Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.3 LAccepted-AOC A 99 SECTOR 4 AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC BEING L1. | |
| 2 | L2₹81.9 L+₹2.5 L (3.21%)Rejected-Finance C 1 YUKON ENTERPRISES PRIVATE LIMITED INDUSTRIAL ESTATE INDUSTRIAL ESTATE SUNDERGARH ODISHA 769004 | SUNDARGARH | ODISHA | 769004 | L2 | Rejected-Finance BEING L2. |
Tender Value
₹98.8 L
EMD Value
₹1.2 L
Closing Date
4 Apr 2023, 5:00 pmClosed
General Manager(CSR, Welfare and TA)HOD
Office of General Manager(CSR, Welfare and TA)HOD, MCL HQ, Burla
Design, Supply, Installation, testing, commissioning and operation of minimum 131 TR (total) HVAC Air Cooled Package System with control panel including 5 years CAMC after 1 year warranty period on turnkey basis at Kalyan Mandap, Anand Vihar, MCL HQ
2023_MCL_272299_1
MCL/SAMB/ENM/e-Tender/ 2022-23/288 Dt.02/03/2023
Open Tender
Miscellaneous Works
Item Rate
2250 days
Kalyan Mandap, Anand Vihar, MCL HQ, Burla.
As per NIT
6 documents required · 6 mandatory
₹1.2 L
Office of General Manager(CSR, Welfare and TA)HOD
30 Sept 2023
2 Mar 2023
10 Apr 2023
3 Mar 2023
4 Apr 2023
15 Mar 2023
3 Mar 2023 - 24 Mar 2023
10 Mar 2023
Amount
DESIGN AND SUPPLY COST
(1) Complete Design & Engineering of the system/Plant. (2) Supply of inverter floor Mounted Package AC with multiple combination TR capacity having minimum 131 TR (total). ODU Hermitically sealed inverter Scroll with Fixed Speed compressor and Condenser/Heat exchanger should be design for better efficiency. All units must be compatible with R410 Refrigerant Gas / Environment friendly gas. (a) 22.0 TR (Inverter package AC) (4 Quantity) - minimum of 88 TR capacity inverter package AC for Kalyan Mandap Hall (b) 16.5 TR (Inverter package AC) (2 Quantity) - minimum of 33 TR capacity inverter package AC for Dining Hall (c) 5.0 TR (Inverter package AC) (2 Quantity) - minimum of 5 TR capacity inverter package AC for each Mandap and stage (3) Supply of copper Refrigerant Pipe complete with nitrile tubular insulation between indoor and outdoor units as per specifications/Standards. (4) Supply of communication cable in PVC conduit between Indoor Unit/Outdoor unit. (a) 6 core X 1.5 Sqmm & 3 core X 1.5 Sqmm. (5) 6mm THICK NITRIEL RUBBER insulated condensate Water Drain piping constructed out of PVC/HDPE hard pipes, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors Fastners. (a) 32 mm (6) Supply & filling of Refrigerant Gas into the Ac system. (a) R-R410 / Environment friendly gas. (7) VI pad for Outdoor Units placements. (8) Supply of following gauge of Galvanised Iron (GI) Sheet complete with supports, clamps, frames, etc. as required. (a) 20 G (b) 22 G (c) 24 G (9) Supply of Acoustic Insulation with rigid Board & 30 G Aluminium Net inside of site Fabricated Duct System. (a) 12 mm rigid Board (48 Kg Density) (10) Supply of Nitrile Insulation (Class-1) (a) 13 mm (11) Supply of Aluminium powder-coated Grill (a) Supply Air Grill with VCD and Damper (b) Return Air Grill without VCD (12) Canvas Connection
Cable Tray and Earthing system
Electrical Panel with required Cables having 01 no. incommer MCCB & 10 nos. outgoing MCCB of suitable rating including meetering & protection facility.
Installation, testing and Commissioning Work
(1) Installaion, Testing and commissioning of inverter floor Mounted Package AC system with multiple combination TR capacity having minimum 131 TR (total). (a) 22.0 TR (Inverter package AC) (4 Quantity) (b) 16.5 TR (Inverter package AC) (2 Quantity) (c) 5.0 TR (Inverter package AC) (2 Quantity) (2) Installaion, Testing and commissioning of copper Refrigerant Pipe complete with nitrile tubular insulation between indoor and outdoor units as per specifications/Standards. (3) Installaion, Testing and commissioning of communication cable in PVC conduit between Indoor Unit/Outdoor unit. (a) 6 core X 1.5 Sqmm & 3 core X 1.5 Sqmm. (4) Installation, testing & Commissioning of following gauge of Galvanised Iron(GI) Sheet complete with supports, clamps, frames, etc. as required. (a) 20 G (b) 22 G (c) 24 G (5) Installation of Acoustic Insulation with rigid Board & 30 G Aluminium Net inside of site Fabricated Duct System. (a) 12 mm rigid Board (48 Kg Density) (6) Installaion, Testing and commissioning of Nitrile Insulation (Class-1) (a) 13 mm (7) Installation of Aluminium powder-coated Grill (a) Supply Air Grill with VCD and Damper (b) Return Air Grill without VCD
Fabrication Work
Fabrication of duct of following gauge of Galvanised Iron(GI) Sheet complete with supports, clamps, frames, etc. as required. (a) 20 G (b) 22 G (c) 24 G
COMPREHENSIVE ANNUAL OPERATION, MAINTENANCE CONTRACT
Comprehensive Annual operation & Maintenance Contract for 5 years (after 1 year warranty) and operation during warranty period (one Trained operator as and when required) for minimum 131 TR (total) inverter floor Mounted Package Ac system.
Total impact of GST for the purpose of CTC
YUKON ENTERPRISES PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .