Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹8.3 L+₹2.2 L (35.6%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹8.6 L+₹2.6 L (41.9%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹8.7 L+₹2.6 L (43.2%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹8.8 L+₹2.7 L (44.5%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Garrison Engineer Dronachal
GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038
REPAIR AND MAINTENANCE OF PACKAGE AC, SPLIT AC, DEEP FREEZERS, WATER COOLERS AND DESERT COOLERS AT DRONACHAL BHOPAL
2023_MES_575203_1
8747/E8
Open Tender
Civil Works
Item Rate
180 days
Bhopal
Class-E, Category c (i) and as per NIT documents
6 documents required · 6 mandatory
₹500
Garrison Engineer Dronachal
₹20,000
Yes
27 Apr 2023
16 Jan 2023
15 Feb 2023
16 Jan 2023
13 Feb 2023
31 Jan 2023
16 Jan 2023 - 30 Jan 2023
Amount
M&L for servicing package type AC plant of 11 TR capacity of make Blue star with greasing of motor bearings, replacement of belts, adjustment of tension of belt, cleaning of all filters, checking of complete wiring, topup of gas (Refrigerant), tightening of nut bolts, oiling and greasing of all movable parts comp[lete all as specified and up the satisfaction of Engr-in-Charge. (Note : Cost of belt, Refrigerant gas and lubricant etc required for servicing is deem to be included in unit rate and no extra cost will be paid for this separately).
Replacement of aluminium fan Blade for condensing fan motor of capacity 11TR capacity.
Replacement of alumium fan blower for cooling fan motor of capacity 11TR capacity.
Foam type insulating flexible pipe fitted on suction/discharge copper tubes.
S&F condenser fan motor of ductable type AC of capacity 11 TR as per existing make and model complete all as specified and directed.
S&F cooling fan motor of ductable split type as per existing make and model of capacity 11 TR complete all as specified and directed.
S & F in repairs starting/running capacitor, suitable for ductable type AC of capacity 11 TR complete all as specified and directed.
Disconnecting Dismantllng and removing of U/S condensor unit coil and S/F in replecement of condensor coil unit including connection of copper tubing for of ductable type AC 11 TR capacity complete all as specified and directed.
Disconnecting dismantling and removing of U/S cooling coil from indoor unit complete and supplying and fixing of new indoor cooling coil unit of ductable type AC of capacity of 11 TR, including connection of copper tubing complete all as specified and directed.
S&F in repaired Rotary type Compressor of package type AC plant of 5.5 TR capacity with starting and running capacity and relay including connection of copper tubing and topping up of refrigerant gas for smooth functioning ,complete all as specified and directed.
Supply and topping up of Refrigerant gas R-407 in air conditioner at different site as required including brazing and removal of leakage in equipment
M & L for wall mounted Stablizer of capacity 2 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as specified and directed.
M & L for wall mounted Stablizer of capacity 5 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as specified and directed.
S & F in repairs PCB Senser unit with wire remotre control of ductable AC indoor unit of Capacity 11 TR for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as specified and directed.
M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLS PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 4.0 sqmm and 1 x 4.0 sqmm for earth wire including taking down old wiring complete all as specified and directed.
Supply & fixing in repairs single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 20 Amps complete all as specified and directed.
M & L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning complete all as directed by Engineer-in-Charge.
S&F in repairs aluminium fan blade suitable for condenser of window type AC of any capacity.
S&F in repairs PVC fan blower of cooling side of window type AC of any capacity.
S&F for motor for window type AC of 1.5/2 TR capacity, Complete all as directed by Engineer-in-Charge.
M & L for servicing of split type AC of capacity 1.5/2 TR of any by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, remore replacing worn out rubber, bushes/rubber packing, rectification of unusal noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning complete all as directed by Engineer-in-Charge. Note:- Spare parts will paid in relevant item here in after:-
Supply only of air filter of size 10 micron Split type AC 1.5/2 TR
Supply only Blade for condensing fan motor Split type AC
Supply only Capacitor 36,45,50 Mfd
Supply only condenser coil aluminium/copper of ac capacity 1.5 TR
Supply only condenser coil aluminium/copper of ac capacity 2 TR
Supply only suction valve brass type 5/8"of ac capacity 1.5 TR
Supply only suction valve brass type 5/8"of ac capacity 2 TR
Supply only coil sensor and room sensor for ac capacity of 1.5/2 TR
Supply only swing motor for air adjust of suitable size Make:OEM
Supply only relay for overload of suitable size for ac capacity 1.5/2 TR Make:OEM
S & F in repairs PCB Senser unit with wire remotre control of ductable AC indoor unit of Capacity 1.5 TR for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as specified and directed.
S & F in repairs PCB Senser unit with wire remotre control of ductable AC indoor unit of Capacity 2 TR for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as specified and directed.
S & F in repairs running capacitor, 36 Mfd suitable for AC of capacity 1.5 TR complete all as specified and directed.
S & F in repairs starting capacitor, 100-120 Mfd suitable for AC of capacity 1.5 TR complete all as specified and directed.
M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 1.5 TR,and S&F the same complete all as specified and directed.
M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 2 TR,and S&F the same complete all as directed by Engr-in-Charge.
S&F of blower motor of capacity 1/30 or 1/20 HP split type AC 1.5/2TR complete all as specified and directed.
M & L for removing the unserviciable compressor sealed unit of any make from water cooler 40/80 ltr after cutting copper tubing without any damage to existing part ,replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary , filter etc, jointing of copper copper refrigerent pipe line charging gas to required level , complete including cleaning of fins, leakage testing etc including testing for smooth functioning complete all as specified and directed.
M & L for removing the unserviceable compressor sealed unit of any make from window/split type AC of capacity 1.5 TR after cutting copper tubing without any damage to existing parts, replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filter etc. jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing etc including testing for smooth functioning complete all as specified and directed.
Al as per item No. 42.00 above but for window/split type AC 2 TR capacity.
S&F in repaired Compressor for Deepfreezer capacity 400 ltr with relay and thermostat complete after desmantalling and disconnecting of U/S compressor and topping up of refrigerant gas upto required level complete all as specified and directed.
S&F in repaired Compressor for Deepfreezer capacity 300 ltr with relay and thermostat complete after dismantling and disconnecting of U/S compressor and topping up of refrigerant gas upto required level complete all as specified and directed.
Supply & fix rubber gaskit of standard size for deep freezer with suitable screw and adhesives including removing u/s gaskits complete all as specified and directed.
S&F in repairs aluminium fan blade for water cooler
S&F in repairs thermostat suitable for water cooler of any capacity.
S&F in repairs waste water tray, stainless steel with coupling suitable for water cooler of capacity 40/80 ltrs complete all as specified and directed.
S & F PVC drain out flexible pipe of 20mm dia 70 cms length with two mild steel clamps and necessary brass screws etc for water cooler of any size complete all as specified and directed.
S & F in replacement push cock 15mm bore made out of brass chromium plated self closing vertical type complete all as specified and directed.
Supply & fixing in repair copper cooling coil for deep freezer of capacity 310 ltr with suitable fittings after dismantling and disconnecting of U/S cooling coil including testing.
Spply & fixing in repair of condensor motor of deep freezer of capacity 400 ltr with suitable fittings after dismantling and disconnecting of U/S cooling coil including testing.
Supply & fix in repair 3 pin tlug top of 5 amp including 3 mtr including PVC sheathed round flexible wire pvc 3 core 40/0.0076 of 3 mtr length for deep freezer.
M & L for repair for cutting and removing unserviceable freezer unit of refrigerator capacity 165/170/175 ltrs of any make, and supply and fix new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerator gas and testing for smooth functioning complete all as specified and directed.
S & F in repairs of bulb for pin/screw type 230 Volts suitable for refrigerator 175 to 310 ltrs capacity
Supply and topping up of Refrigerant gas R 134/404 in refrigerators/Deep freezers at different site as required including brazing and removal of leakage in equipment
Supply & fixing in repair copper cooling coil for refrigerator of capacity 190 ltr
Supply & fix in repair 3 pin tlug top of 5 amp including 3 mtr including PVC sheathed round flexible wire pvc 3 core 40/0.0076 of 3 mtr length for refrigerator.
M&L for cleaning after taking down complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamel spray paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No. etc. complete all as specified and directed.
S&F in repairs PVC flexible pipe 16mm outer dia complete with PVC elbow etc.
S&F in repairs wood wool pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as directed .
S&F in repairs switch piano type 250 Volts, single pole one ways 5 amps, fixed in desert coolers.
S&F repairs PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including necessary connection fixed in desert coolers.
S&F in repairs capacitor 4 Mfd for fan motors of desert coolers.
S& F in repairs Submersible pump 230 volts suitable for desert cooler of capacity 4000/5000 including necessary wiring complete all as directed.
S & F in repairs side shutter (set of three) made out from 24 guagethick galvanized iron sheet suitable for 4000/5000 cum/hrs capacity desert coolers complete all as specified and directed.
S&F in repairs float valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 142gm/each complete all as specified and directed.
S & F in repairs Aluminium fan blade for fan motor of desert cooler 20 inch sweep complete all as specified and directed.
S & F in repairs PVC, 3 way distributor suitable for 15 mm pipe with nut/screws complete all as specified and directed.
S & F desert cooler fan motor 3 speed copper winding ISI mark including suitable leg set of three including nut bolt washer complete all as specified and directed.
PRAGATI ELECTRICALS AND ELECTRONICS
Uma engineers
CREATIVE CONSTRUCTION
HRK ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .