Superintending Engineer, PWD Dibrugarh Building Ci
Superintending Engineer, PWD Dibrugarh Building Circle, Dibrugarh
Construction of National Emergency Life Support (NELS) Training Centre at Assam Medical College and Hospital Dibrugarh
2023_PWBNH_29988_1
SE(B)/DIB/CS-17/22-23/318-A
Open Tender
Civil Works - Building
Item Rate
365 days
Assam Medical College and Hospital Dibrugarh
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,156
₹2.2 L
Yes
Superintending Engineer, PWD Dibrugarh Building Ci
25 Apr 2023
21 Mar 2023
29 Mar 2023
21 Mar 2023
29 Mar 2023
21 Mar 2023
22 Mar 2023
Amount
DISMENTLING & DEMOLISHING 15.7 : - Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.15.7.4 : In cement mortar
15.13 : - Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :15.13.1 Of area 3 sq. metres and below
15.44 : - Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15.44.1 : - 15 mm to 40 mm nominal bore
15.57 : - Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
15.58 : - Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
15.23 : - Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 15.23.1 : - For thickness of tiles 10 mm to 25 mm.
2.6 : - Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge 2.6.1 : - All kinds of soil For Stair Case (Coloumns & Footings )
For Lift
11.2 : - Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. Brick on flat soling under foundation etc. For Stair Case Under Footings
16.12 : - Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1 : -With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 For Lift
4.1.5 : - Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 : - 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size
4.1 : - Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.2 : - 1:1½:3. For Lift
5.1 : - Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 - 1:1.5:3 For Lift
5.2 : - Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 : - 1:1.5:3 For Lift
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3. For Lift
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. For Stair Case (Back Filling )
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 : - 1:1½:3 . For Stair Case (Footings & Coloumns up to PL )
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 : - 1:1.5:3. Coloumns Above PL
FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 : - Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. For Stair Case (Footings)
For LIFT
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. . For Lift
5.9.3 Suspended floors, roofs, landings, balconies and access platform. For Lift
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 : - Columns, Pillars, Piers, Abutments, Posts and Struts. For Stair Case (Coloumns )
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 : - (Thermo-Mechanically Treated bars of grade Fe-500D or more. For Stair Case (Footings, Footing Base and Column )
For Lift
5.22A : - Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 : - TMT of grade Fe-500D or more In Substructure & Superstructure upto Floor Level-1: iii. Above Plinth Lvl. For Lift
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete For Stair Case (For Post, Beam, Landing etc including 5% Wastage)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.1 : - In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. For Stair Case (Frame Work for For Stringer, Landing, Trade Riser etc )
10.25.2 : - In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. For Stair Case (Square Bar Size - ISSQ - 10 Side Width - 10 mm ( For Railing, Newel Post, Baluster etc) including 5% Wastage )
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.2 : - Hot finished seamless type tubes. For Stair Case A. Roof Truss
Providing corrugarted G.S. Sheet roofing including vertical / cured surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen ...complete. 12.1.1 : - 0.80mm thk with zinc coating not less than 275 gm / m² For Stair Case
12.4 : - Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 12.4.1 0.80 mm thick with zinc coating not less than 275 gm/m² For Stair Case
HALF BRICK MASONRY 6.12 : - Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : 6.12.1 Cement mortar 1:3. I. Partition Wall
ii. For LIFT
CEMENT PLASTER (IN FINE SAND) 13.1 : - 12 mm cement plaster of mix : 13.1.1 : - 1:4 (1 cement: 4 fine sand) i. For LIFT
15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 : - 1:4 (1 cement: 4 fine sand) a. On Rough & Fare Side. I. Partition Wall
WATER PROOFING : - 22.3 : - Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand)mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface .iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
EXPANSION JOINT FILLER BOARD 16.45 : - Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound mpregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (e ) 75mm wide, 450mm Depth, length = 11.30 m
FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 : - Size of Tile 600x600 mm i. For Floor & Skirting
GRANITE FLOORING 8.2 : - Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 ... complete at all levels. 8.2.2 : - Granite stone slab colour black, Cherry/Ruby red 8.2.2.2. : - Area of slab over 0.50 sqm. - For Kitchen Slab and Reception Counter
ANTISKID TILES 11.414A : - Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4. 11.41A.3 : - Glazed Vitrified tiles Matt/Antiskid finish of size 11.41A.3.1 : - Size of Tile 600 x 600 mm A. For Bath Room and Toilet .
Wall Tiles 8.31 : - Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3. A. For Dining Room, Store And Toilet
STEEL DOOR FRAME 10.14 : - Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm....complete as directed by Engineer-in-charge: 10.14.3 : - Profile -E 10.14.3.1 : - Fixing with adjustable lugs with split end tail to each jamb
DOORS 9.21 : - Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 9.21.1 - 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
False Ceiling 12.45 : - Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (Both side inclusive). 12.45.3 : - 12.5 mm thick tapered edge gypsum moisture resistant board.
GRILL 10.2 : - Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. I . Plain grill. (c) Fixed to Brickwork/P.C.C/R.C.C.
ALUMINIUM DOORS, WINDOWS AND OTHER WORKS 21.1 : - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions. 21.1.1 : - For Fixed portion 21.1.1.2 : - Powder coated aluminium (minimum thickness of powder coating 50 micron) For Window and Ventilation.
21.1.2 : - For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.2 : - Powder coated aluminium (minimum thickness of powder coating 50 micron).
21.3 : - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.1 : - With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm
PAINTING 13.8 : - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
SANITARY AND WATER SUPPLY 17.81 : - Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. a. Western Type W.C
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.4.1. One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : 17.6.1 : - Single squatting plate with 5 litre P.V.C. automatic flushing cistern
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : 17.5.1 : - Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
17.7 : - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.6White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap
17.7A : - Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- a. White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
17.28Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.28.2 : - Flexible pipe 17.28.2.2 : - 40 mm dia
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
17.71. : -- Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
17.32 : - Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.4 : - -Rectangular shape 1500x450 mm
17.33 : - Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
17.34 : - Providing and fixing toilet paper holder : 17.34.1 : - C.P. brass
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
18.64 : - Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
18.51.Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 18.51.1. : - 15 mm nominal bore
18.52 : - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 : - 15 mm nominal bore.
18.53 : -- .Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 18.53.1 : - 15mm nominal bore
18.9 : - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work 18.9.9 : - 100 mm nominal I.D. Pipe
18.9.8 : - 75 mm nominal I.D. Pipe
18.58.Providing and fixing PTMT grating of approved quality and colour. 18.58.1 : - Circular type. 18.58.1.1 : - 100 mm nominal dia
17.10Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.1 : - Kitchen sink with drain board. 17.10.1.2 : - 510x1040 mm bowl depth 225 mm
18.50 : - Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 18.50.1 : - 15 mm nominal bore For Kitchen Sink
18.10 : - Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal Work, exposed on wall 18.10.5 : - 40 mm dia nominal bore
18.8 : - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia pipes
25 mm nominal outer dia pipes
15 mm nominal outer dia pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). 18.17.1 : - 25 mm nominal bore
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2000 Lt capacity
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
Group B
Group C
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Double pole
Triple pole and neutral
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp, 30KA, FPMCCB
200 Amp, 36KA, FPMCCB
250 Amp, 50KA, FPMCCB
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable Supply, earthing etc. complete as required.for 230 V, 50 Hz, single phase AC
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Providing and fixing of metalic MCCB Enlosures four pole in wall etc. including drilling holes making connections, etc. as required.
Supplying & laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 3½ X 50 sq. mm 1.1 KV grade aluminium conductor armoured UG cable
Supplying fitting & fixing of surface and wall mounted LED tube batten Model CCS-103-20SL-DP-NWH CROMPTON make or equivalent for 20W.
Supplying fitting & fixing of 9 W LED bulb JUVAS MAKE in the existing lamp holder as specified and directed by the department .
Supplying with installation testing and commissioning of Hi -- wall 3 STAR rating non ducted inverter split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department. 2.0 T on capacity. (Rate as per LG Company price list 2021-22 inclusive GST)
Supplying installation testing and commissioning of 8 Passenger Elevator with 3 stop 3 opening single entrance car with machine room as per specification
O.P.GARODIA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .