Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹71.7 LAccepted-AOC SHOP NO 6 BENGALI CLUB MIDDLE POINT SRI VIJAYA PURAM 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | 1 | Accepted-AOC Being Lowest Bidder | |
| 2 | 2₹88.0 L+₹16.3 L (22.8%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | 2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | 3₹93.6 L+₹22.0 L (30.7%)Rejected-Finance 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | 3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | 4₹97.4 L+₹25.8 L (36.0%)Rejected-Finance 1 PROP A R ELECTRICALS SCHOOL LINE MINNIE BAY JUNCTION PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | 4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | 5₹1.1 Cr+₹38.3 L (53.4%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | 5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
20 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Pankaj Vyas, IDSE, Commander Works Engineer N
Commander Works Engineers No. 2, Brichgunj, Port Blair - 744 103
Provision of HT 11 KV, 2 MVA Automatic Voltage Regulator on Main Receiving Station, Connected Works at Brichgunj Military Station, Port Blair
2023_MES_592525_1
80285 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Port Blair
Class C
Category b ii
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Brichgunj
₹1.6 L
Yes
20 Jul 2023
1 May 2023
27 Jun 2023
1 May 2023
20 Jun 2023
22 May 2023
1 May 2023 - 8 May 2023
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in Hard / Dense Soil for laying Pipes / Cables etc. complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
Supply and laying of DWC [Double Wall Corrugated] HDPE Pipe and including fittings such as couplers, bends, end caps etc., ISI marked of outer dia of 120mm and inner dia 103mm Polyethylene with smooth internal and profiled external surface for non pressure under ground cable complete all as specified.
Supplying, laying and testing HT UG Cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 11000 Volts grade [Heavy Duty] suitable for Earthed System with aluminium conductor of size 3 Core, 185 Sq.mm conforming to IS – 7098 [Part – II] laid in trenches, fixed to walls or passing through pipes and connecting up complete all as specified and as directed.
M & L for Cable End Termination Joint, Heat Shrinkable type, Outdoor type, suitable for 11 kV Grade, 3 Core, 185 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing including dismantling old cable joint of any description complete all as specified and as directed.
M & L for Cable End Termination Joint, Heat Shrinkable type, Indoor type, suitable for 11 kV Grade, 3 Core, 185 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing including dismantling old cable joint of any description complete all as specified and as directed.
Supplying and laying GI pipe, 150mm dia, Light Grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of Factory Made, Outdoor type, Floor mounted 12 KV, 3 Phase, 3 Wire, 50 Hz, 630 Amps, Short Time Current Rating of 21 kA for 3 Seconds, SF6 Insulated, 3 Way RMU [Ring Main Unit] [Manual Compact Switchgear] Comprising of 02 Nos of 11 kV, 630 Amps, SF6 Insulated Load Break Switches [Outgoing], Rated Power Frequency Withstand Voltage of 32 kV, rated Lighting Impulse Withstand Voltage of 85 kVp with Fault Passage Indicator System [FPIS] and Voltage Presence Indicating Systems [VPIS] etc. and 01 Nos, 12 kV, 630 Amps, SF6 Insulated VCB [Incoming] Rated Power Frequency Withstand Voltage of 32kV, rated Lighting Impulse Withstand Voltage of 85 kVp with Self-Powered Numerical Protection Relay for Short Circuit, Over Current and Earth Fault, Low energy release series Trip Coil for VCB Tripping Circuit, Low Voltage Ring type CT: 100-50/1A, Class 5P10, 2.5VA for each Phase, Shunt Trip Circuit for external Trip Signal, all Mechanical Interlocks, and Voltage Presence Indicating Systems [VPIS] etc. suitable for installations in 12 kV, 3 Phase, 3 Wire, 50 Hz effectively earthed system, including independent manual charged spring mechanism and fully rated earth switch with provision for earth and testing of cable including Air Insulated Cable Boxes with gland plates suitable for bottom entry 3 Core, XLPE, 11 kV, underground cable up to 120 Sq.mm with provision for earthing of cable including set of hooks for lifting during installation complete all as specified and as directed and shall comprise of the following: Make: BHEL / ABB / Siemens / Andrew Yule / Schneider / Crompton Greaves / Alsthom / L & T
RMU shall be 11 KV, 630 Amps, 21 kA for 3 Seconds, SF6 Insulated, Manual / Motorised, Outdoor, 3 Way, Both side Extensible with Air Insulated Bus Connected Metering unit, Type tested in line with latest IEC Standards, suitable for operations near coastal area and at 40ºC Ambient Temperature without any de-rating, Switchgear and Busbar shall all be contained in a Stainless Steel Enclosure [Minimum 2mm thick AISI 441 Grade] filled with SF6 at 0.3 Bar [300 hPa] Relative Pressure, RMU Tank shall provide Full Insulation and Switchgear shall be insensitive to the environment with Degree of Protection of IP67, Switchgear Operating Mechanism shall have an IP2X Protection and Cable Chamber shall have IP3X Protection, Outer Enclosure shall be IP 54 type tested, Powder Coated with Pure Polyester Based Paint, suitable for the site installation conditions, Accidental Overpressure due to an Internal Arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator, Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars. Extension of cubicle shall require 450mm to handle and the gap between the coupled RMU’s must be within 10mm. Ring Main Unit shall comprise of the following:
[A] Load Break Switches, each comprising of the following: [i] 11 kV, 630 Amps, 21 kA / 3 Seconds, 3 Pole, Manual, Load Break Switch, Short Time Current [STC] 21 KA for 3 Sec, Rated Power Frequency Withstand Voltage of 32 KV, Rated Lightning Impulse Withstand Voltage 85 KVp, FPIS & VPIS, Mechanical Interlock etc. as per IEC 62271-100/102/200 – 1 Nos [ii] Multi Function Meter [MFM] – 1 Nos [iii] Counter – 1 Nos [iv] Fault Passage Indicator [FPI] with Current Sensors [CBCT] for Earth Fault – 1 Nos
[B] Vacuum Circuit Breaker [VCB], comprising of the following: [i] 11 KV, 630 Amps, 21 kA / 3 Sec, 3 Pole VCB with Manual / Motorised Spring Assisted Mechanism and Series Trip Coil with 3 Pole Manual Disconnector, 3 Pole Manual Earth Switch, Low energy Trip Coil, Mechanical Emergency Push Button & Counter– 1 Nos [ii] Built-In Earth Switch – 2 Nos [iii] Position Indicator through clear front mimic in line with IEC 62271-103 – 1 Nos [iv] Self Powered Relay with O/C, S/C, E/F Protection – 1 Nos [v] CT Ratio 200-100/1-1A for Incoming, 100-50/1-1A for Outgoing and, Class - 1.0, 2.5VA for Metering and Class 10P10, 2.5 VA for Protection – 1 Set [vi] Live Cable Indicator with indication at the Front and Three Inlets to check the Synchronization of Phases – 1 Nos [vii] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 120 Sq.mm, XLPE Cable – 1 Set [viii] Cable Termination Cover Boots [Push on type] – 1 Set [ix] Fault Passage Indicator [FPI]. [x] Circuit Breakers shall have Two Positions: Open or Disconnected and Closed. A separate and independent 3 Position Earthing Switch and disconnector shall be fitted to open and earth the cables in such way that interlocks prevent all unauthorised operations. An operating mechanism shall be used to manually close the circuit breaker and charge the mechanism in a single movement. An independent mechanism shall be fitted for the 3 Positions Earthing Switch and Disconnector Circuit breaker shall be fitted with a local system for manual tripping by an Integrated Push Button. There shall be no automatic reclosing. Circuit Breaker shall have a min of 2000 Mechanical and Electrical Operations and 50 Nos Short Circuit Operations, Disconnector and Earth Switch shall have a minimum of 1000 [M1] Mechanical Operations, 100 Electrical Operations at rated current and 5 Nos Operations at Rated Short Circuit Current.
Notes: [a] An operator situated in front, lateral and rear [A-FLR 21kA – 1 Sec, Downwards Exhaust, for Tank as well as Cable Compartment] of the RMU Switchboard during an internal fault shall not be exposed to the effects of Arcing. Internal Arc Type Test Report for IAC AFLR 21 kA for 1 Sec for both Tank & Cable Box shall be for minimum 3 Way / 3 Function RMU. [b] All operations shall be from front of the RMU, including access to cable bushings. Bushings along the sides or the rear of the RMU are not acceptable. [c] The rate quoted is also deemed to be including the cost of connection of HT Cables up to 3 Core, 120 Sq.mm from 2 Pole / 4 Pole Structures, removing of cable loop and reconnection to RMU complete all as specified and as directed. [d] End termination joints shall be measured and paid separately. [e] CONSTRUCTION OF PLINTH / FOUNDATION FOR 11 kV RMU: The rate quoted is deemed to be including the cost of Plinth / Foundation complete all as per manufacturer’s recommendations, drawings, as specified and as directed. Nothing shall be paid extra on this account.
Supply, Installation, Testing and Commissioning of Automatic Voltage Regulator, 11 KV, 3 Phase, 50 Hz, Oil Cooled [ONAN], Outdoor type, suitable for Balanced Supply and Unbalanced Load, designed for input variation between 9000 Volts to 12000 Volts with Output Voltage stabilized at 11000 Volts with accuracy of ± 1 % and of Capacity 2000 KVA, conforming to IS – 2026, speed of correction not less than 1 KV per Second, including first filling of Transformer Oil conforming to IS – 335, complete and comprising / compliance with the following Technical Specifications, including PCC Foundation as per the OEM recommendations, complete all as specified and as directed: [Make: Andrew Yule / Brentford / APLAB / ABB / Siemens / Schneider / Crompton Greaves / Alsthom / L & T] [A] Copper Wound Transformer: Double Wound. [B] On Load Stepless Voltage Regulators having "Carbon Roller Assembly": Copper Auto Wound and Delta connected. [C] Buck and Boost Transformer: Double Copper Wound, Open / Open Connected [D] Automatic Control Gear consisting of: One Electronic Voltage Relay, One Reversing Geared Motor Unit, Two Limits Switches in order to avoid over running highest and lowest positions and Chain Drive, Coupling Device and all electrical connections.
[E] Construction Feature: Oil Immersed, Naturally Cooled, On Load, Stepless Rolling Contact Automatic Voltage Controller. [F] Mode of Operation: [i] Manual [ii] Motorized [iii] Automatic [G] Service: Outdoor. [H] Out Put: Stabilized at 11000 V ±1%, 3 Phase, 50 Hz suitable for balanced/un balanced load. [I] Equipment consists of: [i] Step Down/Step Up unit [ii] Regular Unit [iii] Buck/Boost Unit [iv] Automatic Control Unit [v] 'E' Reversing "Q" Panel if required' [J] Terminals: Input & Out Put: Bare Bushing with Terminal Cable End Box suitable for entry of HT 11 KV Grade Cable of size up to 240 Sq.mm, 3 Core. [K] Temperature Rise: 50°C Rise of top oil over an ambient of 50°C. [L] Tank and Oil: All the units shall be housed inside the sheet steel tank. The number of tanks will depend on design parameter. Items shall be supplied with first filling of Oil confirming to IS – 335.
[M] Fittings and Accessories: Accessories for its successful operation including the following major items as Per the requirement: [i] Rating Plate, Roller, Plain Oil Level Gauge and Conservator [ii] Drain Valve, Filter Valve, Sampling Valve with Plug & Earthing Terminals [iii] Inspection Cover, Thermometer Pocket & Lifting Lugs [iv] Silica Gel Breather & Buchholz Relay with Shut Off Valve [v] Pressed Steel Radiators with Shut Off Valve [vi] Explosion Vent, OTI & WTI with Alarm Trip Contacts [vii] Suitable 11 KV/110 Volt PTs on 11 KV input and output side of AVR to measure 11 KV voltage and relay sensing [01 Set of Three] [viii] Marshalling Box [ix] Sensing Relay [x] Servo Step Sync with Reverse Geared Motor of suitable capacity [xi] Voltmeter for Three Phase Input & Output Voltage measurement with Rotary Switch. [xii] Limit Switches to avoid over running highest and lowest positions.
[N] Control and Monitoring Features: The Control and Monitoring System of HT Automatic Voltage Regulator shall have the Following Standard Features: [i] Voltmeter for Output Voltage with VSS. [ii] Auto/Manual Switch To change From Automatic to Manual Voltage Correction Action [iii] Automatic Control Gear with Solid State Card and Male Female Connectors [iv] Solid State Relay to sense Variations of more than + 1% of the rated Output Voltage [v] Servo Motor 60 RPM 10 Kg/cm AC Synchronous Reversing Geared Motor Unit. [vi] Two Limit Switches to avoid over running highest and lowest positions. [vii] Chain Drive Coupling Devices and all electrical connections. [h] Terminal Arrangement: Cable Box suitable for Input & Output armoured cables of appropriate rating. Auxiliary connection Suitable for 1.1 KV Grade Cable.
Prasur Electricals & Engineering Co.
Hindustan Traders
A. R. ELECTRICALS
Vardhman Airport Solutions Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .