Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
15 Jun 2024, 6:00 pmClosed
Garrison Engineer
GE (U) Chandimandir Pin-134107
GE(U)/CHM-49/2023-24 PREVENTIVE MAINTENANCE / REPAIR OF DG SETS UNDER GE (U) CHANDIMANDIR
2024_MES_648149_1
GE(U)/CHM-49/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Chandimandir
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (U) Chandimandir
₹54,000
Yes
3 Sept 2024
28 Mar 2024
19 Jun 2024
28 Mar 2024
15 Jun 2024
1 Jun 2024
Amount
Servicing and overhauling of self starter of DG set 12 Volt of cap 10 KVA to 75 KVA i.e. opening, checking and cleaning of self including replacement of carbon bushes if required and making it free from dust and reassembling after replacement of UNSV worn out parts if required for smooth operation and reinstallation to DG set of any make/model complete as per satisfaction of Engineer-in-Charge. Note: cost of replacement of carbon bushes is included in the rates quoted against this item however other spares required for making self serviceable will be paid separetely in relevant items of schedule hereinafter.
Supplying and fixing as in replacement of burnout solenoid switch as per site requirement and as directed by Engineer-in-Charge.
M & L for Rewinding of burnout armature of self as per site requirement and as directed by Engineer-in-Charge.
Servicing and overhauling of self starter of DG set 12 Volt of cap 100 KVA i.e. opening, checking and cleaning of self including replacement of carbon bushes if required and making it free from dust and reassembling after replacement of UNSV worn out parts if required for smooth operation and reinstallation to DG set of any make/model complete as per satisfaction of Engineer-in-Charge. Note: cost of replacement of carbon bushes is included in the rates quoted against this item however other spares required for making self serviceable will be paid separetely in relevant items of schedule hereinafter.
Supplying and fixing as in replacement of burnout solenoid switch as per site requirement and as directed by Engineer-in-Charge.
M & L for Rewinding of burnout armature of self as per site requirement and as directed by Engineer-in-Charge.
Servicing and overhauling of self starter of DG set 12/24 Volt of cap 125 KVA to 250 KVA i.e. opening, checking and cleaning of self including replacement of carbon bushes if required and making it free from dust and reassembling after replacement of UNSV worn out parts if required for smooth operation and reinstallation to DG set of any make/model complete as per satisfaction of Engineer-in-Charge. Note: Cost of replacement of carbon bushes is included in the rates quoted against this item however other spares required for making self serviceable will be paid separetely in relevant items of schedule hereinafter.
Supplying and fixing as in replacement of burnout solenoid switch as per site requirement and as directed by Engineer-in-Charge.
M & L for Rewinding of burnout armature of self as per site requirement and as directed by Engineer-in-Charge.
Servicing and overhauling of self starter of DG set 24 Volt of cap 320 KVA to 500 KVA i.e. opening, checking and cleaning of self including replacement of carbon bushes if required and making it free from dust and reassembling after replacement of UNSV worn out parts if required for smooth operation and reinstallation to DG set of any make/model complete as per satisfaction of Engineer-in-Charge. Note: cost of replacement of carbon bushes is included in the rates quoted against this item however other spares required for making self serviceable will be paid separetely in relevant items of schedule hereinafter.
Supplying and fixing as in replacement of burnout solenoid switch as per site requirement and as directed by Engineer-in-Charge.
M & L for Rewinding of burnout armature of self as per site requirement and as directed by Engineer-in-Charge.
Servicing and overhauling of self starter of DG set 24 Volt of cap 750 KVA to 1010 KVA i.e. opening, checking and cleaning of self including replacement of carbon bushes if required and making it free from dust and reassembling after replacement of UNSV worn out parts if required for smooth operation and reinstallation to DG set of any make/model complete as per satisfaction of Engineer-in-Charge. Note: cost of replacement of carbon bushes is included in the rates quoted against this item however other spares required for making self serviceable will be paid separetely in relevant items of schedule hereinafter.
Supplying and fixing as in replacement of burnout solenoid switch as per site requirement and as directed by Engineer-in-Charge.
M & L for Rewinding of burnout armature of self as per site requirement and as directed by Engineer-in-Charge.
Repair/ replacement of (AVR) automatic voltage regulator Diode forward and reverse rotating rectifier assembly, half wave phase controlled thyristor type, complete all as per existing type & size for DG set of capacity 10 to 40 kVA, complete all as specified and directed by Engineer-in-Charge.
All as per item No 06 above but for DG set of capacity 62.5/75/125 KVA .
All as per item No 06 above but for DG set of capacity 160/180/200/250 KVA .
All as per item No 06 above but for DG set of capacity 500/400/320 KVA .
All as per item No 06 above but for DG set of capacity 750/1010 KVA .
Taking out of Radiator/Aftercooler from DG set 10 KVA to 75 KVA of any make/model and cleaning of radiator by removing of dust/oil particles and cleaning of copper tubes by using suitable cleaning agent for any obstacles inside the tube and refixing it complete all as directed by Engr-in-Charge.
All as per item No 11 above but for DG set 100 to 160 KVA .
All as per item No 11 above but for DG set 180 KVA .
All as per item No 11 above but for DG set 200 to 250 KVA .
All as per item No 11 above but for DG set 320 to 500 KVA .
All as per item No 11 above but for DG set 750 to 1010 KVA .
Disconnecting and taking down the leaking radiator from DG set engine and transporation to civil workshop for repairs, cleaning the complete radiator for detecting the leakage and repairing the leaking portion (Tubes/fins/tank etc) by soldering/brazing, cleaning of all water tubes with suitable cleansing agent & water pressure & removing the complete sludge and dust from inside the tank, replacing worn out hose pipes & clamps etc, shifting & refixing at original site and testing for proper working, for the DG set of capacity 10 to 160 KVA, complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down the leaking radiator from DG set engine and transporation to civil workshop for repairs, cleaning the complete radiator for detecting the leakage and repairing the leaking portion (Tubes/fins/tank etc) by soldering/brazing, cleaning of all water tubes with suitable cleansing agent & water pressure & removing the complete sludge and dust from inside the tank, replacing worn out hose pipes & clamps etc, shifting & refixing at original site and testing for proper working, for the DG set of capacity 200 to 500 KVA, complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down the defective Charging Alternator from the DG set engine, shifting to civil workshop for repairs, strip opening to remove unserviceable parts, repairing by replacing of armature coil, carbon bush, field coil, clutch patti bearing, refixing magnetic steel laminates, replacing pole head and pole shoe, bearings of shaft ball/roller/sleeve type, and other related items of the assembly as required to make it serviceable, re-assembling and refxing the same on original position and testing complete for the DG set of capacity 10 to 75 KVA, complete all as specified and directed by Engineer-in-Charge.
All as per item No 19 above but for the DG set of capacity 125 to 250 KVA .
All as per item No 19 above but for the DG set of capacity 320 to 500 KVA
M & L for opening the tappet covers of the engine of the DG set of capacity 10 to 40 KVA of any make and carrying out repair works such as checking and adjustment of tappet clearance, and cylinder heads by removing carbon deposits , checking general condition of the engine, checking and adjustment of operating parameters, checking and adjustment of fuel timings, checking and adjustment of fault warning system, checking & tightening of various fasteners and connections, refixing the tappet covers, incl replacing the worn out gaskets/nuts/bolts/washers etc, complete all as specified and directed by Engineer-in-Charge.
All as per item No 22 above but of the DG set of capacity 125 to 250 KVA.
All as per item No 22 above but of the DG set of capacity 320 to 500 KVA.
All as per item No 22 above but of the DG set of capacity 750 to 1010 KVA.
Servicing of DG Set 750/1010 KVA capacity of Make :- Kirloskar/Cummins/Crompton Greaves, taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:- (i) Spare parts such as fuel filters/Water Separator Filter (Primary and secondary), by pass filters, lube oil filters, air cleaner element set filters shall be measured and paid for saperately under respective items here in after.
Supply only Fuel filter assembly with 'O' rings
Supply only Lube oil filter assembly with 'O' rings
Supply only Bypass filter assembly with 'O' rings
Supply only Air cleaner element set.
Servicing of DG Set 500/400 KVA capacity of Make :- Kirloskar/Cummins/Crompton Greaves, taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:- (i) Spare parts such as fuel filters/Water Separator Filter (Primary and secondary), by pass filters, lube oil filters, air cleaner element set filters shall be measured and paid for saperately under respective items here in after.
Supply only Fuel filter assembly with 'O' rings
Supply only Lube oil filter assembly with 'O' rings
Supply only Bypass filter assembly with 'O' rings
Supply only Air cleaner element set.
Servicing of DG Set 320/250 KVA capacity of Make :- Kirloskar/Cummins/Crompton Greaves, taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:- (i) Spare parts such as fuel filters/Water Separator Filter (Primary and secondary), by pass filters, lube oil filters, air cleaner element set filters shall be measured and paid for saperately under respective items here in after.
Supply only Fuel filter assembly with 'O' rings
Supply only Lube oil filter assembly with 'O' rings
Supply only Bypass filter assembly with 'O' rings
Supply only Air cleaner element set.
Servicing of DG Set 200 to 160 KVA capacity of Make :- Kirloskar/Cummins/Crompton Greaves , taking down worn out replaceable parts such as fuel filters (Primary and secondary) , by pass filters, lube oil filters, air cleaner filters, water separators filters, lube oil flexible pipe, hose pipes, clamps etc and replacing the same with same size, make and capacity of parts, and including testing, complete all as specified and directed. Note:- (i) Spare parts such as fuel filters/Water Separator Filter (Primary and secondary), by pass filters, lube oil filters, air cleaner element set filters shall be measured and paid for saperately under respective items here in after.
Supply only Fuel filter assembly with 'O' rings
Supply only Lube oil filter assembly with 'O' rings
Supply only Air cleaner element set.
Servicing of DG Set 125 KVA capacity of Make :- Kirloskar/Cummins/Crompton Greaves, taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:- (i) Spare parts such as fuel filters/Water Separator Filter (Primary and secondary), by pass filters, lube oil filters, air cleaner element set filters shall be measured and paid for saperately under respective items here in after.
Supply only Fuel filter assembly with 'O' rings
Supply only Lube oil filter assembly with 'O' rings
Supply only Air cleaner element set.
Servicing of DG Set 100 KVA capacity of Make :- Kirloskar/Cummins/Crompton Greaves, taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:- (i) Spare parts such as fuel filters/Water Separator Filter (Primary and secondary), by pass filters, lube oil filters, air cleaner element set filters shall be measured and paid for saperately under respective items here in after.
Supply only Fuel filter assembly with 'O' rings
Supply only Lube oil filter assembly with 'O' rings
Supply only Air cleaner element set.
Servicing of DG Set 62.5 to 75 KVA capacity of Make :- Kirloskar/Cummins/Crompton Greaves , taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:- (i) Spare parts such as fuel filters/Water Separator Filter (Primary and secondary), by pass filters, lube oil filters, air cleaner element set filters shall be measured and paid for saperately under respective items here in after.
Supply only Fuel filter assembly with 'O' rings
Supply only Lube oil filter assembly with 'O' rings
Supply only Air cleaner element set.
Servicing of DG Set 10 to 40 KVA capacity of Make :- Kirloskar/Cummins/Crompton Greaves , taking down worn out replaceable parts such as lube oil flexible pipe, hose pipes, clamps etc and replacing the same with same size, make and capacity of parts, and including testing complete all as specified and directed. Note:- (i) Spare parts such as fuel filters/Water Separator Filter (Primary and secondary), by pass filters, lube oil filters, air cleaner element set filters shall be measured and paid for saperately under respective items here in after.
Supply only Fuel filter assembly with 'O' rings
Supply only Lube oil filter assembly with 'O' rings
Supply only Air cleaner element set.
Material and labour for overhauling of all injecter nozzles including all as per site requirment, washers etc and pressure setting as required and replacement of timing shaft with coupling for DG sets of 750 to 1010 KVA capacity, complete all as specified and directed. .
All as per item no 34 above but for DG sets 400 to 500KVA .
All as per item no 34 above but for DG sets 320/250 /200KVA .
All as per item no 34 above but for DG sets 125 to180 KVA .
All as per item no 34 above but for DG sets 100 KVA .
All as per item no 34 above but for DG sets 62.5 to 75 KVA .
All as per item no 34 above but for DG sets 40 to 10 KVA .
Disconnecting and taking down the fuel pump from the DG engine, transporting to civil workshop and repair & calibration of FIP of DG Set including replacement of plungers, washer manifold, injection nozzles etc all as required and testing after refixing on engine and setting the rated RPM, for DG set of capacity 750 to 1010 KVA, complete all as specified and directed.
All as per item No 41 above but for DG sets 320 to 500 KVA .
All as per item No 41 above but for DG sets 125 to 250 KVA .
All as per item No 41 above but for DG sets 100 KVA .
All as per item No 41 above but for DG sets 10 to 75 KVA .
M&L for draining out the engine oil from the sump, opening the sump cover, cleaning properly to remove old oil stucked to the surfaces, replacing the worn out gaskets/nuts/bolts/washers as required & refixing the sump cover, for 750 to 1010 KVA capacity DG set engine, complete all as specified and directed.
All as per item No 46 here in before but for DG set 400 to 500 KVA capacity DG set.
All as per item No 46 here in before but for DG set 320/250/200 KVA capacity DG set.
All as per item No 46 here in before but for DG set 180/160/125/75 KVA capacity DG set.
All as per item No 46 here in before but for DG set 100 KVA capacity DG set.
All as per item No 46 here in before but for DG set 62.5/40/10 KVA capacity DG set.
Supply and filling engine oil grade 15W40 premium grade, complete all as specified and directed. Make :- Castrol/HP/Bharat Petroleum
Supply and filling distilled water in batteries for toppping up, complete all as specified and directed.
M&L for draining out old coolant from the engine radiators of DG Sets of any capacity and make, flushing the radiator tubes with distilled water and filling with new coolant, refixing the drain plug properly and filling the complete radiator with new pre mixed coolant, complete all as specified and directed. Make: Servo/Castrol/HP/Bharat Petroleum
Supply and fix in replacement battery leads set for battery of any capacity installed at various power Houses appx 1.5 Mtr long, PVC insulated multistranded copper conductor of size 35 sqmm single core, duly fixed brass clamps, copper lugs for connections from DG battery to self starter on DG Sets of any capacity all as specified and directed.
Supply and fixing in repairs heavy duty copper cable of size 35 sqmm single core battery leads (Red and black ), complete all as specified and directed.
Supply and fixing in repairs heavy duty brass terminals (as per approved sample) suitable for battery terminals complete all as specified and as directed.
M & L for cleaning the in-built diesel tanks of 750 to 1010 KVA capacity DG set by emptying the tank using suction pump of suitable capacity, washing the internal walls & bottom with diesel to remove any dust / deposits etc complete all as specified and as directed.
All as per item no 58 above but for DG set capacity 320 to 500 KVA
All as per item no 58 above but for DG set capacity 160/180/200/250 KVA
All as per item no 58 above but for DG set capacity 10/40 KVA
All as per item no 58 above but for DG set capacity 125/100/ 62.5/75 KVA
M&L for repairing the doors of sound proof enclosure of 750 to 1010 KVA DG Set for proper closing and locking using new SS hinges/door handles / in built locks complete all as per existing all as specified and directed.
All as per item No 63 above but for DG set 320 KVA to 500 KVA DG set
All as per item No 63 above but for DG set 10 KVA to 40 KVA DG set
All as per item No 63 above but for DG set 62.5 KVA to 200 KVA DG set
Supply and replacing V belt set ( for fan & alternator) for 750 to 1010 KVA DG set engine of make Kirloskar/CG/Cummins etc complete all as per existing and as specified and directed
All as per item No 67 here in before but for DG set 500 to 400 KVA capacity DG set.
All as per item No 67 here in before but for DG set 320 KVA capacity DG set.
All as per item No 67 here in before but for DG set 250 KVA capacity DG set.
All as per item No 67 here in before but for DG set 200KVA capacity DG set.
All as per item No 67 here in before but for DG set 180 KVA capacity DG set.
All as per item No 67 here in before but for DG set 160 KVA capacity DG set.
All as per item No 67 here in before but for DG set 125 KVA capacity DG set.
All as per item No 67 here in before but for DG set 75 KVA capacity DG set.
All as per item No 67 here in before but for DG set 62.5 KVA capacity DG set.
All as per item No 67 here in before but for DG set 40 KVA capacity DG set.
All as per item No 67 here in before but for DG set 10 KVA capacity DG set.
S & F as in replacement maintenance free lead acid sealed lead accumilater (SMF) 12 volts 180 Ah complete all as specified and as directed.
S & F in replacement maintenance free lead acid sealed lead accumilater (SMF) 12 volts 100 Ah complete all as specified and as directed.
S&F off load changeover 4 Pole 415 V 200 Amp 50 Hz side operated, with sheet metal enclosure, complete all as specified and as directed
S&F off load changeover 4Pole 415 V 100 Amp 50 Hz side operated, with sheet metal enclosure, complete all as specified and as directed.
S&F off load changeover 4Pole 415 V 63 Amp 50 Hz, side operated, with sheet metal enclosure, complete all as specified and as directed.
Attending defective/ non functional DG Set complaints of capacty 10 KVA to 1010 KVA (all type of errorr/fault alarms displayed on screen of the control panel) by service engineers/technically qualified teams to rectify the defects by made adjustments/settings in control panel or to inform the major/minor repair that include cost more than Rs 500 to make DG Serviceable of any type as per existing, checking of connections, testing and DG Set should working in good conditions etc complete all as specified and as directed. Notes Srl Item No 84:- (a) On receiving of complaint, it should be attended by service Engineer /rep of OEM within 24 Hrs, if not attended penalty @ Rs 500 per hour will be recovered from contractor. Failure on the part of contractor to make the DG Set functional on very same day after receipt of complaint, penalty @ Rs 1500 per day will be recovered from contractor. (b) All type of T & P, minor nuts/bolts/washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department. (c) Repair item costing less than Rs 500 to make DG Serviceable is deemed to be included in the quoted rate of item.
M & L for repair of the in-built diesel tanks of 40 capacity DG set by emptying the tank using suction pump of suitable capacity, washing the internal walls, welding/solding leakage of diesel tank of bottom and washed with diesel to remove any dust / deposits etc, complete all as specified and as directed.
M&L for replacement of magnetic sensor for 400 KVA capacity DG set of make Kirloskar/CG /Cummins etc all as per existing, including replacing the worn out gaskets/nuts/bolts/washers etc, complete all as specified and as directed.
M&L for replacement of water pump for 200 KVA to 250 KVA capacity DG set of make Kirloskar/CG /Cummins etc all as per existing, including replacing the worn out gaskets/nuts/bolts/washers etc, complete all as specified and as directed.
Supply and fix of onload changeover switch with sheet metal enclosure of cap 200 amps in replacement of UNSV/burnout Changeover switch complete all as specified and as ditected by Engineer-in -Charge.
Supply and fix of onload changeover switch with sheet metal enclosure of cap 100 amps in replacement of UNSV/burnout Changeover switch complete all as specified and as ditected by Engineer-in -Charge.
Supply and fixing of asbestos rope to exhaust pipe of DG set of any Cap as per existing size and colour as directed by Engineer in Charge
Supplying, fixing and connecting panel mounting type battery Charger with transformer diode operated (not PCB) 12/ 24 Volts, 30 Amps with copper winding including removing the unserviceable from the existing position complete all as directed.
Supply and fixing in replacement of UNSV Turbo Charger suitable for 75 to125 KVA DG Set of make Greaves/Kirloskar/Cummins all as directed by Engineer-in-Charge.
Supply and fixing in replacement of UNSV Turbo Charger suitable for 160 to 250 KVA DG Set of make Greaves/Kirloskar/Cummins all as directed by Engineer-in-Charge.
M&L for preparation of old painted surfaces of the DG Set including radiator, fuel tank etc complete degreasing and spray painting the same with two coats of approved fire proof metal paint including writing SM/MES nos on DG set of capacity 10 to 125 KVA all as directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of the DG Set including radiator, fuel tank etc complete degreasing and spray painting the same with two coats of approved fire proof metal paint including writing SM/MES nos on DG set of capacity 250 to 160 KVA all as directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of the DG Set including radiator, fuel tank etc complete degreasing and spray painting the same with two coats of approved fire proof metal paint including writing SM/MES nos on DG set of capacity 320 to 500 KVA all as directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of the DG Set including radiator, fuel tank etc complete degreasing and spray painting the same with two coats of approved fire proof metal paint including writing SM/MES nos on DG set of capacity 750 to 1010 KVA all as directed by Engineer-in-charge.
M & L for Replacement of UNSV mechanical Governor for DG Set of Cap 75 to 160 KVA of any make all as directed by Engineer-in-charge.
M & L for decoupling the alternator from the engine , taking down from the foundation, transportation to civil workshop, dismantling complete to take out the rotor assembly, properly cleaning of alternator /stator windings/bearings etc with blower & dry cloth, varnishing & drying up of the windings in suitable furnace to improve insulation value, greasing of the bearings with high quality grease, tightening of terminal connections incl replacing worn out sleeves/ nuts/bolts/washers etc, re-assembling complete, shifting back & refixing at original position, making perfect alignment with the engine and testing all as specified and as directed for the DG set of Capacity 750/1010 kVA at CH
M & L for decoupling the alternator from the engine , taking down from the foundation, transportation to civil workshop, dismantling complete to take out the rotor assembly, properly cleaning of alternator /stator windings/bearings etc with blower & dry cloth, varnishing & drying up of the windings in suitable furnace to improve insulation value, greasing of the bearings with high quality grease, tightening of terminal connections incl replacing worn out sleeves/ nuts/bolts/washers etc, re-assembling complete, shifting back & refixing at original position, making perfect alignment with the engine and testing all as specified and as directed for the DG set of Capacity 180 kVA at CH
S & F in replacement HRC fuse 200 amps capacity DIN type or bolted type all as directed. Make :- L&T/C&S/Schneider/BCH
M & L for replacement of locks for sound proof canopy of any make as per recommendation of OEM
Servicing of AMF panel of DG set 100-180 KVA of capacity cleaning the complete panel with suitable cleaning agent and checking the controller relays, timer, contactors for proper functioning, replacing defective spare parts, replacement of defective small wires of existing size, tightening of all connections and applying jelly on contactors,panel locks etc complete all as specified and directed by Engineer-in-Charge. Note : (i) Spare parts required will be measured and paid separately as 'Supply Only' but cost of small wires shall be included in the quoted rate.
Supply only 4 pole contactor 250 Amps, suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Supply only display digital meter (with volt & ammeter meter) suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Supply only AMF Logic controller relay complete assembly suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Supply only Control relay complete assembly suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Supply only Timer assembly complete suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Supply only Auto / Manual switch complete assembly suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Supply only Start/stop push button complete assembly suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Supply only CT unit, class-1 (200/5A ratio ) complete assembly or suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Servicing of AMF panel of DG set 500 KVA of capacity installed at CMS by cleaning the complete panel with suitable cleaning agent and checking the controller relays, timer, contactors for proper functioning, replacing defective spare parts, replacement of defective small wires of existing size, tightening of all connections and applying jelly on contactors, panel locks complete all as specified and directed by Engineer-in-Charge:- Note : (i) Spare parts required will be measured and paid separately as 'Supply Only' but cost of small wires shall be included in the quoted rate.
Supply only Control relay complete assembly suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Supply only Timer complete assembly suitable for existing (make & model) DG set AMF Panels, 3 Phase, 415 Volts, 50 Hz.
Supply only undervoltage coil suitable for existing (make & model) DG set AMF Panels
Supply only triping coil suitable for existing (make & model) DG set AMF Panels
Supply only closing coil for existing (make & model) DG set AMF Panels
S&F only LED indicator lamp assembly red, yellow, blue complete all as specified and as directed.
M&L earthing complete with galvanized steel plate electrode 60cmx60cmx6mm surrounded by charcoal & salt buried directly in a pit of depth not less than 2.25m below ground level with top edge of the earth plate at a depth of not less than 1.50m below ground level, connected to and including GI srtip 32x6mm. upto 7.5m length by means of bolts, nuts, check nuts & washers of galvanized iron, earth wire protected by galvanized steel pipe 15mm bore (medium grade) & connected to main control board including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore GI pipe (medium grade) for watering, funnel, wiremesh, PCC chamber in cement concrete (1:2:4) type B-1, CI cover & frame etc) complete all as indicated in electric plate No 3 of SSR 2009 Part I including testing complete all as specified and as directed. Note- (i) Earthing result/data sheet will be prepared by the Contractor and submitted to Engineer-in-charge. Earth resistance shall be to the entire satisfaction of engineer-in-charge and contractor will make all arrangements & provisions to get the desired reduction of resistance by artificial treatment/replacement of soil etc at no extra cost to department.
Repair, Servicing and maintenance of ACB of existing make and 800-1250 amps capacity installed at Generator Room and CMDC including:- (i) Cleaning and assembling of front cover , push button , locking latches. (ii) Cleaning of terminal shield. (iii) Cleaning and assembling of chassis. (iv) Cleaning and tightening of every point of auxiliary and control unit connector block. (v) Cleaning, greasing and assembling of hand pull-out system, racking Mechanism of chassis and function position indicators. (vi) Cleaning, checking and assembling of arc chute. (vii) Physical inspection of main contact. (viii) Cleaning, checking/testing and assembling of tapping coil/ closing coil. (ix) Cleaning and greasing of mechanical charging system. (x) Cleaning, greasing and installation of jaw contacts. (xi) Repair of lower mechanism if found faulty. (xii) Final testing of the Air circuit breaker manually.
POWER TECH ENGINEERS
PARTAP ENGINEERING WORKS
J H CONSULTANTS
M/S RAGBIR ENGINEERING SERVICES
KAPOOR ENGINEERS
SANJEEV ENTERPRISES
Jai Maa Electrical Works
Bharat Enterprises
NARINDER KUMAR SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .