Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.8 LAccepted-AOC | 1 | Accepted-AOC Accepted | |
| 2 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹3,800
Closing Date
9 Feb 2024, 3:00 pmClosed
Executive Officer
Pattanam Town Panchayat, Namakkal District
Renovation to the Community Toilet at Ward No, 6, K.V.K. Colony in Pattanam Town Panchayat, Namakkal District.
2024_DTP_417415_1
205/2023
Open Tender
Civil Works
Works
30 days
Pattanam Town Panchayat, Namakkal District
As per Tender Notice
2 documents required · 2 mandatory
₹0
₹3,800
7 Nov 2024
2 Feb 2024
9 Feb 2024
2 Feb 2024
9 Feb 2024
2 Feb 2024
2 Feb 2024 - 9 Feb 2024
Amount
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection, dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.
Paving the floor with plain/design Antiskirt ceramic tiles (colour shade as directed) of size 305mm x 305mm x 6mm in all floors over a base layer of cement mortor 1:3 (one cement and three sand) 20mm thick laid in-situ and pointed with same coloured cement
Supplying and laying and jointing of PVC pipes ( 6kg / Sqcm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting, fixing to PVC Specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - wood plugs, PVC clamps and screws, making holes on the wall or drilling holes in roof and making good the dismantled portion to original condition with necessary brick scaffolding charges . a). 25mm OD PVC pipe 10ksc
32 x 25mm OD PVC Reducer Tee
PVC Screw down tap heavy type 20mm dia.
b). 32mm OD PVC pipe 10ksc
32mm OD PVC Tee
32mm OD PVC End Cap
c). 90mm OD PVC pipe 4ksc
90mm OD PVC Vent Cowl
d). HDPE tank 1000-ltr Capasity
Wiring with 2x1.5 sqmm(22/0.3) PVCinsulated unsheathed Sc Cu.Conductor of 1100v grade in suitable PVC rigid Pipe on Wall and celling with PVC accessories with TW switch box with 5A F.T switch infulsh with wall, covered with hylem sheet of 3MM thick with painting of suitable colour for Open PVC light point point SD. 20.
Wiring with 2x1.5sq.mm (22/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with 150x100x113mm TW sitch box for 5A 3pin non interlocking Wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC plug point.S.D 36.
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
Painting the old iron works such as steel doors, Windows,Ventilators windows bars,balustrades etc, in all floor with One Coat of best approved first quality and colour of synthetic enamel paint of approved quality, colour and brand (to be approved by executive engineer before use on works ) over one the existing red oxide priming coat in all floors excluding cost of priming coat etc, complete complying with Standard Specification.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
White washing Two coats with good quality of Shell Lime including cost of all materials to site and all labour charges for mixing, applying and proper curring etc., Complete as per Standard Specifications.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .