Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.7 L+₹2.0 L (30.8%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.8 L+₹2.1 L (32.3%)Rejected-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L3 | Rejected-AOC L3 | |
| 4 | L4₹8.9 L+₹2.2 L (33.6%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L4 | Rejected-AOC L4 | |
| 5 | L5₹9.2 L+₹2.6 L (38.5%)Rejected-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
Closing Date
5 Jun 2021, 6:00 pmClosed
AGE I TALBEHAT
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REPAIR TO ROOF TREATMENT OF CERTAIN BLDGS IN ZONE-11 AND 14 AT TALBEHAT MIL STN
2021_MES_436530_2
AGE(I)/TBT/TOK-10/2021-22
Open Tender
Civil Works
Item Rate
180 days
MILITARY STATION TALBEHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I TALBEHAT
Exempted
16 Jun 2021
17 May 2021
8 Jun 2021
17 May 2021
5 Jun 2021
22 May 2021
Amount
Complete removal of existing roof treatment incl preparation of old roof surface for roof treatment complete all as specified and directed by Engr-in-charge Note: All debris obtained from taking down shall be removed 1.5 km to 2 km complete all as specified and as directed
M & L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed
Demolition cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. Note: All debris obtained from demolition shall be removed 1.5km to 2km complete all as specified and as directed.
M & L for PCC 1:2:4 (B-0) using 12.5mm graded stone aggregate using WPC @3% by weight of cement as in roof top finished the surfaces even and smooth without using extra cement for laying roof treatment complete all as specified and as directed Note;- Water proofing compound shall be measured and paid separately
M&L of water proofing treatment to non accessible roof slab with APP based modified polymeric membrane centre core 100mm micron HMHDPE outer film 20 micron each having thickness 3mm, weight not less than 3Kg/Sqm as per manufacturers instruction with torch application complete all as specified and directed by Engineer-in-Charge with following course of description below: (a) First coat apply bituminous primer confirming to IS-3384of 1965 @ 0.4Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated .(b) Second course of laying of APP based modified polymeric with 100mm overlap in longitudinal direction 150mm in transverse direction sealed and bounded to the surface by torch application method. All joints and changes in all direction should be covered with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane (c) Third course of apply a coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrane Note:- (i)Work of water proofing treatment shall be carried out by the authorised applicator of the manufacturer. (ii) The quoted rates is deemed to include for the cost of scaffolding, T&P etc required for execution of the work.
M&L of water proofing treatment to accessible roof slab with APP based modified polymeric membrane centre core 100mm micron HMHDPE outer film 20 micron each having thickness 3mm, weight not less than 3Kg/Sqm as per manufacturers instruction with torch application complete all as specified and directed by Engineer-in-Charge with following course of description below: (a) First coat apply bituminous primer confirming to IS-3384of 1965 @ 0.4Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated (b) Second course of laying of APP based modified polymeric with 100mm overlap in longitudinal direction 150mm in transverse direction and edges to be taken up to vertical wall of 20cm height inserted in to the vertical wall concealed the joint with bitumen sealant. All joints and changes in all direction should be covered with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane Note:- (i)Work of water proofing treatment shall be carried out by the authorised applicator of the manufacturer.
M&L for water proofing treatment including preparation of surface as required for roof treatment , balcony, terrace etc consisting of following sequences of operation on RCC roof slab for non accessible roof surface M&L for providing and laying of fibre reinforcement elastomeric liquid water proofing membrane with resilient acrylic polymer having sun reflective index (SRI) of 105 manufactured by Asian Paints Ltd or equivalent as approved by AGE(I) on top of concrete roof with consumption @ 10.76 Litre/10Sqm for three coats. One coat of self priming of elastomeric water proofing liquid (dilution with water in the ratio of 3 part of product and one part of water and two coat of undiluted elastomeric water proofing liquid (dry film thickness of complete treatment not less than 500 microns). The operation shall be carried out after scrapping and properly cleaned loosed particles with wire brushes, filled the crack upto 3mm with fibre glass reinforced crack filling compound 10, complete all as specified and as directed by Engr-in-Charge Note: The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer .
M&L for cement concrete tiles 250mmX250mmX25mm / 300mmX300mmX25mm thick laid over 15mm cement screed bed in CM1:4 set and jointed with grey cement and no pigment and pointed in near cement slurry as in accessible roof surfaces
Supply only integral water proofing compound
Demolition of brick work or stone / boulder masonry , built in cement mortar incl all quoins , pillars etc.
M & L brick work with fly ash bricks straight or curved on plan exec 6 M mean radius with old size bricks in CM (1:6).
Taking down cement plaster on brick or stone walls, etc incl racking out joints , hacking for key , scrubbing down with water etc. Note: All debris obtained from taking shall be removed 1.5km to 2km complete all as specified and as directed.
M&L for plastering 15mm thick in CM 1:4 with WPC @3% by weight of cement on roof/parapet wall finished even and smooth without using extra cement complete all as specified and as directed. Note;- Water proofing compound shall be measured and paid separately
Dismantling water tanks of capacity exc 250Ltr and n.exc 500Ltr and complete all as specified and as directed
S&F rotational moulded polyethylene water tank of 500Ltrs capacity (Cylindrical vertical with closed top) noticed and portion all as specified SSR Part-I complete all as specified and as directed by Engr-in-Charge
S&F 20mm ball value high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe all as specified and as directed
Taking up or down 15 mm dia steel tubing and connection including removal complete and all as specified and directed
Taking up or down 20 mm dia steel tubing and connection including removal complete and all as specified and directed
S&F 15mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed.
S&F 20mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed.
Disconnecting existing water tanks exc 250ltr and n.exc 500ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately
M&L for Cleaning and removing all scale and dirt, etc, from water tanks exc 250ltr and n.exc 500ltr and from mouths of circulating pipes, etc
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., and removal complete and all as specified and directed
S & F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls.
S & F for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls.
S & F for 110 mm bore PVC (SWR) bends of any radius including door system complete all as specified and as directed..
S & F for 75 mm bore PVC (SWR) bends of any radius including door system complete all as specified and as directed..
M/S R.S.BUNDELA & SONS
M/S SHIVA TRADERS
HARNAM SINGH ANIL SINGH
M/S Kharya Associates
M/s JS Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .