Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.7 L+₹3.8 L (20.3%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L2 | Rejected-Finance L2 | |
| 3 | L3₹22.9 L+₹4.0 L (21.4%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹23.6 L+₹4.7 L (25.0%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L4 | Rejected-Finance L4 | |
| 5 | L5₹33.5 L+₹14.6 L (77.4%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹29.8 L
EMD Value
₹59,600
Closing Date
1 Oct 2020, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
REPAIR/REPLACEMENT OF LT UG CABLE, MCCBs, ACSR CONDUCTORS AND CERTAIN MISC WKS OF ALL OUTPOCKETS UNDER GE DINJAN
2020_MES_361132_2
C/8207/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹59,600
Yes
2 Nov 2020
16 Sept 2020
3 Oct 2020
16 Sept 2020
1 Oct 2020
25 Sept 2020
Amount
Excavation in trenches exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation of poles etc not exc 10 Sqm in plan and getting out in soft /loose soil complete all as specified and as directed.
Excavation in trenches exceeding 1.5 mtr wide and not exceeding 3 mtr depth (beyond the first 1.5 Meter ) for foundation of poles etc not exc 10 Sqm in plan and getting out in soft /loose soil complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point to a distance not exceeding 50 mtrs and depositing where directed to a level not exceeding 1.5 mtr above the starting point all as specified and as directed.
Dismantling of unserviceable broken LT steel pole/RCC pole/Strut any size including demolition of foundation as required and making good disturbed surface complete all as specified and as directed. Note : Earth work wherever invloved shall be measured and paid separately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 Sqmm 2 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 2 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 Sqmm 3.5 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core including taking out old cable complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately)
M&L for stay assembly complete with all accessories as shown in electrical plate No 1 of MES Schedule Part I dia of stay rod 20mm with and including 7/4 mm galvanised stay strand complete including taking down/dismantling existing stay assembly complete all as specified and as directed. Note : Loop insulator, excavation & earthwork and cement concrete measured and paid separately under relevant items.
Dismantling of cross arms of MS channel or angle sections etc complete and setting aside serviceable materials for reuse within 50 mtrs and keeping in safe custody complete all as specified and as directed.
M&L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Dismantling of insulators (Pin/Shackle/Loop) from LT poles of any size and type and setting aside for reuse and unservicable removing from site complete all as specified and as directed.
M&L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 100 mm height 65 mm dia suitable for 1100 volts grade complete all as specified and as directed.
M&L for shackle type porcelain, insulator vitreous, white, brown or green, including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115 mm dia, size of strap 31 mm x 5 mm and dia of bolt 14 mm suitable for 1100 volts complete all as specified and as directed.
M&L for loop type insulator, vitreous porcelain, white, brown or green of overall dimension 90x140 mm, clearance of hole 25.5 mm complete all as specified and as directed.
M&L for plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B-1, (using 20mm graded stone aggregate) for coping of poles and stay including necessary form work complete all as specified and as directed.
Dismantling/taking down old aluminium conductor steel reinforced (ACSR) conductor of any size from HT/LT overhead line including all jumper etc and keeping serviceable materials in safe custody for reuse etc complete all as specified and as directed.
S&F for aluminium conductor steel reinforced (ACSR) conductor of size 1 of 6/1x2.11 mm (Squirrel) or as required at site including binding, straining in HT/LT overhead line including all jumper connection and binding on insulator with new wire complete all as specified and as directed.
Fixing only, straining and tightening of of old ACSR conductor obtained from item No. 28 above including all arangement/binding wire 2 mm dia, and ACSR jumpers complete all as specified and as directed.
Dismantling existing unserviceable GI earth wire, cradles of any type obtained from service feeder or distributor span complete all as specified and as directed.
M&L galvanised steel earth wire 4 mm dia (hexagonal/rectangular) used for craddle guarding suitable for LT/HT over head line etc all as directed.
S&F for PVC/fibre separator for LT over head line 1100 volts conductor 3/4 wire system for horizontal two Nos, in span including taking down old separator complete all as specified and as directed.
Supply and Laying well burnt bricks, sub class 'B' bricks laid breath wise along length of cable in trenches for cable protection laid for UG cable protection complete all as specified and as directed.
M&L for sand cushioning for protection of cable (below, above and around the cable laid in trenches) all as specified and as directed.
M&L for horizantal boring/drilling hole by machines/mannual under the road in soft/loose soil without cutting/disturbing the existing road and inserting GI pipe 80/50/40mm bore for drawing the cables complete all as specified and as directed . Note : (i) Cost of acessories required for making hole/bore deemed to be included in the quoted rate. (ii) GI pipe shall be measured and paid separately.
M&L for galvanised iron tube light grade 80 mm bore laid in trenches/road/drain/wall alongwith all fittings complete all as specified and directed with MS clamp and nut bolts and washers etc, including taking down old GI tubing alongwith all fixing accessories complete all as specified and as directed.
M&L for galvanised iron tube light grade 50 mm bore laid in trenches/road/drain/wall alongwith all fittings complete all as specified and directed with MS clamp and nut bolts and washers etc, including taking down old GI tubing alongwith all fixing accessories complete all as specified and as directed.
M&L for galvanised iron tube light grade 40 mm bore laid in trenches/road/drain/wall alongwith all fittings complete all as specified and directed with MS clamp and nut bolts and washers etc, including taking down old GI tubing alongwith all fixing accessories complete all as specified and as directed.
M&L for galvanised iron tube light grade 32 mm bore laid in trenches/road/drain/wall alongwith all fittings complete all as specified and directed with MS clamp and nut bolts and washers etc, including taking down old GI tubing alongwith all fixing accessories complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 mtrs, below normal ground level, connected to galvanised earth strip of size 32 x 6 mm as main earthing lead by means of bolts, nuts, washers and check nuts of GI or steel soldered including 40 mm dia light grade galvanised iron pipe for protection of earth lead and connceted to control board or machinery or as directed including watering pipe of 20 mm bore (light grade) galvanised iron pipe, funnel, wire mesh charocoal or coke and common salt in alternate layer all around the earth electrode compacted thickness 15 cm thick with concrete earthing pit in PCC 1:3:6 type C1, 50 mm thick precast RCC 1:2:4 type B1 cover slab (size 300x300x50mm) set in cement morter (1:4) reinforced with 8mm dia TMT bars @ 15cm C/C and suitable size of handle of 10 mm dia MS round bars including earth work in excavation as required, in soft/loose soil, returning filling in and disposal of soil to a distance not exceeding 50 m complete and testing on completion, all as shown on electrical plate No 3 of SSR 2009 Part -I completed all as specified and directed including taking out old unserviceable earthing pit complete all as specified and as directed.
S&F in replacement of CT as per existing ratio at site as suitably fixed in existing ammeater and voltmeter of LT electrical pannel at site complete all as specified and as directed.
Trimming of tree branches around the overhead conductor, poles and stays (not less than 3 metre) to clear the approach of overhead lines including removing of nest, wild grass creepers, unwanted vegetation, etc from pole/stay including clearing of creeoers climbed on poles and angles, channels and disposed off from site beynd 50m and upto a total distance of 250m complete all as specified and as directed by the Engr-in-Charge. Note : Span of 30 to 50m shall be considered as one unit.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including painting (aluminium paint) and writing pole serial number using paint in white colour on black backgound, complete all as specified and as directed. Note : Excavation and Earth work shall be measured and apid separately.
Dismanting of LT lightning arresters any type/size of any capacity with all fittings complete all as specified and as directed.
M&L for LT lighting arresters for outdoor, use, non-linear resistor type, horn gap and choking coil, maximum working pressure 1100 volts complete all as specified and as directed.
M&L for service connection cable 1100 V graded heavy duty cavble with PVC insulated standard aluminium conductor served with an inner seathing of PVC tape armoured wirth galvanised steel wire or tape and overall PVC sheathed 2 core standard conducvtor of 6 Sqmm nominal cross sectional area incl taking down old one complete all as specified and as directed.
M&L for service connection cable 1100 V graded heavy duty cavble with PVC insulated standard aluminium conductor served with an inner seathing of PVC tape armoured wirth galvanised steel wire or tape and overall PVC sheathed 2 core standard conducvtor of 10 Sqmm nominal cross sectional area incl taking down old one complete all as specified and as directed.
M & L Preparing of old painted surfaces existing of LT steel tubular pole 9 metre long including MS Clamps, cable protection pipe, bracket fitted with street light fitting etc by scraping old paint with steel wire brush and sand paper/ emery paper and applying one coat of aluminium paint including cross arms, street light bracket etc and making strip up to 1.5 m above ground level by black/yellow paint in alternative layer and numbering of poles by giving Zebra shead with synthetic enamel paint black and yellow combination painting etc all as directed.
S&F in repairs switch fuse unit 200 Amps,TPN, 415 Volt complete all as specified and as directed. Make : Havell's/HPL/L&T
S&F in repairs switch fuse unit 63 Amps, TPN complete all as specified and as directed. Make : Havell's/HPL/L&T
S&F in repairs change over switch 100 Amps, 4 pole complete all as specified and as directed. Make : Cat No. IHCFFE0100 of Havells/L&T/HPL.
S&F in repairs in repairs change over switch 63 Amps, 4 pole complete all as specified and as directed. Make : Cat No. COS463 of HPL/Havells/L&T/Legrand/C&S.
S&F for air terminator, single pointed aluminium rod 12mm dia and 300 mm long complete all as specified and as directed.
S&F for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
S&F in repair test point terminator block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screw complete all as specified and as directed.
S&F for cast iron cable route indicator with embrossing mark as LT cable, circular type 75mm dia duly fixed with suitable MS flat iron member to be embeded in PCC (1:3:6) type C1 block of size 150x150x150mm complete all as specified and as directed.
S&F for 40 watt LED street light fitting in alminium PDC housing, toughened glass cover with lP65 protection complete all as specified and as directed. Make : Cat No. HPLLEDSL 4060S of HPL /Bajaj/Havells.
Taking down existing old/unserviceable MCCBs of any description from LT panel board complete all as specified and as directed.
S&F for MCCB, AC, 415 Volts, 250 Amp, breaking capacity 25 KA, 4 Pole, with fixed thermal and fixed magnetic setting fixed with LT panel board complete all as specified and as directed. Make : Cat No. TABBASIX2250C4P of HPL/Havells/Legrand/L&T.
S&F for for MCCB, AC, 415 Volts, 200 Amp, breaking capacity 25 KA, 4 Pole, with fixed thermal and fixed magnetic setting fixed with LT panel board complete all as specified and as directed. Make : Cat No. TABBASIX2200C4P of HPL/Havells/Legrand/L&T.
S&F for MCCB, AC, 415 Volts, 160 Amp, breaking capacity 36 KA, 4 Pole, with fixed thermal and fixed magnetic setting fixed with LT panel board complete all as specified and as directed. Make : Cat No. TABBASIX1160N4P of HPL/Havells/Legrand/L&T.
S&F for MCCB, AC, 415 Volts, 125 Amp, breaking capacity 25 KA, 4 Pole, with fixed thermal and fixed magnetic setting fixed with LT panel board complete all as specified and as directed. Make : Cat No. TABBASIX2125C4P of HPL/Havells/Legrand/L&T.
S&F for MCCB, AC, 415 Volts, 100 Amp, breaking capacity 16 KA, 4 Pole, with fixed thermal and fixed magnetic setting fixed with LT panel board complete all as specified and as directed. Make : Cat No TABBASIX1100D4P of HPL/Havells/Legrand/L&T.
S&F for MCCB, AC, 415 Volts, 63 Amp, breaking capacity 16 KA, 4 Pole, with fixed thermal and fixed magnetic setting fixed with LT panel board complete all as specified and as directed. Make : Cat No TABBASIX1063D4P of HPL/Havells/Legrand/L&T.
S&F for MCCB, AC, 415 Volts, 400 Amp, breaking capacity 50 KA, 4 Pole, ices = icu = 100% with fixed thermal and fixed magnetic setting, 70-100% fixed with LT panel board complete all as specified and as directed. Make : Cat part No. TABBASIX3400S4P of HPL/Havells/Legrand/L&T.
S&F for ACB, 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amp, breaking capacity 65 KA, 4 Pole, with sheet metal encloser outdoor type with four leg which can suitabally fixed to this ACB with adiquent space for fixing of two run each incoming & out going cable of size 3.5 core 400sq mm with gland and lug into encloser complete all as specified and as directed. Make : ABB/L&T/Havells.
S&F for MCB, SPN, 240 Volts 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No. 408609 to 408617 of Legrand/L&T/Havells.
S&F in repairs street light bracket arm of length not less than 1.2 m made out of galvansied iron tubing 32mm bore, light grade to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide primer zinc chrome in MS clamp complete all as specified and as directed.
S&F in repairs street light bracket arm of length not less than 1.2 m made out of galvansied iron tubing 40mm bore, light grade to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide primer zinc chrome in MS clamp complete all as specified and as directed.
M&L in repairs earth continuity conductor or main earthinglead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for copper strip of size 25mmx3mm complete all as specified and as directed.
S&F in repairs arth continuity conductor or main earthinglead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for galvanised iron strip 32 x 6 mm complete all as specified and as directed.
S&F for heavy duty long life power capacitor (KVAR) of various capcity as per required at site, 440 volts AC complete all as specififed and as directed. Make : L&T/Havells.
Supply only Water proof/submersible rubber insulation tape complete all as specififed and as directed.
Supply only PVC insulation tape box/packet contain 9.0 m roll each 12 in Nos pack complete all as specififed and as directed. Make : Anchor
M&L for panel reparing and painting only external surfaces of dimension not exceeding 1.8 mx1.4 mx0.6 m to 1.0mx0.9mx0.6 m without taking down pannel accessoriesone and apply two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces including preparation of old surfaces of steel by scrapping, rubbing complete all as specified and as directed.
M&L for panel reparing and painting (both internal and external ) of dimension not exceeding 1.2mx1.0 mx0.6 m with or without taking down pannel accessoriesone and apply two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete including preparation of old surfaces of steel by scrapping, rubbing complete all as specified and as directed. Note : (i) welding, locking arragement of panel and T&P charges included unit quoted rate. (ii) Item required such as MCCB, changeover, ammeter, voltemer and Indicator lamp shall be measered and paid separately.
M&L for panel reparing and painting (both internal and external ) of dimension exceeding 1.0mx0.7mx0.6 m with or without taking down pannel accessoriesone and apply two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete including preparation of old surfaces of steel by scrapping, rubbing and tighting of all electrical connection complete all as specified and as directed. Note : (i) welding, locking arragement of panel and T&P charges included unit quoted rate. (ii) Item required such as MCCB, changeover, ammeter, voltemer and Indicator lamp shall be measered and paid separately.
S&F for indicator lamp set of three of colour Red, Yellow and Blue for LT Panel Board complete all as specified and as directed.
S&F for aviation light luminaries, integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete all as specified and as directed. Make : Cat No. BGAV 302 LED of Bajaj or equivalent as approved by GE.
M/S A K BROTHERS
Salasar Engineering
Construction House
Kaushik Enterprises
FREEZCON
M/S K S Enterprise
M/s GANDHESWAR PHUKAN
STANDARD ELECTRIC WINDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .