Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.8 CrAccepted-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹3.8 Cr | 1 | Accepted-AOC Being lowest |
| 2 | 2₹4.1 Cr+₹22.1 L (5.78%)Rejected-AOC 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹4.1 Cr+₹22.1 L (5.78%) | 2 | Rejected-AOC Being not lowest |
| 3 | 3₹4.2 Cr+₹36.0 L (9.39%)Rejected-AOC | ₹4.2 Cr+₹36.0 L (9.39%) | 3 | Rejected-AOC Being not lowest |
| 4 | 4₹4.4 Cr+₹57.1 L (14.9%)Rejected-AOC 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹4.4 Cr+₹57.1 L (14.9%) | 4 | Rejected-AOC Being not lowest |
| 5 | 5₹4.4 Cr+₹61.0 L (15.9%)Rejected-AOC | ₹4.4 Cr+₹61.0 L (15.9%) | 5 | Rejected-AOC Being not lowest |
Tender Value
Refer Docs
EMD Value
₹5.7 L
Closing Date
11 Aug 2021, 6:00 pmClosed
Chief Engineer 31 Zone
HQ Chief Engineer 31 Zone PIN-914631 C/O 56 APO
AUGMENTATION AND IMPROVEMENT OF EXISTING ELECTRIC SUPPLY INFRASTRUCTURE AT BB CANTT SRINAGAR (PHASE-I)
2021_MES_458004_1
800118/2020/E8
Open Tender
Electrical and Maintenance Works
Item Rate
924 days
Srinagar
As per NIT
11 documents required · 11 mandatory
₹2,000
Garrison Engineer 864 EWS
₹5.7 L
Yes
16 Sept 2021
8 Jul 2021
13 Aug 2021
8 Jul 2021
11 Aug 2021
29 Jul 2021
8 Jul 2021 - 7 Aug 2021
Amount
Dismantling existing cross arms of any capacity/size of MS channel or angle sections etc complete all as specified and as directed by Engr-in-Charge.
Dismantling existing insulators of any type and any size from pole including pins all as specified and as directed by Engr-in-Charge.
Dismantling stay assembly of any type embedded in cement concrete etc all as specified and directed by Engr-in-Charge. Note: Demolition of cement concrete etc. and necessary excavation and earthwork will be measured and paid for separately under relevent items of BOQ.
Dismantling and taking down the existing LT/HT over head ACSR or AAC conductor of any description all as directed.
Dismantling of house service brackets any type including making good disturbed work all as specified and directed by Engr-in-Charge.
Dismantling air break gang operated switches vertical/ horizontal mounted including insulators and operating mechanism etc all as directed by Engr-in-Charge.
Demolition of cement concrete of any description for old stay assembly retrieved from item No 3 all as directed.
Supply, laying, jointing, commissioning and testing of 11000 volts (earthed) grade Aerial Bunched Cable with 3 (three) power Cores Stranded, compacted Circular Aluminium Conductor 95 Sqmm screened with Black extruded semi-conducting Compound, natural coloured XLPE insulated core screened with Black extruded semi-conducting compound and one layer of copper tape and covered with Black extruded PVC (Core identification by ridges one, two and three over PVC covering) and one bare Messenger wire 95 Sqmm ( combination of galvanized steel wire and Aluminium Alloy wires ) confirming to IS 3130/1984, IS-398 (Part-II)/1996, IS-398 (Part-VI) /and IS-7098 (Part -II)/2011 with upto date amendments, complete all as specified and directed. Note:- Quoted Rates shall be deemed to include cost of necessary MS clamps required for fixing of cable on HT pole.
Supply, jointing, commissioning and testing cable end jointing kit, outdoor type, suitable for 11KV grade ABC XLPE cable of size 95 sqmm 3 core and 1 bare messenger 95 Sqmm including jointing material complete all as specified and directed.
Supply, laying, jointing and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor, 33000 Volts grade (E), of size 3 core 300 sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 33 KV (E) grade cable for outdoor end termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 300 to 400 Sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 33 KV (E) grade cable for Straight through Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 300 to 400 Sqmm complete all as specified and directed.
Supply, laying , jointing and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor, 11000 Volts grade (E), of size 3 core 95 sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV (E) grade cable for outdoor end termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV (E) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV(E) grade cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.
Supply, laying , jointing and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor, 11000 Volts grade (E), of size 3 core 185 sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV (E) grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV (E) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV (E) grade cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed.
Supply, laying , jointing and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor, 11000 Volts grade (E), of size 3 core 240 sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV (E) grade cable for outdoor end termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 240 to 300 Sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV(E) grade cable for indoor end termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 240 to 300 Sqmm complete all as specified and directed.
Supplying, installation, testing and commissioning of 11 KV, 630 Amps outdoor type ring main unit extendable type, duly prewired, suitable for working on rated voltage 12 KV, system voltage 11 KV, 21 KA, 50 Hz, three phase, three wire, having short circuit capacity 21 KA/3 sec. Outdoor type (compact switch gear) comprising 2 number load break switch incomer and one number Bus coupler with fixed type LBS breaker in SF6 insulated stainless steel/ Alu-zinc enclosure with electrolitic grade copper bus bar, robotically welded stainless steel ( Non ferrite non magnitic grade) tank with minimum thickness 3.15 mm ± 0.5mm, IP 67 degree of protection, Auxillary power supply backup, internal arc classified 21 KA/3 sec with site replaceable bushing/coupling/mechanism etc.. The RMU shall be suitable for operations at a height of 1550 mtrs above or below sea level (suitable for Srinagar), in temperature range of avarage ambient temp + 45ºC to (-) 25ºC, in electrically exposed locations, exposed to high relative humidity. The active part of the RMU switch gear shall be maintenance free and the switchboard shall be low maintenance. The unit alongwith bus connected, fixed type potential transformer/ Currrent transformer for respective section including the following accessories and fiitings as required at site:-
(a) The circuit breaker and earthing switches shall be lockable in the open or closed position by suitable number of padlocks of suitable size. (b) Motorised spring mechanism with 110 V DC/AC universal motor 200 Watt charging time less than 5 Sec. (c) Inter Panel barrier to prevent arc propagation from one panel/ compartment to other. (d) Earthing switch rated to full making capacity with provision for safe & reliable position indicator. (e) Load Break switch (LBS) unit shall also comprise of the following :- (i) Assembly of load break switch complete with epoxy supports, insulators and self alligning isolating contacts with rating 11KV, 630A, 21KA (3 Sec), 50 Hz, 3 Phase. (ii) Electrically charged and electrically operated independent closing/ tripping, trip free, operating mechanism including manual closing/ tripping push button and breaker closed/ open, spring charge/ discharge indication. (iii) Mechanical operation counter - 01No. (iv) Electrical closing coil operated on 110 V, DC/AC supply - 01No. (v) Shunt tripping coil operated on 110 V, DC/AC supply - 01No. (vi) Suitable interlocking between both incomings/ different feeders as per standard manufacturing, all as per relevant IEC/ IS code. (f) One bus bar chamber including a set of 3 Phase, 630 Amps, copper bus bar. (g) Strip heater 230V, AC single phase, 80W. (h) Current transformer chamber comprising of 3 Nos. single phase resin cast/ ring core CT's of 200-100/1+1, burden not less than 15 VA and accuracy class 1.0 for metering and class 5P10 for protection as per IS- 2705 for each circuit breaker- 02 sets. (j) One No. potential transformer (PT) three phase dry type (resin cast) draw out type 11 KV/ 110V, 100VA burden, accuracy class 0.5 with HT & LT HRC fuses for primary and secondary complete as per IS- 3156 - 01Setc.
(k) SCADA compatible solid state numerical O/C & E/F relay for complete protection of HT, 11KV, three phase feeder having facility to record fault current with date and time with suitable communicable port as approved by GE/EIC - 02 Nos. (l) Arc flash supervision of circuit breaker, cable and bus bar compartment. (m) Digital SCADA compatible intelligent panel meter indicating line/ phase current, line/ phase voltage, power factor, KVAR, KVA, frequency, wave forms, THD etc. with accuracy class 0.5 for all incoming feeder of RMU - 02 Nos. (n) One set of indication lamp LED type for ON/ Off indication in all LBS/VCB/SF6 breaker. (o) Two sets of indication lamp (LED) type for spring charging and three Nos. indication lamp RYB phase indication in all LBS/ VCB/ SF6 breaker. Make of RMU : AREVA/ ABB/ SCHNEIDER/ SIEMENS Additional Equipment delivered separately or mounted seperately :- (i) Operation Handle for manual isolated / Disconnector/Earthing Operation - 04 Nos (ii) Standard Manometer - 01 No (iii) Operation and maintenance Manual - 01 No (iv) Installation & Commisioning Manual - 01 No (v) Cable clamping provision (standard) - 01 No (vi) Provision of Battery charger with suitable batteries. (vii) Necessary electrical / mechanical interlocking arrangement shall be provided for saftey and operation. (viii) Above switch gears shall confirm to relevant IEC (62271-200) for design and manufacturing and internal Arc compliance.
(ix) Any claims towards internal arc, Nos of mechanical/ electrical/ short circuit operation, gas leakage rates etc. shall not be accepted unless provision via type test reports of model being offered. To ensure integrity of protection scheme the vacuum bottle, breaker and relay should be of same make. (x) Cost of taking down of existing cable from four/ two pole structure and fixing in RMU making all arrangements shall deemed to be included in the rate quoted by bidders/ contractors. Notes: (i) The contractor shall arrange for factory visit of rep detailed by accepting officer to carry out routine & type test (Non-destructive) as per relevant IS/ IEC codes before despatch of material. (ii) The Vacuum Circuit Breaker (VCB)/ SF6 circuit breaker and load break switches shall conform to all relevant IEC standards and IS standards. (iii) The cost of Anything missed out item above which is technically required for efficient operation of RMU shall be deemed to be included in the quoted rates. (iv) The material will be purchased only through original manufacturing company. (v) The RMU shall be installed on suitable PCC platform of adequate height/ size as per recommendation of manufacturer. The quoted rate is deemed to include for this provision.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 400 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 300 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded, 1100 Volts grade, of cross sectional area 240 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing undergroung LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded, 1100 Volts grade, of cross sectional area 185 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing undergroung LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 150 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 120 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded, 1100 Volts grade, of cross sectional area 95 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded, 1100 Volts grade, of cross sectional area 70 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing undergroung LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded, 1100 Volts grade, of cross sectional area 50 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing undergroung LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 35 sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing undergroung LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 25 sqmm 4 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed.
Supply, laying , jointing and testing undergroung LT cable XLPE insulated heavy duty, GI steel or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 16 sqmm 4 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. complete all as specified and directed
Supply, laying , jointing and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured PVC insulated electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size 4 core 10 sqmm complete all as specified and directed.
Supply, laying , jointing and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured PVC insulated, electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size 2 core 25 sqmm complete all as specified and directed.
Supply, laying , jointing and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured PVC insulated,electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size 2 core 16 sqmm complete all as specified and directed.
Supply, laying , jointing and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured PVC insulated electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size 2 core 10 sqmm complete all as specified and directed.
Supply, laying , jointing and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured PVC insulated electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size 2 core 06 sqmm complete all as specified and directed.
Supply and fixing LT switch gear 440 Volts, 3 phase, 4 wire, 50 cycles, Air circuit breaker, cubical manual drawout type complete with microprocessor release of capacity rating up to 800 Amp, 50KA. The protection relays should be provided with in built short circuit protection, overload protection, instantanious protection (IPR), ground fault protection and functional blocking, The ACB should have been designed for an operating voltage upto 690 volts. The rated insulated voltage (UI) should be 1000 volts and the rated impulsive voltage (UMP) should be 12KV including sheet enclosure and mounted arrangement etc complete all as specified and directed. Makes : Havells, Legrand, Schneider
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level, connecting to galvanized iron strip of size 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of brass after welding of GI strip to earth electrode to the full length of earth plate, GI light grade pipe 40 protection pipe upto test point, 20 mm dia GI medium grade watering pipe with funnel and wire mesh, PCC pit using cement concrete1:2:4, type B-1 with pit cover of size 30 x 30 cm made of RCC 1:3:6, C-1 (using 20 mm graded crushed stone aggregate) with suitable handle, angle iron frame made of angle iron of size 40 x 40 x 4 mm, adequate quantity of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling all as specified in electrical plate No 3 of SSR part-I and as directed by GE including testing on completion. Note : Galvanised MS strip shall be measured up to 7.5 mtr.
Material and labour for galvanised iron strip 32 x 6 mm buried directly in ground all as specified and directed.
Material and labour test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including three number, 8mm dia 25mm long hex. head screw complete all as specified and directed.
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-55, 11.00 metre long , complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified including painting with two coats of aluminium paint heat resistant type over one coat of red oxide primer and making 06 Nos bands/ straps with white and black colour ( 30 cm wide each) synthetic enamel paint at a distance 30 cm from plinth block and numbering of poles with black bitumenous synthetic enamel paint in 2.5 cm height including tarring one coat on steel surface embedded in concrete foundation complete all as specified and directed.
Supply and fixing street light panel 6 KW confirm to IS/ IES 60947-4-1 suitable for three phase MCB rating 40 amps on /off timer Astronomical, contactor rating 32 amp including internal wiring in built short circuit protection, IP-54 and by pass arrangement complete all as specified and directed.
Supply and fixing street light panel 6 KW confirm to IS/ IES 60947-4-1 suitable for three phase MCB rating 63 amps on /off timer Astronomical, contactor rating 63 amp including internal wiring in built short circuit protection, IP-54 and by pass arrangement complete all as specified and directed.
Supply and fixing Three phase On load change over switch with enclosure 320 Amps 4 Pole with door interlock kit complete all as specified and directed. Makes : Havells Cat part No IHCNF 00320 or equivalent in CG, L&T & HPL
Supply and fixing Three phase On load change over switch with enclosure 400 Amps 4 Pole with door interlock kit complete all as specified and directed. Makes : Havells Cat part No IHCNF 00400 or equivalent in CG, L&T & HPL
Supply and fixing Three phase On load change over switch 630 Amps 4 Pole with door interlock kit complete all as specified and directed. Makes : Havells Cat part No IHCNF 00630 or equivalent in CG, L&T & HPL
Supply and fixing LED 72 watt pressure dia cast alumunium alloy for housing ( heat sink) for effective thermal management sturdiness, excellent corriosion resistance long life and photobioligically safe LED's, No harmful UV & IR rediatins , instant light with low running temperature, operating temperature (-10ºc) to (+50ºc) with system lumen >/110 Lm/W high efficiency long life LED made with SMD LED package mounted MCPCB . Powered with integral Electric LED driver (SMPS based) over voltage protection , surge voltage protection 10KV with SPD & other safety as per IS 15885 Part-II Sec 13 complete all as specified and directed. Makes : Philips, Havells, GE, Crompton
M&L boring of holes under roads pavements, hards standing by trenchless technology using ultra sound technique & necessary machine including HDPE pipe of 6 kg/sqmm of 150 mm dia suitable 0.4 Mpa working pressure, length of pipe min - 5mtr complete all as specified and directed.
Supply and fixing air break gang operated Triple pole, vertical type, rocking tilting type, 11000 Volts mounted on insulator and steel frame, with operating mechanism worked from ground level, including drop out fuze insulators set (12 insulators) for current rating upto 400 amps complete all as specified and as directed.
Supply and fixing pin insulator 150 mm height, 150 mm dia for 11000 volts grade including 01 galvanized M.S.spindle, two galvanised iron washers and one galvanised iron nut straps etc complete all as specified and directed.
Supply and fixing Disc type, insulator two in series, porcelain, vitreous, 145mm height and 255mm dia ball and socket type, white brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts with GI nut, bdfs straps etc complete all as specified and as directed.
Material and labour for cross arms of any sizes with drilled hole (hot and cold etc) in position M.S. work including MS nut and bolts, washers in any shape or size and two coats of aluminium paint over one coat of red oxide primer, all as specified and directed.
Material and labour for anti climbing devices spikes type fabricated out of MS bar (round/square/flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole and one finishing coat of alumunum paint, complete all as specified and directed.
Supplying and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and and fixed with M.S. clamps, bolts and nuts of approved size for HT 25 x 20 CM size all as specified.
Supply and fixing stay assembly for LT/HT steel tubular poles comprising of 7/4 dia galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including GI clamps bolts, nuts, washers, galvanized steel stay rod 20 mm dia 180 cm long bow 400 x 14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 65 x 90mm vitreous, clearance dia of hole 20 mm, stay plate of size 300 x 300 x 6 mm, GI stay wire, stay clamp turn buckle (19 x 600mm) complete all as specified and directed. Note : Galvanised MS Stranded stay 7/4 shall be measured and paid seperately under relevant items.
Material and labour for galvanised stranded 7/4mm dia suaitable stay assembly complete all as specified and directed.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nut and bolts for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed of 150mm bore.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nut and bolts for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed of 100mm bore.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nut and bolts for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed of 80mm bore.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nut and bolts for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed of 50mm bore.
Material and labour for GI tubing light grade including all fittings such as elbow, bends, clamps including nut and bolts for cable protection along poles, wall surface, under ground or road crossing etc complete all as specified and directed of 40mm bore.
Supply and fixing of lightening arrestors non linear resistance type suitable for HT 11 KV, Discharge capcity 12KV out door type complete with all fittings, transmission class discharge 30 Kilo Amps mounted on pole including connecting with earth strip complete all as specified and directed.
Supply and fixing lightening arrestors explusion type with all fittings, transmission class, discharge capacity 65 kilo amps suitable for 33000 volts complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying of cables, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth but not exc 3 m in depth ; for foundation, etc. or for laying of cables, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil complete all as specified and directed. Notes for Item No 74 & 75 : - Entire excavation for shall be carried out manually only and not through excavator/JCB to avoid damage of existing electric supply/water supply/signal assets. This aspect may be noted while quoting the bid.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches for cable protection complete all as specified. Note:- Measurement shall be taken only after punning down sand cushioning.
Material and labour for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata & relaxing taken out cable complete all as specified and directed.
Material and labour for Cement concrete (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata & relaxing taken out cable complete all as specified and directed.
Material and labour PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) in coping/plinth blocks for poles and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary Steel form work and finishing the surfaces fair in forms complete all as specified and directed..
Supply and fixing air break isolating switches 33000 Volts mounted on insulator and steel frame, with operating mechanism current rating upto 400 amps capacity complete all as specified and as directed.
Supplying and fixing HT/LT MS cable route indicator, engraved the description on the disc not less than 6" dia welded with 40 x 6 mm MS Strip of approximate length 90 cm duly painted on all steel parts as per colour code and provision of PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) of not less than 0.05 cum in each at base buried under the ground including necessary earth work complete all as specified and directed.
Supply and laying reinforced precast PCC cable Cover ISI marked, class EHV, type- 3 with peak, size 450mm x 230mm x 50mm for covering cables laid dry flat as cable protection on sand all as specified.
Supply and laying un-reinforced precast PCC cable Cover ISI marked, class HV, type-3, flat, size 450mm x 180mm x 40mm for covering cables laid dry flat as cable protection on sand all as specified.
Supply and laying un-reinforced precast PCC cable Cover ISI marked, class LV, type-1, flat, size 250mm x 150mm x 40mm for covering cables laid dry flat as cable protection on sand all as specified.
Material and labour for road cutting of minimum sizes 30cm x 30cm and minimum width of 3 mtrs for laying cables etc and making good the disturbed surface to match existing surface using PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate), complete all as specified and as derected. Note :- The cost of material required for making good shall be deemed to be included in the rate quoted.
Suppling and laying synthetic rubber insulating mats 3mm thick for voltage up to 33KV of size 2 mtr x 1mtr x 19mm for electric purpose as per relevants IS (superseding IS 5424) suitable for electric shock safety complete all as specified and directed.
Supply and fixing Street light bracket 1.5 Mtr long made out of 40mm dia GI pipe light grade bend to shape welding etc and fixing on existing LT pole with 40 x 6mm flat iron MS clamps including necessary nuts, bolts and washers etc and including painting two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for junction box pole mounted of size 230 x 170 x 110mm made out of engineering plastic comprising 60 Amps, 4 pole aluminium bus bar mounted on DMC insulator, 1 No SP MCB 6 Amps, 10 KA, junction box should be mounted on pole with MS flat iron of sizes 40mm x 6mm including nuts, bolts and washers complete all as specified and directed. Note: Quoted rates shall be deemed to be inclusive of 1.5 sqmm 3 core flexible copper cable from junction box to street light as per site requirement.
Sant Construction Co.
ALCO ENGINEERSPVT LTD
SAGGI ELECTRIC COMPANY
G N Constructions
RAMESH AND CO
CHINAR CONSTRUCTION TRADERS
M/S ABDUL SALAM MIR CONSTR CO PVT. LTD
Intrernational Engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .