Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.3 L+₹73,843.20 (1.69%)Rejected-AOC GROUND FLOOR 281 1 D SHIVRAI NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹44.7 L+₹1.2 L (2.67%)Rejected-AOC | L3 | Rejected-AOC Being L3 | |
| 4 | L4₹45.1 L+₹1.5 L (3.45%)Rejected-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-AOC Being L4 | |
| 5 | L5₹46.8 L+₹3.2 L (7.40%)Rejected-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L5 | Rejected-AOC Being L5 |
| Sl No | Description | Qty | Unit | M/S - KRUPA ELECTRICALS L5 | SKS Electricals L4 | MAYUR ELECTRIC SERVICES L1 | Star Electrical L3 | YOGESH ELECTRICALS L2 | GANGA ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/LT underground cable, pole or stay and getting out in Hard soil complete all as specified and directed. | 243 | Cubic Metre | 330.9 ₹80,408.7 | 318.9 ₹77,492.7 | 300 ₹72,900 Lowest | 316.5 ₹76,909.5 | 313.5 ₹76,180.5 | 334.5 ₹81,283.5 |
| 2.00 | All as per item No 01 here-in-before but exc 1.5 mtr and n.exc 3.0m in depth for erection of pole etc complete all as specified and directed by Engr-in-Charge | 1 | Cubic Metre | 385 ₹385 | 372.05 ₹372.05 | 350 ₹350 Lowest | 369.25 ₹369.25 | 365.75 ₹365.75 | 390.25 ₹390.25 |
| 3.00 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as directed by Engr-in-Charge | 145 | Cubic Metre | 82.5 ₹11,962.5 | 79.72 ₹11,560.12 | 75 ₹10,875 Lowest | 79.12 ₹11,473.12 | 78.38 ₹11,364.38 | 83.62 ₹12,125.62 |
| 4.00 | Removing excavated surplus soil to a distance not exceeding 50 metre and deposting where directed at a level not exceeding 1.5 metre above the the starting point complete all as specified and directed by Engr-in-Charge | 98 | Cubic Metre | 82.5 ₹8,085 | 79.72 ₹7,813.05 | 75 ₹7,350 Lowest | 79.12 ₹7,754.25 | 78.38 ₹7,680.75 | 83.62 ₹8,195.25 |
| 5.00 | Supply and lay in trenches un-reinforced precast concrete cable cover class LV type I of size 250 x 150 x 40mm for cable protection all as specified and directed by the Engr-in-Charge. | 3,780 | Each | 33 ₹1,24,740 | 31.89 ₹1,20,544.2 | 30 ₹1,13,400 Lowest | 31.65 ₹1,19,637 | 31.35 ₹1,18,503 | 33.45 ₹1,26,441 |
| 6.00 | Material and labour for riddled earth filling in trenches to required width at bottom and top of cable as cushioning including spreading leveling and consolidation complete all as specified and as directed. Note : Punned thickness shall measured and paid | 73 | Cubic Metre | 550 ₹40,150 | 531.5 ₹38,799.5 | 500 ₹36,500 Lowest | 527.5 ₹38,507.5 | 522.5 ₹38,142.5 | 557.5 ₹40,697.5 |
| 7.00 | Taking out old serviceable/unserviceable LT UG cables of size 10 to 70 sqmm 3.5/4 core from trenches, poles/walls and floor including taking out old unserviceable/serviceable bricks covers/GI pipe of any size from trenches for removing or re-laying (after necessary repair/jointing) the cable complete all as specified and directed by Engr-in-Charge. | 600 | Running Metre | 22 ₹13,200 | 21.26 ₹12,756 | 20 ₹12,000 Lowest | 21.1 ₹12,660 | 20.9 ₹12,540 | 22.3 ₹13,380 |
| 8.00 | All as per item No 07 here-in-before but size of 95 to 300 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge
Note for Item No 7 & 8 : Earthwork and excavation shall be measured and paid separately. | 500 | Running Metre | 33 ₹16,500 | 31.89 ₹15,945 | 30 ₹15,000 Lowest | 31.65 ₹15,825 | 31.35 ₹15,675 | 33.45 ₹16,725 |
| 9.00 | Re-laying XLPE UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 70 Sqmm 3.5/4 core (item retreived from item No 7 here-in-before) laid in trenches or fixed on wall/floor/poles complete all as specified and directed. | 90 | Running Metre | 44 ₹3,960 | 42.52 ₹3,826.8 | 40 ₹3,600 Lowest | 42.2 ₹3,798 | 41.8 ₹3,762 | 44.6 ₹4,014 |
| 10.00 | All as per item No 09 here-in-before but size of 95 to 300 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge | 60 | Running Metre | 55 ₹3,300 | 53.15 ₹3,189 | 50 ₹3,000 Lowest | 52.75 ₹3,165 | 52.25 ₹3,135 | 55.75 ₹3,345 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
7 Jul 2025, 6:00 pmClosed
GE RnD Pashan
GE RnD Pashan
REPAIR / MAINTENANCE OF E/M INSTALLATION, UG CABLES, LT PANEL BOARDS AND MISC WORKS AT HEMRL UNDER GE (I) RnD PASHAN
2025_MES_714769_1
GERD/PSN/TOKEN/32 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE RnD Pashan
As per tender documents
9 documents required · 9 mandatory
₹500
GE RnD Pashan
₹90,000
Yes
6 Aug 2025
16 Jun 2025
9 Jul 2025
16 Jun 2025
7 Jul 2025
30 Jun 2025
16 Jun 2025 - 23 Jun 2025
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/LT underground cable, pole or stay and getting out in Hard soil complete all as specified and directed.
All as per item No 01 here-in-before but exc 1.5 mtr and n.exc 3.0m in depth for erection of pole etc complete all as specified and directed by Engr-in-Charge
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as directed by Engr-in-Charge
Removing excavated surplus soil to a distance not exceeding 50 metre and deposting where directed at a level not exceeding 1.5 metre above the the starting point complete all as specified and directed by Engr-in-Charge
Supply and lay in trenches un-reinforced precast concrete cable cover class LV type I of size 250 x 150 x 40mm for cable protection all as specified and directed by the Engr-in-Charge.
Material and labour for riddled earth filling in trenches to required width at bottom and top of cable as cushioning including spreading leveling and consolidation complete all as specified and as directed. Note : Punned thickness shall measured and paid
Taking out old serviceable/unserviceable LT UG cables of size 10 to 70 sqmm 3.5/4 core from trenches, poles/walls and floor including taking out old unserviceable/serviceable bricks covers/GI pipe of any size from trenches for removing or re-laying (after necessary repair/jointing) the cable complete all as specified and directed by Engr-in-Charge.
All as per item No 07 here-in-before but size of 95 to 300 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge Note for Item No 7 & 8 : Earthwork and excavation shall be measured and paid separately.
Re-laying XLPE UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 70 Sqmm 3.5/4 core (item retreived from item No 7 here-in-before) laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
All as per item No 09 here-in-before but size of 95 to 300 sqmm 3.5 core complete all as specified and directed by Engr-in-Charge
Supply and laying XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor including necessary lugs, glands as required of following size in trenches or fixed on wall/floor/poles complete all as specified and directed. (a) 16 Sqmm 4 Core
(b) 25 Sqmm 3.5 Core
(c) 50 Sqmm 3.5 Core
(d) 95 Sqmm 3.5 Core
(e) 185 Sqmm 3.5 Core
(f) 300 Sqmm 3.5 Core
Re-laying old serviceable PCC cable cover, obtained from excavation here-in-before for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed by Enigneer-in-Charge
Material and labour for cutting of grass/bushes surounding the area of substation/out door type feeder pillar box 4 pole stracture and remove the deposited materials to a distance not more than 50 mtr away from the site including cleaning the out side and inside of the sub station building and making the surface clean complete all as specified and directed by Engr-in-Charge.
Surface excavation in soil for taking out pebbles including removing vegetation and bushes not exceeding 30cm depth & averaging 15cm deep in sub station complete all as specified and directed.
Material and Labour for hardcore of gauge 40 mm deposited, spread & levelled in layers n. exc 15 cm thick, watered & rammed to a true surface with broken stone or boulders complete all as specified and directed.
Supply install testing and commissioning of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete with explusion fuses, GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts suitablly tinned to withstand weather complete including taking down existing Unserviceable AB switch all as specified and directed. Make:- Jaipuriya Brothers or Pactil
All as per item No 21 above but current rating upto 400 Amps
Supply and Fix Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning complete including taking down existing Unserviceable fuse all as specified and directed
Supply and fix lightining arrester suitable for 18 KV station class including taking down old unserviceable set all as specified and directed by Engineer-in -Charge.
Material and Labour for ACSR conductor (Ferret) jumper connections of following lengths both ends secured with suitable aluminium lugs or one end with AI lugs and other end plain for binding with conductor encased with polythene sleeve, RYB colours of suitable dia complete all as specified and directed for :- a) Not exceeding 0.75 meter length.
b) Exceeding 0.75 meter length but not exceeding 1.5 meter length.
c) Exceeding 1.5 meter length but not exceeding 2.5 meter length.
d) Exceeding 2.5 meter length but not exceeding 3.0 meter length.
Material and labour for special factory made earthing electrode comprising of hot dipped galvaized MS flat inserted in to GI pipe of 88 mm bore (outer), 3meter length, filled with non magnetic anti corrosive material specially developed for ground resistance enhancement power around the electrode to retain moisture conforming to IS 3043 including necessary boring in ground of 150 / 200mm dia in any type of strata connecting to test point all as specified and directed (the earth resistance shall be less than 1 ohms . Contractor shall improve the earthing resistance within the permissible limit without any extra cost complete all as specified and directed. Note : Rate for FRP earth pit cover shall be deemed to be included in quoted rate
Dismantling and Transpporting setting aside the steel poles/struts, any size complete all as specified and directed
Supply and fix HT steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, 9 metre long including painting wth one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting three black/red bands at lower portion of pole each of 300 mm height at 300 mm spacing, painting pole No with black paint at suitable height complete all as specified and directed by Engr-in-Charge.
Supply and fix HT steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, 11 metre long including painting wth one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting three black/red bands at lower portion of pole each of 300 mm height at 300 mm spacing, painting pole No with black paint at suitable height complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundations of stays and poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 with 20 mm graded stone aggregate for coping of pole including necessary form work complete all as directed.
Material and labour for cement concrete PCC 1:4:8 type D2 using 40mm graded aggregate as in pole coping complete all as specified and directed
Material and Labour for repairing the existing LT feeder pillar boxes of any size by welding the damaged hinges / aligning the doors to fit properly including providing rubber gasket and locking arrangement complete all as specified and directed by Engr-in-Charge.
Material and labour for preparation of old painted steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coat of aluminium paint complete all as specified and directed.
Material and labour for drilling suitable dia horizontal bore holes for insertion /laying of 50/100mm bore GI tubing of any description below/under road surface /floors etc with using mechanical or manual devices as required at site including making good distrubed surface to match with the existing surface after laying pipes complete all as specified and directed
Supplya and fixing of GI tubing light grade of 80mm dia for cable protection on pole/wall/floor/or in trenches and drain etc complete with necessary clamp, nut bolts and washers and socket and making good the distrubed surface of wall, floor or roof etc complete all as specified and directed
All as per item No 39 above but of dia 50mm complete all as specified and directed
Material and labour for jointing kit suitable for LT 1100 volts cable (earthed) for out door straight through joint, heat shrinkable type complete with jointing material and accessories suitable for 25 to 50 sqmm 3.5 core XLPE armoured aluminium conductor cable complete all as specified and directed
All as per item No 41 here-in-before but suitable for size 70 to 150 sqmm 3.5 core cable complete all as specified and directed.
All as per item No 41 here-in-before but suitable for size 185 to 300 sqmm 3.5 core cable complete all as specified and directed.
Materiala and labour for Bus bar Panel of capacity 200 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 50x50x6mm thick grounting in floor, 0.45mm depth with PCC 1:3:6 type C1 using 20mm graded up to ground level complete all as specified and directed
Materiala and labour for Bus bar Panel of capacity 100 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 45x45x5mm thick grounting in floor, 0.45mm depth with PCC 1:3:6 type C1 using 20mm aggregate up to ground level complete all as specified and directed
Repiar to LT ACB of capacity 800/1000 Amps by disconnecting from the busbar and replacing all unserviceable parts of finger contact with male female set and wiring with new copper conductor cable of 2.5 sqmm. Replacing the unserviceable mechanical spring system, fixing and moving contacts, replacement of bearing of spring charge motor and rewinding of control transformer with super enameled copper wire of gauge and replacement of FRCD (Free return charge device) all connected work require at site for proper and smooth functioning of air circuit breaker all as specified and directed. Make : L&T Model No CN CS 800, CN CS 100
Supply and fixing in repair on load changeover switch in sheet steel enclosure with extended handle of capacity 200 Amps, 4 pole, 415 Volts, 50 HZ including fixing on wall by means of grouting bolts and connecting cable with suitable lugs/thimbles complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair on load changeover switch in in open execution extended handle handle of capacity 250 Amps, 4 pole, 415 Volts, 50 HZ including fixing on wall by means of grouting bolts and connecting cable with suitable lugs/thimbles complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair capacitor bank 10 KVAR, standard duty, box type including fixing on wall by means of suitable nuts and bolt and connecting from exising LT distribution system complete all as specified and directed. Make : L&T , Series LTBCD or equivalent in Havells/Standard
Supply and fixing capacitor bank 5 KVAR, standard duty, box type, including fixing on wall by means of suitable nuts and bolt and connnecting from existing LT distribution system complete all as specified and directed.
Supply and fixing capacitor bank 20 KVAR, standard duty, box type, including fixing on wall by means of suitable nuts and bolt and connnecting from existing LT distribution system complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and directed by Engr-in-Charge.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and directed by Engr-in-Charge.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and directed by Engr-in-Charge.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and directed by Engr-in-Charge.
Supply and fixing 32mm dia x 1.5 metre long GI pipe bracket light grade for mounting of street light fitting on pole including bending the pipe to the required shape, 2 Nos 40mm x 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and paint etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing 50mm dia x 1.5 metre long GI pipe bracket light grade for mounting of street light fitting on pole including bending the pipe to the required shape, 2 Nos 40mm x 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and paint etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 300mm X 200mm X 105 mm (internal ) comprising one No MCB single pole of capacity 6 Amps 240 volts 'C' curve 10 KAand one No terminal for loop in and loop out suitable for three phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25mm x 3mm MS flat iron complete all as specified and directed.
Wiring circuit/submain wiring alongwith earth wire with 2 x 2.5 sq mm + 1 x2.5 Sq mm earth wire of FRLS PVC insulated copper conductor, single core cable passing through steel tubular pole connecting with street light fitting to junction box complete all as specified and dircted by Engr-in-Charge.
Complete removal of existing treatment including preparation of old painted surfaces by washing, rubbing down and stopping of painted surfaces, painting with one coat of synthetic enamel paint of approved colour on centrifugal pump set of 50 HP to 120 HP capacity including inlet, outlet mains, couplings, sluice valve, non return valve, base plate, pulley with safe gaurd, vacume pipe line, LT panel board and writting the MES / SM number with black paint of suitable size of letters complete all as specified and directed.
All as per item No 26 above but for 10 HP to 40 HP centrifugal pump set.
All as per item 26 above but for up to 7.5 HP centrifugal pump set.
Supplying and laying synthetic rubber insulated mats 3mm thick for voltage upto 22/33 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engr-in-Charge
Supply and Fix in repair rigid PVC line separator made from high grade PVC material, rigid PVC Spacer, distance betwen phase to phase 300mm, suitable for use with 1100 volts grade 2 conductor feeder complete all as specified and directed
Supply and Fix in repairs rigid PVC line separator made from high grade PVC material, rigid PVC Spacer, distance betwen phase to phase 300mm, suitable for use with 1100 volts grade 4 conductor feeder complete all as specified and directed
Material and Labour for two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed.
Dismantling of fencing wire mesh, any type complete all as specified and directed.
Supply and fixing chain link fencing of size 50X50X3.15mm dia weight per sqm not exceeding 4 kg complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Dismantling cross-arms of MS channel or angle sections etc complete and setting aside for re-use with in 50m complete all as specified and directed
Material and labour for mild steel cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts washers, welding, bending cold or hot , drilling holes for bolts in any shape/size as directed including painting with two coats of approved colour over a coat red oxide primer all as specified and directed by Engr-in-Charge
Supply and Fix in repair 4 pole, 400 Amps, 415 Volts, 36 KA adjustable thermal and magnetic setting complete including connecting by means of suitable size of connectore and connecting out going/imcoming cable complete all as specified and directed by Engr-in-charge
All as per item No 72 here-in- before but of capacity 250 amps 4 Pole, 25 KA complete all as specified and directed
All as per item No 72 here-in- before but of capacity 200 amps 4 Pole, 25 KA complete all as specified and directed
All as per item No 72 here-in- before but of capacity 630 amps 4 Pole, 50 KA complete all as specified and directed
Supply and fixing in repair power contactor 4 pole 400 Amps, 415 Volts in existing AMF panel complete including connecting by means of suitable size of connector and connecting all control wire complete all as specified and directed by Engr-in-Charge.
All as per item No 76 here-in- before but of capacity 250 amps 4 Pole, 415 Volts complete all as specified and directed
Material and labour for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip 32mm x 6 mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 03 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber including necessary formwork / mould for fair and even surfaces, precast RCC 1:2:4 type B0 chamber cover slab, GI funnel, with GI watering pipe 20 mm bore med gde, wire mesh, protection pipe 40 mm bore GI pipe light gde for earth lead upto 7.50 m long including testing complete in any type of soil/ strata all as specified and directed by Engineer-in-Charge. Note : (i) GI strip beyond 7.5 mtr will be measured and paid sepeartely. (ii) Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & PMG / user. Test results are to be written in letters of 20mm height in white colour on black paint back ground. (iii) The earth resistance should be less than 2 Ohm.
Supply and fix GI strip of size 32 x 6 mm on existing walls / buried under ground, on existing insulators any type including jointing the system of conventional type lightening protection network and making good the disturbed surface of walls complete all as specified and as directed.
YOGESH ELECTRICALS (BID ID -3348821)
Star Electrical (BID ID -3349964)
SKS Electricals (BID ID -3349473)
M/S - KRUPA ELECTRICALS (BID ID -3348378)
GANGA ENTERPRISES (BID ID -3348982)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .