Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.7 LAccepted-Finance U 57 OPP AGGARWAL NURSING HOME RAJU GAS AGENCY OFFICE VIJAY NAGAR NARELA DELHI DELHI 110040 | NORTH | DELHI | 110040 | 1 | Accepted-Finance 1 | |
| 2 | 2₹20.3 L+₹64,523.88 (3.28%)Rejected-Finance 256 MUNDHELA KHURD NEW DELHI 110073 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110073 | 2 | Rejected-Finance 2 | |
| 3 | 3₹21.0 L+₹1.3 L (6.48%)Rejected-Finance 218 TANGE WALI GALI KACHI CHAWNI JAMMU JAMMU AND KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | 3 | Rejected-Finance 3 | |
| 4 | 4₹24.1 L+₹4.4 L (22.3%)Rejected-Finance | 4 | Rejected-Finance 4 | |
| 5 | 5₹25.3 L+₹5.6 L (28.4%)Rejected-Finance H 50 C SHAKARPUR DELHI 110092 | SHAHDARA | DELHI | 110092 | 5 | Rejected-Finance 5 |
Tender Value
₹30.2 L
EMD Value
₹60,350
Closing Date
20 Nov 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE/NORTH WEST
EEE/NORTH WEST
Provision of street Lighting arrangement in AC-09 (kirari) under North West Zone erstwhile Rohini Zone.
2026_MCD_297688_1
EEE-III/RZ/TC/2026-27/28.1
Open Tender
Electrical Works
Percentage
180 days
EEE/NORTH WEST
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹60,350
20 Nov 2026
13 Nov 2026
20 Nov 2026
13 Nov 2026
20 Nov 2026
13 Nov 2026
120 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm | 2,836 | Metre | 36 | ₹1,02,096 |
| 2.001 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sqmm | 2,278 | Metre | 104 | ₹2,36,912 |
| 3.001 | Supplying and erection of galvanised ‘D’ iron clamps complete
with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and
washers, coach screws etc. as required. | 24 | Nos. | 316 | ₹7,584 |
| 4.001 | LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).-72 Watt | 650 | Nos. | 2,128 | ₹13,83,200 |
| 5.001 | Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 25mm X 6 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required | 650 | Nos. | 982 | ₹6,38,300 |
| 6.001 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:- a) 2C x 6 sqmm | 2,836 | Meter | 95 | ₹2,69,420 |
| 7.001 | S.I.T.C of Hot Press moulded SMC panel/Canopy Box of size(OD) 920 mm x 460 mm x 260 mm & (ID) 900 mm x 450 mm x250 mm , anti – corrosive, dust proof, rust proof, shock proof , Self-extinguishing property , resistant to heat , Vermin proof, Ultra Violet stabilized, Pilfer resistant, Suitable for mounting 1 no. 3 phase Starter, 1 no. 63 Amp 4 pole isolator and 1 no. 3 phase Energy meter, Socket for outgoing connection with pilferage proof SMC door duly welded with S/S handle having danger logo on its outer surface and with 1 no Hot Dip galvanized iron stand for a base of size 40 mm x 40 mm x 5 mm and height of the stand is 600 mm including 300 mm height below the ground with side strip of size 25 x 5 mm. | 11 | each | 12,922 | ₹1,42,142 |
| 8.001 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.(a) Double pole | 11 | Each | 696 | ₹7,656 |
| 9.001 | Supplying and fixing following rating, double pole, 240 V, solator in the existing MCB DB complete with connections,testing and commissioning etc. as required. 63 A | 22 | Each | 569 | ₹12,518 |
| 10.001 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.3 output (1output per phase) and suitable for three phase supply | 11 | Nos. | 11,161 | ₹1,22,771 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
Tender_Condition1.pdf
Tender Documents • 0.18 MB
MCD_GCC_Latest_Circulars.pdf
Tender Documents • 13.92 MB
BOQ_346818.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .