| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.1 L+₹1.4 L (6.01%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹25.4 L+₹2.7 L (11.8%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
22 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Jaisalmer
GE Army Jaisalmer - 345001
PROVN OF BATHROOMS WITH TOILET AND OTHER SANCTIONED MINOR WORKS AT MIL STN JAISALMER
2022_MES_510141_1
8167/21-22/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹46,000
Yes
31 Mar 2022
24 Feb 2022
24 Mar 2022
24 Feb 2022
22 Mar 2022
8 Mar 2022
60 days
Amount
Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in soft/loose soil complete all as specified & directed by Engineer-in-charge.
Excavating in post holes (or similar holes) in hard/dense soil, each not exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50 Mtr and making good surface complete all as specified & directed by Engineer-in-charge.
Excavating in post holes (or similar holes) in soft/loose soil, each not exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50 Mtr and making good surface complete all as specified & directed by Engineer-in-charge.
S&F rolled mild steel roof trusses (framed), trussed, purlins, crane, gantries, rails and fastening and heavy bracket framing (Beams, tee, angle, channel or flat sections) including distance pieces, cleat etc conforming to Fe-410-W Gde E-250 quality-A complete all as specified & directed by Engineer-in-charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F wind ties for roof including securing bolts including cutting tops to shape as directed, drilling holes, etc flat iron fillets including all necessary drilling, bolting or riverting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and apply two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer all as specified & directed by Engineer-in-charge
M&L for 75 mm thick plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring finished the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for 100 mm thick plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring/hardstanding finished the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for 500 mm thick plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in sub base of flooring/hardstanding finished the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M & L Machine pressed precast concrete interlocking paver block rubber moulded, any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified & directed by Engineer-in-charge.
M&L for precast cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in block masonry with solid blocks exceeding 10cm width and setting in cement mortar (1:6) complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
M&L for rendering 10 mm thick in cement mortar (1:6) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for rendering 10 mm thick in cement mortar (1:4) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for rendering 5mm thick on fair faces of concrete surfaces in ceiling in CM( 1:3), finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and apply two coats of cement base paint over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L preparation of new plastered surfaces and apply three coats of white wash on wall surfaces complete all as specified and directed by Engineer-in-charge.
M&L preparation of new plastered surfaces and apply three coats of white wash on ceiling surfaces complete all as specified and directed by Engineer-in-charge.
S&F 5 cm thick sand stone slabs Jaisalmer pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar (1:4) complete all as specified & directed by Engineer-in-charge.
M&L Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in cement lime (1:3) or cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 40 mm graded stone aggregate) average 40mm thick as in padding complete all as specified & directed by Engineer-in-charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified & directed by Engineer-in-charge.
S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed by Engineer-in-charge.
S&F 150 mm long Aluminium handles, cast type, anodised complete all as specified & directed by Engineer-in-charge.
S&F, 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & directed by Engineer-in-charge.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded all as specified & directed by Engineer-in-charge.
S&F, 3mm thick, figured glass, pin head type and glazing with oil putty in squares not exceeding 0.50 sqm in each panes complete all as specified & directed by Engineer-in-charge.
S&F 1000 litres capacity, three layered, white colour Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified & directed by Engineer-in-charge.
S & F Vitreous china wash down water closet pan (Pedestal pattern), white (EWC) with seat cover (Excluding flushing cistern and flush pipe) complete all as specified & directed by Engineer-in-charge.
S&F vitreous china wash basin white, flat back of size 550 x 400 mm white including waste fittings, brass, chromium plated, coupling, waste pipe, brackets including cutting for and pinning in ends of brackets errect stand, fixing waste pipe complete all as specified & directed by Engineer-in-charge.
M&L for non skid ceramic coloured tiles of size 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified & directed by Engineer-in-charge.
S&F glazed ceramic coloured tiles of size 350 x 250mm x 7mm /450mmx350mmx7mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F 15 mm bore, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia & PVC connection 15mm size, 450 mm long with PTMT nuts complete all as specified & directed by Engineer-in-charge.
S&F 15 mm pillar taps fancy type, cast copper alloy with capstan heads, chromium plated, screed down high pressure, with or without lettered 'Hot; or 'cold' with long screwed shanks and fly nut, screwed for iron pipe and fixed, complete all as specified & directed by Engineer-in-charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-charge.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed by Engineer-in-charge.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and directed by Engineer-in-charge.
S&F 75 mm bore (SWR) PVC bends any radius with access door complete as directed by Engr-in-Charge.
S&F 110 mm bore (SWR) PVC bends any radius with access door complete as directed by Engr-in-Charge.
S&F 75mm bore PVC (SWR) vent cowl all as specified & directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) vent cowl all as specified & directed by Engineer-in-charge.
S&F steel water tubing (ISI marked) medium grade galvanised, 15mm bore with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing (ISI marked) medium grade galvanised, 20mm bore with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore stop cock, fancy type, chromium plated, with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for union complete all as specified & directed by Engineer-in-charge.
S&F PVC ball valve 15mm dia high pressure of PTMT with polythene float and fly nut with epoxy coated aluminum rod complete screwed for iron pipe or brass ferrule all as specified & directed by Engineer-in-charge.
S&F gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the 20mm sizes with ISI marked and as per IS 14846 all as specified and directed by the Engineer-in-Charge.
S&F gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the 40mm sizes with ISI marked and as per IS 14846 all as specified and directed by the Engineer-in-Charge.
S&F PVC connections 450mm long, 15mm size with PTMT nuts for WHB, flushing cistern, geysers etc complete all as specified & directed by Engineer-in-charge.
S&F 32mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified & directed by Engineer-in-charge.
S&F Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed by Engineer-in-charge.
S&F tubular towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges fixed with chromium plated brass screws complete all as specified & directed by Engineer-in-charge.
M&L 100 mm size cast iron floor trap, with grating including jointing to waste pipe fixed in cement conrete (1:2:4) type B-1 complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) laid in alternative bays as in plinth protection including finished the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25, 3 parts of sand by weight complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore stop valve, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for union complete all as specified & directed by Engineer-in-charge.
S&F 20 mm bore stop valve, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for union complete all as specified & directed by Engineer-in-charge.
M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement morter 1:4 on fair face of brick wall or concrete surfaces, finished even & smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for point wiring with two single core PVC insulated unsheathed multistranded copper cable of size 4.0 Sqmm 1100 Volts grade drawing into and incl PVC cassing capping with all accessories and one single core PVC insulated unsheathed multi stranded copper cable of size 4.0 sqmm, 1100 Volts grade as earth continuity conductor connected to common earth dolly termination directed for sheet metal enclosure box as directed by Engineer in charge.
S & F sheet metal enclosure Geyser / AC Box having 20 Amp MCB SP as incomer complete all as specified
Supply & fixing of water heater storage type (Geyser) vertical type, with steel inner container of capacity 25 Ltr, power Consumption 2 KW, BEE 5 star rated pressure rating >8 Bar, Powder coated metal body with PUF insulation electrically operated 230 Volt complete all as specified and directed by Engineer-in-charge.
M & L for PVC connection pipe (copper) chromium plated 8 mm dia both end threaded incl brass coupling bolt cone washer complete, length of pipe is not less than 450 mm suitable for Hot/Cold water system complete all as specified and directed by Engineer-in-charge.
M&L Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.6 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
M& L Point wiring with 1100 volts grade PVC insulated FR multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.6 mm covered with 3 mm thick phenolic laminated white sheet cover for one 15 amp socket outlet controlled by one switch on independent board complete.
M& L Point wiring with 1100 volts grade PVC insulated FR multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.6 mm covered with 3 mm thick phenolic laminated white sheet cover for one 15 amp socket outlet controlled by one switch on independent board complete.
S&F switch piano flush button single pole one way 5/6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F socket outlet 2 in 1, 3 pin, 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete.
S & F surface and wall mounted LED tube light along with fixture, 4 ft, 22W, extruded aluminium housing provided for efficient heat disspation with polycarbonate, operating voltage 240 V, 50HZ, AC supply and operating tempureture 0 to 50 C, power factor >0.9, lumen output > 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified and directed by Engineer-in-charge.
S & F LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified and directed by Engineer-in-charge.
S&F LED bulkhead fitting 10/12watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired for connection with flexible multi stranded copper conductor cable as required complete all as specified and directed by Engineer-in-charge.
S&F angle holder, insulated polycabonate body with back plate complete all as specified and directed by Engineer-in-charge.
S & F for MCB DB SPN 8 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed by Engineer-in-charge.
Supply and fixing of building security light fitting LED 35 watt IP65 with fixing arrangment such as GI pipe bracket 40 mm grade, 1.2 mtr long, MS Clamp, Nut Bolts etc and connecting complete all as specified and directed by Engineer-in-charge. (Make : havells Cat No ENDURA CITYLITEPLATPLATPLUSSL 35WLED 757SASYBOPC or as equivalent from list of makes)
S&F MCB distribution board TPN, 415 volts, 4 ways double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB Triple pole and neutral 415 Volts 40 to 100 Amp ,50 Hz 10 KA, rapturing capacity 'C' curve complete all as specified and directed by Engineer-in-charge.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in casing caping including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge. (Note :- Two runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length)
S&F MCB distribution board SPN, 240 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 40 to 63 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB's single pole 20 Amps to 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve.complete all as specified & directed. Make-Schneider/Legrand/Havells
S&F exhaust fan steel body AC single phase 230V of size 300 mm sweep with blades and frame and louvers with Cutting of wall with mason for making window suitable for fixing of 300 mm exhaust fan and making good as per existing surface of wall complete all as specified and directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron wire 4mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion complete all as specified and directed by Engineer-in-charge.
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized seel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed by Engineer-in-charge.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized seel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed by Engineer-in-charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as specified & directed by Engineer-in-charge. (Note :- For the purpose of payment, punned thickness of sand cushioning shall only measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified and directed by Engineer-in-charge.
Supply, transportation fixing and errection of Steel Tubular Swaged poles complete with cast iron base plate, finial taper pulg, bolts, nuts and screws as specified type 410 SP-31 (9.0 meters long) and including making alternate white and black strips 30cm height (Total 05 Nos) with two coats of synthetic enamel paint over a coat primer complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 (using 40mm grade stone aggregate) in foundation of pole/struts etc including necessary form work complete all as specified and directed by Engineer-in-charge.
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm grade stone aggregate) in foundation of stay assembly/pole including necessary form work complete all as specified and directed by Engineer-in-charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm grade stone aggregate) for coping/encasing around of pole including necessary form work finished and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing (ISI marked) light grade galvanised, 40mm bore (ISI Marked) laid in trenches, as in cable protection complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing (ISI marked) light grade galvanised, 40mm bore (ISI Marked) laid in trenches for earthing strip protection complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing (ISI marked) light grade galvanised, 25mm bore (ISI Marked) laid in trenches, as in cable protection complete all as specified and directed by Engineer-in-charge.
M&L for road cutting for laying of GI pipe for cable protection including returning, filling in trenches after laying of pipe and making good the top 200mm thick with PCC (1:2:4) type B-2 (40mm graded stone aggregate) and removing surplus soil to a distance n.exc. 50m complete digging after laying of pipe line / cable making good the surface complete all as specified and directed by Enginner-in-charge. Note :- GI pipe will be measured and paid separately).
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engineer-in-charge.
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to poles or any other indicated situation for loop earthing as required 4mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-charge.
S & F of security light bracket with GI pipe light grade of size 40mm dia bent to shape of length 1.2 meter including flat iron clamp made of FI 40 mm x 6 mm, nuts, bolts, washers etc (Two sets) duly painted with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
S&F pole mounting box made out of PVC FR grade (Syntex) with bus bar - 03 Nos for phase & 01 No for Neutral 32 Amps supported on insulators and 02 Nos. MCB 10 Amps, clamp made out of FI 25x4mm nuts, bolts and washers etc duly painted with two coats of synthetic enamel paint over a coat of red oxide primer on clamp complete all as specified and directed by Engineer-in-charge.
S&F PVC insulated copper conductor 2.5 sq mm 3 Core drawn through and including PVC conduit medium grade with necessary fixing arrengements and connecting items complete all as specified and directed by Engineer-in charge.
Supply and fixing feeder pillar box out door type not less than 0.60 M X 0.60 M X 0.60 M made out of 3 mm thick CRCA sheet powder coated dust & vernin proof supported on angle iron frame 40X40X5 MM, aluminium bus bar 03 Nos rated capacity 300 Amps for phase and 01 No rated capacity 200 Amps for neutral supported on porcelain insulator including painting with two coats of synthetic enamel paint first quality) over a coat of red oxide primer and PCC foundation complete all as specified & directed by Engineer-in -Charge.
M&L Air termination, single pointed copper rod 12 mm dia 300 mm long with base fixing complete all as specified and directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to copper strip 32x6mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engineer-in-charge.
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with copper strip of 32X6 mm size complete all as specified and directed by Engineer-in-charge.
M & L Earthing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex. head screw.Material and labour for testing/termination point made out of 32 x 6 mm copper strip of length 150 mm duly housed in suitable MS box insulators etc for linking the down conductor and the earth terminals of the lightening arrester system complete all as specified and directed by Engineer-in-charge.
Supply and fix insulators made out of porcelain for fixing the lightening roof conductor and the down conductor complete all as specified and directed by Engineer-in-charge.
Cutting the existing 80 mm bore pipe CI/DI pipes and reducing to required length in position for insertion and including of new tees (80x80x25mm), branches, etc complete all as specified and directed by Engineer-in-charge.
Supply and Lay steel water tubing (ISI marked) medium grade galvanised, 40mm bore with necessary fittings (ISI Marked) laid in trenches, jointed and tested complete all as specified and directed by Engineer-in-charge.
Supply and Lay steel water tubing (ISI marked) medium grade galvanised, 20mm bore with necessary fittings (ISI Marked) laid in trenches, jointed and tested complete all as specified and directed by Engineer-in-charge.
Supply and fixing hi wall inverter split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser, plasma filter for beer indoor air quality with minium 5 star rating and EER 3.2 of capacity of 2 TR (including gas charging if required) complete all as specified and directed by Engineer-in-charge.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed by Engineer-in-charge.
S & F of integral LED street light luminaire 70 W IP 65 comprising of epoxy powder coated housing, enclosed with glass cover in frame on MCPCB complete all as specified and directed by Engineer-in-charge.
Leelashah Enterprises
S K TRADER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .