the entire sludge / sludge water into excavated pit of adequate size including excavation and covering with earth or disposing off into covered vehicles outside the peripherry of defence land to a distance exceeding 1 KM including taking off RCC / iron main holes covers and refixing the same after clearing complete all as specified and as directed.
Cleaning of blockage of EWC / IWC / Urinal / Bathroom / Kitchen and gully trap and removing of sludge / spoil / waste to distance exceeding 100 metre and testing of water closet block for proper working after cleaning complete all as specified and as directed.
Notes: - For Ser Item No 1.00 to 3.00: - (i) For the purpose of payment, cleaning of sewage lines and upto including 1st manhole shall be measured as one job. (ii) The contractor will employ two safaiwalas alongwith necessary T&P on all working days for the period of contract for attending the sewage related complaints for buildings where machine cannot be reached. The complaints will be collected by the contractor or his accredited representative on all working days from B/R complaint cell. Complaints will be got signed by the authorised users representatives and will be returned to B/R complaint cell after completion of the complaint. No complaint shall be kept pending or unattended for more than 24 hours.
Cleaning of septic tanks upto and including 25 users capacity inclusive of removing sludge and sludge water by vehicle mount sewage cleaning machine and jetting and the sluggly sludge water is to be disposed off to a distance of 2 Kms outside the peripherry of defence land including taking off and refixing manholes covers etc complete all as specified and as directed.
Cleaning of septic tanks upto and including 25 users to 50 users capacity inclusive of removing sludge and sludge water by vehicle mount sewage cleaning machine and jetting and the sluggly sludge water is to be disposed off to a distance of 2 Kms outside the peripherry of defence land including taking off and refixing manholes covers etc complete all as specified and as directed.
Cleaning of septic tanks upto and including 50 users to 100 users capacity inclusive of removing sludge and sludge water by vehicle mount sewage cleaning machine and jetting and the sluggly sludge water is to be disposed off to a distance of 2 Kms outside the peripherry of defence land including taking off and refixing manholes covers etc complete all as specified and as directed.
Cleaning of septic tanks upto and including 100 users to 200 users capacity inclusive of removing sludge and sludge water by vehicle mount sewage cleaning machine and jetting and the sluggly sludge water is to be disposed off to a distance of 2 Kms outside the peripherry of defence land including taking off and refixing manholes covers etc complete all as specified and as directed.
Cleaning of septic tanks upto and including 200 users to 250 users capacity inclusive of removing sludge and sludge water by vehicle mount sewage cleaning machine and jetting and the sluggly sludge water is to be disposed off to a distance of 2 Kms outside the peripherry of defence land including taking off and refixing manholes covers etc complete all as specified and as directed.
Notes: - For Ser Item No 5.00 to 9.00: - (i) The sewage line is required to be cleaned by using water jetting machine as directed by Engineer-in-Charge. The unit rate quoted by the contractor shall deem to be included of this provision and no extra claim on this account shall be entertained by the department. Jetting machine will be compulsory minimum three times a week otherwise one day recovery of Rs. 10,000/- will be deducted from the payment due to the Contractor. (ii) Contractor during the mechanized operation shall be equipped with gas monitor, nylon rope ladder, torch light and compressor blower etc along with the sewage cleaning truck mounted suction / jetting machine. (iii) Manual cleaning operation / Scavenging is prohibited. (iv) The unit rate quoted by the contractor shall interalia deemed into the cost of providing skilled driver and operator and supervising engineer including provn of water for jetting and removal of sludge / silt / liquid / mud and sand (in foul position) etc complete all as specified. (v) Contractor shall engage the above mentioned T&P and intimate to Engr-in-Charge in writing with machine No / Vehicle No etc for their record and prior approval. (vi) The T&P as and when brought by the contractor based on site requirement, the concerned site executive shall take a photograph of machine along with the supervising staff i.e. JE's and contractor's representatives etc and same shall be kept in record with date. (vii) Pucca bound register shall be maintained showing the machine no / vehicle no and their deployment at site mentioning time and date duly signed by concerned JE, Engr-in-Charge and contractor and the same register shall be produced while claiming the payment by the contractor.
Excavation in trenches not exceeding 1.5 m wide, not exceeding 1.5m in depth, for foundation, etc, or for shafts, wells cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed.
Description all as per Ser Item No 11.00 here-in-before but depth exceeding 1.5 m and not exceeding 3 metre complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removal of surplus excavated soil to a distance exceeding 250 m and not exceeding 500m and deposited where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
Demolition / breaking of drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar and taking out off trenches and removing the debris from the site of 150mm / 200 mm dia pipe including demolition of cement concrete bed / haunching etc complete all as specified and as directed.
Material and labour for concrete bed to 200 mm bore pipe (1:4:8) in type D-2 (using 40mm graded crushed stone aggregate) including haunching against the sides of pipe complete all as specified and directed.
Material and labour for concrete bed to 150 mm bore pipe (1:4:8) in type D-2 (using 40mm graded crushed stone aggregate) inclduding haunching against the sides of pipe complete all as specified and directed.
Supply and fixing and laying 200 mm thick reinforced concrete pipes class NP-2 laid and jointed complete with collers as in trenches complete all as specified and directed.
Supply and fixing and laying 150 mm thick reinforced concrete pipes class NP-2 laid and jointed complete with collers as in trenches complete all as specified and directed.
Material and labour 150mm dia salt glazed stoneware drain pipes laid in trenches in concrete padding, jointed in cement mortar (1:1) complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, drains etc but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and as directed.
Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Description all as per Ser Item no 22.00 here-in-before but except bricks complete all as specified and as directed.
Material and labour for cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping and benching of manholes complete all as specified and directed.
Material and labour for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Material and labour for providing precast cement concrete in cover slab (for manhole) (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) set in cement mortar (1:4) complete all as specified and directed.
Material and labour mild steel TMT bars 10 mm dia and over cut to length, bend to shape etc complete binding with and including mild steel annealed wire not less than 0.09 mm dia conforming TMT bars complete all as specified and directed.
Description all as per Ser Item No 28.00 here-in-before but mild steel round bars 10mm dia and over as in manholes cover handles, steps, clamps etc complete all as specified and as directed.
Material and labour for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished and reforming benching as required of 150mm / 200mm dia pipe complete all as specified and as directed.
Taking up or down PVC pipes (including all fittings), with spigot and socket ends and lead joints including burning out joints and removing lead of 100 / 75mm dia pipe complete all as specified and as directed.
Supply and fixing PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls with brackets etc of 110mm dia complete all as specified and as directed.
Supply and fixing PVC (SWR) pipes single socketed in any length with rubber ring joints using solvent adhesives fixed to walls with brackets etc of 75mm dia complete all as specified and as directed.
Supply and fixing stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of any bore pipe complete all as specified and as directed.
Supply and fixing 110 mm PVC (SWR) junction single (T) equal / unequal complete all as specified and as directed.
Supply and fixing PVC (SWR) bends / shoes any radius of 75 mm dia complete all as specified and as directed.
Supply and fixing PVC (SWR) bends any radius provided with access door of 110mm dia complete all as specified and as directed.
Supply and fixing PVC (SWR) bends any radius provided with access door of 75mm dia complete all as specified and as directed.
Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each but with shutters (without taking off shutters from the frame) complete all as specified and as directed.
Supply and fixing solid PVC door frame of size 50mm X 47mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube supplying and fixing in opening as per specification complete all as specified and as directed.
Supply and laying factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain cover PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded / sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at sie as per specification clause No 8 B.1 to 8 B.10 and drawing on Page No 174 of MES SSR-2020 Part-II complete all as specified and as directed.
Supply and fixing in repair box type steel Ventilator (factory made) outer frame made out of ERW tube 'P' section 65 X 45 X 25 mm and shutter of ERW tube 'P' section 50mm X 35mm X 20mm openable (double shutter) with glazed shutter on external side and gauzed shutter on internal side including steel pintel hinges steel handle 100 mm long mild steel tower bolt 02 no's on each shutter stopper of 'Z' section and its locking arrangement and mild steel hook and eyes suitable for fixing cooler / AC window complete all as specified and shown on drawings No CEPZTD-324/07 Sh 1/3 to 3/3. Notes: - The quoted rates shall also include: - (i) One shop coat of zinc chromate primer on all exposed surface and one coat of tar on the ends of steel surface in contact with bricks / concrete surface. (ii) 4 no's MS steel lugs made of 20 X 5 mm Iron flat 200 mm long. (iii) 10 mm Sq Bar grill / guard bar design as per drawing. (iv) PCC block for embedding lugs. (v) Two coats of synthetic enamel paint. (vi) Galvanized mild steel wire clothes power woven 0.46mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed.
Supply and fixing 100 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed.
Supply and fixing Aluminum anodized, barrel towers bolt of extruded section and fixed 150 mm size complete all as specified and as directed.
Supply and fixing Aluminum anodized extruded section, 150mm long handles fixed to door complete all as specified and as directed.
Supply and fixing in repair water closet white vitreous china ware Orissa pattern of size 580 x 440mm with integral foot rest 'P' or 'S' trap front or back intlet including provision of PCC (1:2:4) type B-1 and provision of cement concrete bedding and making good the dismantled surface and connection flush pipe (rate also including for taking off unhygenic old water closet) 15mm dia PVC connection 450mm long complete all as specified and as directed.
Supply and fixing in repair Vitreous china wash down water closet pan pedestal pattern white including fixing bolts, white / coloured plastic seat cover, chromium plated brass jet nozzle with 600 long PVC pipe, 15mm dia PVC connection 450mm long, making good existing area with tiles complete all as specified and as directed.
Supply and fixing in repair PVC valve less, syphonic action type flushing cistern, low level with inlet, ball valve float and handle including brackets of capacity 10 litres including PVC flush pipe complete all as specified and as directed.
Supply and fixing in repair syphonic action type flushing kit for one piece EWC / two piece EWC for any type make of EWC including 15mm dia PVC connection as per site requirement, i.e. 300mm / 450mm / 600mm complete all as specified and directed.
Material and labour for painting to steel and iron surfaces of any description over 10 cm in width or girth not otherwise described with two coats of syntehtic enamel paint including new or previously untreated surface complete all as specified and as directed.
Supply and fixing sheet 3 mm thick glass ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
M/S A TO Z ENGINEERS
PAKAYA BUILDERS AND DEVELOPERS PVT LTD
M/S R S CONSTRUCTION CO
Bidder Name
ASHFAQ AHMED MANHAS
PAKAYA BUILDERS AND DEVELOPERS PVT LTD
M/S R S CONSTRUCTION CO
M/S A TO Z ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .