Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-Finance | L1 | Accepted-Finance LOWEST RATE QUOTED | |
| 2 | L2₹39.8 L+₹1.6 L (4.24%)Rejected-Finance | L2 | Rejected-Finance HIGHER RATE QUOTED THAN L1 | |
| 3 | L3₹40.6 L+₹2.4 L (6.38%)Rejected-Finance | L3 | Rejected-Finance HIGHER RATE QUOTED THAN L1 | |
| 4 | L3₹42.3 L+₹4.1 L (10.8%)Rejected-Finance | L3 | Rejected-Finance HIGHER RATE QUOTED THAN L1 | |
| 5 | L4₹42.7 L+₹4.5 L (11.9%)Rejected-Finance PO PS BUD BUD DISTT PURBA BURDWAN PIN 713403 | BUD BUD | PURBA BURDWAN | WEST BENGAL | 713403 | L4 | Rejected-Finance HIGHER RATE QUOTED THAN L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
18 Jul 2024, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2024_MES_664738_1
8500-131/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
As per NIT
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹80,000
Yes
2 Sept 2024
8 Jul 2024
19 Jul 2024
8 Jul 2024
18 Jul 2024
13 Jul 2024
Amount
Demolition for brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, facings, dressed stonework and precast concrete articles and removal or rubbish off the site complete all as specified and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed
M&L for brickwork with flyash bricks, straight or curved on plan exc 6m mean radius, half bricks thick built in CM (1:4) complete all as specified and directed
M&L for extra for forming fair finish drain channel upto 30 cm inner grith in cement concrete using extra cement complete all as specified and directed
M&L for extra for forming fair finish drain channel inner girth exc 30 cm but n.exc 45 cm in girth in cement concrete using extra cement complete all as specified and directed
M&L for cement concrete type B-2, 1:2:4 (using 40 mm graded stone aggregate) in surface channels and drains for benching complete all as specified and directed all as specified.
Demolition of concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removal of rubbish off the site complete all as specified and directed
M&L for cement concrete type C-1 1:3:6 (using 20mm graded stone aggregate) in cills, steps, plinth courses, string courses, lacing courses, parapets, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed rounded or chamfered on edges complete all as specified and directed
M&L for PCC in foundation filling and mass concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) complete all as specified and directed
Dismantling post (Wood/Steel or RCC) any section including taking out embedded portion and making good disturbed portion complete all as specified and directed
Excavation in post holes (or similar holes) each n.exc 0.5 cum getting out, returning filling in and ramming earth and removing surplus soil to a distance n.exc 50 m and making good surface in soft/loose soil complete all as specified and directed.
S&F mild steel posts and struts in fencing including cutting top to shape as directed, drilling holes, notching for wire,etc , flat iron fillets ( for securing wire mesh etc.) top section fixed including all necessary drilling,bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate), in foundations, filling and mass concrete complete all as specified and directed
Demolition of reinforced Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed
M&L for RCC M-25 (Design Mix) using 20mm graded aggregate as in foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L for M-25 (Design Mix) using 20mm graded stone aggregate Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for M-25 (Design Mix) using 20mm graded stone aggregate Columns, pillars, piers, posts and struts complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface of concrete complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping including use and removal of necessary formwork complete all as specified and directed.
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed.
S&F Mild steel bars 6 to 8mm dia as in stirrups cut to length, stirrups, spacers and binders required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed.
M&L for Providing precast cement concrete type B-0 1:2:4 with (using 12.5 mm graded aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame, set in CM (1:4) complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing (FE 410-W-Gde-250A) complete all as specified and directed.
S&F framed work such as grills, gratings,etc,with ends of bars shouldered and /or riveted, or forged into spickes; framed guard bars; barried iron door;ladders;framed balustars; walk ways; railings; framed work of water tank and similar work conforming to Fe 290 Gde-E--165 complete all as specified and directed
S&F mild steel for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410- W(Gde- E-250) quality-B complete all as specified and directed
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4 ) and finish smooth & even with using extra cement complete all as specified and directed
M&L for preparation of new plastered surface of wall applying of two coats of coat of white wash complete all as specified and directed
M&L for two coats of synthetic enamel paint on new surface over one coat of red oxide primer including preparation of surface of any description, over 10 cm in width or girth not other wise described all as specified and directed by Engr-in-Charge.
Dismantling fencing wire mesh any type complete all as apecified and directed by Engr- in-Charge
S&F Galvanised iron wire using Hot Dip technology chain electrogalvanised coating chain link fencing wire mesh of size 75mm x 75mm minimum dia meter of wire 3mm conforming to IS -2712-2003 having tensile strength 400 to 500 Mpa . The mesh wire and line wire fabric shall be manufactured from ISI marked (make TATA wireson) galvanised stell conforming to IS -280 :2006(4th revision) the Kuncled ends should be of atleast 50% of the sixe of the square mesh.The wires used in fencing should be long lasting and resistance to corrosion and testing criteria fullfill the requirement as per IS 1161:1998 complete all as specified and as directed.
M&L for MS Conceretina Coil over boundry wall circle of coil Max 600mm and spacing of bars not exc 75mm, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs galvanised 2 strand, steel barbed wire 2.24 mm dia, barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with provision of galvanised mild steel wire, stapples or steel pin etc. as directed complete all as specified and directed (each line to be measured).
S&F mild steel screw bolts (machine made)with hexagonal or square heads at one end and screw other .and each screw end to be fixed with washers and nut exc 5 cm but n.exc 10 cm long complete all as specified and directed
M&L for two coats of synthetic enamel paint on new surface over one coat of red oxide primer including preparation of surface of any description, n.exc 10 cm in width or girth not other wise described all as specified and directed by Engr-in-Charge.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing to low lying area and rubbish off the premises complete all as specified and directed.
M&L for 20mm for Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including screed bed 20mm thick CM 1:6 complete all as specified and directed.
M&L for 100 mm thick cement concrete Type D2, 1:4:8 (using 40 mm graded stone aggregate) as in sub bases complete all as specified and directed
M&L for 75 mm thick cement concrete type B1 ,for PCC (1:3:6) using 40 mm graded aggregate used as in sub base, sub floor/pavings and finishing cement concrete surface without using extra cement complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed.
M&L for 25 mm thick chequered cement concrete tiles of approved size,set, jointed and pointed using with grey cement and pigment in floors, pavings etc including the setting and jointing in neat cement plaster or slurry 0.3 kg/sqm over 20mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
Excavation in trenches, n.exc 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick with soft/loose soil complete all as specified and directed.
Removing Excavated soils exceeding 250 M but not exceeding 500 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
M&L for out door vitrified parking tile of size 60 x 60 cmx 10 mm thick tiles of approved size, set, jointed and pointed using with grey cement and pigment in floors, pavings etc including the setting and jointing in neat cement plaster or slurry 0.3 kg/sqm over 20mm thick screed bed or bedding layer in cement mortar (1:6) complete all as per specification.complete all as specified and directed.
M&L for aluminium paint on old rusted chain link fencing complete all as specified and directed.
M/S TILKU ENTERPRISE (BID ID -3061890)
M/s. Kalpana Construction (BID ID -3064263)
M/S BHATTACHARJEE ENTERPRISE (BID ID -3061952)
KAZI SAHABUL ALAM (BID ID -3062300)
M/S Konar Engineering (BID ID -3063986)
M/S BISWAS AND KUNDU CONSTRUCTION (BID ID -3064017)
S.P.S. SUPPLIERS (BID ID -3064050)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .