Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹60.4 L+₹2.4 L (4.14%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹64.0 L+₹6.0 L (10.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹82.8 L+₹24.7 L (42.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹62 L
EMD Value
₹1.2 L
Closing Date
6 Jul 2020, 6:00 pmClosed
CWE NO 2
CWE NO 2 DELHI CANTT
SPL REPAIR TO EYE OT AT BASE HOSPITAL UNDER GE (E/M) BASE HOSP, DELHI CANTT-10
2019_MES_302311_4
CWE/BH-29/2019-20
Open Tender
Civil Works
Item Rate
120 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (E/M) BASE HOSPITAL
₹1.2 L
Yes
20 Jul 2020
6 Jun 2020
8 Jul 2020
6 Jun 2020
6 Jul 2020
22 Jun 2020
Amount
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and paving not exc 15cm thickness( below or above ground level) and complete all as specified and directed.
M&L for Cement concrete in foundation filling and mass concrete in type C2 (1:4:8) using 40mm graded stone aggregate complete all as specified and directed.
M&L for 75 mm thick PCC type C-2, 1:3:6 (40 mm graded agg) as in path/plinth protection and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over cut to length bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to (TMT) complete all as specified and directed.
M&L for Mild steel TMT bars 8mm dia and over up to 10mm as in stirrups, spacers and binders and binding with mild steel wire (annealed) not less then 0.90mm dia complete all as specified and directed.
M&L for Reinforced cement concrete nominal mix 1:1.5:3 Type A1 using 20mm graded stone aggregate as in foundation / footing,plinth,lintle,roof beams,bases for column etc complete all as specified and directed. Note : Reinforcement and form work shall be measured and paid separately.
M&L for Reinforced cement concrete nominal mix 1:1.5:3 Type A1 using 20mm graded stone aggregate as in columns,pillers etc complete all as specified and directed. Note : Reinforcement and form work shall be measured and paid separately.
M&L for Reinforced cement concrete nominal mix 1:1.5:3 Type A1 using 20mm graded stone aggregate as in chajjas etc complete all as specified and directed. Note : Reinforcement and form work shall be measured and paid separately.
M&L for Reinforced cement concretenominal mix 1:1.5:3 Type A1 concrete using 20mm graded stone aggregate as in slabs etc complete all as specified and directed. Note : Reinforcement and form work shall be measured and paid separately.
M&L for Form work to soffits of slab for rough finished surfaces of concrete complete all as specified and directed.
M&L for Formwork to sides of concrete flat footing, plinth beams, complete all as specified and directed.
M&L for Formwork to sides of column square or rectangular in plan for rough finished surfaces of concrete complete all as specified and directed.
M&L for Formwork to soffits of floor or roof beams and gable beams, lintel beams etc complete all as specified and directed.
M&L for Formwork to chullah hoods, chajjas etc complete all as specified and directed.
M&L for Cement concrete type D2 (1:4:8) (using 40mm graded stone aggregate) 75mm thick finished even and fair as in sub base complete all as specified and directed.
M&L for 25mm thick cement concrete type B1,1:2:4 (20mm graded aggregate) as in floors complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc.including raking out of joints, hacking for key,scrubbing down with water etc. any description including disposal of all debris and complete all as specified and directed.
M&L rendering 15mm thick in Cement Mortar 1:4 on other than fair faces of brick surfaces of walls finished the surface fair and even without using extra cement complete all as specifed & directed.
M&L rendering 15mm thick in Cement Mortar 1:6 on fair faces of brick or concrete, external surfaces of walls finished the surface fair and even without using extra cement complete all as specifed & directed.
M&L for prepration of new wall surface and applying 3-6 mm thick wall care putty and applying priming paint followed by two coats of plastic emulsion interior gde paint of any tint on walls complete all as specified and directed. Note : The work should be executed by skilled applicators approved by the manufacturing company.
M & L preparation of new surfaces of walls plastered or unplastered and applying two coats of cement base paint over a coat of primer to walls to obtain uniform surfaces including making good the surface complete all as specifed & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and and including disposal of all debris removed outside MOD land complete all as specified and directed.
Demolition of brick work built in cement mortar of any description and including disposal of all debris and complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius in Cement Mortar 1:6 complete all as specified and directed.
Taking down/Dismantling eaves gutter, rainwater pipes and CI soil,PVC (any type) including all fittings heads,shoes,bends,swan necks etc including cleaning or refixing or removal to store complete all as specified and directed.
S&F 100 mm dia Spun pipe and vent pipes in any length with or without ears, with cement joints, fixed to walls with stack clamps or laid in floors including taking down old one complete all as specified and directed.
S&F in repair 100 mm dia cast iron floor trap including joints, etc complete all as specified and directed.
S&F in repair 100 mm dia cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connections including cleaning or refixing or removal to store complete all as specified and directed.
S&F 15mm GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
S&F 20mm GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
S&F in repair of 18/19mm thick PVC moulded solid board one side prelam for cabinet boxes etc with self and shutter full size fitted under/ above the kitchen cooking platform and other platform including provision of fixing arrangement /fixing & fixtures (magnetic catches,piono hinges and knob etc) complete all as specified and directed.
Dismantling wall ceiling boards (Fibre pulp. Insulation, AC boards,wooden boards etc) or insulation boards/ slabs/ composite panel, etc any thickness complete all as specifed & directed.
M& L for 4mm thick E-board (designer) classic of size 595x595mm fixed to GI anodised snap grid ceiling made of Tee and angle of size 24.5 x 24.5 x1.50 mm thick, size of grid 605 x 605 mm with GI wire suspender 2 to 3 mm dia fixed with wooden/steel truss/rafter flat or slope including taking down old ceiling complete all as specified and directed.
M&L for Ceiling Panels: Pre-Fabricated modular ceiling panels in 50mm thick, with sloping panels PUF panels, between one sheet of 0.8mm and one sheet 0.5mm PPGI (Pre Painted Galvanized Steel) having PUF density of 40 Kg/cum with proper supports. Wall panels will be fixed to the floor with channels and anchor fastener and interlocked with each other through CAM lock system. Ceiling panels will be supports with wall panels through L type flashing, CAM lock system and ceiling supports system as required. Panels including cutouts for lights, pendants, electrical switch sockets etc. Antibacterial & Antifungal paint coating supply and installation of jointless coatings for wall ceiling and corner panels, filling of all jonts and cavities with metal epoxy filler and sanded flush to provide a seamless finish iincluding one primer and three coats of antibacterial and antifungal paint equivalent to a minimum dry firm thickness of 300 microns (Paint- SKK Japan) complete all as specified and directed. Make of PPGI sheet: Tata steel/ Bhushan/ National Make: MHS/ CHP
M&L for Wall Panels: Pre-Fabricated modular wall panels in 50mm thick, with sloping panels PUF panels, between one sheet of 0.8mm and one sheet 0.5mm PPGI (Pre Painted Galvanized Steel) having PUF density of 40 Kg/cum with proper supports. Wall panels will be fixed to the floor with cahnnels and anchor fastener and interlocked with each other through CAM lock system. Wall panels will be supports with wall panels through L type flashing, CAM lock system and ceiling supports system as required. Panels including cutouts for lights, pendants, electrical switch sockets etc. Antibacterial & Antifungal paint coating supply and installation of joint less coating, for wall ceiling and corner panels, filling of all joints and cavities with metal epoxy filler and sanded flush to provide a seamless finish including one primer and three coats of antibacterial and antifungal paint equivalent to a minimum dry firm thickness of 300 microns (Paint- SKK Japan) complete all as specified and directed. Make of PPGI sheet: Tata steel/ Bhushan/ National Make: MHS/ CHP
S&F of PVC Flooring should be with 2mm antistatic seamless PVC flooring, Floor should be smooth, non stlip impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electrical shock.Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided.Thickness not less than 2mm,continious roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratchproof also. The conductive material should be uniformly impregnated as grains.It should be inert to body fluids,chemicals and disinfectants. should not be affected by tempertaure variation within the OT.The floor should be efficiently discharge electric charges up to 2KV.Flooring should be done by skilled workers of accredited agencies authorized by the supplier of PVC sheets.The electrical resistance(Point to ground)should be within 2.5 x 10 power of 4 to 5 x 10 power of 6 Ohms. The floor should be not allow build up of electrical charge beyond 100 Volts due to antistaic effect. The corners should not be terminated sharply and concealed cove-former(aluminium)should be used to overlap the wall panel to a height of approx 25mm and sealed perfectly and uniformly. Self levelling compounds should be used.The conductive copper grid laid underneath the PVC sheet should be supported by liquid epoxy compounds allowed to set as a uniform and level surface. The copper by liquid epoxy compounds allowed to set as a uniform and level surface. The copper strips to be made visible by grinding and no copper strip should project more than 0.5mm above level surface to avoid damage to the PVC sheet. One earthing lead should be made visible by Grinding and no copper strip should project more than 0.5mm above level surface to avoid damage to the PVC sheet. One earthing lead should be brought out from every 150 sq ft area and attaching it to the main earthing strip/ground.Copper grounding strips(0.05mm thick,50m width) should be laid flat on the floor in the conduvtive adhesive and connected to copper strip of grounding. The connection from copper grid should be brought out uniformly at places to form equipotential grid. Flooring should be mechanically shock proof, scratch proof, flame retardant and anti microbial.Corners shuold be uniformly curved. Final surface should be non corrosive to biological fluids an detergent.Colour should be uniform pleasant and matching with ambience. Make: Polyflor/ Tarkett/ Armstrong/ Gerflor/ Tarkett
S&F of 3 Bay scrub sink made out of 304 graded brushed finished stainless steel, 1.6mm thick, 2100mm length, width 565mm, height 1365mm with photoelectric sensors-3Nos, thermo static mixture valves-1Nos, Solenoid valves- 3 Nos with foot operated switch-3 Nos spouts-3 Nos for foam supply complete all as specified and directed. Make: Modular Health Care System/ CMP Metal/ Creative Health Tech Pvt Ltd.
S&F of 2 Bay scrub sink made out of 304 graded brushed finished stainless steel, 1.6mm thick, 1500mm length, width 565mm, height 1365mm with photoelectric sensors-2Nos, thermo static mixture valves-1 No, Solenoid valves- 2Nos with foot operated switch-2Nos spouts-2Nos for foam supply complete all as specified and directed. Make: Modular Health Care System/ CMP Metal/ Creative Health Tech Pvt Ltd.
Taking down aluminium door chowkat any size with shutter including all fittings complete all as specified and directed
Taking alluminium window/ventilators chowkhat any size with shutter including all fittings complete all as specified and directed.
S&F in fabricating and fixing frame and windows of aluminium powder coated of extruded aluminium section two track with two sliding shutters with following sections : (a) Frame section shall be 63.50 mmx38.10 mmx2 mm thick. (b) Two track bottom rail for sliding of shutters 61.85mm x 31.75mmx2mm thick. (c) Two track top section shall be 61.85mmx31.75mmx2mm thick(d) for sliding shutter handle& 'H' bottom section should be 40mmx(18mm+9)mmx1.45mm thick(e) sliding shutter to be provided with 5.5mm thick sheet glass (tinted, plain, frosted) (f) stainless steel wire clothes 0.36mm nominal dia of wire and average width of aperature 1.40mm complete all as specified and as directed.
S&F aluminium powder coated door frame with partially glazed shutters single/ double leaf divided into two glazed panels including aluminium anodised snap beading and rubber gasket/lining for fixing of glass as directed. The frame shall be fixed with aluminium anodised bolt by drilling in the existing wall and with thrust bolt of suitable size all as directed. The frame and shutter will be made out of the following section and fitting (a) Aluminium anodised door frame 101.60 mm x 44.75 mmx2mm fixed with aluminium thrust bolt in walls by drilling as directed. (b) Aluminium anodised sides rail of shutter section 83.5mmx 44.5mm x 2mm (c) Aluminium anodised bottom rail of shutter section 150mm x 44.5 mm x2mm. (d) Aluminium anodised top and middle rail of shutter section 100mm x 44.5 mm x 2mm. (e) Aluminium anodised tower bolt 200 mm long - 02 Nos in each leaf of Make Classic/Argent as approved. (f) Aluminium anodised handle 250 mm long of approved Make Classic/Argent 02. No’s in each leaf. (g) Glass Pane shall be 5.5 mm thick tinted glass. (h) 12mm thick prelaminated particle board laminated both side exterior grade and lock including complete all as specified and directed.
S&F in repair 15 mm bore angle cock with flange, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair soap dish compete all as specified and directed
S&F in repair for towel rail compete all as specified and directed
S&F in repair corner glass shelf 300 mm with ABS brackets complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any guage thickness including roof coverings including ridges etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for drill holes 20mm dia 220mm deep in brick masonry and filling the holes in cement mortar 1:3 and inserting 10mm dia bars in it complete all as specified and directed. (Note: Reinforcement steel measured separately)
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading, levilling, watering and well ramming in layers, not exeecding 25 cm thick using excavated soil complete all as specified and directed.
Removing excavated soil including disposal of all debris distance exc 1.5 Km not exc 5 Km outside of MOD land complete all as specified and directed.
M&L for 10mm thick cement plastering on ceiling surfaces and finished the surfaces even and smooth without using extra cement in cement mortar 1:3 complete all as specified and directed.
M&L for roof treatment with polymeric membrane (APP based) with non woven polyster mat as reinforcement with following:- (a) M&L for cleaning the new plastered surface and providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @0.30 Ltr/Sqm on dry and clean surface. (b) M&L for providing & laying APP based polymeric membrane of 3mm thickness of weight of 3.0 Kg/Sqm with non woven polyster fibre as reinforcement on primed surface by torch application with 15 cm end overlaps & 10 cm side overlaps etc as per manufacturer's instruction. (c) M&L for finishing of top surface by a coat of aluminium paint complete all as specified and directed. Make: Ms Sika India Pvt Ltd/ Ms Fosroc Chemicals/ Ms STP limited/ Ms IWL India limited/ Ms Tiki tar Danosa (India) Pvt Ltd/ Ms Torchtar Membrane & Bitumen Pvt Ltd.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed.
M&L point wiring for modular switches or normal switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through concealed Conduit as requirement of site including cadmium plated screws as per ISS, including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light point controlled by one switch 5 Amps one way single pole complete all as specified and directed.
All as per item No. 65 above but one three pin 5 Amps socket out let on independent board complete all as specified and directed.
All as per item No. 65 above but one three pin 5 Amps socket out let on Same board complete all as specified and directed.
All as per item No. 65 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 16 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed.
All as per item No. 65 above but point wiring of copper cable multi stranded 4.0 Sqmm size for 16 Amps socket outlet on independent board with 4.0 Sqmm size of earth conductor complete all as specified and directed.
S&F in repair Modular switch piano , flush button type , single pole , one way 10 Amps complete all as specified and directed.
S&F in repair Modular switch piano , flush button type , single pole , one way 16 amps complete all as specified and directed.
S&F in repair Modular socket outlet 3 pin and 2 pin , 10 amps , flush type complete all as specified and directed.
S&F in repair Modular socket outlet 2-in-1, 3 pin, 10 and 20 amps , flush type complete all as specified and directed.
M & L Sub main wiring using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit complete all as specified and directed. Note: Two runs of 2.5sqmm copper FRLS cable & one run of 2.5 sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit.
M & L Sub main wiring using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit complete all as specified and directed. Note: Two runs of 4sqmm copper FRLS cable & one run of 4.0 sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit.
M & L Sub main wiring using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit complete all as specified and directed. Note: Two runs of 6 sqmm copper FRLS cable & one run of 6.0 sqmm copper cable in and including 32mm PVC conduit medium grade will be measured as one unit.
M & L submain wiring using four run PVC insulated FRLS Copper conductor 10 sqmm with rigid non metalic PVC conduit of size 32 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 10 Sq mm etc complete all as specified and directed. Note: four runs of 10 sqmm copper FRLS cable & one run of 10 sqmm copper cable in and including 32 mm PVC conduit medium grade will be measured as one unit.
M & L submain wiring using four run PVC insulated FRLS Copper conductor 16 sqmm with rigid non metalic PVC conduit of size 40 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 16 Sq mm etc complete all as specified and directed. Note: four runs of 16 sqmm copper FRLS cable & one run of 16 sqmm copper cable in and including 40 mm PVC conduit medium grade will be measured as one unit.
S & F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 507611 or equivalent in Siemens / Schnieder/ L&T/ ABB/ C&S Electric/ Havells
S & F in repair with taking down distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 12 way with 200 Amps rated copper busbar, 415 Volts with in built MCCB 160 Amps, 10 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 507748 or equivalent in Siemens/ Schnieder/ L&T/ ABB/ C&S Electric/ Havells
S & F in repair MCB TPN, 415 Volts, 40-63 Amps complete all as specified and directed.
S & F in repair MCB SPN, 240 Volts, 32-63 Amps complete all as specified and directed.
S & F in repair MCB SP, 240 Volts, 6-40 Amps complete all as specified and directed.
Supply and fix in replacement Energy efficiency clean room bottom opening recessed mounted 42 W LED luminire for hygenic facilities suitable for 2 x 2 grid ceiling along with flat diffuser along with constant current electronic driver complete all as specified and directed. Make : Havells # BOCR2X2R42WLED857SPCMS/ Philips/ Bajaj/ Crompton Greaves/ C&S Electric/ Halonix
S &F in repair Earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 5 of SSR of part-I (1991) complete all as specified and directed by Engr-in-charge.
Supply and fix in repair for Moduler metal Flush box complete all as specified and directed for the following :- Make :- Anchor Woods/ Philips/ Legrand
3 module
4 module
6 module
8 module
S&F in replacement of modular white cover plate with frame , 3 module complete all as specified and directed.
S&F in replacement of modular white cover plate with frame , 4 module complete all as specified and directed.
S&F in replacement of modular white cover plate with frame , 6 module complete all as specified and directed.
S&F in repair of modular white cover plate with frame square type , 8 module complete all as specified and directed.
Material and labour in repair for earthing complete with gavanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtrs below gorund level) with top edge of the plate not less than 1.5mtr beolw normal ground level, connected to galvanised earth strip 32 x 6mm size upto a distance of 7.5 mtr long by means of bolts , check nuts and washers of galvnised steel , watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm) with cast iron frame, with charcoal, salt, funnel complete all as shown in the electrical plate No 5 of SSR part –I and testing on completion complete all as specified and directed. Note:-Quoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
X-Ray View Panel Supply, installation testing, commissioning of X -ray viewer with following specifications complete all as specified and directed. Specifications: - Light : LED light display - Display : 2 Film display - Dimensions - 880 x 503 x 29mm - Auto film insertion Operations: - Flicker free luminance for the film viewing purpose - Provision for brightness control - Digital Dimmer for high quality film interpretation Installation / Fitment: - flushed with theatre wall for hygienic and ease of cleaning purpose.. Make : Bio-X/ Pratibha medinox/ Digiline systems
Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from location to MES store yard complete all as specified and directed.
PLENUM : LAF 8ft x 6ft Supply, installation testing, commissioning of Plenum with following specifications 1.Plenum MOC : Stainless steel 304, Thickness 1.2mm 2.Plenum Size : 8ft x 6ft 3.Plenum Diffuser Grill : The high quality S.S.304 - Diffuser grill for securing unidirectional air flow according to EN ISO 14644. 4.Diffuser grill : SS 304 grill designed to deliver uniform air velocity across the entire HEPA plenum to maintain uniform air displacement on the OT table. Thickess : 1.2mm 5.Filter housing and pressure chamber : MOC stainless steel 304 matt polish, thickness 1.2 mm. 6.Filter section : - Mini-pleat (H14) grade HEPA Filters - Filters to be tested to remove practices sizing up to 0.3.micron. 7.Hepa Filter size & qty.: - Total 6 nos Filters - Total Filter Area : 44 Sq.ft. for 8ft x 6ft - Make : Camfil/ Frudenberg/ American Filters 8.Plenum Lights : LED light box on all 4 sides with LED tubes Box size 200mmx2000mm. LED tube light of 18watt - 6 nos. total Make :- Western India Electromedical Systems Pvt. Ltd./ Tanvi enterprices/ Hospedia Medicare Pvt. Ltd./ Airotek Systems
OUT DOOR TYPE ALL WEATHER AIR HANDLING UNIT CFM & STATIC : 4000 CFM & 125mm static Supply, installation testing, commissioning of outdoor type Building managment base Smart AHU with remote operating monitoring system installed on anti vibration pads and supports as per OEM recommendation with following equipments and its specifications - AHU with integrated control system Monitoring and controlling all AHU parameters like temperature, humidity, air flows, filters, damper and actuator status saves handsome quantum of thermal and electrical energy as well as operations parameters with inbuilt sensors and accuators with dampers ( For supply, Return, Fresh Air and Exhust Ducts) and sensors as required to control and monitor on PLC . The cost for AHU has inclusive of all controlling, monitoring and saftey interlock equipments and sensors along with its connected control and power wiring and PLC and its control internal and external panels . AHU has built in with Temperature and RH sensors and one set of Temperature and RH sensor has installed inside OT Room for continous monitoring of OT rooom temperature with supply air temp at AHU outlet duct along with connected control wiring and cabling , HMI screen with SCADA compitable devices and instruments , Differential pressure transmitter for continous monitoring of filter and for the calculated the CFM through differential pressure monitoring inside OT Room and inside AHU with control wiring., AHU should consist of Air Quality Sensors CO2 & VOC and connected with PLC MAKE : ZECO / CITIZEN / LOYDDS
SMART AHU CAPACITY – Air Handling Unit should be capable to deliver 4000 CFM at 125mm Static Pressure. CASING – The housing / casing of Air Handling unit shall be of double skin construction. Casing frame work shall be of extruded aluminum section with thermal break barrier aluminum profiles. Thermal Break Double skin panel shall be made of outer skin 0.8mm pre coated GI sheet and inner skin 0.6mm plain stainless steel sheet, insulation in both skin should be 45mm thick CFC free puff injected insulation of 40KG/ cubic meter density. Panel should be screwed to the frame work with soft gasket to make air tight joint. Suitable doors with powder coated hinge shall be provided for access to maintenance. Low leakage of AL constructed volume control dampers with suitable actuator should be providing for Return Air / Fresh Air / Exhust Air / Supply Air. DRAIN PAN – Shall be constructed 18G ss-304 sheet with closed cell nitrile insulation. The pan has necessary slop to facilitate for fast removal of condensate. FAN – EC fan motor should be provide with direct couple arrangement. EC motor should be alongwith Modbus communication for control arrangement as per OEM recommendation. Make – Ziehl-abegg/ Rosenberg
COIL – Direct expansion cooling coil suitable for 4000 CFM, min. 8sqft face area should be constructed as below parameters. Coil casing-18G SS-304 Coil RD – 6-8 (suitable with the required tonnage) Coil Tube MOC – Copper, Dia – 3/8”, Tube Thick. – 0.5mm IGT Coil Fin MOC – hydrophilic coated Al, Fin thick. – 0.15mm, Fin spacing – 11-12 FPI Coil test pressure should be 550-600 PSIG HEATING COIL – Hot water type heating coil parameters as below Coil casing-18G SS-304 Coil RD – 2 Coil Tube MOC – Copper, Dia – 1/2”, Tube Thick. – 0.5mm Coil Fin MOC – hydrophilic coated Al, Fin thick. – 0.15mm, Fin spacing – 8-10 FPI Coil test pressure should be 300 PSIG Header material – Cu with MS adaptor FILTER – Flange type EU-4 and EU-5 should be providing on common frame before cooling coil in suction area, and EU-7 should be mounted on positive side of the fan. Filter mounting arrangement / mounting frames should be made of GI 16G OR suitable to the application. FILTER Make - American Air Filter / Fewdenburg REME – REME should be provided as per the recommendation of OEM and as per the capacity of smart AHU.
SMART AHU CONTROLS AND SENSORS – AHU should be supply alongwith below parameters sensors and controllers with suitable electrical control panel, also having PLC display to insert and change the parameters on the AHU with IOT based mobile application.Control and power cabling should be provided for all sensor and power & Control cabling should be done as recommended by OEM and MMIC panel with thouch screen should be installed inside OT room to control and monitor all parameters and to control and regulator the same from inside the OT room. The control and power wiring should be done with PVC conduting heavy grade and lay in factory fabricated power coated and painted GI perforated cable trays with support as per OEM recommendation and should be covered with dust and weather proof factory fabricated power coated and painted GI cover. The smart AHU should contain following equipments as per OEM recommendations :- Temperature sensors and controllers RH sensors Differential pressure sensors to maintain running air quantity DP switches across filters and coils. SAFTY :- Limit Switch – fan section all doors should be provided with fitment of limit switch and lamps.Fan section door should be providing with wire guard to protect any casual entry inside the AHU.Fan suction port should have diffusion plate.
FIRE :- The smart AHU have necessary provision with Fire damper with acuator and inline exhust fan working on around 150°C and other than that PLC of AHU should take command from smoke and fire indicator and should shutoff supply and return air damper and open fire damper and start exhust fan all this provision should be provided with AHU and control wiring and cabling should be done from OT room to AHU ( Appx 15 Mtr distance) AHU CONTROL PANEL : Supply, installation testing, commissioning of AHU control panels with following specifications - PLCs, MCB for AHU, MCB for AC, Contractors for controlling etc all as recommended and specified by OEM. PRESSURE SENSOR IN SIDE OT ROOM :- one pressure sensor as per OEM recommendation should be provided inside OT room to monitor and to maintain positive pressure inside OT room . EC fan and PLC inside AHU should vary its speed as per setting carried out inside MMIC panel
Supply , Installation , testing and commissioning 16 HP VRF based outdoor unit with Heat pump system and inverter driven capacity control compressor ,with special acryl pre coated e-pass heat exchanger , low noice condenser fan with DC motor, auto check function for connection error , auto address setting etc ( 2 piping system for Heating and cooling ) complete with Control Kit EEV for operating the locally provided AHU with direct expansion heat exchanger coils in connection with VRF system , ( EEV-KIT is composed of EEV control ASSY and one EEV - set as recommended by OEM to operate 16 HP out door unit and AHU ) MS stand and coonected accessories and control and power copper cabling , Wire remote control and display screen all as recommended by OEM of VRF machine compitable with PLC/BMS based smart AHU as mentioned in AHU item ser NO 95 with following specifications with 70 KVA servo voltage stablizer suitable for 3 Phase, 50 HZ , 4 wire system all as specified and directed by Engg-in-charge. Make: Mitsubishi Heavy Industries Model No :- FDC450KXZE1 and EEV Kit Model No EEV6- 280 - E or equivalent in Daikin/ O General Capacity: 16 HP Power Sourch: 3 Phase, 380-415V, 50 HZ Nominal Cooling KW: 45 KW Nominal Heating KW: 45 KW Electrical Characteristics: Staring current: 8 A Running current Heating Mode: 20.4 to 18.7 A Running current Cooling Mode: 22.4 to 20.5 A
Exterior dimensions: 2048 x 1350 x 720 mm Net wight: 317 KG Refrigerent charge: R410A in complete system including AHU complete Sound pressure level in Heating / Cooling: 61 /62 db(A) Refrigerent piping size: Liquid line: dia 12.7 mm ( 1/2") Gas Line: dia 25.58 mm ( 1 1/8")
Note :- (i) Contractor shall arrange factory inspection / Training schedule for minimum three nos JE E/M & AGE E/M to train all person about the system and fault finding mechanisum for electrical and electronic circuit upto satisfaction of all the person. (ii) Contractor shall provide following air conditioning tools to the MES for day to day maintenance of VRF system:- (a) Total Ricovery unit heavy duty ( Gas & Oil for central AC plant) - 03 Nos all as approved by engg -in-charge (b) Dual Stage Vaccum pump for central AC Plant of specification Flow rate :- 12 CFM , ultimate vacuum :- 2x10-1 pa - 03 Nos (c) Charging line universal type - 06 Nos (d) Gauge manifold - 03 Nos (e) oxigen and LPG cylinder kit 5 Ltr cap combined with brazing torch , flexible rubber hose miniumum 20 mtr length, regulating valves for both oxigen and LPG cylinder compete all as specified and directed by engg -in-charge - 03 Nos set (f) flaring tools complete set all as specified and directed by engg -in-charge- 03 nos
M&L for DOP testing and commissioning of HEPA filters installed under Laminar Flow System as per Item No 95 above. The testing method should conform to test norms and filter construction norms as laid down in IES-RP-34.1 (HEPA and ULPA filter leak test) and test norms as laid down in EN1822 and IES-RP-CC001.3 (HEPA & ULPA filters). Test methods, on site validation methods, leakage definitions and method of testing should be strictly followed. The contractor will submit detailed test report for satisfactory test result for all HEPA filters duly recommended by Engg-in-charge or auth representative detailed by the accepting officer.
Refrigerant "Y" joint required for distribution copper piping as per recommended by OEM suitable for Capacity 16 HP complete all as specified and directed. Make :- Mitsubishi Heavy Industries Model No :- FDC450KXZE1 or equivalent in Daikin/ O General
Supply, install testing and commissioning refrigerant copper piping covered with 19mm thick closed cell elastomeric nitrile rubber tubular insulation, between each set from AHU to VRF unit as per OEM standards and supported with MS hangers complete all as specified and directed by Engg-in-chrge for following sizes:-
38.1 mm dia
34.92 mm dia
28.58 mm dia
22.22 mm dia
19.05 mm dia
15.88 mm dia
12.7 mm dia
9.52 mm dia
6.4 mm dia
Supply, install testing and commissioning of 2 core 1.5 sqmm 1100V grade PVC insulated copper conduction laid in 20 mm dia medium grade PVC conduit with necessery clamp complete all as specified and directed by Engg-in-charge.
Supply, install, testing and commissioning of MS Heavy Duty "C" class Hot water piping duly painted with red oxide primer of following dia liad on floor/ roof / wall and making hole in wall complete with tee, bends and supports and all accessories duly insulated with 40 mm PUF pipe sections insulation complete with 26 guage aluminium sheet cladding over pipe complete all as specified and directed for the following sizes:-
Supply , fixing , Testing and comissioing of water type butterfly valve with cst iron body , seat of black nitrie rubber , nylon coated S..G. Iron disc , PTFE coated SS ( AISI 410 ) shaft . Complete with companion flanges, nuts, bolts, gaskets tec as required. These valves shall confirm to BS:5155 MSS SP.67 & API. 6098 and shall be designed to fit without gaskets between mating and seal in both direction . The valves shall be of integral moulded design complete all as specified and directed for the following sizes:-
65 mm dia
50 mm dia
Supply , install , testing and commissioning of horizontal type pan humidifer complete with suitable size of PVC water tank , Pumps, Spray nozzle piping and electrical accessories complete all as specified and directed by Engg-in-charge
Supply, install,testing and commissioning of Duct mounted inline fans of GI construction complete with centrifugal fan with motor , canvas connection at inlet & outlet complete with MCB & relays , cabling & earthings etc all as specified and directed by Engg -in-charge.
Supply , install, testing and commissioning rigid UPVC piping of following dia complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation all as specified and directed by Engg-in-charge for the following sizes:-
40 mm dia
32 mm dia
Ducting : Supply, installation, testing & commissioning including hanging and supporting with necessary MS Supports including fabrication works for hanging of aluminum ducting complete with turning vanes, supports, flanges etc with 22 Gauge aluminium sheet all as specified and directed by Engg-in-charge
Insulation : Supply, install, testing and commissioning of Duct insulation with 25mm thick Nitrile Rubber insulation of class "o" fire retardant with protective coating 32 mm thick insulation with Mechanical protection over insulation with fiber glass cloth & UV paint (for exposed duct) for Ducts installed outside, (exposed to sunlight) complete all as specified and directed by the Engineer-in-charge.
Insulation : Supply, install, testing and commissioning of Duct insulation with 25mm thick Nitrile Rubber insulation of class "o" fire retardant without protective coating for Ducts installed in False ceiling complete all as specified and directed by the Engineer-in-charge.
Supply, installation testing, commissioning of GI Fire damper with fusible link for return air complete all as specified and directed by engg-in-charge
Supply, installation testing, commissioning of risers with following specifications Triagular Return air riser inside OT room approximate 3.2 mtr height of SS 202 with insulation. Each riser with 11 watt Germicidal UV light ,GRILL WITH DAMPER : Return air grills SS 304 with damper to control airflow and connected with upto exhust air manifold inside AHU all as specified and directed by Engg-in-charge Make : Western India Electromedical Systems Pvt. Ltd./ Tanvi enterprices/ Hospedia Medicare Pvt. Ltd.
Taking down the existing medical gas out let terminal units, oxygen flow meter, hummidifier, copper tube with fitting angle tray copper tubes upto 28mm dia, medical gas monitoring alarm system refixing the same (thourgh wall and painting with colpur code practise complete all as specified and directed.
Supply, install, testing and commissioning in replacement of hard drawn seamless non phophorous deoxidezed non arsenical half head tampered and degreased copper pipe manufacturer as per BS-2871 Part-I table 1971 and chemical composition as per BS-6017 of table-2 CUDHP complete with all fittings in replacement of Medical grade copper pipe of dia 12 mm outer dia and wall thickness 0.7 mm thick. Make :- Germs/Max FLow/ Metal Export
S&F in replacement of old oxygen gas out let with matching stainless stell probes complete all as specified and directed.
S&F in replacement of old vaccum gas outlet with matching stainless stell probes complete all as specified and directed.
S&F in replacement of old MA4 with matching stainless stell probes complete all as specified and directed.
Supply, Installation Testing & Commissioning in replacement of Weatherproof Analogue Addressable Manual Call Point with Integral Short Circuit Isolator. The call point shall have Fast response, Integral short-circuit isolator, Bi-coloured status LED, Non-frangible element fitted as standard (conforms to EN54), Surface mounted, IP67 rated, LPCB approved to EN54 complete all as specified and directed by Engg-in-charge Make: Honeywell/ Siemens/ Panasonic/ Hochiki/ Edwards/ APPOLO
Supply, Installation Testing & Commissioning in replacement of microprocessor based Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity up to 16 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated RS232 serial port for optional printer. Approved by LPCB complete all as specified and directed by Engg-in-charge Make: Honeywell/ Siemens/ Panasonic/ Hochiki/ Edwards/ APPOLP
S & F in replacement Rigid steel conduit of 20 mm dia for fire fighting system control cables including juntion box with cover for connecting on roof and wall of OT complete all as specified and directed.
Supply and fixing in replacement grade heavy wire with PVC insulated copper solid conductor 1.5 sq. Mm nominal cross section for fire fighting system complete all as specified and directed.
Taking down / Dismantling carefully the automatic sliding door and connected wiring and other item complete making the surface normal for fixing new door complete all as specified and directed.
supply and fix Hermatically sealed automatic sliding door 5ft x 7ft for Operation theater complete all as specified and directed by engg -in-charge with following specificaitons :- MOC : HPL Sloping Top. RAIL CONSTRUCTION : Aluminum Profile DOOR BLADE : 60 Mm Thick With 0.6mm HPL On Both Sides. The Above Panel Will Be Framed In Anodized Aluminum Profiles. GASKET : On All 4 Sides Of The Door Blade Is A Special Rubber Gasket. OPENER : Stainless Steel Lever Handle On Both Sides WINDOW : 300mm X 300mm DOOR FRAME : Single Aluminum Frame Profile, Fixed To Finished Wall, Not Wall Surrounded AUTOMATION : Electric, Type SDA-04, 230V SAFETY : Photocell In The Frame SWITCHES : Radar Hand Switch, Foot Switch LOCK : Manual lock with MEDICAL EARTHING Make : Western India Electromedical Systems Pvt. Ltd./ Tanvi enterprices/ Hospedia Medicare Pvt. Ltd.
supply and fix Hermatically sealed automatic sliding door 4ft x 8ft for Operation theater complete all as specified and directed by engg -in-charge with following specificaitons :- MOC : HPL Sloping Top. RAIL CONSTRUCTION : Aluminum Profile DOOR BLADE : 60 Mm Thick With 0.6mm HPL On Both Sides. The Above Panel Will Be Framed In Anodized Aluminum Profiles. GASKET : On All 4 Sides Of The Door Blade Is A Special Rubber Gasket. OPENER : Stainless Steel Lever Handle On Both Sides WINDOW : 300mm X 300mm DOOR FRAME : Single Aluminum Frame Profile, Fixed To Finished Wall, Not Wall Surrounded AUTOMATION : Electric, Type SDA-04, 230V SAFETY : Photocell In The Frame SWITCHES : Radar Hand Switch, Foot Switch LOCK : Manual lock with MEDICAL EARTHING Make : Western India Electromedical Systems Pvt. Ltd./ Tanvi enterprices/ Hospedia Medicare Pvt. Ltd.
Supply , install, testing and commissioning of 30 KVA on line UPS with inbuilt isolation transformer and connected Battery Rack and link & Accessories including battery bank suitable for 15 Min back up with 2 Set of 34*12V/42AH Batteries with and including connected accessories as per OEM standards complete all as specified and directed by Engg -in-charge. Make :- EMERSON/ SCHINDER/ SIEMENS Note :- Detail specificaiton for UPS metioned in PS
Supply & laying in replacement XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 70 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in replacement XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in replacement XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 35 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in replacement XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Material and labour in replacement for earthing complete with gavanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtrs below gorund level) with top edge of the plate not less than 1.5mtr beolw normal ground level, connected to galvanised earth strip 32 x 6mm size upto a distance of 7.5 mtr long by means of bolts , check nuts and washers of galvnised steel , watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm) with cast iron frame, with charcoal, salt, funnel complete all as shown in the electrical plate No 5 of SSR part –I and testing on completion complete all as specified and directed. Note:-Quoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
Supply and installation, testing, commissioning, in replacement factory made, CPRI approved, outdoor type feeder piller Box, confirming to IS:5039 with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including MS angle section 40 x 40 x 5 mm thick MS frame with front and back openable, double door with provision of locking arrangement dust & varmin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specifed and directed & Consisting of the following equipments :- Note:- PCC & Excavation inclusive in qouting rates (a) Incoming :- (i) MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 315Amps rating and 35 KA : 01 Nos. (b) Outgoing:- (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,160 amps rating and 25 KA rupturing capacity. Nos - 02 (ii) MCCB 4 pole, LT 415 volts, 50 Hz AC grade, 100 amps rating and 25KA rupturing capacity. Nos - 03
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading, levilling, watering and well ramming in layers, not exeecding 25 cm thick using excavated soil complete all as specified and directed.
Removing excavated Soil to a distence not exceeding 50 m and deposting where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thicness of sand only will be considered.
Supply and Laying burn brick size 225 mm X 113 mm X 75 mm etc complete all as specified and directed.
M/s JAIMAA ASSOCIATES
Chauhan Associates
N K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .