Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹38.3 L+₹2.4 L (6.73%)Rejected-AOC | L2 | Rejected-AOC Not being L1 bidder | |
| 3 | L3₹45.9 L+₹10.1 L (28.1%)Rejected-AOC | L3 | Rejected-AOC Not being L1 bidder |
| Sl No | Description | Qty | Unit | MOHAMMED MUMTAZ ENGINEERING WORKS L2 | Sri venkateswara Electricals L1 | M/s. A&T Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L Attending emergency breakdown of water supply installations where directed, Lifting up defective submersible pumpset of cap 5HP, 3 phase, 415 volts, any stage and deep, column pipes (any number) from bore well, setting aside and stacking column pipes for reuse, transportating unserviceable pumpset from borewell to workshop Opening of the defective motor & pump in MES store yard/ workshop, cleaning the covers and parts as applicable in presence of Engineer in Charge to ascertain the quantam of defects and repairs involved and assembling the motor & pump after carrying out repair works to make smooth functioning, applying spray painting to the repaired motor& pump externally with two coats of synthetic enamle paint of shade as directed by the Engineer in Charge transporting repaired pumpset from workshop to bore well site after completion of repair work, lowering of submersible pumpset with column pipes in the bore well as existing with new nut bolt and washer including rubber gasket 3 mm thick, including electrical supply connections as per existing for smooth functioning of pump motors complete all as specified and directed.
Note: Repair work of submersible pump set spares will measured and paid separately under respective items of this schedule. | 5 | Each | 4,500 ₹22,500 | 3,000 ₹15,000 Lowest | 7,000 ₹35,000 |
| 2.00 | All as per item 1 above here in before but for submersible pumpset and motor of capacity 7.5 HP. | 4 | Each | 5,400 ₹21,600 | 3,300 ₹13,200 Lowest | 8,500 ₹34,000 |
| 3.00 | All as per item 1 above here in before but for submersible pumpset and motor of capacity 10 HP.
Note for Sl. Item Nos. 1 to 3 :-
(i) Any spare parts required to replaced during repair, servicing, overhauling of motor, pump set etc shall be measured and paid separately under respective items of this schedule as supply only. Labour element involved in replacement of material shall deemed to included in the rates quoted.
(ii) Any minor repairs involved to make the motor, pump functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department.
(iii) In case of rewinding of stator of motor shall be measured and paid separately under respective item of this schedule.
(iv) Greasing/ oiling etc., of parts as required shall deemed to inclusive in the rate quoted. | 3 | Each | 6,300 ₹18,900 | 3,500 ₹10,500 Lowest | 9,500 ₹28,500 |
| 4.00Supply only the following spares required against Sl. Item No. 1, where required for submersible pumpset of capacity 5 HP as per the model and make as specified and directed by Engr-in-Charge :- | ||||||
| 4.01 | Water lubricant seal suitable for motor. | 3 | Each | 90 ₹270 | 80 ₹240 Lowest | 95 ₹285 |
| 4.02 | Thrust bearing for pumps | 4 | Each | 630 ₹2,520 | 110 ₹440 Lowest | 400 ₹1,600 |
| 4.03 | Bearing cover sleeve. | 2 | Each | 153 ₹306 | 80 ₹160 Lowest | 95 ₹190 |
| 4.04 | Thrust bearing for motors | 4 | Each | 630 ₹2,520 | 420 ₹1,680 Lowest | 750 ₹3,000 |
| 4.05 | Impeller fibre type | 5 | Each | 225 ₹1,125 | 200 ₹1,000 Lowest | 250 ₹1,250 |
| 4.06 | Neck ring | 3 | Each | 72 ₹216 Lowest | 80 ₹240 | 100 ₹300 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
2 Jan 2026, 6:00 pmClosed
GE Golconda
GE GOLCONDA LANGER HOUSE ROAD OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
REPAIR / MAINT OF PUMPS AND TANK CLEANING (OVERHEAD AND UNDERGROUND) AND REPAIR OF SUBMERSIBLE CENTRIFUGAL PUMPS AND REPAIR / MAINT OF 02 X 30 TR AC PLANT COLD STORAGE PLANT SPLIT AND WINDOW ACS UNDER THE AOR OF GE GOLCONDA
2025_MES_744304_1
8935/E8
Open Tender
Civil Works
Item Rate
180 days
GE GOLCONDA
As per Tender
9 documents required · 9 mandatory
₹500
GE Golconda
₹84,000
Yes
23 Feb 2026
12 Dec 2025
5 Jan 2026
12 Dec 2025
2 Jan 2026
26 Dec 2025
M&L Attending emergency breakdown of water supply installations where directed, Lifting up defective submersible pumpset of cap 5HP, 3 phase, 415 volts, any stage and deep, column pipes (any number) from bore well, setting aside and stacking column pipes for reuse, transportating unserviceable pumpset from borewell to workshop Opening of the defective motor & pump in MES store yard/ workshop, cleaning the covers and parts as applicable in presence of Engineer in Charge to ascertain the quantam of defects and repairs involved and assembling the motor & pump after carrying out repair works to make smooth functioning, applying spray painting to the repaired motor& pump externally with two coats of synthetic enamle paint of shade as directed by the Engineer in Charge transporting repaired pumpset from workshop to bore well site after completion of repair work, lowering of submersible pumpset with column pipes in the bore well as existing with new nut bolt and washer including rubber gasket 3 mm thick, including electrical supply connections as per existing for smooth functioning of pump motors complete all as specified and directed. Note: Repair work of submersible pump set spares will measured and paid separately under respective items of this schedule.
All as per item 1 above here in before but for submersible pumpset and motor of capacity 7.5 HP.
All as per item 1 above here in before but for submersible pumpset and motor of capacity 10 HP. Note for Sl. Item Nos. 1 to 3 :- (i) Any spare parts required to replaced during repair, servicing, overhauling of motor, pump set etc shall be measured and paid separately under respective items of this schedule as supply only. Labour element involved in replacement of material shall deemed to included in the rates quoted. (ii) Any minor repairs involved to make the motor, pump functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department. (iii) In case of rewinding of stator of motor shall be measured and paid separately under respective item of this schedule. (iv) Greasing/ oiling etc., of parts as required shall deemed to inclusive in the rate quoted.
Supply only the following spares required against Sl. Item No. 1, where required for submersible pumpset of capacity 5 HP as per the model and make as specified and directed by Engr-in-Charge :-
Water lubricant seal suitable for motor.
Thrust bearing for pumps
Bearing cover sleeve.
Thrust bearing for motors
Impeller fibre type
Neck ring
Stainless steel key for impeller shaft
Stainless steel motor - pump shaft coupler
Body bush for pump
Stainless steel sleeve for pump shaft
Pump shaft gun metal of appropriate size
Thrust pad
Rubber bushes to motor shaft.
Thrust plate
Supply only the following spares required against Sl. Item No. 2, where required for submersible pumpset of capacity 7.5 HP as per the model and make as specified and directed by Engr-in-Charge :-
Water lubricant seal suitable for motor.
Thrust bearing for pumps
Bearing cover sleeve.
Thrust bearing for motors
Impeller GM/PVC for 7.5HP submersible pump.
Neck ring
Stainless steel key for impeller shaft
Stainless steel motor - pump shaft coupler
Body bush for pump
Stainless steel sleeve for pump shaft
Pump shaft gun metal of appropriate size
Thrust pad
Rubber bushes to motor shaft.
Thrust plate
Supply only the following spares required against Sl. Item No. 3 where required for submersible pumpset of capacity 10 HP as per the model and make as specified and directed by Engr-in-Charge :-
Water lubricant seal suitable for motor.
Thrust bearing for pumps
Bearing cover sleeve.
Thrust bearing for motors
Impeller GM/PVC for 7.5HP submersible pump.
Neck ring
Stainless steel key for impeller shaft
Stainless steel motor - pump shaft coupler
Body bush for pump
Stainless steel sleeve for pump shaft
Pump shaft gun metal of appropriate size
Thrust pad
Rubber bushes to motor shaft.
Thrust plate
M&L Rewinding of stator of submersible motor of capacity 10 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed.
M&L Rewinding of stator of submersible motor of capacity 7.5 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed.
M&L Rewinding of stator of submersible motor of capacity 5 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed.
Servicing, overhauling of centrifugal pump, monoblock motor pump set of capacity 75 HP, 3 phase induction motor including carrying out maintenance check along including transportation with following repairs: (a) Dismantling of monoblock motor pump set in presence of MES representative and display all the parts without damage any portion for inspection of Engineer in Charge to ascertain the serviceability of existing parts. (b) Heating, varnishing to stator, rotor with super quality varnish and drying out properly with external heat. (c) Cleaning, washing of bearing and use right quantity of ball bearing grease for bearing. (d) Checking play of impeller and bushing of pump. (e) Assembling of motor with old serviceable parts and replacement of unserviceable parts with new as ordered where necessary. (f) Installation of motor by making connections as per existing and testing on load.
All as per item No. 10 above but for centrifugal pump, monoblock motor pump set of capacity 40 HP.
All as per item No. 10 above but for centrifugal pump, monoblock motor pump set of capacity 30 HP.
All as per item No. 10 above but for centrifugal pump, monoblock motor pump set of capacity 15 HP.
S & Fix indoor blower motor for split type AC of capacity 1.5/2.0 Ton as per existing model complete all as directed and taking out the old unserviceable one. Make : OEM
M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 75 HP with bare copper winding of appropriate gauge, all as specified and directed.
M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 40 HP with bare copper winding of appropriate gauge, all as specified and directed.
M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 30 HP with bare copper winding of appropriate gauge, all as specified and directed.
M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 15 HP with bare copper winding of appropriate gauge, all as specified and directed.
M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 10 HP with bare copper winding of appropriate gauge, all as specified and directed.
Supply only the following spare parts to incorporate against centrifugal monoblock motor pumpset of capacity 75 HP as required at site all as specified and directed.
Cast iron impeller
Ball/Thrust bearing suitable for different motor capacity as per existing.
Gland cup gun metal heavy duty.
Neck ring bush
Body bush
Thrust plate
Supply only the following spare parts to incorporate against centrifugal monoblock motor pumpset of capacity 40 HP as required at site all as specified and directed.
Cast iron impeller
Ball/Thrust bearing suitable for different motor capacity as per existing.
Gland cup gun metal heavy duty.
Neck ring bush
Body bush
Thrust plate
Supply only the following items to incorporate against centrifugal monoblock motor pumpset of capacity varying from 30 HP as required at site all as specified and directed:-
Cast iron impeller
Ball/Thrust bearing suitable for different motor capacity as per existing.
Gland cup gun metal heavy duty.
Neck ring bush
Body bush
Thrust plate
Supply only the following items to incorporate against centrifugal monoblock motor pumpset of capacity varying from 15 HP as required at site all as specified and directed:-
Cast iron impeller
Ball/Thrust bearing suitable for different motor capacity as per existing.
Gland cup gun metal heavy duty.
Neck ring bush
Body bush
Thrust plate
Supply only the following items to incorporate against centrifugal monoblock motor pumpset of capacity varying from 10 HP as required at site all as specified and directed:-
Cast iron impeller
Ball/Thrust bearing suitable for different motor capacity as per existing.
Gland cup gun metal heavy duty.
Neck ring bush
Body bush
Thrust plate
set of Two
All as per Item No:25 here-in-before but Over head tank of 25000 Gallon capacity at following location:- a) Near cook house 9 MT area/16 Dogra Regt 7th mile area at Arty Centre b) butchery, 40 JCOs patter bldg at Asif Nagar c) MH Golconda (near SHO office)
All as per Item No:25 here-in-before but Over head tank of 250000 Gallon capacity near CHQ main office area at Arty Centre.
All as per Item No:25 here-in-before but Over Head Tank capacity of 150000 Gallon at New 40 JCO' Pump House at Asif Nagar.
All as per Item No:25 here-in-before but Over head tank of 100000 Gallon capacity at following location:- a) 12 Jakli unit Area at Asif Nagar b) Offrs Md Accn (Near RSI) at MH/MD area and c) Signal Centre Pump House at MH/MD area
All as per Item No:25 here-in-before but Over head tank of 75000 Gallon capacity at 13 Dogra Area at Asif Nagar.
All as per Item No:25 here-in-before but Over head tank of 25000 Ltrs capacity at 60 ASC Supply Depot Unit Area.
All as per Item No:25 here-in-before but Over head tank of 10000 Ltrs capacity at 613 Missile Unit Area.
All as per Item No:25 here-in-before but cleaning of RCC under ground sump / semi under ground sump of following :-Semi under ground sump of capacity 50000 Gallon a) at Hanuman mandir PH and b)Outside MKD near Swimming pool PH at Arty Centre, c)64 ORs Map qtrs Area and Signal Centre Pump House and MAP Md Accn (near Signal Centre Pump House) at MH/MD Lines
All as per Item No:25 here-in-before but Semi under ground sump of capacity 30000 Gallon at Inside MKD PH/taramati Md Accn PH & Near Indoor Stadium 3 Trg Arty Centre.
All as per Item No:25 here-in-before but Semi under ground sump of capacity 15000 Gallon at 16 Dogra Regt PH & Pantathalom Stadium Outside MKD Arty Centre
All as per Item No:25 here-in-before but Semi under ground sump of capacity 10000 Gallon at :- a)Firing range PH/Inside MKD near Officers Md accn PH & IB line JCOs mess PH at Arty Centre and b) 28 JCO's pump house, 40 JCOS pattar bldg at Asif Nagar
All as per Item No:25 here-in-before but Semi under ground sump of capacity 250000 Gallon at IB line PH at Arty Centre.
All as per Item No:25 here-in-before but Semi under ground sump of capacity 300000 Gallon infront of 354 Fd Hosp area at Asif Nagar.
Taking down water level indicator unit from Over head reservoir/Semi Under ground sump, supply and fix new water level indicator with complete accessories such as copper ball, necessary pully, nylon rope, steel patti duly painted white with marking at every 10cm interval, letter writing of size 15mm width and 100mm long with signal red radium paint and painting of indicator with illumination postal red paint and errected at the height of 3 meter from ground level with necessary angle iron, nut and bolts complete all as specified and as directed by Engr-in-charge.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw including taking out old unserviceable one complete all as specified and as directed by Engr-in-charge.
S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long including taking out old unsserviceable one complete all as specified and as directed by Engr-in-charge.
Supply, laying, connecitng, testing and commissioning PVC insulated, PVC sheathed armoured, heavy duty electric power cable with multi stranded copper conductor, 1100 volts grade, of cross-sectional area 2.5 Sqmm 3 - core for aviation obstruction light of OH reservior upto 25m height including cutting to required lengths and connecting with necessary lugs and glands at both ends and taking out the existing burnt/ unserviceable one from panel/ starter complete all as specified and as directed by Engr-in-charge.
Supply and replace MCB DB DD 4 - way SPN 240 Volts and removig unserviceable materials out of site including connecting complete all as specified and as directed by Engr-in-charge.
Supply and replace existing unserviceble MCB SPN 5 - 30 Amps complete all as specified and as directed by Engr-in-charge.
Supply and replace aviation obstruction light aviation yellow painted die cast aluminium alloy housing built in heat resistant clear thick glass and accessories LED aviation obstruction light suitable to operate on 230 volts single phase AC supply complete on OH reservior complete all as specified and as directed by Engr-in-charge. Make:Bajaj/Philips/Wipro.
Disconnecting existing water level indicator, taking out defective MS wire rope from overhead tanks of any head, pulley, ball and replacing with new MS wire rope, ball of dia 300mm with provision for fixing wire, greasing and refixing both the pullies on another side as directed including marking the level on the indicator complete all as specified and as directed by Engr-in-charge.
S & F foot valve of 80 MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed by Engr-in-charge. Make : Kirloskar / Upadhaya
S & F foot valve of 100 MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed by Engr-in-charge. Make : Kirloskar / Upadhaya
S & F foot valve of 150 MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed by Engr-in-charge. Make : Kirloskar / Upadhaya
S & F Air release valve of 50 MM dia size to the exgisting CI/DI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed by Engr-in-charge. Make : Kirloskar / Upadhaya
Taking down UNSV Indoor unit of Split type AC of 1.5 TR capacity any make, model and S & F new indoor uint of same capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as directed. Make : OEM
S & F NRV of 100 MM dia size to the exgisting CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed by Engr-in-charge. Make : Kirloskar / Upadhaya
S & F NRV of 150 MM dia size to the exgisting CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed by Engr-in-charge. Make : Kirloskar / Upadhaya
S & F NRV of 200 MM dia size to the exgisting CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed by Engr-in-charge
. Make : Kirloskar / Upadhaya
Supply and fix in repair plastic jar for chlorine dosing complete all as specified and directed.
Cleaning of RCC Over Head Reservoir of capacity 50000 Glns as described below : i) Before starting the cleaning of Over Head Reservoir, distribution line from OH tank is to be disconnected and plugged with suitable fitting. After cleaning, plugged line should be washed out and connected to the distribution pipe line as per existing position. Cost of required earth work and excavation at places is deemed to be included in item rate quoted by the contractor. ii) The inner surface of the walls and ceiling of the tank shall be cleaned with high pressure jet pump after emptying the water in the tank. iii) After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed. iv) After removing the sludge from tank, the tank shall be first cleaned thoroughly by using high pressure water pump and again the floor and inner surfaces of the tank shall be cleaned by using a industrial vaccum cleaner and the tank shall be made fully dirt free. v) After making the tank dirt free, the inner surfaces of walls and ceiling of the tank shall be treated with anti bacterial agents. vi) After the treatment as mentioned at (iv) above, the inner surfaces of walls and ceiling shall be treated with UV Radiator. NOTE : (i) The unit rate quoted deemed to be including draining of water with mechanical equipment and working in water and mud etc. (ii) The unit rate quoted deemed to be inclusive of all safety precautions which shall be taken while working on RCC over head tank/underground sump and contractor or his Engineer shall be available during execution of the job. (iii) Lighting arrangements if required shall be provided by the contractor temporarily at his own arra
ngements and the rate quoted is deemed to be inclusive of this and electricity / diesel shall not be provided by the department. (iv) Contractor will not be allowed more than one day to do the work inside each OH tank/UG sump to precvent interruption of water supply to the users. Over head tank of 50000 Gallon capacity at a) hill top 9 MT area/Taramati Md Accn Pump house/Outside MKD near Swimming pool at Arty Centre b) 64 ORs Map qtr, Towli Chowki Qtrs/KVS - II, and Map Md Accn (near Signal Centre Pump House) at Asif Nagar and c) Old Md Lines (Near 19 Rajput Md Accn) at MH/MD Lines
Supply and fix in repair chlorine dosing pump system 6 BPH at 4 Bar complete all as specified and directed.
S&F for gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 50mm bore including taking down complete all as specified and directed.
S&F for gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 40mm bore including taking down complete all as specified and directed.
M&L for 150 mm dia Ductile iron pipes with spigot and socket end including tyton joints, Class K-9 laid in trenches alongwith taking taking up or down GI/CI/DI water mains 150mm dia (including all fittings) with spigot and socket ends and lead joints, burning out points and recovering lead complete all as specified and directed by Engr in Charge.
Material & Labour DI fittings for spigot/flanged end pipes such as bends any type (radius and angle) tapers any type (straight, bend increasing or decreasing double socket flanged etc), Tee pieces, single branch, 'Y' junction, double branch cross (all socket or socket and spigot or flanged, Collars,caps and plug etc all as specified and directed up to 250mm bore.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in Hard / Dense soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc.,25cm thick each layer in hard/dense soils all specified and as directed.
.Supply and lay galvanized steel water tubing medium grade of 50 mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions including taking up or down existing steel tubing with fittings all as specified and directed.
.Supply and lay galvanized steel water tubing medium grade of 40 mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions including taking up or down existing steel tubing with fittings all as specified and directed.
Removing excavated materials to a distance not exc 50 M and depositing where directed at a level not exc. 1.5 M above the starting point all as directed
Removing excavated materials to a distance not exc 50 M and depositing where directed at a level not exc. 1.5 M above the starting point all as directed
Supply and fix GI socket, heavy duty, 100mm long, 50mm bore, all as speecified and directed.
Supply and fix High density polyethylene pipes (HDPE) of pressure rating 16 kgf/cm2 of 50mm bore both end threaded alongwith fittings all as specified and directed.
Supply and fix High density polyethylene pipes (HDPE) of pressure rating 16 kgf/cm2 of 75mm bore both end threaded alongwith fittings all as specified and directed.
Supply, laying and testing 3 core 16 Sqmm, PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694, fixed to Centrifugal motor pump set to fully automatic starter, complete, including taking out old unserviceable cable of any description all as specified and directed.
Redevelopment of tube well of maximumm depth of 100 mtr by means of pumping by Air compressor of minimum pressure 10 Kg/cm2 (compressor to be arranged by contractor at his own cost), until sand free and clean water is obtained complete all as specified and directed.
Supply, laying and testing PVC insulated and sheathed flat 3 core 6 Sqmm, copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter, complete, including taking out old unserviceable cable of any description all as specified and directed.
Supply, laying and testing PVC insulated and sheathed flat 3 core 10 Sqmm, copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter, complete, including taking out old unserviceable cable of any description all as specified and directed.
S & F 3 pole power contactor, AC3 heavy duty 415 volts 25 A rating, with 2 NO+2NC, 240/415 Volts coil rating as per site requirement complete including taking down old unserviceable from the panel board/starter all as specified and direted.
S & F 3 pole power contactor, AC3 heavy duty 415 volts 40 A rating, with 2 NO+2NC, 240/415 Volts coil rating as per site requirement complete including taking down old unserviceable from the panel board/starter all as specified and direted.
S & F relay of DOL starter capacity 30 Amps as that of existing make and model including fixing in position connection, commissioning and testing complete, including taking down unserviceable over load relay all as specified and directed.
S&F Star delta starter timer capacity 30 Amps inlcuding taking down existing star delta starter timer, complete all as specified and directed.
S & F of DOL starter capacity up to30 Amps as that of existing make and model including fixing in position connection, commissioning and testing complete, including taking down unserviceable DOL starter all as specified and directed.
M & L for cutting of road, hard standing of approx depth 2 meter made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of pipe line all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Supply and fix out door unit fan motor with blade water proof type suitable for cold storage unit all as specified and directed by Engineer-in-Charge. Note :- The retreived materials have been mentioned in the Sch of credit in the tender documents in pdf form. The amount of Sch of credit will be deducted offline from the amount of BOQ at the time of acceptance. Note for Items (i) AC Mechanic should note down complaints from Complaint Register or Instruction by JE / Phone and complaints shall be attended at various locations of MH MD,Asif nager, and Arty center areas which are 5 kms from complaint cell & complaint should be completed within 4 days. Major/Compressor replacement complaints with in 6 days. (ii) Old UNSV compressors/motors will be handed over to contractor at the end of the Contract period by deshaping/ cutting them. (iii) AC Mechanic duties as measured in note (i) is deemed to be included in CA items.
AC PLANT: Leak testing of the system of the central A/C plant system of the following capacities with nitrogen (N2) pressure after evacuating of the existing refrigerant gas into the empty cylinders by separating the entire system such as compressor, condenser, refrigerant lines, evaporator etc, rectifying of the same b
y replacing the ‘O’ rings / teflon washers of suction / discharge / service valves, replacing the flair nuts etc, evacuating of the nitrogen from the system, vacuuming, recharging of taken out the refrigerant gas all as directed by Engineer-in-Charge for the capacities 34 TR.
Supply and lay galvanized steel water tubing medium grade of 80 mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions including taking up or down existing steel tubing with fittings all as specified and directed.
Supply and fix in repair steel water tubing, galvanised, heavy duty, 50 mm bore, column pipe, both ends threaded, incuding taking down existing pipe all as specified and directed.
Supply and fix in repair steel water tubing, galvanised, heavy duty, 40 mm bore, column pipe, both ends threaded, including taking down existing pipe all as specified and directed.
S & Fix Relay assembly and connecting with necessary wiring complete suitable for Window/Split type of AC 1.0/1.5/2.0 Ton Capacity and taking out the old unserviceable one. Make : Shriram /Renutraul / Voltas
S & Fix Over load protector complete suitable for Window/Split type AC of 1.0/105/2.0 Ton Capacity including removal of old Un Serviceable :-Make : Shriram /Renutraul / Voltas
S & Fix Thermostate set complete for window/split type AC of any make/model of Capacity 1.0/1.5/2.0 Ton including removing the old unserviceable Make – Renutraul/Annapurna/Usha
Rewinding of outdoor fan motor with same guage and turns and weight of copper enameled wire and replacement of bearing, testing and commissioning of 1.0/1.5/2.0 Ton split type AC of any make/ model complete all as directed.
S & Fix Copper capillary tube including strainer with necessary brazing, Leak Testing suitable for window /Split type AC 1 Ton to 2 Ton capacity and taking out the old unserviceable one.
All as per item No. 10 above but for centrifugal pump, monoblock motor pump set of capacity 10 HP. Note for Sl No 10 to 14: (i) Any spare parts required to replaced during servicing, overhauling of motor, pump set etc., shall be measured and paid for separately under respective items of this schedule as supply only. (ii) Labour element involved in replacement of spares shall deemed to be included in quoted rates against this item. (iii) Any minor repairs involved to make the motor, pump functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department. (iv) In case of rewinding of stator of motor shall be measured and paid separately under respective items of this schedule. (v) Greasing/ oiling etc of parts as required shall deemed to inclusive of rate quoted by the tendrer.
S & Fix Blower fan motor, with fixing arrangement complete operating on 215 / 240 Volts, single phase AC supply, multi speed suitable for Window AC 1/1.5/2.0 Ton capacity including taking out the old one. Make : OEM
S & F NRV of 80 MM dia size to the exgisting CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing all as specified and as directed by Engr-in-charge. Make : Kirloskar / Upadhaya
S & Fix Wiring kit for window type AC of 1.0/1.5/2.0 Ton capacity with copper wire PVC insulated single core of size1.5 sq mm, clips, terminal connector etc complete all as directed and taking out the old unserviceable one.
Servicing to the split type AC units of 1/1.5/2.0 ton capacity, cleaning of the evaporator coils externally with Caustic Soda / Chemical to remove the dust particles deposited on the cooling coil, cleaning of the condensing units to reduce the discharge pressure with the Caustic Soda / Chemical and testing complete all as directed.
Split Window AC Taking down carefully old burnt/unserviceable compressor unit of 1.0 ton capacity window type/Split type AC and replacing the same with New compressor including necessary accessories and mounting materials, welding, brazing, leak testing, vaccumissing and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete to any make of AC all as directed. Note:- Rate quoted shall be inclusive of R-22 refrigerant gas charging, testing and commissioning. Make : Kirloskar / Voltas/ LG/OEM
Servicing to the window type Air Conditioners of capacity 1/1.5/2.0 ton capacity, cleaning of the evaporator coil externally with Cautic Soda / chemical to remove the dust particles, cleaning of the filters and testing complete all as directed.
S & Fix Evaporator coil, including connected brazing welding work and provn of refrigerant suction/discharge line suitable for Window Ac / Split Type Ac 1.0/1.5 / 2.0 TR capacity including removing the unserviceable evaporator coil from the existing position all as directed.
All as per item No.119 above but rewinding, condensor fan varnishing, insulation, greasing , the mono-block pump set of 3 to 5 HP capacity except replacing of bearing all as directed by Engineer-in-Charge.
Supply, install , Testing and commissioning of 0.3 micron EU-14 HEPA Filters of outer size1220x610x150 mm with casing of aluminium foil and medis made of submicron glass fiber paper flange type with grill made out of stainless steel perforated sheet 20 SWG under the filters and taking out the old unserviceable one,complete all as specified and directed.
S & Fix capacitor of 36/45 MFD for Window/Split type AC's all as directed and taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON
S & Fix new remote control assembly for split type AC 1.5 /2.0 TR capacity including removing of the old unserviceable complete all as directed.
S & Fix PVC drain pipe 25 mm for rectifying water leakage from AC units complete all as directed and taking out the old unserviceable one.
All as per item No : 96 above but Split type AC of capacity 1.0/1.5/2.0 ton .
S & Fix copper tube of size 3/8, 5/8 inch dia includng necessary soldering , flooring and connecting and testing in between indoor to out door units of split type AC 1.5/2.0 Ton complete all as directed and taking out the old unserviceable one.
S & Fix insulation felt for split type AC 1.5 / 2.0 Ton copper tube inlet/outlet to out door unit up to 3 mtr in length complete all as directed.
Taking out unserviceable 1 Pole contactor from split AC and replacing the same with new contactor suitable for 240V,50Hz coil complete all as directed and taking out the old unserviceable one.
S & Fix Oscillation motor for the indoor unit of the split type AC of 1.5/2.0 Ton capacity complete all as directed and taking out the old unserviceable one.
Taking out unserviceable dummy nuts from the split AC units and S & Fix new Brass Dummy / Flare nuts of existing size complete all as directed and tak
S & Fix capacitor of 50/60 MFD for Window/Split type AC's all as directed and taking out the old unserviceable one. Make- CONCAP /BHEL/TIBCON
ing out the old unserviceable one.
All as per item No : 98 above but Split type AC of capacity 1.0/1.5/2.0 ton .
S & Fix Fan blade for 1.5/2 Ton capacity window/Split type ACs as per existing size/ model complete all as directed and taking out the old unserviceable one.
S & Fix Air Filter to the window /Split type Air Conditioners of 1/1.5 /2.0 Ton capacity and taking out the old unserviceable one all as specifed and directed.
Repairs to PCB of split type AC 1.5 /2.0 TR capacity including of replacement of electronic spares complete all as directed.
Disconnecting electrically and mechanically of the mono-block pump set of 3 to 5 HP capacity from the existing position by arranging dummy plates to suction and delivery line, removing from the existing position overhauling of the same, cleaning of the impeller, replacing the worn-out bearing, gland bush, gland nut, gland rope, greasing, re-fixing back and testing complete all as directed by Engineer-in-Charge.
Descaling of condenser of the capacities-34 TR by circulating descaling agent HCL through the condenser by forced feed method, removing the end covers of condensers, cleaning the each tube of condenser thoroughly by brushing, re-fixing back the end covers of the condenser by replacing the rubber gasket, nut, bolts, washers, cleaning of spares nozzles cooling tower, sump, water line, strainer and testing for normal working pressure complete all as specified and directed by Engineer-in-Charge. NOTE: After descaling the HP of the system should not be more than 200 psi, other wise descaling shall be again carried out with out any extra cost
Supply and fix Voltmeter 0 – 500 Volts capacity by disconnecting the electric connections and removing burnt out / unserviceable voltmeter 0 – 500 Volts, including reconnecting and testing complete all as directed by Engineer-in-Charge.
Supply and fix Ammeter 0 – 100 Amps capacity by disconnecting the electric connections and removing burnt out / unserviceable Ammeter 0 –100 Amps, including reconnecting and testing complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable pressure gauge and supply and fix pressure gauge of 100/150 mm size or equivalent all as specified and directed by Engineer-in-Charge.
Supply & Fixing the Temperature gauges in the chiller & AHU Water Pipe line complete with all accessries and as per sample all as specified and directed by Engineer-in-Charge.
Supply & Fixing of Dual plate check Valve Of size 65 mm Dia in the chilled Water pump Dischrage line With necessary Special Fitting and supports Complete with all accessries and as per sample all as specified and directed by Engineer-in-Charge.
Description all as per Item No-109 above but size of copper tubing 1/2, 1/4 inch dia complete all as directed.
Supply & Fixing of Rubber Expanion joint for chillers and pump of Size 65MM Dia With Necessary Special Fitting and support complete with all accessries and as per sample all as specified and directed by Engineer-in-Charge.
Removing unserviceable push button activator by disconnecting all the connections and supply and fix new push button activator, reconnecting and testing complete all as specified and directed by Engineer-in-charge.
M & L for VOLTAS / OEM company aouthorized Service Engineer to rectify software problem / Reset / Programming of Chiller Unit of AC Plant of Capacity 35 TR complete all as specified and directed by Engineer-in-charge.
Removing unserviceable temperature sensor and supply and fixing of temperaturer sensor of existing size complete all as specified and directed by Engineer-in-charge.
Supply and fixing of 32 Amps power contactor of suitable size as per the existing sample for compressor all as specified and directed by Engineer-in-Charge.
Supply and fixing water flow switch as per sample all as specified and directed by Engineer-in-Charge.
Servicing of air cooled condensor with coil cleaning chemical complete all as specified and directed by Engineer-in-Charge.
Cleaning of water chiller by circulatiing of Concentrate HCL chemical complete all as specified and directed by Engineer-in-Charge.
Servicing of AHU including cleaning of coil cleaning chemical and cleaning of 10 micron filter and 5 micron filter complete all as specified and directed by Engineer-in-Charge.
Servicing of chiller pumps like greasing and repalcing of gland rope minor consumable items commplete all as specified and directed by Engineer-in-Charge.
Supply and fixing of MN25 contactor all as specified and directed by Engineer-in-Charge.
Supply and fixng of catch all filter of suitable size for chiller all as specified and directed by Engineer-in-Charge.
Supply and filling refregerant gas A- 407 C all as specified and directed by Engineer-in-Charge.
Removing of unserviceable/burnt out DOL starters by disconnecting all the cable connections connection supply and fix new DOL starter (MK-1) including reconnection and testing complete all as specified and directed by Engineer-in-Charge.
All as per item No : 84 above but for Window/Split type AC 1.50 Ton Capacity
Supply and fix Indicating lamps (RYB) phase (Set of three) – 01 set all as specified and directed by Engineer-in-Charge.
Supplay and Fix Voltas scroll chiller 4.3 inch Touch DisplayHMI Standrad 35 TR
Supply and fix AC contactor 32 Amps, 3 phase ,415 volts, 50 Hz suitable for cold storage all as specified and directed by Engineer-in-Charge.
Cleaning of the evaporator coils of the capacities(1.5X4) TR with cleaning acid by forced feed method to remove the unwanted dust particles formed on the coil and fins, cleaning of the dust particles, parts of periodical maintenance, cleaning of liquid lines, strainer, expansion valve etc. and testing complete all as specified and directed by Engineer-in-Charge.
Cleaning the unit with CTC except evaporator and condensor and leak testing the system with Nitrogen gas and detecting the leak and repairing, brazing and sealing the leakage including charging the refrigerant R-22 gas to the required pressure and weight of gas for 1.0/1.5/2.0 Ton capacity window type ACof any make complete all as directed Note :- Gas charging will be measured separately against relevant item of this schedule.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.39 MB
8935Tender.pdf
Tender Documents • 0.64 MB
8935Makes.pdf
Additional Documents • 0.56 MB
8935NIT.pdf
Additional Documents • 0.37 MB
BOQ_833430.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .