Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.1 L+₹1.3 L (6.89%)Rejected-Finance | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹20.7 L+₹1.9 L (9.84%)Rejected-Finance 2 8 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹21.6 L+₹2.8 L (14.9%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L4 | Rejected-Finance BIDDER NOT LOWEST | |
| 5 | L5₹22.5 L+₹3.7 L (19.8%)Rejected-Finance | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹48.6 L
EMD Value
₹97,280
Closing Date
28 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
COMPREHENSIVE MAINTENANCE OF E M NATURE OF WORKS IN CARIAPPA VIHAR MT LINE UNDER GE WEST DELHI CANTT 10
2022_MES_520770_1
GE/DW-49/2022-23
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹97,280
9 Sept 2022
25 May 2022
30 Jul 2022
26 May 2022
28 Jul 2022
7 Jul 2022
90 days
Amount
Checking and attending complaints by experience tradesman means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES daily except national holidays AT Cariappa Vihar & MT Line area complete all as specified and directed. Note: 1. This item covers cost of labour for attending complaint comprising taking down of old material and fixing of any item issued by the Deptt. 2. Complaints noted'' NO Light,Short circuit,Sparking,Burning etc issues in electric circuits shall be attended imediately up to 2200 hrs on same day without fail, failing which recovery of Rs. 240.00 per complaint shall be effected from the contractor's dues. 3. Minor items as electric tape,screws,nut & bolts,washers, etc shall deemed to be included in the quoted rate of this item. 4.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, which is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding. 5. Contractor shall arrange suitable T&P incl necessary from work and scaffolding and safety measures to make it functional complete all as specified and directed. 6. Contractor or his rep will report daily at complaint cell at cariappa Vihar for collection of complaints from the concerned JE in charge . 7 Job slip as per sample shall be provided by the contractor free of cost. 8. The contractor is advised to inspect site and to note that he has to deploy daily men power to collect the complaints from complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account. 9.All Items Required to replace such as switches,sockets,call bells,Bell push,Capacitors,Plug Tops,Metal clad sockets,ceiling roses,light fittings,fan regulators,MCBs,MCB DB's,MCCB's,security lights,all materials except fixing accessories etc any capacity shall be measured and paid seperately and no labour charges shall be paid under respect items of this BOQ 10.Item required to replace in repairs based on Day to Day complaints by the users as when as required as site. 11.Old unserviceable material obtained from site against issued by the department to be deposited to MES store Yard. 12. No of experience tradesman to be deployed will be not less than three or as decided by the Engr-in-Charge for smooth functioning of the station. 13. Labour charges for this item shall not be included under items which includes 'M&L','S&F' in repair',fixing only /Fixing in repair etc in respective item of this Schedule/BOQ.
Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc.complete all as specified and directed.
M&L point wiring in existing conduit with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing in & including rigid PVC conduit FRLS grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly and making good to the disturb surfaces with cement, matching with existing color by painting all as specified for the following :-
(a) One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely)
(b) One light point controlled by two, two way switch ( switch to be measured and paid separtely)
(c) One 3 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
(d) -ditto- as above item No 4 but Same board.
M&L One power point in existing conduit with insulated stranded copper conductor cable 2.5 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 1.5 Sqmm stranded conductor as earth wire connected to dolly complete ( socket and switches to be measured and paid separately)
M&L point wiring concealed in wall with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing in & including rigid PVC conduit FRLS grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly and making good to the disturb surfaces with cement, matching with existing color by painting all as specified for the following :-
(a) One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely)
(b) One light point controlled by two, two way switch ( switch to be measured and paid separtely)
(c) One 3 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
(d) -ditto- as above item No 10 but Same board.
M&L One power point concealed in wall with insulated stranded copper conductor cable 2.5 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 1.5 Sqmm stranded conductor as earth wire including PVC cunduit connected to dolly complete all as specified. ( socket and switches to be measured and paid separately)
M & L for One light point or one fan or bell point controlled by one switch with, with cables 1.5 sq. mm size PVC insulated and unsheathed cable 1.5 sq mm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 all as specified including PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same conduit on surface of wall/ceiling in PVC conduit pipe/casing & caping with saddle and nut,screw with high strength PVC end terminal box and cover sheet to mount one piano type 5 Amp switch as required complete all as specified and directed. . Note: switch to be measured and paid separately.
M & L for One 3 pin socket outlet, 5 Amps, independent,with cables 1.5 sq. mm size PVC insulated and unsheathed cable 1.5 sq mm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 all as specified including PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same conduit on surface of wall/ceiling in PVC conduit pipe/casing & caping with saddle and nut,screw with high strength PVC end terminal box and cover sheet to mount one piano type 5 Amp switch and 3 pin 5 Amp socket as required complete all as specified and directed. Note: switch & socket to be measured and paid separately.
M & L for One 3 pin socket outlet, 15 Amps, independent,with cables 2.5 sq. mm size PVC insulated and unsheathed cable 2.5 sq mm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 all as specified including PVC insulated and unsheathed cable 2.5 Sqmm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same conduit on surface of wall/ceiling in PVC conduit pipe/casing & caping with saddle and nut,screw with high strength PVC end terminal box and cover sheet to mount one piano type 15 Amp switch and 3 pin 15 Amp socket as required complete all as specified and directed. Note:switch & socket to be measured and paid separately.
M&L switch piano flush type 5 Amp SP one way complete all as specified and directed.
M&L switch piano flush type 5 Amp SP two way complete all as specified and directed.
M&L switch piano flush type 15 Amp SP one way complete all as specified and directed.
M&L socket outlet 5 pin 5 Amp flush type complete all as specified and directed.
M&L socket outlet 2 in 1,3 pin 5/15 Amps complete all as specified and directed.
M&L ceiling rose 3 phase PVC polycorbonate,insulated body complete all as specified and directed.
M&L electronic fan regulator 5 step connecting complete all as specified .
M&L bell push,flush type,5 amp complete all as specified and directed.
M&L bell ding dong AC,230 volts,single pole complete all as specified and directed.
M/L insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
S&F in repair GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 25mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including clamps, nuts, bolts and washers etc complete all as specified by the Engr-in-Charge .
Supply and fix submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 4 Sqmm size stranded conductor as earthwire including taking out old submain wiring complete all as specified and directed.
Supply and fix submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 10 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 6 Sqmm size stranded conductor as earthwire including taking out old submain wiring complete all as specified and directed.
M & L in repair earthing complete with copper earth plate 600x600x3.15mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to 20x3mm copper strip by means of bolts, nuts, check nuts and washers of copper strip and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 40mm bore for copper strip, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) with MS handle and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing on completion all as directed .
M&L LT panel bus bar copper strip 20 x 3 mm as panel internal electrical connections complete all as directed including taking down the old unserviceable complete all as specified and directed.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation using GI strip 25 x 4 mm as earthing lead complete all as directed including taking down the old unserviceable complete all as specified and directed.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire as earthing lead complete all as directed including taking down the old unserviceable complete all as specified and directed.
M&L in repair switch Modular type 6 Amps one way 230V AC as per sample complete all as specified.
M&L in repair switch Modular type 16 Amps one way 230V AC as per sample complete all as specified.
M&L in repair Modular socket outlet 5 pin 6 Amp socket 2 module as per sample complete all as specified.
M&L in repair switch bell push Modular type 6 Amps 1W-1 module, 230V AC as per sample complete all as specified.
M&L in repair Modular socket outlet 5 pin 16 Amp socket 2 module as per sample complete all as specified.
M&L in repair Modular fan regulator 2 module as per sample complete all as specified.
Supply & Fix in repair PVC round plate suitable for covers of junction boxes and joints of circuits with suitable screws complete all as specified and directed.
S&F in repair metal plug top 16 Amps 3 pin 230- volts complete all as specified.
S&F in repair metal plug socket 16 Amps 3 pin 230- volts complete all as specified.
Supply and fix in repair on load change over switch 200 Amp, 4 pole,415 Volts,with side handle dully fixed on wall with hole fastener, and making incoming and outgoing cable connections complete all as specified and directed.
Supply and fix in repair on load change over switch 100 Amp, 4 pole,415 Volts,with side handle dully fixed on wall with hole fastener, and making incoming and outgoing cable connections complete all as specified and directed.
S&F in repair BUS BAR cable juction box made out of CRCA sheet not less than 1.6 mm thick with 200Amp rated aluminium 3 phase bus bar including connecting all cable with thimble on bus rail including nut and bolt and all required accessories complete all as specified and directed by engr-in-charge complete all as specified and directed. .
M & L in repair hylum sheets 3 mm thick (ISI marked) of the following sizes :-
(a) Sheet 4" x 4" single cutting suitable for one piano switch
(b) Sheet 4" x 4" two cuttings suitable for two piano switches
(c) Sheet 4" x 7" three cuttings suitable for three piano switches
(d) Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
(e) Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
(f) Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
Taking down carefully ceiling/exhaust fan from its position after disconnecting electric connection and checking it for its serviceability and refixing after carrying out necessary repairs to fans/exhaust fans under respective items here-in-after and all as specified and directed.
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge complete all as specified and directed. .
M&L for opening up the winding of Exhaust fan 300/250/200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge complete all as specified and directed.
S&F exhaust fan blade of any make for size 225 mm to 450 mm sweep as per requirement at site complete all as specified and directed.(As per sample)
S&F ceiling fan blade 1200 mm sweep made up of aluminium body having provision of free size monting nuts/screw all as per requirement at site complete all as specified and directed.
S&F in repair canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers as per sample approved complete all as specified and directed.
S & F in repair down rod 300mm long with clamp ,nut bolt etc for mounting ceiling fan complete all as specified and directed.
S & F in repair down rod up to 1200mm long with clamp ,nut bolt etc for mounting ceiling fan complete all as specified and directed .
M&L for painting of ceiling fan 1200/1400 mm sweep complete with synthetic enamel paint by spraying includind filling cavities with filler, one coat after cleaning all dust complete all as specified and directed.
Supply and fix in repair PVC fresh air fan up to 250 mm motor as per sample complete all as specified and directed.
Supply and fix in repair PVC exhaust fan up to 300 mm motor as per sample complete all as specified and directed.
Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs complete all as directed. Note : Item require in repair except rubber gasket, nuts, bolts shall be paid seperately under respective items here-in-after complete all as specified and directed. .
M&L in repair of non-return valve 15/20mm dia (ISI Marked) for Geysers 50/35/25 Ltrs capacity including GI socket, nipple, elbow bend etc and connecting up complete all as specified and directed.
S&F in repair SS braided pipe of 12 mm (internal dia) suitable for hot/cold water, 450 mm long with brass nuts and rubber washers complete all as specified and directed.
S&F in repair SS braided pipe of 12 mm (internal dia) suitable for hot/cold water, 600 mm long with brass nuts and rubber washers complete all as specified and directed.
S&F in repair heating element of 2.0 KW triangular type with nut, bolt and washers complete all as specified and directed.
S&F in repair heating element of 2.0 KW circular type with nut, bolt and washers complete all as specified and directed.
S&F in repair thermostat of for 25/35/50 ltrs capacity of Geysers complete all as directed.
S&F in repair top cover for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site complete all as specified and directed.
S&F in repair bottom cover for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site complete all as specified and directed.
S&F in repair cover outer for Geysers (confirming to IS) suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed.
M&L for soldering and brazing inner copper tank of any capacity with brass solder and refixing complete (taking down and fixing shall be paid under ref item above) complete all as specified and directed.
S&F in repair stainless Steel inner tank of 25 Ltrs capacity as per sample complete all as specified and directed.
S&F in repair copper inner tank of 25 Ltrs capacity as per sample complete all as specified and directed.
S&F in repair stainless Steel flang assembly for geyser of 25 Ltrs capacity as per sample complete all as specified and directed.
S&F in repair of safety pressure valve of size 15 mm dia, with washer ISI marked for Geysers complete all as specified and directed.
S & F in repair hole fastner madeup of MS 6" long with complete nut bolt complete all as specified and directed.
S & F in repair hole fastner madeup of MS 4" long with complete nut bolt complete all as specified and directed.
M&L in repair for XLPE insulated, heavy duty under ground electric cable with stranded aluminium conductor,1100 volts grade of cross sectional area 25 Sqmm, 3.5 Core laid in trenches/fixing on wall/poles or passing through pipe including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing complete all as specified and directed.
M&L in repair for XLPE insulated, heavy duty under ground electric cable with stranded aluminium conductor,1100 volts grade of cross sectional area 35 Sqmm, 3.5 Core laid in trenches/fixing on wall/poles or passing through pipe including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing complete all as specified and directed.
M&L in repair for XLPE insulated, heavy duty under ground electric cable with stranded aluminium conductor,1100 volts grade of cross sectional area 16 Sqmm, 3 Core laid in trenches/fixing on wall (with GI Clamps and screws on wooden gutties)/poles or passing through pipe including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing complete all as specified and directed.
Supply & Fix Aluminum CABLE Lug 25 sqmm complete all as specified and directed.
Supply & Fix Aluminum CABLE Lug 35 sqmm complete all as specified and directed.
Supply & Fix Aluminum CABLE Lug 16 sqmm complete all as specified and directed.
M & L for cleaning of Electrical panel room,including taking out all dust,unused/unwanted garbage material from the panel room and dump it to the appropriate dumping place dully cleaned the panel room complete all as specified and directed.
M & L for Preparing old white wash surface of wall and ceilling of panal room size 5.0 M x 5.0 M x 3.10 M and applying two coats of white wash of existing colour complete all as specified and as directed.
S&F in repair PCC with steel reinforce trench cover of size not less than 600X450X60 MM in size including cleaning of trenches and cable, complete all as specified and directed as per sample complete all as specified and directed.
S & F in repair PVC casing caping along with Tee,bends,nut screw, connected items complete all as specified and directed.
S & F in repair PVC conduit with Tee,bends,nut screw,clamps, connected items complete all as specified and directed.
S & F in repair ceiling fan clamps complete all as specified and directed.
S & F in repair MS frame for exhaust fan up 300 mm sweep as per sample complete all as specified and directed.
S & F in repair MS frame exhaust fan 450 mm sweep as per sample complete all as specified and directed.
S & F in repair exhaust fan motor copper winding for 450 mm sweep as per sample complete all as specified and directed.
Supply and fix in repair repair distribution board TPN 4 way load line DBs IP 43-IK 09 With metal door suitable for MCCB 125 Amp as incomer and sp MCB as outgoing including 200 Amp rated bus bar,415 Volts fixed complete all as specified and directed.
M&L in repair MCB distribution board SPN 8 way with 200 Amp rated bus bar double door complete all as specified and directed.
Supply and fixing in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
(i) SP 5 To 32 AMP
(ii) SPN 32 AMP
(iii) SPN 40 to 63 AMP
Supply and fix in repair MCCB 125 Amps, 4 Pole 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed.
Supply and fixing in repair MCB given below ,415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
(i) TP 25 To 63 AMP
(ii) TPN 40 To 100 AMP
Supply and fix in repair MCCB 100 Amps, 4 Pole 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 317186.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
M/s S.G. BUILDERS
jain associates
M/s Adhikari construction co.
SETHI ENTERPRISES
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .