| 1 | L1₹27.0 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹30.8 L+₹95,847.05 (3.21%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹31.0 L+₹1.1 L (3.57%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹38.1 L+₹8.2 L (27.4%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹83,000
Closing Date
4 Jan 2021, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/REPLACEMENT OF DBs SUB MAIN WIRING BUILDING SECURITY LIGHTS EARTHING AND CONNECTED WORKS IN OTM AND MD ACCN AT SHANKAR VIHAR ANUJ VIHAR VIKRAM VIHAR TARAPORE ENCLAVE 35 INF BDE 13 KUMAON AND 5/11 RG INCLUDING REPAIR/ REPLACEMENT OF OLD/UNSERVI
2020_MES_401380_1
GE/DS-58/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹83,000
Yes
4 Feb 2021
7 Dec 2020
6 Jan 2021
7 Dec 2020
4 Jan 2021
21 Dec 2020
8 Dec 2020 - 19 Dec 2020
Amount
S&F in replacement of VTPN distribution board 8 way double door, vertical type for fixing MCCB up to 250 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections and connecting complete all as specified and directed by Engineer-in-charge.
S&F in replacement VTPN DB 4 way double door type for fixing MCCB upto 200 Amps as incomer and MCB as out goinging with metal door and IP 43 protetions & connecting complete all as specified and directed by Engineer-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-2 Way, 240V without busbar complete all as specified and directed by Engineer-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-4 Way, 240V without busbar complete all as specified and directed by Engineer-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-8 Way, 240V with 200 Amp rated busbar complete all as specified and directed by Engineer-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-12 Way, 240V with 200 Amp rated busbar complete all as specified and directed by Engineer-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-16 Way, 240V with 200 Amp rated busbar complete complete all as specified and directed by Engineer-in-charge.
S&F in replacement single pole and neutral metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 16 Amps as per site requirement of existing type for geyser complete all as specified and directed by Engineer-in-charge.
S&F in replacement single pole and neutral metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 32 Amps as per site requirement of existing type for ACs complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCCB 160 Amps 3 pole 415 volts fixed type with breaking capacity 36 KA 415 volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCCB 125 Amps 3 pole 415 volts fixed type with breaking capacity 36 KA 415 volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB TPN/ 4 Pole 63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB TPN/ 4 Pole 100 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB TP 3 Pole 63Amps 240 volts, 'C' Series as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB SPN 63 Amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB SPN 40 Amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB SPN 32Amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB SP 6 to 32 Amps 240 Volts, 10kA, `C' curve all as per site requirement complete all as specified and directed by Engineer-in-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, Electric bell, lamp holder, bell push etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) and making good to disturbed surface of walls including necessary touch up with thw adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engineer-in-charge. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per item No 20 above but One 3 pin socket outlet, 5/6 Amps, independent, with cables 1.5 sq. mm size with through existing concealed PVC/MS conduit.
All as per item No 20 above but 5 Amp socket outlet on same board.
All as Item No 20 above but for one socket outlet 5/15 Amps on Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit.
All as Item No 20 above but for one socket outlet 5/15 Amps on Independent board with cables 4 sqmm size for phase and neutral and 4 Sqmm for earthing with through existing concealed PVC/MS conduit.
All as Item No 20 above but for one One light controlled by 2-way switches using cable of 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing with through existing concealed PVC/MS conduit.
S&F of switch piano flush type 5/6 Amps SP one way complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type 5/6 Amps SP two way complete all as specified and directed by Engineer-in-charge.
S&F bell push, flush type 5/6 Amps complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engineer-in-charge.
S&F of switch piano 15/16 Amps SP one way complete all as specified and directed by Engineer-in-charge.
S&F of universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and directed by Engineer-in-charge.
S&F 0-4 step type electronic regulators for ceiling fan 1200/1400 mm sweep, 240V complete all as specified and directed by Engineer-in-charge.
S&F lamp holder Angle/Batten Type bakelite insulated body with back plate suitable for batten fitting complete all as specified and directed by Engineer-in-charge.
S&F Electric bell ding dong any type with fliexble wire complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Engineer-in-charge.
S&F wal mounted LED Integrated batten T5 20Watt -4ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 36/40Watt FTL fitting any type, complete all as specified and directed by Engineer-in-charge.
S&F wal mounted LED Integrated batten T5 10Watt -2ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 18/14 watt FTL fitting any type, complete all as specified and directed by Engineer-in-charge.
S&F Surface mounting Round/ Square shaped LED downlighter 6 Watt any type complete with including new fliexble wire as required on site in replacement of old unsv existing ceiling light fitting complete all as specified and directed by Engineer-in-charge.
S&F in replacement LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including required LED bulb and all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and directed by Engineer-in-charge.
S&F in replacement of LED Building security light fitting 30 Watts and fitting any type, from existing bracket with and including replacement of unsv bolts, nuts and washers etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement GI pipe's bracket suitable for fixing of bldg security LED light fitting of 35 Watts including grouting and fixing the same on wall for installation of light fitting with necessary clamps, nut, bolts & washer and painting by synthetic enameled good quality paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket Note : GI pipe should be 40 mm bore dia with medium grade and the same to be moulded in 45 degree angle at the 1 Mtr height to fix the building security light fitting)
S&F Recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire Complete all as specified and directed by Engineer-in-charge.
S&F in replacement earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI wire 4 mm as earthing lead by means of nut, bolts and check nuts and washers, GI light grade protection pipe 15 mm dia upto 7.5 M, GI watering pipe 20 mm dia medium grade, RCC cover with funnel, excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 03 of SSR Part I, including earth test point upto panel board, all as specified or indicated including testing on completion Complete all as specified and directed by Engineer-in-charge.
S&F in rerplacement submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 10 Sqmm in 2 runs and 06 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit Complete all as specified and directed by Engineer-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in rerplacement submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 6 Sqmm in 2 runs and 06 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit Complete all as specified and directed by Engineer-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in rerplacement submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 4 Sqmm in 2 runs and 04 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit Complete all as specified and directed by Engineer-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all-toghter shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
M/s KUNDU CONSTRUCTION
Ish Engineers and Contractors
Microsys Controls India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .