| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC Negotiation |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
6 Jun 2022, 6:00 pmClosed
ACE I RHB
Additional Chief Engineer I Rajasthan Housing Board Jyoti Nagar Jaipur
Water supply Sewerage and Rain water harvesting system for multistoried flats G PLUS 12 504 Nos EWS and G plus 12 208 Nos LIG flats under CMJAY Scheme at sector 03 Pratap Nagar Sanganer Jaipur including One years O and M work
2022_RHBCE_275405_3
ACE-I_03/2022-23
Open Tender
Civil Works
Percentage
270 days
Jaipur
As per NIT
3 documents required · 3 mandatory
₹3,540
As per NIT
₹2.4 L
Yes
29 Dec 2023
18 May 2022
9 Jun 2022
18 May 2022
6 Jun 2022
18 May 2022
Amount
Rain water chamber 450 x 450 mm
Rain water chamber 600 x 600 mm
Rain water chamber 750 x 600 mm
Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.
d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately
Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE2,3 & 4 (PHED BSR 3.4.1)
Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect.
Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard.The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee
Construction of RR stone masonry sluice valve chambers of following size wall thickness 45CM bed concrete M-15 grade 15 CM, 25 CM thick internal & outer planter ferrow cement cover "AA" class loading. Internal size 1.20 x 1.50 Mtr.
Constructing providing and fixing of pre-cast RCC M-40 grade circular Road Side Inspection Chamber including earthwork using sulphate resistant cement with following dia and depth cylindrical piece with 100mm wall thickness, 100mm base slab, inbuilt cover & frame on top, provision for 110mm OD in and out sewer connection with making proper in built benching and channel with PCC M-15 grade including providing cast-in-situ 100mm thick foundation of PCC M-10 grade, supplying and fixing circular precast SFRC Circular 300 mm dia manhole cover with frame - M.D. - 10, including steel reinforcement minimum @ 80kg/cum, testing for water tightness complete in all respect as per drawing, specification and the direction of the Engineer. Pre-cast Road side inspection chamber of 450mm dia (internal), 600mm depth and 750mm dia base foundation
Supply,Testing, commissioning of Hydropneumatic Pressure Boosting System consisting of 3 Nos. Vertical Inline Multistage centrifugal pumps with TEFC IE2 class motor, Pump connected in Parallel mounted on a common MS ISMC type base frame with Suction & Discharge manifolds of Galvanised MS Pipe, One No. NRV & Two Isolating Valves for each pump, Pressure Gauge, Pressue Transmitter & minimum IP54 type Panel. The Panel shall include all required fuses, motor protection, main switch, 3 Nos. VFDs, KIRLOSMART (iOT Remote Monitoring System, IP20,) BMS Connectivity through RS485 PORT, all automation operations etc. complete in all respect & 1-Nos 200 Ltrs MS 10 bar Pressure Tank. This work including Pressure transmitter, flow meter, NRV on discharge line as per required line size and Butterfly valve, Y-Strainer on suction line and all accessories for pump and system safe operation complete job as per direction engineer in charge
For OHT FILLING (LIG & EWS)
The Technical details of the system are as under :
PUMPS - 3 Nos. (2W+ 1S)
Head pump - 75-85 Mtrs.
Flow each pump - 22-28 M3/Hr.
VDF make - Danfoss/VACON - 3 nos.
Impeller : SS 304
Shaft : SS 316
Casing ; SS 304
CI Suction-dischage port of pump
Makes: Kirloskar, Grundfos, Armstrong.
Solenoid Valve with 12V, DC Operated control Panel and float switch
Size - 50mm
MOC - SS 304
Valve Body - CF8M
Make :- U-Flow, Danfoss
Provision for O&M of scheme including T&P, reparing of pipe line with material and reparing of motor pump, complete in all respect for one year
Bidder Name
Amount
P M Construction Company(GSTN-08ABIPY8298F1ZR)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .