Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance HOUSE NO 1777 NEAR ARCHANA APARTMENT MUL ROAD UTTAMA NAGAR CHANDRAPUR 442401 MS | CHANDRAPUR | CHANDRAPUR | MAHARASHTRA | 442401 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹20.6 L
EMD Value
₹25,780
Closing Date
5 Sept 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer EnM, Ballarpur Area
Office of Area General Manager,EnM Department, WCL Ballarpur Area
Different type of EnM worksto be carried out as and when required at Ballarpur OpenCast Mine, Under Ballarpur Sub Area
2022_WCL_254046_1
ba3650-enm-034-2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Office of Area General Manager, EnM Department, WCL
Please refer Tender documents.
6 documents required · 6 mandatory
₹25,780
Yes
6 Sept 2022
22 Aug 2022
6 Sept 2022
22 Aug 2022
5 Sept 2022
22 Aug 2022
22 Aug 2022 - 26 Aug 2022
180 days
Amount
Loading and unloading HT/LT pump set from various locations to the field
On bed alignment with installation pontoon pumps sets, fitting of bolts jointing of suction pipes, foot valve, bends, delivery pipes, NR valve, sluice valve, cable pieces, cable supporting and cable supporting etc
Shifting of lighting transformer, switches, starters, OCBs, isolators etc. Loading / unloading and shifting and installation placement manually/ crane
Shifting of PVC cable of 3.3kV grade 50/70/95 sq.mm
Loading, unloading, transportation of MS angles, channels, GI sheets to the site, pit digging erection of channels making structure and fixing GI sheets
Shifting of MS fabricated lighting towers includes disconnection, dismantling of the light fitting and control switches from the tower, pit digging taking out the same tot the required site, pit digging, erecting the tower, fixing the light fitting HPSV industrial type and arranging for the connection
Shifting of armoured lighting cable 1.1kV 2/4/6 sq.mm in field including loading and unloading, transportation to the site by departmental truck, handling, shifting on the site and arranging for connection with proper supports
Taking out of pump sets including dismantling of the suction pipes, bends, foot valves, delivery pipe pieces, bends sluice valve and non return valve etc. Disconnection and removal of the cable pieces, transportation to the safe prepared site in the field
Dismantling pump body taking out the failed runner assembly and replacing with repaired assembly with coupling, transportation of the failed runner assembly to workshop for repairing
Pump suction extension/ reduction/ dismantling of 8” dia suction pipe, taking out foot valve, cleaning/ repairing alignment and refitting
Dismantling and fitting of 8” dia flexible hose pipe including dismantling of pipes shifting, handling and laying and fixing of empty barrel (Floating arrangement with proper alignment and support) and complete the delivery pipe line in the sump
Dismantling and shifting of 8” pipe line at various locations in the mine
Loading and unloading and transportation of 8” MS pipe to the working site with the departmental truck
Spreading, laying and jointing of 8” MS pipe including inserting of rubber/belt joints with suitable nut and bolts etc
Shifting of HDPI pipe including, dismantling, laying and water tight joint with proper alignment and support
Loading/unloading, transporting of MS girder, poles 10/12 mtrs long to the site by departmental truck, handling, shifting at that site to and fro
Collecting of old & used pontoons from field to repair site or AWS and loading, unloading, transportation from the repair site/ to pumping site
Shifting, lowering, assembling fabricated new pontoons in the sump
Fabrication of walkway pontoons
Transportation of pantoon from the repair site and installation in the sumps
Dismantling, loading, unloading and transportation of old and used pontoons from sumps
Removal of baby pontoons from sumps
Erecting rolled steel joist (girder) pole 200 x 100 mm. (25.9 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ (CSR 8-1-10)
Erection of departmentally provided rolled steel joist (girder) pole 100 x 116 mm (23kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ(CSR 8-1-12)
Erecting MS pole bracket for LT OH conductor fabricated from 65x65x6 mm section, 1100 mm long for necessary nos. of provided insulators and erecting on pole with 50x6 mm clamp as per approved method of construction and complete as per specification no. OH-PL/BKT (CSR 8-4-6)
Erecting vee cross arm with ISM channel of 75x40x6mm, for 11kV HTOH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220 mm bent at angle of 60 degree keeping base 305 mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts,washers complete as per specification no. OH-PL/VCA (csr 8-4-12)
Erecting bracket for guarding of HT OH Line, made from channel iron 1600 mm in length and 65 x 65 x 6mm thick erected on pole as per specification no. OH-PL/VCA (8-4-16)
Erecting 100 x 50x6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4m wide DP structure and erecting on DP with 50x6 mm clamp as per approved method of construction and complete as per specification no. OH-PL/BKT. (CSR 8-4-11)
Erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394 kg/km) as per specification no. OHCON/ ACSR ( CSR 8-5-11)
Erecting ACSR conductor of size 6/1-3.66 mm complete.(Mink) (255 kg/km) as per specification no. OHCON/ ACSR (CSR 8-5-9)
Erecting ISI mark G.I. pipe pole „B‟ grade 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP (CSR 8-1-16)
Erecting MS pole bracket for guarding/LT OH Line fabricated from ISM channel 75x40x6mm and 1100 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp as per approved method of construction and complete as per specification no. OH-PL/BKT (8-4-4)
Erecting porcelain disc type insulator with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI (8-6-6)
Erecting porcelain shackle type LT medium insulator 75x115 mm dia. with G.I. (Shackle) strips , nuts and bolts, complete. (8-6-2)
Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level (8-8-1)
Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. (8-8-3)
Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level (8-8-2)
Erecting porcelain pin type insulator with G.I. pin suitable for 11kV line, complete as per specification no. OHINS/ PN (8-6-9)
Erecting departmentally supplied LED street light/ flood lightFitting upto 400W (2-5-29)
Total impact of GST for the purpose of CTC
M S R MURTHY
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .