Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.3 L+₹83,225 (4.77%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹19.5 L+₹2.0 L (11.5%)Rejected-AOC 205L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | L3 | Rejected-AOC L3 | |
| 4 | L4₹20.7 L+₹3.2 L (18.5%)Rejected-AOC 0 0 MOH SITARGANJ PIPRI POST UKHLI KATRA SHAHJAHANPUR UTTAR PRADESH 242301 SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242301 | SHAHJAHANPUR | UTTAR PRADESH | 242301 | L4 | Rejected-AOC L4 | |
| 5 | L5₹23.8 L+₹6.3 L (36.4%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
25 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
Kanjoli line Bhararpur
Repair/Replacement of Old Unsv flame proof light fitting and flame proof DB in 39 FAD at Mil Stn Bharatpur
2022_MES_527568_2
8159/E8
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
as per tender document
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹40,000
Yes
13 Aug 2022
6 Jul 2022
27 Jul 2022
6 Jul 2022
25 Jul 2022
11 Jul 2022
7 Jul 2022 - 9 Jul 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete.
Demolition of Concrete in ground floors and pavings not exc 15cm thick( below or above ground floors) complete all as specified and as directed.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid and tested complete.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm. Note : Punned thickness shall be measured
Supply and laying of sub class 'B' bricks in trenches over cables for protection cover across the length of cable complete all as specified and directed.
M&L for driling hole in hard standing / road for laying of pipe for protection of cable etc by adopting method of horizontal manual drilling (trenchless technology) without disturbing the top surface or cutting and making good the disturbed surface to the existing surface.
Supply and laying in replacement of GI tube light grade 40 mm bore complete.
Taking out and Supply & laying LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sqmm 4 core sizes in trenches /passing through pipes/ on poles etc complele all as specified and directed.
Supply & Fix & connecting totally enclosed CMRI Certified in replacement of LED flameproof wellglass suitable for hazardous area laden with gases or vapours of Group IIA & IIB and Zone 1&2. Die Cast Aluminum housing with heat resistant toughened glass cemented into a retaining ring fixed with screws to the main housing external reflector 40W including matching control gears and lamp complete of Cat Part No FWL1315-40-CDL/HB lamp of Crompton Greaves or equivalent model of Flexpro/Shyaam switchgear (P) Limited/Philips.
Taking down of old unserviceable copper / aluminium point wiring (light) with conduit complete including fitting & fixture such as switches, ceiling roses, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors etc complete.
All as per Ser item No 11 Above but without conduit
Taking down old unserviceable sub main wiring of any size complete all as specified and as directed.
All as per Ser item No 13 Above but without conduit
M&L concealed point wiring complete with two runs of 2.5 sqmm, single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable, 1100volts grade IS-694 marked drawn through and including rigid steel ERW conduit min 20mm dia ( stove enameled) heavy duty as per IS 9537 Part I and including all necessary flame proof , weather proof conduit accessories and fitting fixed to concealed in wall/ceiling with teflon tape sealed in all threaded joints in conduit and fittings for light points and including 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade earth continuity wire (connecting to earth dolly) & wiring shall be done as per STEC-7 for the following :- Two light points controlled by one switch/MCB
One light points controlled by one switch/MCB
All as per Ser item No 15 Above but for Two light points controlled by one switch/MCB with copper cables 2.5 sqmm size. (in existing conduit)
All as per Ser item No 15 Above but for one light points controlled by one switch/MCB with copper cables 2.5 sqmm size. (in existing conduit)
Supply and fixing in replacement of factory made mild steel flame froof distribution boards, class LM-6 , protection class (IP-55) CMRI certified suitable for gas group IIA & IIB suitable for mounting MCB/RCCBs, DBs TP&N 4 way, 415 volts conforming to IS-2143 with minimum 200A rating copper bus bar Comprising of following :- (i) Lighting distribution panel (ii) Incoming: - MCB , 4P 63AMP - 01 Nos (iii) Outgoing :- MCB, 1P, 6AMP -12Nos (MCB - L&T/Schneider or equivalent make) with complete internal Bus bar & wiring up to terminals. Make :- Cat part No SSPL/RCP/109 of Shyaam switchgear (P) Ltd or equivalent Model of Crompton Greaves/Philips/L& T as approved by GE complete all as specified and directed.
Supply and fixing in replacement of switch flame proof rotary type with termination box in LM6, 16 Amps single pole, 250 volts epoxy painted.
Supply and fixing in replacement of switch flame proof rotary type with termination box in LM6, 25 Amps double pole, 250 volts epoxy painted.
Supply and fixing in replacement of LED flameproof tube light fitting CMRI certified 1x20W LED tube light fixture complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat Part No SSPL/FF/1271 lamp of Shyaam switchgear (P) Limited or equivalent model of flexpro/Crompton Greaves/Phillips as approved by GE complete all as specified and directed.
Supply and fixing in replacement of LED flameproof tube light fitting CMRI certified 2x20W LED tube light fixture complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat Part No SSPL/FF/1271 lamp of Shyaam switchgear (P) Limited or equivalent model of flexpro/Crompton Greaves/Phillips as approved by GE complete all as specified and directed.
Supply and fixing in replacement of MCB SPN 6 amp, 10KA rupturing capacity class-c (ISI marked IS -8828) fixing in DBs complete all as specified and directed.
Supply and fixing in replacement of MCB SPN 16 amp, 10KA rupturing capacity class-c (ISI marked IS -8828) fixing in DBs complete all as specified and directed.
Supply and fixing in replacement of MCB TPN 32 amp, 10KA rupturing capacity class-c (ISI marked IS -8828) fixing in DBs complete all as specified and directed.
M&L sub main wiring with two runs of single core PVC insulated but unsheathed FRLS cable of 2.5 sqmm with multi stranded copper conductors, 1100 volts grade, IS-694 marked , drawn-through rigid steel ERW conduit (stove enameled) 20 mm dia heavy duty and including suitable size and fittings/accessories, concealed in wall and also including the one run of 2.5 sqmm earth continuity conductor of similar type cable complete all as specified and directed. Note :- Two runs of single core of 2.5 sqmm, one run of 2.5 sqmm earth continuity conductors and one run of 20mm dia ERW conduit with accessories shall be measured as one unit run length.
Sub main wiring with two runs of single core PVC insulated but unsheathed FRLS cable of 2.5 sqmm with multi stranded copper conductors, 1100 volts IS-694 marked including the one run of 2.5 sqmm earth continuity conductor of similar type cable in existing conduit drawn through complete all as specified and directed. Note :- Two runs of single core of 2.5 sqmm and one run of 2.5 sqmm earth continuity conductors with accessories shall be measured as one unit run length.
M & L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 20mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of funnel pipe of 20 mm GI light grade pipe and protection pipe of 20mm bore GI light grade is deemed to be included in quoted unit rate including taking out old unserviceable earthing
Taking down of old unserviceable optical type smoke detector and supply,fixing and testing of detectors complying with and type certified to EN-45 adjustable type smoke detector Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed . Make Cooper/Honeywell/Ravel/Apollo
M&L in replacement for 2 run of 1.5 sqmm single core PVC insulated sheathed ISI marked FRLS copper conductor multi stranded 1100 volt grade cable of 01 run of 1.5 Sqmm earth continuity conductor of similar type cable drawn through existing conduit connecting and testing all as specified and directed.
Supply & Fix in replacement for addressable manual call point resettable type.
Taking out old unsv electric siron/hooter of capacity 1.0KM to 3.5KM complete and rewinding the same with existing guage copper wire and servicing and replacement of old unserviceable parts to make functional as per OEM direction complete all as specified and directed. Note: - Cost of parts required for replacement is deemed to be inclusive in quoted rates
M/S SHRINATH CONTRACTION
M/s S. K. Construction Co.
M/s Gupta Traders
krishna Associate
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .