Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 2277 RAJA PARK RANI BAGH RANI BAGH NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Accepted-Technical fullfill quotation requirement |
| 2 | Accepted-Technical 38A 2 JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | Accepted-Technical fullfill quotation requirement |
| 3 | Accepted-Technical 101 1 10 68 4 PLOT NO 52 SRINIVASA NILAYAM CHIKOTI GARDENS BEGUMPET HYDERABAD TELANGANA 500016 | MEDCHAL MALKAJGIRI | TELANGANA | 500016 | Accepted-Technical fullfill quotation requirement |
| 4 | Accepted-Technical AT E 23 KARAMPURA NEW DELHI PIN 110015 | Accepted-Technical fullfill quotation requirement |
| 5 | Accepted-Technical A 4014 BHANDUP INDUSTRIAL ESTATE L B S MARG BHANDUP WEST MUMBAI | MUMBAI | MUMBAI | MAHARASHTRA | Accepted-Technical fullfill quotation requirement |
Tender Value
Refer Docs
Closing Date
12 Dec 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DSO and Secretary
District Sports Complex, Sangli
E quotation for estimate purpose
2025_DSYSP_1251410_1
DSCC/Equotation/track/202526
Open Tender
Civil Works
Item Wise
District Sports Complex Sangli
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
16 Dec 2025
5 Dec 2025
15 Dec 2025
5 Dec 2025
12 Dec 2025
5 Dec 2025
Supply and installation of Cast in situ IAAF approved Synthetic Athletics SANDWICH track system with a minimum thickness of 14mm for Normal Stress Areas & 20-25mm for High Stress Areas,. The system should consist of application of 3 layer in situ installed self levelling layers broadcasted with rubber granules. This systems offers athletes maximum comfort and highest available performance and globally used in competitions. The particularity of this system lies in the application of a primer on the asphalt substructure, bottom and middle layers of liquid Binder mixed with SBR granules, top layer of Liquid PU mixed as per manufacturer instructions and EPDM broadcasting on top. The system consumption ratios consists of application of primer layer of 0.25 kg/sqm, base layer of SBR granules (1-4mm) with 3kg/sqm mixed with binder 2.2 kg/sqm, middle layer of SBR granules (1-4mm) with 2kg/sqm mixed with binder 2.2 kg/sqm, top wear coat of liquid PU binder with consumption of 2.80 kg/sqm and EPDM granules of 1-4mm broadcasted in the range of 2.6 kg/sqm net. The system should be approved as IAAF class 1 with a certificate and line marking should be done as per the IAAF norms. The contractor shall test all material from IAAF accredited labortory to obtain class 1 IAAF certificate and all the charges borne by the contractor. all test results required according to DIN V 18035-6:2004-10. IAAF Approved Synthetic Track -Manufacturer Country Of Origin :- USA / EU/ Europe/ Australia.
Providing & Fixing Aluminium track Curbing with fixing arrangement having size 60 X 50 mm box type having weight 1 kg/ Rmt. Top held in place by 10mm tall ribed feet raised 10mm of the track surface for rapid drainage each section of curbing shall be milled to allow easy drop in or removed corresponding section annodized finished and IAAF certified.
Supplying and filling of Silica Sand in sand pit of approved quality including cost and conveyance of all materials and labour charges to the site to fill the sand in pits. Spec. As directed by Engineer charge. As per attached reference Image
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers perforated on Strom water /surface drains of field of play of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Supplying, deliver , stacking on site medium Fine sand with Sandy loam suitable for Natural turf rootzone as per specification including Transportation, loading, unloading, royalty etc. Complete as directed by engineer in charge. (NOTE: The Sand for Turf construction is as follow Coarse sand: 60% of the material must fall in the 0.5 to 1mm range. Medium Sand: 0.5 to 0.25mm & Fine Sand 0.25 to 0.15 mm not more than 20%. Very find Sand 0.15 to 0.05 mm Maximum permissable is 10% . Silt and Clay <0.05mm Not more than 5%.) As directed by engineer in charge & Turf consultant.
Finishing Levels: Once the root zone is spread over the sub base rectify undualtions if any, level and compact with water, to keep the root zone moist uniformaly. Spec.:- As directed by Engineer in Charge.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
RFP_Rate_list.pdf
Tender Documents • 0.09 MB
BOQ_2157694.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .