SITC of VRV Type AC
9380807
GEM/2026/B/7586099
Two Packet Bid
14 HP Air Cooled Outdoor Condensing Unit Supply,20 HP Air Cooled Outdoor Condensing Unit Supply,24
Mumbai, Maharashtra
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
3 yrs
₹49 L
80%
Board, Chief Mechanical Engineer, NA, Mumbai Port Trust, Ministry of Ports, Shipping and Waterways, (The Board Of Mumbai Port Authority)
₹4.5 L
26 May 2026
26 May 2026
25 Jun 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) | Spec |
|---|---|---|---|---|---|---|---|
| 1 | 14 HP Air Cooled Outdoor Condensing Unit Supply | Supply and delivery of 14 HP air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel PCB cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 Pascal static pressure | 6 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 | |
| 2 | 20 HP Air Cooled Outdoor Condensing Unit Supply | Supply and delivery of 20 HP air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel PCB cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 Pascal static pressure | 3 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 | - |
| 3 | 24 HP Air Cooled Outdoor Condensing Unit Supply | Supply and delivery of 24 HP air cooled outdoor condensing unit with inverter scroll compressor condenser coil high static fan microprocessor control panel PCB cooling feature auto bypass for centralized control suitable for 55 degree ambient and 82 Pascal static pressure | 1 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 | |
| 4 | 14 HP Outdoor Unit Installation Testing Commissioning | Installation testing and commissioning of 14 HP air cooled VRF outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required | 6 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 | - |
| 5 | 20 HP Outdoor Unit Installation Testing Commissioning | Installation testing and commissioning of 20 HP air cooled VRF outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required | 3 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 | |
| 6 | 24 HP Outdoor Unit Installation Testing Commissioning | Installation testing and commissioning of 24 HP air cooled VRF outdoor condensing unit including all necessary connections refrigerant piping nitrogen pressure testing vacuumization electrical termination trial run and commissioning complete as required | 1 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 | - |
| 7 | 1.5 TR 4 Way Cassette Indoor Unit Supply | Supply of 1.5 TR VRF 4 way cassette indoor unit with cooling capacity 12 kW and above power input 110 to 125 W airflow 1800 to 2000 cubic metres per hour noise level less than 35 dB at low speed with mandatory auto bypass feature | 10 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 | |
| 8 | 4 TR 4 Way Cassette Indoor Unit Supply | Supply of 4 TR VRF 4 way cassette indoor unit with adequate cooling capacity power input airflow 1800 to 2000 cubic metres per hour noise level less than 35 dB at low speed with mandatory auto bypass feature as per specifications | 29 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 | |
| 9 | 1.5 TR 4 Way Cassette Indoor Unit Installation | Installation testing and commissioning of 1.5 TR VRF 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required | 10 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 | |
| 10 | 4 TR 4 Way Cassette Indoor Unit Installation | Installation testing and commissioning of 4 TR VRF 4 way cassette indoor unit including mounting electrical termination control wiring drain piping connection trial run and commissioning complete as required | 29 | No | Saurabh Kumar 400001,Sustainability House 2 nd Floor Dr.S.B.Road (Old Goa Street)Near Railway Manager Building Ballard Estate Fort Mumbai | 180 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9380807.pdf
GEM_BID • 0.43 MB
spec_2026-05-26-12-00-40_4861a48a906d41cb264a3d317a8a0255.pdf
BOQ • 1.34 MB
boq_filled_2026-05-26-12-00-40_cfe0c2a402ae3f5831073875a982d4e7.csv
BOQ • 0.02 MB
1779781920.xlsx
GEM_OTHER • 0.02 MB
TD102026_d02660e2-0926-45c0-99831779782319218_sk.jhinai@mumbaiport.gov.in.pdf
GEM_OTHER • 1.97 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid