Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | ₹23.8 L Quoted ₹24.4 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹28.9 L+₹4.5 L (18.3%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | ₹28.9 L+₹4.5 L (18.3%) | L2 | Rejected-Finance Higher bid value |
| 3 | L3₹30.3 L+₹5.9 L (24.1%)Rejected-Finance B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | ₹30.3 L+₹5.9 L (24.1%) | L3 | Rejected-Finance Higher bid value |
| 4 | L4₹33.7 L+₹9.3 L (38.2%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹33.7 L+₹9.3 L (38.2%) | L4 | Rejected-Finance Higher bid value |
| 5 | L5₹34.4 L+₹10.0 L (41.1%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | ₹34.4 L+₹10.0 L (41.1%) | L5 | Rejected-Finance Higher bid value |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
3 Aug 2021, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
REPAIR/REPLACEMENT OF LT UG CABLE, MCCBs, UNSV LT PANEL, ACSR CONDUCTORS, ELECTRIC POLES AND ALLIED WORKS AT ZONE III AND IV UNDER GE DINJAN
2021_MES_447575_2
C/8295/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹70,000
Yes
1 Sept 2021
12 Jul 2021
5 Aug 2021
12 Jul 2021
3 Aug 2021
16 Jul 2021
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
Taking out/down old/unserviceable under ground LT cables of any size and connections including pipes etc from trenches/walls/poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 4 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 25 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 35 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excvation and earth work shall be measured and paid seperately.
Boring of holes horizontall for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hardstanding using trenchless technology complete all as specified and as directed. Note : Cost of accessories required for making hole/bore deemed to be included in the quoted rate.
M&L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
M&L for 80 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
M&L for 100 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 6 Sqmm to 16 Sqmm 2/3.5/4 Core complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately.
Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 25 Sqmm to 50 Sqmm 2/3.5/4 Core complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately.
Supply, jointing and testing XLPE cable straight through joints including jointing materials and accessories complete, cold shrinkable outdoor cable joint kit suitable for XLPE 1100 Volts (Earthed) cable of size 70 Sqmm to 120 Sqmm 2/3.5/4 Core complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately.
Dismantling/uprooting of LT unserviceable pre-stressed concrete/steel poles of any size and shape and including taking out dismantled portion of poles embeded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and as directed. Note:- Earth work for taking out poles shall be measured and paid separately under relevant item of this Schedule.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including two coats of aluminium paint over a coat of primer except the planting depth which shall be painted with black bituminous paint including writing pole number using suitable paint complete all as specified and as directed. Note : Excavation and Earth work, PCC filling shall be measured and paid separately.
M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in pole foundation complete all as specified and as directed.
M&L for cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in filling and mass concrete complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of pole including necessary form work for fair finish surfaces complete all as specified and as directed
Dismantling LT Stay assembly, of any size and removing from the site(s) complete all as specified and as directed.
M&L for stay assembly comprising of 7/8 SWG galvanised stay of standard wire of reqd length fixed to pole with and including galvanised flat iron clamps, bolts, nuts and washers etc including galvanised steel 14 mm dia, 400 mm long stay bow and GI stay plate of size 300 x 300 x 6 mm thick, thimble MS clamp made out of 50 x 6mm and loop insulators porcelain brown all as shown in EP No.1 of SSR part - I including all accessories and excavation, earth work and PCC work complete all as specified and as directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and stacking aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work complete all as specified and as directed.
M&L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and as directed.
M&L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 150 mm height 150mm dia suitable for 1100 volts grade complete all as specified and as directed.
M&L for shackle type porcelain, insulator vitreous, white, brown or green, including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115 mm dia, size of strap 31 mm x 5 mm and dia of bolt 14 mm suitable for 1100 volts complete all as specified and as directed.
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size any type from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and as directed
Supply, fixing and stringing of aluminium conductor steel reinforced (ACSR) conductor of size (a) Squireel 6/1 x 2.11, (b) Weasel 6/1 x 2.59, (c) Rabbit 6/1 x 3.25 as suitable conforming to IS - 398 part- 4 of 1994 including binding, straining in LT over head line including all jumper connection and binding on insulator with new wire/aluminium tape complete all as specified and as directed.
Restringing of old aluminium conductor steel reinforced (ACSR) or AAAC conductor of any size and make on LT 9 m long poles alongwith earth wire, including replacement of binding wire and aluminium taps reconnection, street light connections, service connections and binding to insulators with suitable size of new binding wire including prunning of tree branches 2 mtr all around OH LT line by means of pulley, rope etc complete all as specified and as directed. Note : 04 Nos of ACSR or AAAC conductor shall be measured as one unit length.
S&F for PVC/fibre separator for LT over head line 1100 volts conductor 3/4 wire system, suitable for 2 conductor, in span without damaging the over head line including taking down old separator complete all as specified and as directed .
S&F for PVC/fibre separator for LT over head line 1100 volts conductor 3/4 wire system, suitable for 4 conductor, in span without damaging the over head line including taking down old separator complete all as specified and as directed .
S&F in repairs 1100 volts grade heavy duty cable PVC insulated aluminium conductor, stranded of size 10 Sqmm x 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia GI suspension wire, one twin core cable flat or circular etc complete all as specified and as directed.
S&F for PVC conduit pipe 20mm dia with fixing arrangement with flat iron with nut bolts on pole complete all as specified and as directed.
S&F in repairs Modular Junction box made of SMC/FRP of size 250x200x105mm with provision of MCB SP, 6-32A, 10 KA, 'C' Curve, 01 No and connector terminal 4 pole indicating RYB Phase Colour and Neutral colour complete fixed to street light pole with suitable size of mild steel clamps, nuts & bolts complete all as specified and as directed. Make : CAT No : GSJB 2520 of Sintex or equivalent.
S&F for three phase bus bar chamber ( 4 way), wall mounted, suitable for 100 Apms current rating and cable connection with IP 66 protection connecting all the incoming and outgoing cable terminals with lugs complete all as specified and as directed. Make : Cat No IHBC010006 of Havells / L&T / Legrand.
S&F in replacement precast RCC cable route indicator duly marked/grouted and painted for HT/LT cable of size 60x25x7.5cm with suitable size of 6mm dia reinforcement 1.0 Kg in each complete all as specified and as directed.
S&F in replacement of synthetic insulating mat of size 2.0mx1.0mx19mm at substations and other installations complete all as specified and as directed.
M&L for making of name board with 6mm thick PVC board and with mentioning letters of size not more than 50mm size (sticker type computor letters) all as specified and as directed for switch boards duly fixd to the wall with suitable fixing arrangements etc complete all as specified and as directed.
M&L for making danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT, 20 x 15 cm size including dismantling of old one complete all as specified and as directed.
M&L for preparation of old painted surface and removing dust and other deposited material by scraping from LT PSC/steel tubular poles of upto 11.00 metre long, cross arms brackets and applying two coats of aluminium paint to all steel surfaces, including MS clamps, cable protection pipe, bracket fitted with street light fittings etc and one coat of cement based paint to PSC pole including Zebra colour of painting upto 2.1 m height from the top of coping/bottom of pole as per site condition and numbering of poles complete all as specified and as directed. Note : Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer.
Supply, install, testing and commissiong in replacement of outdoor LT Feeder Pillar Box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made out of 2 mm thick CRCA sheet steel for load bearing protection of enclosure IP-54 complete hinged door with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work supports, excavation and earth work, PCC foundation etc, cubical type as required with and including the following, supplied fitted and connected internally complete (a) 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 300 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators complete all as specified and as directed.
S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 400 Amps of breaking capacity 25 KA complete all as specified and as directed. Make : Cat No. CSE3M400ATM4P of C&S/ Havells/ L&T/Legrand.
S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 250 Amps of breaking capacity 25 KA complete all as specified and as directed. Make : Cat No. CSE2M250ATM4P of C&S/ Havells/ L&T/Legrand.
S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 200 Amps of breaking capacity 25 KA complete all as specified and as directed. Make : Cat No. CSE2M250ATM4P of C&S/ Havells/ L&T/Legrand.
S&F in replacement of MCCB, 4 pole, 415 V with adjustable thermal & adjustable magnetic setting, 160 Amps of breaking capacity 25 KA complete all as specified and as directed. Make : Cat No. CSE2M250ATM4P of C&S/ Havells/ L&T/Legrand.
M&L for preparation of external/internal surfaces of panel boards/Feeder pillar boxes, consoles etc by scrubbing /CTC by emary paper by removing stains/rusted scales etc, and applying two coats of synthetic enamel paint complete and cleaning meters/indicators / MES Nos, making good complete etc complete all as specified and as directed.
Taking down aviation obstruction light any type / cap from the top of the OH water resrvoir of approx 15 to 18 m above the ground level by means of safety staging /safety belt hook-up etc, removing the electrical connections and fixing back the new LED aviation obstruction light at same in position with necessary modifications / PCC work and as desired by the Engr-in-Charge to make the fittings in smooth serviceable condition and testing and making good the disturbed complete and as directed. Note : (i) Replacement of aviation obstruction light shall be measured and paid separately under relavent item as "supply only" (ii) Replacement of cable and saddling down tank shall be measured and paid separately (iii) Necessary climbing arrangements like safety rope sys/Scaffolding/ ladders etc for repairing/removing/refixing the fittings should be included in the quoted rate.
"Supply only" aviation obstruction light, yelow painted, die-cast aluminium alloy housing, built in 75VA step up transformer, heat resistant, clear thick glass and accessories with neon lamp complete all as specified and as directed. Make : Cat No. 020075 BJAOL1 of Bajaj / Havells / Crompton.
S&F in repairs LED street light fitting of capacity 120W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection and impact resistance complete AC 120-300V, 50Hz with lumen 12600 with CCT 5700 and PF >0.95, surge protection >5KV and THD <10%, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . Make : SPOR120C0811 of Century/Jaquar/Phillips/Havells (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor) (Necessary excavation, PCC work, Bracket, Connecting wire will be measured and paid separately under relavent items)
S&F in repairs LED street light fitting of capacity 90W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection and impact resistance complete AC 120-300V, 50Hz with lumen 9900 with CCT 5700 and PF >0.95, surge protection >5KV and THD <10%, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . Make : SPOR090C0801 of Century/Jaquar/Phillips/Havells (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor) (Necessary excavation, PCC work, Bracket, Connecting wire will be measured and paid separately under relavent items)
S&F in repairs LED street light fitting of capacity 70/75W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection and impact resistance complete AC 120-300V, 50Hz with lumen 7920 with CCT 5700 and PF >0.95, surge protection >5KV and THD <10%, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . Make : SPOR072C0807 of Century/Jaquar/Phillips/Havells (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor) (Necessary excavation, PCC work, Bracket, Connecting wire will be measured and paid separately under relavent items)
S&F in repairs LED street light fitting of capacity 60W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection and impact resistance complete AC 120-300V, 50Hz with lumen 6600 with CCT 5700 and PF >0.95, surge protection >5KV and THD <10%, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . Make : SPOR060C0805 of Century /Jaquar/Phillips/Havells (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor) (Necessary excavation, PCC work, Bracket, Connecting wire will be measured and paid separately under relavent items)
S&F in repairs LED street light fitting of capacity 45/50W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection and impact resistance of IK07, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location complete all as specified and as directed. . Make : SPBL046C2126 of Century/Jaquar/Phillips/Havells (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor) (Necessary excavation, PCC work, Bracket, Connecting wire will be measured and paid separately under relavent items)
S&F in repairs integral compact wide beam high performance LED flood light luminaire with IP 66 protection, tampered protective toughened glass cover, thermal shock impact resistance cover, epoxy black powder coated finish, high purity , 200W LED of luminous efficiency greater than >120 Lm/watt with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium/Copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and directed. Make : JETA IRIS FLS200WLED757APWBLTG of Havells/Jaquar/Phillips/CENTURY LED
S&F in repairs integral compact wide beam high performance LED flood light luminaire with IP 66 protection, tampered protective toughened glass cover, thermal shock impact resistance cover, epoxy black powder coated finish, high purity , 100W LED of luminous efficiency greater than >120 Lm/watt with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium/Copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and directed. Make :- JETA IRIS FLS100WLED757APWBLTG of Havells /Jaquar/Phillips/CENTURY LED
M&L in repairs earthing with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing inclduing taking down old one complete all as specified and as directed.
Surface dressing of installation/sub station area by removing of grass, creepers, etc. from roof of the building, in fencing and surrounding area of installation building complete all as specified and as directed.
Prunning of tree not exceeding 10mm girth including cutting of trunk branbches and stacking of servicerable meterial and disposal of unserviceabl materials to a disatnce not exceeding 50 m and clearing complete all as specified and as directed.
Prunning of tree not exceeding 15mm girth including cutting of trunk branbches and stacking of servicerable meterial and disposal of unserviceabl materials to a disatnce not exceeding 50 m and clearing complete all as specified and as directed.
Prunning of tree not exceeding 20mm girth including cutting of trunk branbches and stacking of servicerable meterial and disposal of unserviceabl materials to a disatnce not exceeding 50 m and clearing complete all as specified and as directed.
Prunning of tree not exceeding 25mm girth including cutting of trunk branbches and stacking of servicerable meterial and disposal of unserviceabl materials to a disatnce not exceeding 50 m and clearing complete all as specified and as directed.
M&L in repairs machine pressed precast conctete interlocking paver block, glossy finish of approved colour, design & shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed.
Dismantling old/unserviceable chain link fencing any size any mesh incluidng flat iron fillets and MS rod complete complete all as specified and as directed.
S&F for 4mm dia PVC coated chain link fencing of size 120x110mm mesh, made up into matresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and as directed.
M&L for TMT bar 6mm/10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping as in tie bar for fixing of chain link fencing complete all as specified and as directed.
S&F for mild steel screw bolts of 11 to 15mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 10cm and not exceeding 15cm long complete all as specified and as directed.
M&L in replacement of mild steel flat iron fillets for securing wire mesh etc. including all necessary drilling or riveting etc. and similar work conforming to Fe 290 (Gde E-165) complete all as specified and as directed.
ms singh construction
Garg Brothers
M/s PRABIR ENTERPRISE
MAA COMMUNICATION
M/S S. P. ENTERPRISE
STANDARD ELECTRIC WINDERS
FREEZCON
MAZUMDAR ENTERPRISE
NChetia and Sons Trading
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .