| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC | ₹3.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹3.8 L+₹7,445.27 (2.01%)Rejected-AOC HALDERPARA JOTE SHIBRAMPUR MAHESHTALA KOLKATA WEST BENGAL 700141 | 24 PARAGANAS SOUTH | WEST BENGAL | 700141 | ₹3.8 L+₹7,445.27 (2.01%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.8 L+₹11,112.34 (3.00%)Rejected-AOC 159 KAILASH GHOSHI ROAD KOLKATA WEST BENGAL 700008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | ₹3.8 L+₹11,112.34 (3.00%) | L3 | Rejected-AOC L3 |
Tender Value
₹3.7 L
EMD Value
₹7,450
Closing Date
3 Jun 2026, 2:00 pmClosed
Executive Engineer (MGPS WPS)
Mullick Ghat Pumping Station, 67/5 Strand Road, Kolkata-7
REPAIRING, OVERHAULING AND HEAT VARNISHING OF STATOR AND ROTOR WITH NECESSARY TESTING AND COMMISSIONING OF 580 BHP H.T. MOTOR UNIT NO. 2 AT MULLICK GHAT PUMPING STATION
2026_KMC_1025048_1
KMC/WS/MGPS/02/2026-27
Open Tender
ELECTRICAL WORKS M/R
Percentage
30 days
Mullick Ghat Pumping Station, 67/5, Strand Road
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹7,450
Yes
9 Sept 2026
21 May 2026
5 Jun 2026
21 May 2026
3 Jun 2026
21 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | DEMOUNTING THE MOTOR FROM SOLE PLATE & PLACING THE SAME ON AVAILABLE WORKING FLOOR BY USING THE DEPARTMENTAL OVERHEAD CRANE ETC.WHICH INVOLVES DISCONNECTION OF HT/LT CABLE FROM MOTOR TERMINALS CAPACITOR TERMINALS, SPACE HEATER TERMINALS ETC & DECOUPLING THE MOTOR FROM PUMP WITH CARE & CAUTION & COMPLETEIN ALL RESPECT AS PER DIRECTION OF EIC
(MODE OF MEASURMENT-WEIGHT OF MOTOR WITH COUPLING | 1 | MATRIC TON | 13,000 | ₹12,987 |
| 2 | TAKING OUT THE ROTOR FROM THE STATOR THROUGH DISMANTLING THE MOTOR WHICH INVOLVES DISCONNECTION OF HT/LT CABLE FROM THE MOTOR TERMINALS SPACE HEATER TERMINALS ETC.,DECOUPLING THE MOTOR FROM PUMP, SEPARATION OF BALL/ROLLER BEARINGS FROM THE DE AND NDE. DISPLACEMENT OF MOTOR FROM THE SOLE
PLATE, SEPARATION OF ROTOR FROM THE STATOR AFTER NECESSARY MEASURMENT AND DEMARCATION AND PLACING AT THE WORKING FLOOR BY USING THE DEPARTMENTAL OVERHEAD CRANE COMPLETE CAREFULLY AS PER DIRECTIONOF EIC (MODE OF MEASURMENT -WEIGHT OF THE ROTOR WITH HALF COUPLING) | 1 | MATRIC TON | 15,000 | ₹14,985 |
| 3 | THOROUGH CLEANING THE 6KV RATED STATOR SLOT FROM DUST DRIFT LOOSE PARTICLE ETC AND DRYING THE STATOR SLOTS COMPLETE CAREFULLY AS PER DIRECTION OF EIC (HOT-SPOT TEST TO BE CARRIED OUT FOR CHECKING OF HEALTHINESS OF STATOR CORE )(MODE OF
MEASURMENT-MEASURED SURFACE INNER AREA (I.E STATOR CORE INNER DIA.X LENGTH OF CORE) OF THE CORE OF THE COMPLETE | - | SQUARE METER | 35,000 | - |
| 4 | HEAT VERNISHING THE 6KV. RATED STATOR WINDING WITH TWO COATS OF DR. BECK HTF-50 VERNISH AND SUBSEQUENT HEATING TO SUITABLE TEMPERATURE TILL REQUSITE RESULT IS OBTAINED TO THE SATISFACTORY IRVALUE, PI VALUE, INDUCTANCE / RESISTANCE MEASUREMENT & HIGH VOLTAGE TEST & COMPLETE IN ALL RESPECT WITH PROPER CARE & CAUTION AS PER DIRECTION OF EIC (ALL TEST
CERTIFICATES TO BE FURNISHED ) (MODE OF MEASUREMENT -MEASURED SURFACE INNER AREA {I.E STATOR CORE INNER DIA.X H X LENGTH OF CORE } OF THE CORE OF THE COMPLETE STATOR ). | - | SQUARE METER | 12,000 | - |
| 5 | DUSTING OFF THE ROTOR OF 6KV RATED MOTOR BY SUITABLE BRUSH AND MIST FREE GAS(OXYGEN ) CLEAN DRY AIR JETTING ARRANGEMENT ( PRESSUR IS NOT SO HIGH AS TO DAMAGE THE INSULATION ) AND FOLLOWING SUBSEQUENT HEATING AND CLEANING WITH PETROLEUM
BASED SUITABLE ORGANIC COMPOUND THOROUGHLY ETC COMPLETE AS PER DIRECTION OF EIC ( MODE OF MEASUREMENT -MEASURED SURFACE PERIMETER OF THE ROTOR AREA { I.E. CORE OUTER DIA. X H X LENGTH OF CORE } OF THE COMPLETE ROTOR ) | - | SQUARE METER | 22,000 | - |
| 6 | HEAT VERNISHING OF THE ROTOR OF THE 6KV RATED MOTOR WITH TWO COATS OF DR. BECK HTP-50 VERNISH AND SUBSEQUENT HEATING TO SUITABLE TEMPERATURE TILL REQUSITE RESULT IS OBTAINED & COMPLETE IN ALL RESPECT WITH PROPER CARE & CAUTION AS DIRECTION OF EIC ( MODE OF MEASUREMENT-MEASURED SURFACE
PERIMETER OF THE ROTOR AREA { I.E CORE OUTERDIA X H X LENGTH OF CORE } OF THE COMPLETE ROTOR. | - | SQUARE METER | 10,000 | - |
| 7 | ASSEMEMBLING THE 6KV RATED MOTOR AFTER INSURTING THE ROTOR INTO STATOR INCLUDING FITTING OF BEARING (BALL OR ROLLER) FOR BOTH DE & NDE ETC MAINTAINING THE PROPER ""AIR GAP"" AND PLACING THE ASSEMBLED MOTOR ON THE SOLE PLATE BY UTILIZING THE OVER HEAD CRANES AVAILABLE IN THE PUMPING STATION .TIGHTENING THE FOUNDATION BOLT FIXING THE DOWELLS PINS & COMPLETE IN ALL RESPECT AS PER DIRECTION OF EIC (MODE OF MEASUREMENT- GROSS WEIGHT OF THE MOTOR ) | 1 | MATRIC TON | 18,000 | ₹17,982 |
| 8 | MAKING ALIGNMENT OF THE SHAFT OF PUMP & MOTOR BY USING DIGAUGE ETC INCLUDING INSERTION OF REQUSITE DIMENTIONED BRASS SHEET & COMPLETE IN ALL RESPECT AS PER DIRECTION OF EIC. | 1 | MATRIC TON | 22,000 | ₹21,978 |
| 9 | MAKING HT CONNECTION OF MOTOR TERMINALS WITH ALL EXISTING CABLES SUCH ASFROM FEEDER BREAKER /CAPACITOR /SOFT STARTER & LT CONNECTION OF ALL EXISTING MOTOR SPACE HEATER/ MOTOR TEMPARATURE SCANNER & EARTHING TERMINALS ETC COMPLETE IN ALL RESPECT AS PER DIRECTION OF EIC. | - | ITEM | 12,000 | - |
| 10 | STATUTORY REQUISITE PRE-COMMISSIONING HIGH VOLTAGE TEST OF THE 6KV RATED MOTOR TO BE DONE BY THE PARTY ENGAGING AUTHORIZED AGENCY OF DIRECTORATE OF ELECTRICITY ,GOVT. OF W.B. AND THE TEST CERTIFICATES TO BE FURNISHED TO THE DEPARTMENT | - | ITEM | 13,000 | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.11 MB
BOQ_2518892.xls
BOQ • 0.29 MB
Technical.pdf
Tender Documents • 1.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .