GE AF TECH AREA AGRA
GE AF TECH AREA AGRA
COMPREHENSIVE MAINT OF FIRE FIGHTING AND FIRE HYDRANT SYSTEM OF NEW ATC AWACS 50 SQN PP AND RS POD COMPLEX AND REPAIR TO FIRE ALARM SYSTEM OF TECH AREA UNDER GE AF TECH AREA AGRA
2024_MES_669410_1
8200-1604/E8
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF TECH AREA AGRA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF TECH AREA AGRA
₹70,000
Yes
29 Jan 2025
31 Aug 2024
30 Sept 2024
31 Aug 2024
28 Sept 2024
14 Sept 2024
1 Sept 2024 - 7 Sept 2024
Amount
M&L for comprehensive monthly maintenance of auto fire alarm system installed at Annex 'A', 'B' , & 'C' of 50 SQN in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel- 03 No. (b) Multi-criteria fire detector with base- 130 Nos. (c) Fire Alarm Hooters-12 Nos (d) Fire alarm response Indicators-40 Nos (e) Fire alarm Manual call Point-12 Nos.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at Annex 'D', & 'E' of 50 SQN in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel - 02 No. (b) Multi-criteria fire detector with base- 105 Nos. (c) Fire Alarm Hooters-08 Nos (d) Fire alarm response Indicators-36 Nos (e) Fire alarm Manual call Point-08 Nos.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at 251 SU in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Microprocessor based fire alarm detection system 08 loop fire alarm panel- 01 No. (b) Multi-criteria fire detector with base- 30 Nos. (c) Fire Alarm Hooters-05 Nos (d) Fire alarm response Indicators-04 Nos (e) Fire alarm Manual call Point-05 Nos.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at New ATC in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Microprocessor based fire alarm detection system 16 loop fire alarm panel- 01 No (b) Multi-criteria fire detector with base- 116 Nos. (c) Fire Alarm Hooters-07 Nos (d) Fire alarm response Indicators-79 Nos (e) Fire alarm Manual call Point-07 Nos.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at POD section in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Microprocessor based fire alarm detection system 4 zone fire alarm panel- 01 No (b) Multi-criteria fire detector with base- 30 Nos. (c) Fire Alarm Hooters-03 Nos (d) Fire alarm response Indicators-30 Nos (e) Fire alarm Manual call Point-01 Nos.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at SRE Bldg in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Microprocessor based fire alarm detection system 04 Zone fire alarm panel - 02 No. (b) Multi-criteria fire detector with base- 130 Nos. (c) Fire Alarm Hooters-12 Nos (d) Fire alarm response Indicators-40 Nos (e) Fire alarm Manual call Point-12 Nos.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at GCA Building in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Microprocessor based fire alarm detection system 08 loop fire alarm panel- 01 No. (b) Multi-criteria fire detector with base- 36 Nos. (c) Fire Alarm Hooters-04 Nos (d) Fire alarm response Indicators-04 Nos (e) Fire alarm Manual call Point-04 Nos.
M&L for comprehensive monthly maintenance of auto fire alarm system installed at Hangar No-04, POL Store, Adwitya -1 ,Adwitya -2,Adwitya -3 of 50 Sqn in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Microprocessor based fire alarm detection system 16 loop fire alarm panel- 05 No (b) Beam fire detector - 04 Nos. (c) Fire Alarm Hooters -16 Nos (d) Flame fire detector - 04 Nos (e) Fire alarm Manual call Point-22 Nos. (f) Multi-criteria fire detector with base- 12 Nos. (g) Fire alarm response indicators - 04 Nos
M&L for comprehensive monthly maintenance of auto fire alarm system installed at PP&RS building 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Microprocessor based fire alarm detection system 16, Zone fire alarm panel- 01 No (b) Fire Alarm Hooters -10 Nos (c ) Smoke detector - 65Nos (d) Fire alarm Manual call Point-10 Nos. (e) Fire alarm response indicators - 05 Nos "Notes For Ser Item No 01 to 09 :- (i) Cleaning inspecting, checking and repairing the detective parts by replacement of all the equipments of fire detection system. (ii) 100% operational of all the equipment of fire detection system shall be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. (vii) Testing of the entire fire detection and alarm system shall be carried out and report shall be submited regardinding functioning of the system complete all as specified and directed by Engr-in-charge. "
S&F lead acid battery of 12 Volt, 7 AH complete all as specified and directed. Make: EXIDE (CHLORIDE)/ AMCO / AMARON
S&F low intensity hooter/siren electronic type horizontal two stage continuoas normal operation for atleast 50 minutes with sound level 65db to 120 db measured at 1.5m with sound output variation of +5db , 500m range. for warning of fire connected with central contol panel installed in each zone inside the rooms complete all as specified and directed. Make : Agani /NSD/ System sensor
S&F optical type smoke detector supply voltage 9 to 33 V DC ,UL/FM/LPC approved with junction box and base with self built intelligence as per IS 11360 to be fixed inside test rig with suitable fixing arrangement complete all as specified and directed. Make:-Apollo/system senser/Siemens
S&F remote response indicator complete all as specified and directed. MAKE : MOORLEY / APPOLLO / SIEMENS / AOREYWELL
S&F PVC insulated and sheathed FRLS type armoured copper conductor cable of size 1.5 Sqmm 2 core complete all as specified and directed.
Supply and fix 4 zone microprocessor based fully analog addressable type fire alarm repeater panel complying with BS EN 54 single loop of capacity from 99 detectors & 99 modules upto 200 detector and module complete all as specified and directed. Make: Honeywell/APOLLO/Siemens/Moorley Note :- Panel should be match with existing system.
Supply and fix fire alarm main control panel microprocessor based addressable for 2 wire communication with detectors and modules and addressable response indicators together with mimic diagram made on Auto CAD and pastedon Acrylic sheet with datalogging facility and 2 x16 character LCD, confirming to IS : 2189 complete with PA based evacation system and having its own mains/standby power supply with batteries etc. The panel shall also have an Auto dialling facility and potential free NO & NC contacts and a 80 watts PA amplifier. The Panel shall have a capacity of 12 loops complete all as specified and directed. Honeywell/APOLLO/Siemens/Moorley Note :- Panel shall be match with existing system
S&F external Siren 2 KM range with control panel complete all as specified and directed. Make: Kheraj / KPT / National / System senser
M&L for repairing, servicing and overhauling of Diesel Engine Driven Fire Pump suitable for automatic operation of capacity 55HP, 1500 RPM including checking of condition and making serviceable of engine compression, exhaust system, tappet mechanism, lubricating system, cooling system, including replacement of oil filter, fuel filter, air filter and any other associated filter and protecting accessories all sorts of oil leak age by renewal of necessary gasket, replacement of engine oil, chekcing and making alignment of engine with pump ,cleaning of fuel tank and fuel line etc including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop including loading/unloading for necessary repairs such as remetaling, turning of Pump shaft, bearing case of suction & delivery and replacement of impeller, stage bush, alongwith renewal of unserviceable minor parts, with new spare parts, carrying back from workshop, re-installation of the Pump set all as specified all as specified and directed. Make : Kirloskar.
M&L for repairing, servicing and overhauling of electric induction motor driven Fire Pump suitable for automatic operation of capacity 60HP, 1500 RPM 3 Phase 415 Volt, 15 HHZ discharge appx 1620 LPM at 70 Mtr head multi-stage including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop incl loading/unloading for necessary repairs such as remetaling, turning of Pump shaft, bearing case of suction & delivery and replacement of impeller, stage bush, alongwith replacement of unserviceable minor parts, with new spare parts, carrying back from workshop, re-installation of the Pump set complete with existing motor alongwith proper coupling and alignment, complete all as specified and directed. MAKE : Kirloskar
M&L for repairing, servicing and overhauling of Jockey pump 15 HP, centrifugal Pump and Squrrel Cage induction Motor 15 HP, 2900 RPM 3 Phase 415 Volt, 15 HHZ discharge appx 180 LPM at 70 Mtr head, multi-stage including disconnecting and refixing of Suction and delivery pipe, and transporting to work shop incl loading/unloading for necessary repairs such as remetaling, turning of Pump shaft, bearing case of suction & delivery and replacement of impeller, stage bush, alongwith replacement of unserviceable minor parts, with new spare parts, carrying back from workshop, re-installation of the Pump set with existing motor alongwith proper coupling and alignment, complete all as specified and directed. MAKE : Kirloskar. .
M&L For rewinding the jockey pump of 15HP capacity by disconnecting the electrical connections and transporting the work shop and back after rewinding the same by adequate size/guage of copper wire with insulating materials and varnishing the winding and all as specified and directed.
M&L for comprehensive monthly maintenance of fire fighting and fire hydrant system installed at 50 Squadron in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Electriclal motor driven fire pump of 55 HP- 01 No (b) Disel engine driven fire pump of capacity 55 HP - 01 Nos. (c) Electrical motor driven jockey pump 15 HP - 01 Nos (d) Electriclal control panel for fire fighting system - 01 Nos (e) MS Pipes 150mm dia-3200 RM (f) 63mm dia gumetal landing valve-44 Nos (g) CI sluice valve 150mm-15 Nos (h) Non return valve (NRV) 150mm dia- 15 Nos (j) Butterfly valve 80mm - 33 Nos. (k) Periodical checking and servicing of 63mm dia fire hose pipe 88 Nos at every month , opening and applying the chalk powder and ensuring the no leakage at hose and keeping safely in hose container.
M&L for comprehensive monthly maintenance of fire fighting and fire hydrant system installed at ATC Building in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Electriclal motor driven fire pump of 55 HP capacity- 01 No (b) Disel engine driven fire pump of capacity 55 HP - 01 Nos. (c) Electrical motor driven jockey pump 15 HP - 01 Nos(d) Electriclal control panel for fire fighting system - 01 Nos (e) MS Pipes 150mm dia-3200 RM (f) 63mm dia gumetal landing valve-44 Nos (g) CI sluice valve 150mm-15 Nos (h) Non return valve (NRV) 150mm dia- 15 Nos (j) Butterfly valve 80mm - 33 Nos. (k) Periodical checking and servicing of 63mm dia fire hose pipe 88 Nos at every month , opening and applying the chalk powder and ensuring the no leakage at hose and keeping safely in hose container
M&L for comprehensive monthly maintenance of fire fighting and fire hydrant system installed at PP&RS in 4 wing ,Tech Area at AF Stn Agra.The detail scope of work consists of the following:- (a) Electriclal motor driven fire pump of capacity 55 HP - 01 No (b) Disel engine driven fire pump of capacity 55 HP - 01 Nos. (c ) Electrical operated motor squirrel cage induction motor 5 HP terrus motor for Fire Alarm system -01 No. (d) Electrical operated submersible pump 5 HP capacity -0-1 No. (e) Electrical motor driven jockey pump 15 HP - 01 Nos (f) Electriclal control panel for fire fighting system - 01 Nos (g) MS Pipes 150mm dia-300 RM (h) 63mm dia gumetal landing valve-06 Nos (j) CI sluice valve 150mm dia-08 Nos (k) Non return valve (NRV) 150mm dia- 06 Nos (l) Butterfly valve 80mm dia - 08 Nos. (m) Periodical checking and servicing of 63mm dia fire hose pipe 12 Nos at every month , opening and applying the chalk powder and ensuring the no leakage at hose and keeping safely in hose container.
Notes for Item No 22 to 24 :- (i) Cleaning, inspecting, checking and trial run of all the equipments of fire fighting system. (ii) 100% operational of all the equipment of fire fighting system should be maintained at all time. (iii) The contractor will submit Monthly inspection report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out through experienced technician. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Spare parts required for replacement will be measured and paid separately under respective items of this schedule. (vii) Testing and trial run of the entire fire fighting and fire hydrant system and servicing the all pump sets and all rotor parts of pumps by applying the lubricants as per OEM recommandations and all eqpts servicing report shall be carried out and report shall be submited regarding functioning of the system complete all as specified and directed by Engr-in-charge.
Taking up or down old MS pipe with all fitting from trenches in any length from site etc complete all as specified and directed for the following sizes :-
(a) 150 mm dia
(b) 80 mm dia
Supply, laying, jointing, testing and commissioning of ISI marked MS ERW pips heavy duly welded the joints with and including specials etc like bends, tees, reducers, flanges etc. including all supports and coating with anticorrosive paint etc., providing tapping for pressure guage and other instruments, making holes/chasing in wall/ RCC slab if required, including making good the same as original complete all as specified and directed for the following sizes:-.
(a) 150 mm dia
(b) 100 mm dia
Excavating in trenches in soft/loose soil n.exc 1.5M wide and n.exc 1.5M in depth for foundation, laying pipes, cables etc n.exc 10Sqm on plan and getting out in soft/loose soil etc complete all as specified and directed.
M&L for returning, filling in soft/loose soil including spreading, leveling watering and well ramming in layers n.exc 25 cm etc complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point etc complete all as specified and as directed..
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate after laying the pipe complete and matching with the surroundings etc complete all as specified and directed.
Supply & installation, testing and commissioning in renewal of ISI marked single headed 63mm dia gunmetal landing Valve, flanged inlet with 63mm dia female intantaneous outlet confirming to IS 5290 on the fire wet riser/down comer including making 80NB pipe connection with riser fixing the landing valves including MS nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect complete all as specified and directed. Make : Firex / Safex / Minimax / kartar
Supply and fixing in replacement of ISI marked cast iron double flanged sluice valve of 150mm dia rising type stainless steel spindle as per IS : 13095, PN 1.6 class including MS nuts, bolts, gaskets, flanges & washers etc and testing complete all as specified and directed.Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana.
Supply and fixing in replacement ISI marked cast iron double flanged Non Return valve 150mm dia as per IS : 5312, part I including MS nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana
Supply and fixing in replacement ISI marked cast iron double flanged Non Return valve 100mm dia as per IS : 5312, part I including MS nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana
Supply, fixing ,testing & commissioning in renewal 100mm dia Butterfly valve ISI marked including MS nuts, bolts gaskets, and washers etc. complete all as specified and directed. Make : Kirloskar/Kartar/Venus/Zaloto/Kalpana
Supply, fixing, testing & commisioning in renewal of 20mm bore and 30 meter long hose (Rubber lined Dunlop pipe) and hose reel drum for first aid fire fighting conforming to IS :5132, with full swing drum, fixing brackets, 5mm dia shut off gun metal nozzle, 32mm dia, hand lever operated ball valve, connecting directly from the riser through 32mm dia GI pipe with GI sockets, elbows, nipple etc. including providing operating instructions on a metal plate and fixing it near hose reel drum. The system shall be complete in all respects complete all as specified and directed. Make : Dunlop / Good year
S&F in renewal gun metal ISI marked 63mm dia instataneous pattern short branch pipes with 20 mm dia Nozzle suitable for interconnections to hose pipe coupling complete all as specified and directed. Make :- Manimax / Firex / Safex / New
S&F in renewal water monitor branch pipe of twisted neck of long nose made by aluminum alloy and cost iron body and having one MS handle, the whole assemble having the flexible neck to rotate 360 degree and including connected accessories and all as specified and directed.
S&F in renewal ISI marked RRL (IS : 636 type II) fire hose pipe 15meter long and 63mm dia with ISI marked (IS : 903) gun metal male and female coupling complete all as specified and directed.
Supply and fix Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of 4 way 63mm dia instantaneous type male coupling with built in check valves 150mm dia, flanged outlet complete with all accessories complete all as specified and directed
Supply & fixing in renewal Pressure Switch universal type complete all as specified and directed.
Supply & fixing in renewal dial type Pressure gauge with isolation cock at hydrant station of dial type 150 mm dia and calibration 0-10 Kg/Sqcm complete all as specified and directed.
Supply and fixing in renewal of weather proof standard fire hose cabinet of size 900mm x 900mm x 600mm outdoor type suitable for accommodating single headed hydrant valve made of not less than 16 SWG MS sheet having central opening glassed door of size 1M X 0.3M (4mm thick clear glass) including necessary locking arrangement with two numbers MS handle of size 150mm for housing, 15 meter long fire hose pipes, branch pipe and hydrant valve as required including painting (Two coats of the fire red colour over one coat primer). The cabinet shall be mounted on brick masonry platform constructed in (brick work with sub class 'B' bricks in CM 1:4 of size 1.2M X 1M and 0.3M height including two coats of white wash over 10 mm thick rendering in CM 1:4) and supported with MS frame made of Angle iron (75X75X6 mm size) as desired. The words "FIRE HOSE" to be painted on the box with one coat of synthetic emamel paint of red colour complete all as specified and directed.
Supply and fix in renewal explosive proof addressable type Manual Call Point break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility and blinking facility complete all as specified and directed.
Supply and fix in repair 24 Volt DC Hooter cum speaker complete in 16 SWG MS enclousre complete all as specified and directed.
Supply and fix in replacement brass body open head type automatic sprinkler water deluge type arrangement) heads setwith detector including fixing arrangement to operate at specified temperature of following types:- (i)Type- pendent type, (ii) Size: 15 mm dia, (iii) Finish: Brass, (iv) Operating temp- 57° C complete all as specified and directed.
Supply and fix in renewal of 15 mm dia surface captive rosette operating temp 57° C
Supply, installed testing in renewal and commissioning of optical beam smoke cum heat multi sensor detector conforming to BS : 5839 Part 5 with base with self built intelligence as per IS 11360 consisting of a transmitter/receiver or reflector, complete all as specified and directed. Make : System Sensor or equivalent.
Supply & Fixing in renewal of Battery-12 Volts, 120 Ah complete with initial charging, complete all as specified and directed. Make:- EXIDE (Express)/ AMARON / AMCO
Supply & Fixing in renewal Tubes, 'Medium grade' of size 40mm galvanised in any length with all fitting and fixed complete to walls and ceilings or laid in floors of complete all as specified and directed
Supply & Fixing in renewal Tubes, 'Medium grade' of size 25mm galvanised in any length with all fitting and fixed complete to walls and ceilings or laid in floors of complete all as specified and directed
Supply and fix in renewal wiring with PVC insulated armoured stranded copper conductor cable of size 2.5 sqmm x 3 core, 230 Volt grade, fixed on wall/surface with MS saddles complete all as specified and directed.
Supply and Fix in replacement contactor 3pole 415 volts 100 Amps with operating voltage 440 Volts and fixing on existing LT panel for Fire fighting motor of capacity 60 HP including disconnecting the electrical cionnetions of old one and fixing the new one with proper electrical connection etc complete all as specified and direted.
All as per Ser No.53 above but of capacity 32 Amp
S&F in replacement PVC insulated sheathed armoured copper conductor cable of size 1.5 Sqmm single core FRLS type etc complete all as specified and directed.
S&F in replacement PVC insulated sheathed armoured copper conductor cable of size 4.0 Sqmm single core FRLS type etc complete all as specified and directed.
S&F in replacement PVC insulated sheathed armoured copper conductor cable of size 6.0 Sqmm single core FRLS type etc complete all as specified and directed.
S&F in replacement PVC insulated sheathed armoured copper conductor cable of size 10.0 Sqmm single core FRLS type etc complete all as specified and directed.
M&L for the glow sign board of size 200cmx50cmx20cm made by using 3mm thick arcylic sheet and frame will be manufactured by using MS square tubular bars of suitable size and welded the structure with aluminum beading on joints and the letters will be written by using radium sticker ie FIRE FIGHTING PUMP HPOUSE, and location on both sides will be visible 4Nos of FTL light fitting 36 watt with ballast,4 feet 'length tube rod fixed inside the box and connected with suitable size of twin core twisted flaxible copper wire to connect the supply and including fixing the sign board on top of building with necessary fixing arrangement and all as specified and directed.
M&L for display board/notice board made by using fibre, decorative type and having the aluminum section borders and inside fibre board will have suitable holes for punching the pins of standing orders of any size with and including PVC alphabtic letters and neumericals for changing the date,day etc of size 100cm x50cm with hanging arrangement on wall etc complete all as specified and directed.
S & F in replacement rotational moulded polyethylene water storage tank (cylinderical with closed top) hoisted and fixed in position all as specified in SSR part-I of capacity 1000Ltrs and all as specified and directed.
S & F in replacement rotational moulded polyethylene water storage tank (cylinderical with closed top) hoisted and fixed in position all as specified in SSR part-I of capacity 2000Ltrs and all as specified and directed.
M&L for earthing in replacement with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below normal ground level with top edge of earth plate shall not less than 1.5 mtr below normal ground level and connected to galvanized iron earth, strip of size 25x4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point including PCC pit constructed by using PCC 1:3:6 type CI (using 20mm graded aggregate) with and including angle iron frame 300 x 300mm size, including machine cut Jodhpur stone slab pit cover of size 300x300 mm size with 12mm MS Rod handle for lifting, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work GI protection pipe of 40mm dia medium grade etc complete all as specified and directed by Engr in Chanrge. Note :- (i)The earth pit shall be refilled by boulders free from vegetable soil. (ii) Earthing shall be tested by contactor in presence of JE /Engr-in-Charge. Record shall be maintained. Payment shall be admissible only after satisfactory test results of earthing.
Supply, laying and testing in replacement of XLPE type PVC insulated armoured heavy duty 1100 volts grade electric cable copper conductor with cross sectional area of 10 Sqmm 3 core etc complete all as specified and directed. .
all as per item No 64 above but for cable of size 35 Sqmm 3 core
GUJRAL BUILDERS (BID ID -3105238)
MUKTA AND COMPANY (BID ID -3104198)
Prime Technology (BID ID -3119447)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .