| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.2 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC L1 | |
| 2 | L2₹53.5 L+₹1.1 L (2.10%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹57.6 L+₹5.2 L (9.99%)Rejected-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L3 | Rejected-AOC L3 |
Tender Value
₹48.4 L
EMD Value
₹96,900
Closing Date
13 Dec 2021, 6:00 pmClosed
SH A P SINGH, IDSE, CWE CHM
HQ CWE CHANDIMANDIR
CA NO CWE/CHM(U)-57/2021-22 SPECIAL REPAIR FOR REPLACEMENT OF BER DECLARED DG SET, PUMP SET WITH MOTOR AND CAR WASHING PUMP UNDER GE (U) CHANDIMANDIR
2021_MES_480561_2
CWE/CHM(U)-57/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE CHANDIMANDIR
CLASS D CAT a(ii)
8 documents required · 8 mandatory
₹500
Yes
GE (U) CHANDIMANDIR
₹96,900
Yes
5 Feb 2022
16 Nov 2021
20 Dec 2021
16 Nov 2021
13 Dec 2021
29 Nov 2021
Amount
Disconnecting electric connections, and removing unserviceable DG set of 200 KVA from its positioning and tranporting to place as directed by Engr-in-charge within the periphery of Chandimandir cantt for safe custody complete all as directed by Engr-in-Charge.
Demolition of existing PCC and removing other items in foundation of old DG set and disposed off the waste material within 50 mtr distance complete all as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of diesel Engine driven generating set of min 200 kVA/160kW capacity, Frequency 50Hz,Noise level >75 , 3 phase, 4 wire, 415 V, 1500 RPM conforming to relevant IS Codes, AC power supply with power factor 0.8 coupled directly to alternator mounted on a common MS base frame with sturdy design complete with integral acoustic enclosure-sound proof canopy (should have silent features as per latest CPCB norms), fuel tank (Capacity 460Ltr) with draw-out/drag-out facility for easy cleaning, SMPS power supply unit of relevant Amperage and Voltage for Battery Charging in case of non-operation for long periods, long life in all weather conditions & for outdoor application/installation, incl battery & standard accessories & AMF Control Panel suitable for 200KVA Genset, DG set shall be installed/fixed on PCC foundation as per manufacturer's instructions Size of foundation Length-4908mm, Width-2308mm, Height-300mm, Microprocessor beased Controller , Graphical LED Display Best in class montoring and dianostic capacity, integrable with AMF , syncronization and communication configurations,
Aesthetically designed, weather and sound resistance enclosure and 5 Years Comprehensive Annual Maintenance Package by OEM/Manufacturer including all consumables (except diesel) and unlimited visits by service engineer all as specified and as directed with following specifications:- (A) ENGINE : Liquid Cooled, electric start, 4 Stroke, min 6 cylinders cold starting, TCI aspirated, compression ignition, totally enclosed diesel engine at 1500 RPM developing min 248 BHP capacity to match min 200 kVA alternator under NTP conditions as per ISO 8528 Part-I with provision of 10% over load for 1 hour in every 12 hours running confirming to IS: 10000/ISO 3046/ BS: 649/ BS: 554 amended up to date:- (i) Dynamically balanced fly wheel or as per manufacturer's standard. (ii) Coolant cooling system complete. (iii) Air cleaner as per manufacturer's standard. (iv) Fuel injectors and fuel pump as per manufacturer's standard. (v) Electronic/ mechanical governor as per manufacturer's standard to maintain engine speed at all conditions of load. (vi) Fuel service tank of minimum 460 Ltr capacity fabricated from MS sheet with draw-out/drag-out facility, inlet outlet connections air vent tap, level indiactor,
MS fuel piping from tank to engine with valves, unions, reducers, flexible hose connections, mounting pedestals, fuel filters incl all as per manufacturer's design. (vii) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce noise level as per CPCB norms. (viii) Battery charging alternator unit along-with SMPS PSU and voltage regulator, suitable for starting. (ix) Gear driven oil pump for lubricating oil, priming of engine bearing, as well as fuel systems as per manufacturer's recommendation. (x) Natually aspirated/turbo charger as per manufacturer's standard. (xi) Lublicaton oil coolers and filters with replaceable elements as per manufacturer's standard. (xv) Engine control panel having digital display complete with :- (aa) Start/stop key switch. (ab) Lubricating oil pressure indication. (ac) Lubricating oil temperature indication. (ad) Water temperature indication. (ae) RPM indication. (af) Engine hours indication. (ag) Battery charging indication (ah) Low lub oil trip indication. (aj) High water temp indication. (ak) Over speed indication. (xvi) Any other item not included/specified but is a standard design of the manufacturer.
(B) ALTERNATOR (i) Alternator of capacity 200 kVA at 1500 RPM, 0.8 lagging power factor, 3Ph, 415 V, 50 Hz, H Class insulated winding, IP-23 protection, Close-direct-coupled, self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel base frame, alternator shall be confirming to IS: 13364, IS: 4722, BS-5000, IEC: 34 and suitable for tropical condition. (ii) Type : Self exited self regulated with automatic voltage regulator (electronic type) (iii) Rating : 200 kVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed : 1500 RPM. (v) System : 415 Volt +/- 5 % AC 3 phase 4 wire 50 Hz. (vi) Connection : 4 wire star connected. (vii) Enclosure : Screen protected drip proof. (viii) Ventilation : Self ventilated. (ix) Anti friction bearings. (x) AVR output voltage within +/- 1% (C) CONTROL PANEL(AMF) The control panel is to be inside canopy and fabricated out of 1.6mm thick CRCA sheet cubicle type totally enclosed, powder coated, IP-53 protection, equipped with MCCB of suitable capacity, voltage metering & safety, frequency meter metering & safety, ampere metering & safety, fuel level gauge in % metering , Lub oil pressure metering, high water temp metering, engine RPM metering, Power metering, Power factor metering, set of suitable CTs, toggle switch, idicating LED lamps , incoming and outgoing terminals all as specified by manufacturer and directed by Engr-in-Charge.
(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) Base frame of sturdy design and necessary reinforcement with built-in diesel tank as per manufacturer's standard. (i) Fuel tank of sheet metal complete with drain valve, air vent, inlet, outlet connections, and mechanical gauge. (ii) Two number of battery 12V charged with connecting leads of suitable capacity as per manufacturer's standard. (iii) Fuel tank should be of draw-out/drag-out facility for easy cleanout. (iv) SMPS PSU for battery charging in case of non-running of DG set for long periods. (v) 5 Years comprehensive Annual Maintenance Package by OEM/Manufacturer including consumables and unlimited visits by service engineer. NOTE :- (i) The quoted rate shall be inclusive of 05 year comprehensive maintenance. The contractor shall have to submit MOU from OEM of DG set for five years comprehensive maint (ii) The contractor shall submit detailed general arrangement drawing and single line drawing of platform for DG Set as per manufacturer's instruction for Approval of Garrison Engineer.
(iii) The quoted rate shall deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests. (iv) The quoted rate shall deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test. (v) Anything missed out above but technically required for efficient working of DG Set shall deemed to be included in quoted rates. (vi) Design / drawing of the AMF panel & DG SET showing the dimensions is to be obtained from DG SET/ panel board manufacturer / supplier & to be got approved from the GE before placing final order to the manufacturer. (vii) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc can be done of both SEB mains & DG mains. (viii)The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.
Removing old unservicable change over switch and Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole Product type visible of capacity 315 Amps complete all as specified and directed.
Disconnecting electric connections, and removing unserviceable motor and pump from its positioning and keeping in safe custody and depositing to EM-II Store complete all as directed.
Demolition of existing PCC foundation of motor and pump, removing of old nut bolts and angle iron frame including disposal the waste material within 50 mtr distance complete all as specified and directed. Note. Old material retrieved i.e. nut/bolt and MS frame etc shall be considered in credit schedule.
Supply and fixing Pumping sets, centrifugal, electric driven, HP-120, KW-90, Pole-4, RPM-1500, 100 M head ,Mounting-Foot, Type-Squirrel Cage Rotor, Phase-3, Frame size K1-280m, Current-6, Torque-2, Efficiency-94.7, Power Factor-0.9, IP Rating-IP55, Efficiency Grade-IE2, Motors are suitable for voltage 415 V ±10%, frequency 50 Hz ±5%, continuous rating (S1 Duty) with class 'F' insulation suitable for ambient temperature 50 degree C ( temperature rise limited to class B) and altitude of up to 1000 m above MSL , digitally aligned including suitable coupling,Shaft,Pumps as per manufacturer instruction and nuts, bolts and foundation angle iron frame and foundation as per drawing provided by OEM/Manufacturer complete as per manufacturer design complying with following and direction of Engr-in-charge. Motor-KW-90, Pole-4, RPM-1500, Mounting-Foot, Type-Squirrel Cage Rotor, Phase-3, Frame Size-KI-280M, Current-6, Torque-2, Efficiency-94.7, Power Factor-0.9, IP Rating-IP55, Efficiency Grade-IE2, Motors are suitable for voltage 415 V ±10%,
frequency 50 Hz ±5%, continuous rating (S1 Duty) with class 'F' insulation suitable for ambient temperature 50 degree C,Motor shall be Totally Enclosed Fan Cooled type (TEFC).Motor (Driver of pump) shall be energy efficient type as per IS 12615 with up to date amendments. PUMP,SHAFTAND SLEEVE - Pumps that have stable head/capacity curves (continuous head rise to shut-off) of 120 HP driven by electric motor to operate at 1450 rpm The casing has radial suction and delivery. Smooth hydraulic passages ensure high efficiency. The single piece casted phosphor bronze impellers enclosed type casing cast iron type (IS:210). Hydraulically balanced by back vanes or by balancing holes.The impellers should statically and dynamically balanced. Reliable fixing of the impeller on shaft is achieved by using helicoil insert under impeller nut. Pumps shall have suction and discharge flanges designed for same rating. Unless otherwise stated, flanges shall be machined and drilled conforming to ANSI B16.5 standards.Shaft shall be provided with sleeves under the packing/seal and shall be locked to the shaft. The material of sleeve shall be 12 percent chrome steel (hardened). Where the size of pump makes the use of shaft sleeve impracticable, the shaft shall be constructed of 12 percent chrome steel (hardened).Unfiltered vibration velocity for horizontal pumps with antifriction bearing or sleeve bearings when measured at the bearing housing in horizontal or vertical direction shall not exceed 4.0mm/sec (0.16 inch/sec).
All as per item No 7.01, 7.02 here-in-before but 75 HP/55KW coupled with electic motor , discharge min 110 CuMPH, head min 100 Mtr , including suitable coupling as per manufacturer instruction and nuts, bolts and foundation angle iron frame and PCC foundation as per manufacture design complete all as specified and directed by Engineer-in-Charge.
All as per item No 7.01, 7.02 here-in-before but Pumping sets, centrifugal, electric driven 60 HP/45KW, 415 volt, 3 Ph , 50Hz discharge min 90 CuMPH , head min 100 Mtr including suitable coupling as per manufacturer instruction and nuts, bolts and foundation angle iron frame and PCC foundation as per manufacturer design complete all as specified and directed by Engineer-in-Charge.
All as per item No 7.01, 7.02 here-in-before but Pumping sets, centrifugal, electric driven,20 HP/15 KW, 3 Ph, discharge min 175 CuM PH , min Head 20 M coupled with pump including suitable coupling as per manufacturer instruction and nuts, bolts and foundation angle iron frame and PCC foundation as per manufacturer design complete all as specified and directed by Engineer-in-Charge. NOTE for Item No. 7.01 to 10.01 (i) The best efficiency point for the furnished impeller is preferred between the rated point and the normal point. However, in no case the rated point shall be beyond 110 percent of the best efficiency point of the rated impeller. (ii) The maximum permissible sound pressure level of the pump driver train shall not exceed 85 dB measured at 1 meter from pump surface for the recommended range of operation. (iii) For pump, not provided with non-reverse ratchet, OEM shall describe the precaution taken, to prevent damage due to reverse rotation. (iv) Pump-Driver train shall be designed to be suitable for indoor installation with roof.
(v) Lifting lugs/eyehooks shall be provided for ease of lifting of complete pump as well as the Heavy maintenance components of the pump (e.g. Top half casing cover of axially split pump). (vi) The guaranteed parameters shall be demonstrated during shop test without any coating on impellers or casings. (vii) Casing vents along with vent valves, as per manufacturer standards, for all pumps shall be provided. For all horizontal pumps, casing drain with isolation valve and flanged piping terminated at the skid edge shall be provided. Base plate shall also be provided with flanged drain connection. (viii) Unless otherwise specified, all pumps shall be supplied with companion flanges as per existing or directed by Engr-in-Charge with rating Conforming to applicable specification of ANSI, drilled and faced in accordance with pump Suction and discharge flanges along with gaskets and fasteners.For pumps with casing material as cast iron (CI), the companion flanges shall be of slip-on (SO) type [for flange sizes 50mm (2 inches) & above] or socket welded (SW) type [ for flanges of size 15mm (0.5 inches) to 40mm (1.5 inches)] with flat face (FF) & of carbon steel material.The gasket shall be of full face type.
(ix) Unless otherwise specified, the pump shall be supplied with packings. Stuffing box shall have minimum five packing rings plus lantern ring. Packing ring size shall be 3/8" or larger.Balanced mechanical seal with Tungsten carbide/ Tungsten carbide (TC/TC) face combination and Viton as secondary packing along with gland plate and sleeves. (x) Antifriction bearings shall be of standard type and shall meet minimum L-10 rating life of either 25000 hours with continuous operation at rated conditions or 16000 hours at maximum axial and radial loads and rated speed. xi) Material test certificates (chemical and mechanical properties) shall be supplied for impeller, shaft, shaft sleeve, wearing rings and casings. (xii) BASE PLATE: a) Base plate shall extend under the pump, gearbox and motor driver and shall be fully machined for mounting the above equipment. Base plate shall be steel fabricated and shall have sufficient rigidity to avoid vibration and distortion. Base plate shall be so designed as to facilitate proper grouting (Vent holes where required shall be provided).
Base plate shall be cleaned (sand blasted) inside and outside and coated with suitable anticorrosion paint. (b) The base plate shall be provided with lifting lugs for at-least a four-point lift. Lifting the base plate complete with all equipment mounted shall not permanently distort or otherwise damage the base plate or machinery mounted on it. (c) For driver trains , alignment positioning screws shall be provided for each drive element to facilitate longitudinal and transverse horizontal adjustments. The lugs holding these positioning screws shall be attached to the base plate so that they do not interfere with the installation or removal of the drive element. (d) vertical leveling screws, spaced for stability shall be provided on the outside perimeter of the base plate. These shall be numerous enough to carry the weight of the base plate, pump, gearbox (if any) and driver without excessive deflection. (xiii). The pump shall be supplied with a name plate containing the following information: -Purchaser's Item No.-Manufacturer's Name, Type and Serial No Speed, Rated voltage, RPM, Head The name plate shall be of stainless steel and relevant information shall be punched into the same.
Supply, install, testing and commissioning of 10 HP/7.5KW 8 stage open well submersible motor pump 2900 rpm, 415 V 3 Phase, minimum 70 Mtr head and discharge Maximum 800 LPM ,with maximum operating pressure 20 bar of shaft material stainless steel with bronze impeller complete with locking arrangement inside pit, including fittings like stainless steel strainer, foot valve, flanges, coupling as per existing complete all as specified and directed by Engr-in-charge.
Supply and fixing High pressure vehicle washer flow 40 LPM pressure RPM 1428, motor 2 HP, including Spray gun with adjustable Nozzle, 20 M water outlet pressure hose, 20 Meter electric cable, portable system/ Frame mounted, with Foam Gun and including PCC 1:2:4 type B1 (20mm graded crushed stone aggregate) foundation as per manufacture instruction and designed approved by Garrison Engineer complete. Note:- (i) Before making of PCC foundation & drawing contractor shall submit details general arrangement drawing and single line drawing of platform for Motor and pump as per manufacturer's instruction for Approval of GE (ii) Provision of PCC foundation, foundation bolt as per manufacturer design, excavation and RFR for foundation, making good the disturbed surfaces matching with existing surfaces. (iii) Motor Pump shall be mounted on common foot company make base frame coupled to each other with suitable coupling. (iv) Alignment of motor pumping set with existing network, connection of starter and cables shall be part of job, nothing shall be entertained on this account.
Supply and fixing PVC insulated ,PVC round Sheathed FR , Flexible 3 core copper conductor cable of size 70 Sqmm as per ISI 1554/IS -694 including, thimble etc with and including cutting and chasing in PCC flooring and walls etc complete all as specified and directed.
Supply and fixing PVC insulated ,PVC round Sheathed FR, Flexible 3 core copper conductor cable of size 35 Sqmm as per ISI 1554/IS -694 including, thimbles etc with and including cutting and chasing in PCC flooring and walls complete all as directed.
Supply and fixing PVC insulated ,PVC round Sheathed FR, Flexible 3 core copper conductor cable of size 25 Sqmm as per ISI 1554/IS -694 including, thimble etc with and including cutting and chasing in PCC flooring and walls complete all as specified and directed.
Supply and fixing PVC insulated, PVC Sheathed FR , Flexible , flat 3 core copper conductor cable of size 16 Sqmm as per ISI 1554/IS -694 including thimble etc with and including cutting and chassing in PCC flooring and walls complete all as specified and directed.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 600cm x 600cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to Galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed. Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
Dismantling existing unserviceable / deteriorated motor starter and capacitor panel, removal from site and depositing to MES store yard and supply, installation, testing and commissioning of indoor type floor mounting size not less than 800 x 900 x 500 mm Polycarbonate CPRI approved OEM made Motor Starter Panel suitable for , shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily.
Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warrantee certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960 degree C in accordance with IEC 60695-2-11 [flame retardant and self-extinguishing] with MC 75 for base frame & angle iron 50 x 50 x 6 mm size legs , 04 nos legs 600 mm long, PCC 1:2:4 type B-1 (20mm graded curshed stone aggregate) for grouting of base,suitable for 3 phase 415 volts 50 Hz 4 wire AC supply complete all as directed with and incl the following:-
FIRST CABIN : (i) MCB 3 pole, 415 Volts, rating 32 Amps, 10 KA - 04 No. (ii) Line contactor, AC 3 duty, 415 Volts, 50 Hz, 185 Amps-01 No. (iii) Digital soft starter suitable for 90 kW motor, 3 phase, 415 Volts, 50 Hz including one spare power control board of digital starter - 01 No. (iv) Independant Control supply transformer and fast acting semiconductor fuse of suitable rating for soft starter protection -01 No. Each (v) Resin cast CT 300/5A cast resin base – 01 set of 03. (vi) Push button ON/OFF, AC 415 Volts 50 Hz - 02 Nos. (vii) LED indication lamp AC, 415 Volts , 50Hz for RYB, ON/OFF, trip - 06 Nos. (viii) Emergency push button OFF - 01 No. (ix) Terminal block suitable for 300A rating with brass contacts for INPUT/OUTPUT termination with 9 ways. (x) 3 Phase 4 wire copper bus bars of suitable length & section not less than 30 x 10mm covered with coloured heat shrinkable anti track insulation tape of make Denson/ M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 set. (xi) Control wiring of push buttons, indicators/ protection circuits contactors, soft starter with 1.5 Sqmm multi strand copper cable, lugs and ferrules- 01 Job as per circuit design complete all as specified and directed.
Dismantling existing unserviceable / deteriorated motor starters and capacitor panel, removal from site and depositing to MES store yard and supply, installation, testing and commissioning of indoor type floor mounting size not less than 800 x 900 x 500 mm Polycarbonate CPRI approved OEM made Motor Starter Panel suitable for , shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of board/panel shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE OF DEGREE OF INGRESS PROTECTION IP65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily.
Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Guarantee and warrantee certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960 degree C in accordance with IEC 60695-2-11 [flame retardant and self-extinguishing. MC 75 for base frame & angle iron 50 x 50 x 6 mm size legs , 04 nos legs 600 mm long, PCC 1:2:4 type B-1 for grouting of base,suitable for 3 phase 415 volts 50 Hz 4 wire AC supply complete all as directed with and incl the following:- FIRST CABIN : (i) MCB 3 pole, 415 Volts, rating 32 Amps,10 KA - 04 No.
(ii) Line contactor, AC 3 duty, 415 Volts, 50 Hz, 60 Amps-01 No. (iii) Digital soft starter suitable for 25 kW motor, 3 phase, 415 Volts, 50 Hz including one spare power control board of digital starter - 01 No. (iv) Independant Control supply transformer and fast acting semiconductor fuse of suitable rating for soft starter protection -01 No. Each (v) Resin cast CT 100/5A cast resin base- 01 set of 03. (vi) Push button ON/OFF, AC 415 Volts 50 Hz-02 Nos. (vii) LED indication lamp AC, 415 Volts , 50Hz for RYB, ON/OFF, trip - 06 Nos. (viii) Emergency push button OFF - 01 No. (ix) Terminal block suitable for 100A rating with brass contacts for INPUT/OUTPUT termination with 9 ways. (x) 3 Phase 4 wire copper bus bars of suitable length & section not less than 10 x 10mm covered with coloured heat shrinkable anti track insulation tape of make Denson/ M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 set. (xi) Control wiring of push buttons, indicators/ protection circuits contactors, soft starter with 1.5 Sqmm multi strand copper cable, lugs and ferrules- 01 Job as per circuit design complete all as specified and directed.
BANSAL ENGINEERING
M/s Friends Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .