Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹33.7 L+₹29,150 (0.87%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹36.5 L+₹3.1 L (9.31%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹38.3 L+₹4.9 L (14.7%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹40.7 L+₹7.3 L (21.9%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | m/s anil traders L3 | anand enterprises L1 | M/S Amit Traders L9 | Kumar Sales Corporation L5 | M/s Shanti Enterprises L8 | Om Electricals L4 | M/s Anupam Construction Co. L6 | SHRI RAM CONSTRUCTION L7 | JAI SHITLA CONSTRUCTION COMPANY L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M/L for Maintenance and servicing of standby DG Set complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleaner , change air cleaner elements, check coolant level & make up the same ,drain the fuel filter & water separator ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, including M&L for changing of V-belts, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load and record shall be made in respect of RPM , oil pressure , oil temperature, coolant temperature, frequency , load current , battery charging , fuel consumption etc complete all as specified and directed by Engineer in Charge for 380 KVA DG set.
Make - Cummins with AMF Panel. | 1 | Each Job | 4,000 ₹4,000 | 5,000 ₹5,000 | 7,000 ₹7,000 | 2,200 ₹2,200 Lowest | 7,000 ₹7,000 | 3,500 ₹3,500 | 6,500 ₹6,500 | 4,000 ₹4,000 | 6,000 ₹6,000 |
| 2.00 | All as per Item No . 1 here-in -before but for : 320 KVA DG set .
Make:- `Kirloskar with AMF panel | 1 | Each Job | 4,000 ₹4,000 | 4,500 ₹4,500 | 7,000 ₹7,000 | 1,800 ₹1,800 Lowest | 6,000 ₹6,000 | 3,000 ₹3,000 | 6,000 ₹6,000 | 4,000 ₹4,000 | 5,000 ₹5,000 |
| 3.00 | All as per Item No . 1 here-in -before but for : 250 KVA DG set .
Make:- `Cummins with AMF panel | 3 | Each Job | 3,000 ₹9,000 | 4,000 ₹12,000 | 7,000 ₹21,000 | 1,500 ₹4,500 Lowest | 5,800 ₹17,400 | 2,500 ₹7,500 | 5,000 ₹15,000 | 3,500 ₹10,500 | 4,000 ₹12,000 |
| 4.00 | All as per Item No . 1 here-in -before but for : 200 KVA DG set.
Make:- Cummins/Kirloskar/Greaves cottan with AMF panel | 4 | Each Job | 3,000 ₹12,000 | 3,800 ₹15,200 | 7,000 ₹28,000 | 1,500 ₹6,000 Lowest | 5,700 ₹22,800 | 2,000 ₹8,000 | 5,000 ₹20,000 | 3,500 ₹14,000 | 3,500 ₹14,000 |
| 5.00 | All as per Item No . 1 here-in -before but for : 125 KVA DG set .
Make:- `Kirloskar / Cummins with AMF panel | 5 | Each Job | 3,000 ₹15,000 | 3,500 ₹17,500 | 6,000 ₹30,000 | 1,500 ₹7,500 Lowest | 5,600 ₹28,000 | 1,500 ₹7,500 Lowest | 4,500 ₹22,500 | 3,500 ₹17,500 | 3,000 ₹15,000 |
| 6.00 | All as per Item No . 1 here-in -before but for : 100 KVA DG set .
Make:- Kirloskar/Cummins/ Ashok leyland with AMF panel | 4 | Each Job | 3,000 ₹12,000 | 3,000 ₹12,000 | 6,000 ₹24,000 | 1,500 ₹6,000 | 4,800 ₹19,200 | 1,200 ₹4,800 Lowest | 4,000 ₹16,000 | 3,500 ₹14,000 | 2,000 ₹8,000 |
| 7.00 | All as per Item No . 1 here-in -before but for : 63 KVA DG set .
Make:- Koel with AMF panel | 1 | Each Job | 2,000 ₹2,000 | 2,800 ₹2,800 | 5,000 ₹5,000 | 1,550 ₹1,550 | 4,000 ₹4,000 | 1,000 ₹1,000 Lowest | 4,000 ₹4,000 | 3,000 ₹3,000 | 2,000 ₹2,000 |
| 8.00 | All as per Item No . 1 here-in -before but for : 50 KVA DG set .
Make:- Kirloskar/Cummins with AMF panel | 2 | Each Job | 2,000 ₹4,000 | 2,500 ₹5,000 | 5,000 ₹10,000 | 1,500 ₹3,000 | 4,000 ₹8,000 | 600 ₹1,200 Lowest | 3,000 ₹6,000 | 3,000 ₹6,000 | 2,000 ₹4,000 |
| 9.00 | All as per Item No . 1 here-in -before but for : 40 KVA DG set .
Make:- `Ruston with AMF panel | 1 | Each Job | 2,000 ₹2,000 | 2,200 ₹2,200 | 4,500 ₹4,500 | 1,500 ₹1,500 | 3,600 ₹3,600 | 500 ₹500 Lowest | 3,000 ₹3,000 | 2,500 ₹2,500 | 2,000 ₹2,000 |
| 10.00 | All as per Item No . 1 here-in -before but for : 30 KVA DG set .
Make:- Kirloskar with AMF panel | 2 | Each Job | 2,000 ₹4,000 | 2,000 ₹4,000 | 4,500 ₹9,000 | 1,500 ₹3,000 | 3,500 ₹7,000 | 500 ₹1,000 Lowest | 3,000 ₹6,000 | 2,000 ₹4,000 | 2,000 ₹4,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Jul 2025, 6:00 pmClosed
GE(AF) TA GWALIOR
GE (AF) TA GWALIOR-474020
REPAIR/MAINTENANCE OF DG SETS, AMF PANELS, CONTROL PANELS, VOLTAGE STABILIZERS, ISOLATION TRANSFORMERS, AIR COMPRESSORS, EARTHING / LIGHTNING PROTECTION AND CONNECTED WORK OF DIFFERENT CAPACITY IN EAST WING AND SINGHPUR IN TECH AREA AF STATION GWALI
2025_MES_715866_1
8900/1598/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GWALIOR
Please ref tender documents
7 documents required · 7 mandatory
₹500
GE(AF) TA GWALIOR
₹90,000
Yes
2 Sept 2025
20 Jun 2025
26 Jul 2025
20 Jun 2025
19 Jul 2025
5 Jul 2025
Amount
M/L for Maintenance and servicing of standby DG Set complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleaner , change air cleaner elements, check coolant level & make up the same ,drain the fuel filter & water separator ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, including M&L for changing of V-belts, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load and record shall be made in respect of RPM , oil pressure , oil temperature, coolant temperature, frequency , load current , battery charging , fuel consumption etc complete all as specified and directed by Engineer in Charge for 380 KVA DG set. Make - Cummins with AMF Panel.
All as per Item No . 1 here-in -before but for : 320 KVA DG set . Make:- `Kirloskar with AMF panel
All as per Item No . 1 here-in -before but for : 250 KVA DG set . Make:- `Cummins with AMF panel
All as per Item No . 1 here-in -before but for : 200 KVA DG set. Make:- Cummins/Kirloskar/Greaves cottan with AMF panel
All as per Item No . 1 here-in -before but for : 125 KVA DG set . Make:- `Kirloskar / Cummins with AMF panel
All as per Item No . 1 here-in -before but for : 100 KVA DG set . Make:- Kirloskar/Cummins/ Ashok leyland with AMF panel
All as per Item No . 1 here-in -before but for : 63 KVA DG set . Make:- Koel with AMF panel
All as per Item No . 1 here-in -before but for : 50 KVA DG set . Make:- Kirloskar/Cummins with AMF panel
All as per Item No . 1 here-in -before but for : 40 KVA DG set . Make:- `Ruston with AMF panel
All as per Item No . 1 here-in -before but for : 30 KVA DG set . Make:- Kirloskar with AMF panel
All as per Item No . 1 here-in -before but for : 25 KVA DG set . Make:- `Kirloskar with AMF panel
All as per Item No . 1 here-in -before but for : 20 KVA DG set . Make:- `Kirloskar with AMF panel Note for BOQ Item No 1.00 to 12.00 1. Engine oil for refilling will be measured and paid Separately 2. Coolant for make up will be measured & paid separately 3. DHPP will be issued by dept for testing and top up in tank only. 4. The Make of Fuel filter , Oil Filter , V belt & component will be as per existing or suitable make. 5. The rate quoted against item No. 1.00 to 12.00 is deemed to be inclusive of any break down attendance / rectification during contract period with in 72 hours of complaint received. failing which penalty @ 3000.00 per day will be recovered from work done statement till rectification . 6. A register for record of servicing & break down attendance shall be maintained by contract duly signed by JE /Engineer-in -Charge . 7. Cost of spares & labour charges for attending break down shall be paid under relevant item of this schedule here in after.
Supply only Engine oil SAE 20W-40W complete all as specified and directed.
Supply only fan belt V-Belt of size B-53 complete all as specified and directed.
All as per item No 14 here-in-before but of size B-56
All as per item No 14 here-in-before but of size B-58
All as per item No 14 here-in-before but of size B-64
All as per item No 14 here-in-before but of size B-70
All as per item No 14 here-in-before but of size B-143
All as per item No 14 here-in-before but of size B-180
Supply only coolant for radiator all as specified and directed.
M & L for spray painting the Generator Set including acoustic enclosure and corresponding AMF panel complete with existing colour coding of any capacity after preparation of rough unequal surface and applying two coats of synthetic enamel paint on old steel surface by spray painting in and including lettering and marking i.e Engine make, Engine Sl No, Alternator make, Alternator Sl No etc all as specified and directed by Engineer-in-charge.
S & Fix in repair/replacement of Automatic voltage regulator (AVR) full wave phase controlled adjustable (0-95V) 6A/12A Suitable for DG Set 100-250 KVA including connecting and testing complete all as specified and directed
Supply and fix in replacement of Lead acid battery, 12 volt, 180 AH Confirming to IS 14257-1995 complete all as specified and as directed.
Supply and fix in replacement of Lead acid battery, 12 volt, 150 AH Confirming to IS 14257-1995 complete all as specified and as directed.
Supply and fix in replacement of Lead acid battery, 12 volt, 100 AH Confirming to IS 14257-1995 complete all as specified and as directed.
Supply and fix in replacement of Lead acid battery, 12 volt, 80 AH Confirming to IS 14257-1995 complete all as specified and as directed.
M & L Repair / overhauling radiator assembly of DG set by disconnecting and removing from the engine, dismantling the top and bottom chambers, descaling the sediments, scales, corrosion etc. by means of acid, cleaning and high pressure water washing, air cleaning, re-assembling the same with new gaskets including arresting leakages, if any and fixing to the engine with new hoses, clips etc of 380/320 KVA DG Set complete all as specified and as directed. Note: The rate quoted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges.
M & L in replacement of radiator assembly of DG set by disconnecting and removing from the engine of 125 KVA DG Set complete all as specified and as directed. Note: The item shall be purchased only from the original manufacturer of the mentioned DG set. Purchase Voucher shall be submitted while cleaning payment.
M & L in replacement of radiator assembly of DG set by disconnecting and removing from the engine of 250 KVA DG Set complete all as specified and as directed. Note: The item shall be purchased only from the original manufacturer of the mentioned DG set. Purchase Voucher shall be submitted while cleaning payment.
M & L Repair / overhauling Self starter assembly, 12/24 Volt DC of DG Make: Delco Remi / Lucas TVS assembly of DG Set by disconnecting and removing from the engine, cleaning of all accessories, replacing of worn out parts such as actuator ,gear, solenoid coil ,carbon brushes, bushes, contact plates, jumping leads and seals, revarnishing the field coil, armature and re-assembling the same and re-fixing into the engine including testing all as per original manufacturer's instructions complete all as specified and as directed. NOTE :- 1. The rate quoted by the contractor is deemed to be include for transportation of the item from site to the workshop as applicable and back.
Supply and fix in repair fuel shutup solenoid valve, 12/24 volts, suitable for 380 KVA DG set complete all as specified and as directed. NOTE:- All items to be from manufacturerer's / manufacturers authorised stockiest/ distributor/ dealer only and also the contractor always keep minimum required quantities in hand as a pro-active/ preventive maint/ breakdown
Supply and fix in repair fuel shutup solenoid valve, 12/24 volts, suitable for 250 KVA DG set complete all as specified and as directed. NOTE:- All items to be from manufacturerer's/manufacturers authorised stockiest/ distributor/ dealer only and also the contractor always keep minimum required quantities in hand as a pro-active/ preventive maint/ breakdown
Supply and fix in repair fuel shutup solenoid valve, 12/24 volts, suitable for 125 KVA DG set complete all as specified and as directed. NOTE:- All items to be from manufacturerer's /manufacturers authorised stockiest/ distributor/ dealer only and also the contractor always keep minimum required quantities in hand as a pro-active/ preventive maint/ breakdown
S & Fix in replacement of SMPS based Battery charger module 24/12 volt 15/20A Amps having CC,CV, trickle, float and boost charging mode suitable for AMF Panels of DG Set 20/25/40/50/100/125/200/250/320/380 KVA capacity complete all as specified and as directed.
S & F in repairs Lub oil pressure transducer suitable for DG set upto 250 KVA system complete all as specified and as directed.
S & F in repairs Lub oil pressure transducer suitable for DG set upto 125 KVA system complete all as specified and as directed.
S & Fixing in repairs Lub oil pressure transducer suitable for DG set upto 100 KVA system complete all as specified and as directed.
S & Fixing in repalacement of proximity Magnetic pickup for sensing RPM of DG set 250/380 KVA capacity with existing model complete all as specified and as directed.
S & Fixing in replacement of Low lub oil pressure safety switch suitable for DG set 250/200KVA and connecting with DG set system, testing complete all as specified and as directed.
S & Fixing in repairs High water temperature trip safety switch suitable for DG set 320KVA and connecting with DG set system, testing complete all as specified and as directed.
Supply & Fix in repair of ON LOAD change over switch, 4 pole, 630 Amps, in open execution / Panel mounting , front operated complete all as specified and as directed.
Supply & Fix in repair of ON LOAD change over switch, 4 pole, 400 Amps, in open execution / Panel mounting, front operated complete all as specified and as directed.
Supply & Fix in repair of ON LOAD change over switch, 4 pole, 250 Amps, in open execution / Panel mounting, front operated complete all as specified and as directed.
S & Fixing in replacement of wiring harness for 100/160/180/200/250KVA DG set with proper lugs /ferrules/nuts bolt with washers and testing the circuit complete all as specified and as directed.
S & F following items in AMF Panel of any description and in any position of capacity DG Set upto 500 KVA including checking AC/DC circuits, tightning of all power / control wiring connection and replacement of unserviceable control wiring with suitable size, single core, copper conductor, flexible, PVC insulated, unsheathed cable suitable upto 1100 volts confirming to IS-694, taking out, removing and replacement of unserviceable parts / spares / items to make AMF functional including testing complete all as specified and directed
Pla relay 24 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -24D of pla make or equivalent of Eagle man.
Pla relay 12 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -12D of pla make or equivalent of Eagle man.
Ammeter size 96 mm X 96mm, flush mounted digital type, three phase of class 1.0 complete all as specified and directed.
Voltmeter size 96 mm X 96mm, flush mounted digital type, three phase, class 1.0 complete all as specified and directed.
Frequency meter size 96 mm X 96mm, flush mounted digital type, three phase, class 0.2 complete all as specified and directed.
Under voltage relay suitable for 3 phase 415 volts, AC supply as per existing make complete all as specified and directed.
Engine starting relay with sequence timer & master timer suitable for 12 / 24 Volts DC supply as per existing make complete all as specified and directed.
Electronic timer, time range from 3 seconds to 10 seconds, suitable of 12/ 24 Volts, 50 Hz, AC supply as per existing make complete all as specified and directed.
LED Indicator 22.5mm for 12 /24 volts AC/DC supply complete all as specified and directed.
MCB single pole, 10 KA, rating 6 to 32 Amps ‘C’ series, 240 volts complete all as specified and directed.
M&L for repairing of canopy of DG set of any capacity by carrying out repairing of door with replacement of broken hinges including nuts, bolts/welding etc as per requirement, cleaning of base of foundation and painting with black paint MS channel with two coats including touching of paint at canopy where required complete all as specified and directed.
Material and labour for dismantling and taking out and rewinding of Alternator startor assembly of 320 KVA DG Set and rewinding of approved suitable gauge super enamel insulated copper winding wire with necessary insulating materials reassembling and transportation to workshop and bring back to origins at installation and fixing, testing and commissioning complete all as specified and directed.
All as per item No 48 here-in-before but of Capacity 250 KVA DG set.
All as per item No 48 here-in-before but of Capacity 200 KVA DG set.
All as per item No 48 here-in-before but of Capacity 125 KVA DG set.
All as per item No 48 above but of Capacity 100 KVA DG set.
All as per item No 48 here-in-before but of Capacity 63 KVA DG set.
S & F in repair governor control unit for electronic governor suitable for DG Sets of capacity 125 KVA of existing make complete all as specified and directed.
S & F in repair governor control unit for electronic governor suitable for DG Sets of capacity 250 KVA of existing make complete all as specified and directed.
S & F in repair governor control unit for electronic governor suitable for DG Sets of capacity 320 KVA of existing make complete all as specified and directed.
S&F in repair Actuator ETR fuel control unit of cummins/Kirloskar make DG sets of 320-380 KVA capacity complete all as specified and directed.
S&F in replacement engine electronic (instrumentation) digital panel comprising of starting switch ON/OFF water temp display, hour meter cum RPM display, lubricant oil pressure display, lubricant oil temperature display, battery charging display, safety alarm against high water temp and lubricant oil pressure for DG Set of 250-320KVA capacity complete all as specified and directed
M&L in replacement of AMF Power contactor, 4 pole, 415 Volts, 600 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
M&L in replacement of AMF Power contactor, 4 pole, 415 Volts, 400 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
M&L in replacement of AMF Power contactor, 4 pole, 415 Volts, 320 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
M&L in replacement of AMF Power contactor , 4 pole, 415 Volts, 250 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
M&L in replacement of AMF Power contactor , 4 pole, 415 Volts, 100 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
M&L in replacement of AMF Power contactor , 4 pole, 415 Volts, 63 Amps, 50 Hz, AC , with 2 NO and 2 NC contacts including any modification to existing panel frame size and fixing new contactor with connecting bars to the main busbar, incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.
Supply only in replacement of Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,(0-600A) Current , P.F, frequency on existing AMF panel including necessary P.T & C.T's with all connected accessories all as specified and directed
S & F in replacement of push button switch with NO/NC contacts 415 V ,6A , with add on Aux Contacts and connected acccessories all as specified and directed
M&L in replacment of MCCB, 3 poles 415 Volts, 100 Amps, 16 kA, ics=100%icu, 50 Hz, AC, adjustable type in the existing AMF panel board/sheet metal enclosure including any modification to existing panel frame size and fixing new MCCB with connecting bars to the main busbar and connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed.
All as per item No 68 here in before but MCCB 3 pole, 125 Amps, breaking capacity Icu = 16 KA.
All as per item No 68 here in before but MCCB, 4 pole, 160 Amps, breaking capacity Icu = 36 KA.
All as per item No 68 here in before but MCCB, 4 pole, 200 Amps, breaking capacity Icu = 36 KA
All as per item No 68 here in before but MCCB, 4 pole, 250 Amp, breaking capacity Icu = 36 KA
All as per item No 68 here in before but MCCB, 4 pole, 320 Amp, breaking capacity Icu = 36 KA
All as per item No 68 here in before but MCCB, 4 pole, 400 Amps, breaking capacity Icu =36 KA
All as per item No 68 here in before but MCCB, 4 pole, 630 Amps, breaking capacity Icu = 50 KA
Supply and fix PVC insulated multistranded copper cable suitable for DG sets battery lead of size 25 Sqmm all as specified
Supply and fix in replacement of gunmetal battery connecting terminal suitable for 12v/24v battery all as specified and directed
Supply only spray can 500ml for cleaning electrical contacts and decarbonising electrical parts all as specified and directed
M & L in replacement of flywheel with gear tooth assembly and align center/level between alternator and engine and testing complete all as specified and directed by engineer in charge
S&F DG Set specification board made out of flexible acrylic sheet of Size 2 x 3 feet background of blue colour with white letters of size 50/40mm for alongwith all fixing arrangements different type and model of DG Set as per sample and as directed by the Engr-in-Charge including removing old existing damaged board and accessories all as directed
S & Fix in repair, replacement of Automatic voltage regulator (AVR) full wave phase controlled adjustable (0-95V) 6A/12A Suitable for DG Set AVR(MODEL AS440)S/F STAMFORD and other equal models including connecting and testing complete all as specified and directed
M&L for Earthing complete for panels with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m deep below normal ground level with top edge of earth plate, not less than 1.5 m below normal ground level connected to galvanised iron earth strip of size 32x6 mm using bolts, nuts/check nuts and washers etc of galvanised iron, connected to main switch/control board including necessary excavation & earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 6 mm dia TMT Bars at 140 mm c/c both ways, watering pipe 20 mm dia light grade GI, funnel, wire mesh, lugs, charcoal and common salt etc complete all as shown in Electrical plate No. 3 of SSR Part I and testing complete including taking down old unserviceable items complete all as specified and directed. Note:- (i) GI strip and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing.
M & L for overhauling of complete DG set of capacity 50 KVA by disconnecting and removing the following parts from the engine, and refixing/re-assembling the new parts on site/ workshop complete all as specified and directed. (a)Valve, intake (b) Bearing, coonecting rod (c) seal, oil (d) Seal, O ring (e) Sender-pressure (f) Valve, exhaust (g) collet valve (h) spring, valve (i) Gasket Cylinder head (j) Camshaft (k) Kit, Engine piston (l) Cover, accessory drive (m) Injector (n) Pin, Piston (o) Retainer , Valve spring (p) Gasket, Gear cover (q) Sensor-Temperature. Note: (1)The rate quoted shall be inclusive of transporting of the complete engine to the workshop and back and all incidental charges. (2) The overhauling will be carried out by only the OEM and the parts should be purchased from the authorised dealer only.
M&L in replacement for controller display EMS 907 including necessary programming ,restoring the data and complete all as specified and directed.
M&L in replacement for controller display SEDMAC-KG-645 including necessary programming ,restoring the data and complete all as specified and directed.
M&L in replacement for controller display POWER COMMAND HMI-211- including necessary programming ,restoring the data and complete all as specified and directed.
Supply only in replacement of monoblock motor pump suitable for fuel refilling ,1.5 HP, single phase, complete all as specified and directed.
Supply only in replacement of flexible PVC pipe, nylon threaded, transparent type of size 1.5" for fuel filling to DG set complete all as specified and directed.
M&L in repair for necessary PCC (1:2:4) type B-2 ,40 mm graded stone aggregate for foundation of DG Set, AMF Panel, Pathway to DG Set for making the smooth access from Road complete all as specified and directed.
M&L in repair for necessary PCC (1:3:6) type C-1 , 20 mm graded stone aggregate for foundation of DG Set, AMF Panel, Pathway to DG Set for making the smooth access from Road complete all as specified and directed.
JAI SHITLA CONSTRUCTION COMPANY (BID ID -3356044)
m/s anil traders (BID ID -3356246)
Om Electricals (BID ID -3363368)
Kumar Sales Corporation (BID ID -3364131)
M/s Anupam Construction Co. (BID ID -3354708)
SHRI RAM CONSTRUCTION (BID ID -3364694)
M/s Shanti Enterprises (BID ID -3364774)
M/S Amit Traders (BID ID -3356790)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .