Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.8 L+₹2.2 L (7.98%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹32.3 L+₹4.7 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹33.9 L+₹6.3 L (23.0%)Rejected-Finance 894 NEAR 132 KV POWER HOUSE SINDHARI ROAD BALDEV NAGAR BARMER RAJ 344001 | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹35.4 L+₹7.8 L (28.3%)Rejected-Finance VILL MOKHAWA TEHSIL GUDAMALANI DIST BARMER RAJASTHAN 344031 | GUDAMALANI | BARMER | RAJASTHAN | 344031 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Mar 2024, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR/MAINT OF LT PANEL, SERVICE CABLE AND MAIN DBS OF BPS INCLUDING LIGHT FITTING AND REPAIR/MAINT OF DG SETS AT 3 AFRU, CONTROL CABLE, LT CABLES AND OTHER CONNECTED WORK AT CERTAIN UNIT AND DOMESTIC AREA AT AF STN JAISALMER
2024_MES_644598_1
8203/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹80,000
Yes
18 May 2024
29 Feb 2024
1 Apr 2024
29 Feb 2024
30 Mar 2024
16 Mar 2024
Amount
M&L for maintenance and servicing of DG Set of capacity 7.5 KVA to 75 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing rubber hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed by Engineer-in-Charge.
M&L for maintenance and servicing of DG Set of capacity 80 KVA to 160 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as directed.
Supply in repair the following items from 7.5 KVA to 160 KVA
(a) Control Safety(Water)
(b) Control Safety (Lub Oil)
(c) Gauge Water Temp.(54')
(d) Gauge Low Temp.(96')
(e) Gauge Lub Oil Pressure
(f) Techohourmeter
Supply and filling in sump / topping up engine oil, multi grade 20w / 40 in engine or relpacement of engine oil Make :- Indian oil / Hindusthan petrolium / Castrol / Pried /Servo complete all as specified and directed by Engineer-in-Charge.
S&F, Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 0.3 mtr long.
S&F, Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 1.50mtr long.
Supply and fix in repalcement of AVR card suitable for 7.5 KVA to 75 KVA DG Set as per existing.
Supply and fix in repacement of AVR card suitable for 83 KVA to 160 KVA DG Set as per existing.
Supply only Premixed Coolent(35 Ltr),container
Supplying and filling distilled water best quality suitable for lead acid battery, complete all as specified and directed by Engineer-in-Charge.
S&F, controller suitable for 60 KVA to 83 KVA DG set, CPCB -I, slilent type as per existing complete all as specified and directed
Supply and fixing , contactor 3 pole 32-55 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Supply and fixing, contactor 3 pole 80-85 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I (1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 50 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as directed at site.
M&L for tibba sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
M&L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable complete including taking up of old protection material all as specified and directed.
M&L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M&L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Supply&laying, passing through GI pipe, commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs complete all as specified and directed. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
(a) 10 Sqmm 2 core
(b) 10 Sqmm 4 core
(c) 16 Sqmm 4 core
(d) 25 Sqmm 4 core
(e) 35 Sqmm 3.5 core
(f) 50 Sqmm 3.5 core
Taking down of old unserviceable LT cable from 10 sqmm 2 core to 16sqmm 4 core complete all as spefied and directed.
M&L for GI Tubes, of following size, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road for protection of LT cables or earth strips etc complete all as specified and as directed.
(a) 40 mm bore
(b) 50 mm bore
Drilling (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm complete all as specified and directed.
Supply and fixing in repair energy efficient LED Post top light fittings made in die cast aluminium bottom and spun aluminium to reflector with decorative clear acylic diffuser and IP65 protection, with higher efficiency lighting of capacity not less than 25 Watt, range 140-280 volts with surge protection inbuilt in driver for maximised protections, driver should be potted type for viberation proof performance in & includings making electrical connections and taking down of old fittings of any type and size, mountiung arrangements, complete all as directed at site.
Supply and fixing, LED flood lights not less than 120 watts, nominal voltage 240 volts, 50 Hz, high efficiency long life LED module with SMD LED package mounted on MCPCB, lumen efficacy of LED shall not be less than 120 lumen/W, individuals LED's should have lenses for better throw across Colour temp (CCT) -5700K and viewing angle of 120 degree to ensure better uniformity, epoxy powder coated pressure die cast aluminium housing elegantly designed heat sink for efficient thermal management, high quality toughened glass IK 07 fixed to housing, having electronic driver, integral, isolated electronic driver with lower THD, output open/short circuit protection, over voltage protection, surge voltage protection with external SPD not less than 10 KV and other safety test as per IS 15885 Part-2/Sec 13, having adjustable MS cradle of thickness 5mm provided in and including taking down of existing lights of any type complete all as specified and directed,
Supply, fixing, connecting and testing LED bollard light decorative type with reflector not less than 10 watt , IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution having fixing arrangements at bottom with necessary nuts, bolts, washers complete in and including taking down of old unserviceable lights complete all as specified and directed,
Supply and fixing in repair energy efficient LED street light fittings of 60 Watt, pressure die cast alluminium housing with prismatic poloycarbonate modular secondary lens optics, IP-66 degree of protection,140-280 volts fittings should be provided 5 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector inbuilt in driver for maximised protections, should have lumens output of 100 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections and taking down of old unserviceable lights of any type all as directed.
Supply and fix for junction box made out of Fiber reinforced Plastic with IP 55/IP 65 protection of size250x200x105 mm , 5 way having terminals for termination of cable with necessary nuts and bolts , including -02 Nos cable gland - 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps Make - Legrand in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as directed.
Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles/pipe/ platform/ paths etc including necessary form work and finished surfaces complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and connecting elastomer insulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 including taking down of old unserviceable connection wire complete all as specified and directed.
Supplying and fixing, service cable 10sqmm, twin core, 1100 volts grade heavy duty cable PVC stranded insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire including taking down of old service wire complete all as specified and directed.
Supplying and fixing , 6 sqmm , twin core, 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, including taking down of old service wire complete all as specified and directed.
S&F in replacement of 20mm outer dia, 3 layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded olypropylene random fittings fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete all as specified and directed.
M&L in replacement for MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed by Engineer-in-Charge.
M&L for Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947 in and including providing of one No MCCB of 160 Amps, 4 Pole, 25 KA, 50 Hz 415 Volts . The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom and having welded equal angle of 75mmx75mmx6mm of length 0.9mtr, 04 Nos, 30cm of of angle shall be embedded in PCC 1:2:4, 20mm graded stone agregate below GL level and 30cm shall be above ground level of size as directed by Engr-in-charge at site The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling/taking down of old unserviceable complete. Note:-The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 700mm height (without base frame & canopy), 700mm width and 500mm depth).
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised as earthing lead wire 4.0mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) in and including taking down of old earthing (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
M&L for Earthing complete with CPRI tested 50mm dia, pure copper earth electrode pipe of length 3000mm, pipe in copper strip Technology with NABL tested, RoHS compliant earth enhancement compound 50 Kg in each bore hole in tripod configuration (three numbers of 50mm dia pure copper electrode pipe) interconnected with copper strip of size 20x3 mm and connected by means of exothermic brazing & porected by GI pipe light grade 32mm bore and PCC (1:3:6) type C1 earth chamber & cast iron earth pit cover 300x300x3mm connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed and taking up/Dismantling of old earthing. Note:- (i) Cost of copper strip 20x3mm and 32mm dia GI pipe light grade required for interconnection of three numbers of pure copper 50mm dia earth electrode is deemed to be included in unit quoted rates. Copper strip of suitable size from earth pit to test point/equipment shall be measured and paid seperately. (ii) Cost of earth work, boring, PCC earth pit, CI cover, testing of earth after completion, connecting and commissioning is deemed to be included in unit quoted rates. (iii) Marking & painting of earth pit with iron plate of suitable size is deemed to be included in unit quoted rates. (iv) The boring will take place for 3 meter depth & 350mm dia for three numbers of pure copper earth electrode pipe to form tripod configuration. Earth enhance compound to be filled around the earth electrode in 100mm dia in 3 layers of 1 mtr each by means of PVC pipe of 100mm dia as casing/formwork.The remaining volume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1 mtr each.The PVC pipe to be removed simultaneously.The cost of all this is deemed to be included in the quoted rate. (v) Minimum distance between each earthing is not less than 3 running meter. (vi)Testing of earthing shall be conducted and result should be less than 1.00 Ohms.
S&F in replacement change over switch 250 Amps ON load in sheet enclosure four pole to be fixed on wall with flat iron 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed.
S&F in repair for concealed Sub main wiring with 2 run of single core 4.0 Sqmm multi-stranded copper conductor 1100 volts grade FRLS PVC insulated unsheathed cable drawn through and including PVC conduit of suitable size duly concealed in wall including 2.50Sqmm PVC insulated unsheathed single core copper conductor earth wire in and incuding cutting of chases making good to concealed conduit wiring etc,cutting not exc 10cm girth and making good to match the existing surface complete all as specified and as directed. Note:- Three run of wire shall be measured in each unit.
M&L in repair for concealed Sub main wiring with 2 run of single core 6.0 Sqmm multi-stranded copper conductor 1100 volts grade FRLS PVC insulated unsheathed cable drawn through and including PVC conduit of suitable size duly concealed in wall including 4.0 Sqmm PVC insulated unsheathed single core copper conductor earth wire in and incuding cutting of chases making good to concealed conduit wiring etc,cutting not exc 10cm girth and making good to match the existing surface complete all as specified and as directed. Note:- Three run of wire shall be measured in each unit.
S&F, single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps, 240 Volts and top complete all as specified and as directed
Supply and fix in repalacement of battery,12 V 150 AH, 25 plates including testing for its proper functioning as specified and directed by Engr-in-Charge. Make Exide/Amron. Note :- Battery shall be original make accepted No substitute of battery.
Supply and fixing in replacement LED aviation obstraction lights not less than 10 watt, 230 volts, 50 Hz comprising of aluminium housing with Polycarbonate enclosure, suitable for outdoor application complete all as specified and directed.
Supply and fix, Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral complete all as directed by Engineer-in-Charge.
Supply and fix, Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 12 way (2 + 10 way) single pole and neutral complete all as directed by Engineer-in-Charge.
Supply and fix, factory made sheet metal enclosure double door distribution board class IP-43 IK-09 with 200Amp rated copper bus bar 415 Volts, 4 way TPN complete all as directed by Engineer-in-Charge.
S&F for Sheet Metal enclosure for VTPN DBs, 4 Ways, Double Door(IP-43), built- in bus bars complete suitable for 415 Volts, AC, 50 Hz supply, suitable for incoming MCCB and outgoing MCBs and fixed in recess in brick masonary wall complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing, amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of of rating SP 5 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing, amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of of rating SPN 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing, amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of of rating SPN 40 to 63 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing , 415V 10KA 'B' curve miniature circuit breaker (MCB) of TP (Tripple Pole) 25 to 63 AMP current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing , 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP 40 to 100 AMP current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing, MCCB 3 pole 100 Amps rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Routine and periodical cleaning the inside area of 11 KV Sub Stations including cutting and removal/uprouting of unwanted grass/bushes, small trees near all around sub station and pump houses complex complete including surface dressing and leveling by surface excavation wherever as required or as directed.
Scrubbing of existing paints of existing LT panel board where rusted, LT feeder Pillar boxes, LT bus bar chamber paints of any specification and removing old paints and preparation of surfaces for painting complete and M&L for painting of LT Panels, LT Feeder pillar boxes, LT bus bar chambers internaly and externaly with one coat of superior quality smoke grey paint to achieve fine finishing complete all as specified and directed by Engr - in charge at site.
Dismantling of old unserviceable doors, back sheets, side sheet of LT panels, bus bar chamber or feeder pillar box installed at various places by cutting/descrewing after making the system disconnected from Elect supply and M&L for fabrication of doors/frames/ partition, bottom sheet by bending hot or cold, making holes, notching, welding of MS black sheet for LT panel board, bus bar chamber, feeder pillar box made out of 2 mm thick mild steel sheet including providing hinges for opening or closing of door, making handles, locking arrangement and painting of sheet both side with superior quality smoke grey paint after applying a coat of red oxide and matching with the existing ( Complete LT apnel/ Bus bar chamber shall be painted ) complete all as specified and directed by the Engineer - in-Charge at site. Note:- 1. The cost of disconnecting of LT cable and earth strip and reconnecting the same after repair work shall be deemed to be inclussive in the unit quoted rates. 2. Painting of complete LT Pannel/Bus bar chamber shall be carried out , nothing shall be payable extra in this regard.
Supply and fixing in replacement , street/security light bracket made out of 40 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete.(Rates quoted by the contractor shall deemed to include for nut and bolts).
M&L for attending major breakdowns by providing 01 line man, one helper and one Camper Vehicle in serviceable condition on LT/HT lines, LT/HT cables, LT Panels, DBs, VCBs, RMUs, four pole, two pole, transformers etc including clearing of lines, trimming of tree branches, replacement of insulators/conducotrs/ cross arms & removal of tree branches from LT/HT lines and laying of temporary cables etc complete all as directed at site by Engineer-in-Charge. Note:- 1. Items used will be measured & paid seperately under rlevent item of sch A. Contractor has to arrange suitable vehicle with manpower as abopve and T&P on short notice as & when required on the direction of Enginee-in-Charge.The contractor will immediately depute complete set of arrangements as above on receipt of information to atten the electric breakdown, failing which the contractor should face penalty at the rate of 1% of work done amount of the CA.
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 250 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom with angle iron legs 04 Nos of size 75x75x6mm of length 0.90 mtr and embbded in PCC. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings : CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables. INCOMING :- MCCB 160 Amps, 4 pole, 415 volts, 25 kA, 50 Hz, , thermal magnetic release, adjustable type 70% to 100% -01 Nos OUTGOING :-(a) MCCB 100 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release, Adjustable type 70 % to 100% - 02 Nos (b) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos (c) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos (d) Current transformer (CT) of rating 400/5, tape wound, rated burden 5 VA - 03 Nos (e) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (f) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (g) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos.(h) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (j) Danger Notice Plate -02 Nos (k) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 1.0 Sqm front area) Note:- Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engineer-in-Charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will prepared as per instructions of manufacturer and rate of fondation shall be deemed to be included in the quoted rates.
Supply & fix in replacement copper strip 20mm x 3 mm buried in ground/ fixed on wall/ Passed through pipe/wall incuding connected by means of exothermic brazing, nuts and bolts where required complete all as specified and directed.
Supply & fix in replacement galvaniased iron (GI) strip 32mm x 6 mm buried in ground/ fixed on wall/ Passed through pipe/wall incuding connected by means of exothermic brazing, nuts and bolts where required complete all as specified and directed.
M&L for GI Tubes in replacement of 32mm bore size, light grade ,galvanised including fittings , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road for protection of LT cables or earth strips etc complete all as specified and as directed.
M&L in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specifed and directed.
M/s Shree Construction Company
star electricals
GITANSH ENGINEERS AND COMPANY
NAGEL ENTERPRISES
M/s Yash Electrical and Maintenance
new india engineers
SHRI HARI CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .