GEMC-511687731487928
Awarded to NIYURA TECHNOLOGIES PRIVATE LIMITED
₹59,220
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BPE NIy 1 kva 168 vah Line interactive UPS | BPE NIy 1 kva 168 vah Line interactive UPS | - | 18 NOS | ₹3,290 | 59,220 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹59,220Qualified Make: BPE
Model: BPE NIy 1 kva 168 vah Line interactive UPS AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE NIy 1 kva 168 vah Line interactive UPS | L1 | Qualified | |
| 2 | L3₹88,200+₹28,980 (48.9%)Qualified Make: microtek
Model: Microtek Twin Guard Pro+ 1000VA/168VAH up to 15 Minutes back up+ 2 years warranty B 921 GREEN FIELDS COLONY FARIDABAD 2821 121003 INDIA | FARIDABAD | HARYANA | 121003 | Make: microtek
Model: Microtek Twin Guard Pro+ 1000VA/168VAH up to 15 Minutes back up+ 2 years warranty | L3 | Qualified | |
| 3 | L5₹1.2 L+₹58,374 (98.6%)Qualified Make: APC
Model: APC BACK FRTE UPS 1.1KVA BX-1100C-IN AGROHA MARG KORBA KORBA 2815 495677 INDIA | KORBA | CHHATTISGARH | 495677 | Make: APC
Model: APC BACK FRTE UPS 1.1KVA BX-1100C-IN | L5 | Qualified | |
| 4 | Qualified Make: Intex
Model: INTEX 1 KVA OFFLINE UPS H NO 382 BEHIND POST OFFICE RAIPUR AGROHA MARG RAIPUR CHHATTISGARH 493211 | 493211 | Make: Intex
Model: INTEX 1 KVA OFFLINE UPS | - | Qualified | |
| 5 | Qualified Make: VERTIVE
Model: Liebert itON CX-1000 GROUND FLOOR C 10 VIGYANPURI MAHANAGAR EXTENSION LUCKNOW UTTAR PRADESH 226006 UDYAM UP 50 0008785 09AADCN3125F1ZQ B R M B MII STATUS AS VERIFIED | LUCKNOW | UTTAR PRADESH | 226006 | Make: VERTIVE
Model: Liebert itON CX-1000 | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
1 Aug 2018, 4:00 pmClosed
Line Intractive UPS with AVR Experience with Gov. Required 2 Year (s) Line Intractive UPS With AVR ( 18 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line Interactive UPS 2 Years 1 Year
2 Years
5 Years
3 Years Installation and commissioning instructions No - CONSTRUCTIONAL Type of enclosure ABS - AC out put for Yes Yes
No 1/4 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/4 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Indu Bhushan Karna 495452
SECL DIPKA AREA 18 15
397079
GEM/2018/B/56201
GeM Contract
Line Intractive UPS with AVR
GeM Contract
15 days
Chhattisgarh; Korba
PRODUCT
Awarded to NIYURA TECHNOLOGIES PRIVATE LIMITED
₹59,220
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BPE NIy 1 kva 168 vah Line interactive UPS | BPE NIy 1 kva 168 vah Line interactive UPS | - | 18 NOS | ₹3,290 | 59,220 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Experience with Gov. Required 2 Year (s) Line Intractive UPS With AVR ( 18 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line Interactive UPS 2 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years | - | - | - |
| 3 Years Installation and commissioning instructions No - CONSTRUCTIONAL Type of enclosure ABS - AC out put for Yes Yes | - | - | - |
| No 1/4 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/4 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Indu Bhushan Karna 495452 | - | - | - |
| SECL DIPKA AREA 18 15 | - | - | - |
Exempted
18 Aug 2018
28 Jul 2018
contract_GEMC-511687731487928.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_397079.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .