Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC C O UTTAM BANIK HAIDERPARA OPPOSITE TO WEST BENGAL REPRESENTATIVE REST HOUSE P O HAIDERPARA SILIGURI 06 | JALPAIGURI | WEST BENGAL | 734006 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹54.0 L+₹2.9 L (5.74%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹54.0 L+₹3.0 L (5.80%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹55.1 L+₹4.0 L (7.82%)Rejected-Finance OODLABARI P O MANABARI DIST JALPAIGURI WB PIN 735222 STATE WEST BENGAL | JALPAIGURI | WEST BENGAL | 735222 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹55.5 L+₹4.5 L (8.77%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Jan 2024, 6:00 pmClosed
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
REPAIR AND MAINT OF LT PANELS, OH LINES, UG CABLES, HIGH MAST FLOOD LIGHT, POST TOP LANTERN, BOLLARAD LIGHTS, PIPELINE, CLEANING BOREWELL, TANKS AND CONNECTED ITEMS AT SHAUGAON, CHANDA COY AND MONGPONG AREA UNDER GE SEVOKE ROAD
2024_MES_635821_1
8292/SEV OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹90,000
Yes
23 Feb 2024
4 Jan 2024
2 Feb 2024
4 Jan 2024
25 Jan 2024
19 Jan 2024
5 Jan 2024 - 15 Jan 2024
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation, laying GI pipes and UG cables etc not exc 10 sqmtr on plan, in soft/loose soil and getting out complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation, laying GI pipes and UG cables etc not exc 10 sqmtr on plan, in hard/dense soil and getting out complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
Materials and labour for 50 mm outer dia double wall corrugated (DWC) HDPE pipe, ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
Materials and labour for 75 mm outer dia double wall corrugated (DWC) HDPE pipe, ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
Materials and labour for GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor all as specifed and directed.
Materials and labour for GI tubing of 50 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor all as specifed and directed.
Materials and labour for GI tubing of 80 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor all as specifed and directed.
Supply and laying in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 120sq mm x 3.5 core including taking down old u/s making necessery connections all as specified and as directed.
All as item No 10 but of size 95 sqmm 3.5 core
All as item No 10 but of size 70 sqmm 3.5 core
All as item No 10 but of size 50 sqmm 3.5 core
All as item No 10 but of size 25 sqmm 4 core
All as item no 10 but of size 16 sqmm 2 core
All as item no 10 but of size 16 sqmm 4.00 core
All as item no 10 but of size 10 sqmm 4 core
All as item no 10 but of size 10 sqmm 2 core
Supply and fixing Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws of type 410 SP-31 ( 9 metre long) including dismantling old unserviceable pole complete all as specified and directed.
Supply and fixing GI strip 32 x 6 mm as eath continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc including dismantling old unserviceable strip complete all as specified and directed by Engr-in-Charge.
Materials and labour for PCC, type C1, (1:3:6), using 20mm graded crushed stone aggregated, as in coping of poles including formwork including demolition of old damaged concrete from pole complete all as specified and as directed
Materials and labour PCC, type D2, (1:4:8), using 40mm graded crushed stone aggregated as in PCC/Road cutting /installation area and foundation of pole etc complete all as specified and as directed.
Materials and labour for boring holes 1mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
Supply and fixing in repair Indicator lamp (AC/DC), LED, type for as per existing fitting.complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 3 Phase LED Ammeter complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair, 3 phase LED Voltmeter complete all as specified and as directed by Engr-in-Charge.
Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core XLPE, armoured, aluminium conductor cable of size 70 to 120 Sqmm, Outdoor type, including taking out & relaying damaged UG cable after repair complete all as specified and as directed. (Note:- Excavation and connected items will be measured and paid separately)
Supply and fixing as in repairs MCCB four pole , 415 Volt, 63 Amps,16 KA , fixed thermal & magnetic setting complete all as specified and directed
Supply and fixing as in repairs MCCB four pole , 415 Volt, 100 Amps,16 KA , fixed thermal & magnetic setting complete all as specified and directed .
Supply and fixing as in repairs MCCB four pole , 415 Volt, 125 Amps,16 KA , fixed thermal & magnetic setting complete all as specified and directed.
Supply and fixing MCCB, 160 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release complete including taking down old unserviceable MCCB complete all as specified and as directed. .
Supply and fixing MCCB, 200 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release complete including taking down old unserviceable MCCB complete all as specified and as directed.
Supply and fixing MCCB, 250 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release complete including taking down old unserviceable MCCB complete all as specified and as directed.
Materials and labour for earthing complete with galvanized steel pipe electrode 40mm bore, medium grade, 3.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground level connected with earthing lead galvanized iron strip of size 25x5 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fix with cast iron funnel and wire-mesh, with protection pipe of 32 mm dia light grade galvanized steel tubing upto 7.5 meters length for drawing earthlead including common salt, charcol , bentonite in alternate layers etc all in around of earthing pipe of 600mm dia, complete all as shown in EP number 2 of SSR Part-1 including testing on completion and including taking down old U/S earthing & testing complete all as specified and as directed.
Materials and labour for painting old painted LT Panel/feeder pillar by two coats of synthetic enamel paint after preparation of surfaces complete all as specified and as directed.
Servicing of LT Panel after shut down and removing all dust particles and proper layout of LT panel wlth gland packing including 2.5 sqmm copper single core copper cable including repairing/replacing door hinges/door lock etc for necessary connections complete all as specified and directed
Materials and labour for Preparation of metalic surface with sand paper for street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge
Materials and labour for one coat of red oxide zinc chrome primer on steel surfaces of street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge
Materials and labour for aluminium paint two coats on newly primed metalic surface of street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge
Materials and labour for two coats of Yellow/black synthetic enamel paint on metalic surface complete all as specified and as directed by Engr- in-Charge
Materials and labour for preparation of old decorated concrete/plastered surfaces and applying two coats of Cement based paint complete all as specified and as directed by Engr- in-Charge
Supply and fixing in repair 5 KW ,three phase automatic Street Light timer switch for automatic switching on/off street light based on lux level of nature light, consisting of sensor overload protection fuse gear, power contactor & MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole/Wall mountable elcosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66 protection, with universal lock and key arrangement complete all as specified and as directed.
Materials and labour for taking up/lifting of submersible motor and pump assembly complete of any type/size upto 20 HP with unserviceable cable of any make and capacity from deep tube/bore well (of any depth) after providing lifting tools and tackles complete as required at site, carefully disconnecting of all electric connections, water connections in and including dismantling of column pipe lines shaft (of any size and length stage by stage) and keeping them aside under safe custody for reuse at site complete all as specified and directed by Engr-in-charge
Materials and labour for lowering of repaired submersible motor and pump assembly complete of any type/size upto 20HP capacity with submersible cable of any make and size complete in deep tube/bore well of any depth coupling with pump and motor, in and including connecting and lowering of old or new column pipe line shaft of any size and length (stage by stage) carefully with the help of necessary tools and tackles, reconnecting of all electric and water connections with new nuts bolts washers and rubber gasket and testing on load upto the entire satisfaction of Engr-in-charge complete all as specified and directed. Note: Column pipe if required will be measured and paid under relevant supply only item.
Materials and labour for transportation of defective submersible pump 10 HP to 15HP capacity three phase set to workshop dismantling the same incl disconnecting electrical connections decoupling 440 volt AC submersible motor pump set , dismantling the motor,taking out burnt winding wire from the stator, cleaning of the casing and the stator with wire brush, rewinding of motor with superior quality copper winding wire of existing size including varnishing an drying, cable jointing and repair replacement of worn at parts of pump reassembling the same with motor installing the motor and pump , reconnecting all pipe and electric connections and testing on full load complete. Note: Spare parts replaced shall be measured & paid seperately under respective supply only item of schedule. Cost of rewiring and winding materials is included in item rate.
All as per item No 47.00 above, but 1.5 HP to 3.0 HP capacity 3/1 phase.
Supply and fixing in repair flat submersible motor cable, three core, copper conductor of size 6.0 sqmm, including providing necessary connection and testing on completion complete all as specified and directed.
Supply only following spare parts suitable for submersilble pump set vertical type (10 HP to 15 HP ) complete all as specified and as directed :-
Stainless steel impeller as per existing
Thrust bearing as per existing
Thrust plate set as per existing
Sand guard as per existing
Stainless steel bush as per existing
Supply only following spare parts suitable for submersilble pump set vertical type (1.5 HP to 3 HP ) complete all as specified and as directed :-
Stainless steel impeller as per existing
Thrust bearing as per exsiting
Thrust plate set as per existing
Sand guard as per existing
Stainless steel bush as per existing
Development of tube well using conventional method by means of air compressor of suitable capacity at least 12 hours minimum, untill sand free/ mud free, clean water obtained from the existing deep tube well including water testing from Govt. lab or approved lab of Govt, complete all as specified and directed.
Supply only column pipe 100mm dia GI pipe heavy grade, 3 meter in length & both ends long threaded, including provision of heavy duty coupling / socket dia 100 mm and 150 mm long complete all as specified and directed
Supply only column pipe 80mm dia GI pipe heavy grade, 3 meter in length & both ends long threaded, including provision of heavy duty coupling / socket having dia 80 mm and 150 mm long complete all as specified and directed
Supply and fixing in repair Fully automatic three phase star delta starter in sheet metal enclosure type with overload, shortcut, single phasing, locked rotor, earth fault, current unbalance, phase sequence reversal, under current, over/under voltage protections for 15 HP capacity motor complete all as specified and directed by Engr-in-charge.
Materials and labour for complete servicing of chemical dosing system by cleaning all components, replacing any damaged item, drilling hole in pipe and fixing NRV injection valve and connecting it with high pressure discharge tube to dosting system avoiding any leaks with suitable arrangements and testing after completion all as directed by Engr-in-charge. (Note: all items required to be replaced will be paid seperately under supply only items)
Supply only injection valve (NRV) to protects againt backflow and generates optimal pressure all as directed
Supply only Suction and discharge tubes 3/8" high pressure for injecting chlorine all as directed.
Supply and fixing Single Phase Preventor used for automatic Star Delta Starter with on delay timmer (2-3min) and auto manual switch, complete all as specified and as directed.
Taking up or down from any position existing steel water tubing 20 mm bore of any type and connections carefully including cleaning for refixing or removal to E/M store yard or issued as credit complete all as specified and as directed. Note :Excavation/earth work shall be measured and paid separately under respective item of schedule considered here-in-before.
All same as item No. 70 above but 25 mm bore.
All same as item No. 70 above but 40 mm bore.
All same as item No. 70 above but 50 mm bore.
All same as item No. 70 above but 80 mm bore.
All same as item No. 70 above but 100 mm bore.
Relaying/refixing of old serviceable steel water tubing as obtained from item No. 70 to 75 here-in-before, jointing and testing in new or existing position including all new fittings, ISI Marked, such as bends, elbow, tee, reducers, sockets, unions, flange etc as required, laid in trenches or fixed to wall/cellinng or floors including making holes in wall where required complete all as specified and directed by Engr-in-charge for 20 mm bore pipes.
All same as item No. 76 above but 25 mm bore.
All same as item No. 76 above but 40 mm bore.
All same as item No. 76 above but 50 mm bore
All same as item No. 76 above but 80 mm bore
All same as item No. 76 above but 100 mm bore
Supply, laying, jointing & testing 20 mm bore galvanised iron tubing medium grade with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site laid in trenches complete all as specified and directed.
All same as item No. 82 above but 25 mm bore.
All same as item No. 82 above but 40 mm bore.
All same as item No. 82 above but 50 mm bore
All same as item No. 82 above but 80 mm bore
All same as item No. 82 above but 100 mm bore
Supply and fixing in repair gun metal gate/globe valve, 50 mm bore, ISI Marked, with iron wheel headed screwed both ends for pipe including taking down unserviceable complete all as specified and as directed.
All same as item No. 88 above but 40 mm bore.
All same as item No. 88 above but 25 mm bore.
All same as item No. 88 above but 20 mm bore.
Supply, laying, jointing & testing 3-layer PP-R (Polypropylene random copolymer) concealed pipes, 63 mm outer dia, SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings such as bends, elbow. tee, socket, reducers, unions fixed complete to walls, ceilings, trenches or in floors etc as required at site complete all as specified and directed.
All same as item No. 92 above but 50 mm outer dia.
All same as item No. 92 above but 32 mm outer dia.
All same as item No. 92 above but 25 mm outer dia.
Supply and fixing in repair PP-R Gate valves (brass insert), for 63 mm outer dia pipe, as per requirement of the site including taking down unserviceable valves complete all as specified and as directed of the following sizes:-
All same as item No. 96 above but for 50 mm outer dia pipe.
All same as item No. 96 above but for 32 mm outer dia pipe.
All same as item No. 96 above but for 25 mm outer dia pipe.
Materials and labour for seven stage cleaning and sterlisation of inside of overhead pressed mild steel/RCC tank of capacity 10000 gallons (overhead tank) through bacteriological treatment by using suitable chemical and Ultra voilet ray inc including arrangement of necessary T&P, labour and Chemicals mechanise etc before starting process of cleaning complete all as specified and as directed. Seven stages are as under follows :- (a) First stage is to drain out the water by using exit valve or by own high capacity dewatering system. (b) Second stage is cleaning all the algae formation inside the tank by using suitable chemical as approved by Engr-in-charge and scrubing the walls of the tanks. (c) Third stage is scrubbing the wall with mechanised scrubber and fresh water cleaning by high speed jet pump. (d) Fourth stage and first bacteria screening is degermification by using suitable chemical as approved by Engr-in-Charge . (e) Fifth stage is cleaning the floor of the water tank by industrial vacuum cleaner. (f) Sixth stage is the second bacteria screening and sterilizing method by using ultra voilet ray within the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterlize the floor of the water tank by using strong oxidizing agent as approved by Engr-in-charg. Make- Rays Clean Tech/ ML Treatment/ M/s Tank Cleaning Pvt Ltd.. Note- (i) Cost of safety equipment such as safety belt and Bambo platform/staging etc deemed to be included in the quoted rates.
Dismantling of GI Pipe Connections from the Pressure Filter Plant capacity 6000 to 10000 Gallons, opening the Manhole and removal/taking out old Filter Media completely from Oxidation Chamber, Pre-filter, Iron Removal Filter and depositing the same to a distance not exc. 100 Metre and re-fixing the pipes in the original/existing Position after replacement of unserviceable PVC Nozzle (Dom type) including replacement of Gasket of Manhole Cover and necessary Bolts, Nuts, Washers, etc. as required, complete all as specified and as directed.
Supply and incorporation of MNO2 of size 1/2'' x 1'' as filter media of iron removal plant complete all as specified and directed.
Supply and incorporation of GRAVEL of size 1 1/4'' x 1 1/2''(collection source BARAKAR river bank) as filter media of iron removal plant complete all as specified and directed.
Supply and incorporation of GRAVEL of size 1/2'' x 1''(collection source BARAKAR river bank) as filter media of iron removal plant complete all as specified and directed.
Supply and incorporation of GRAVEL of size 1/4'' x 1/2''(collection source BARAKAR river bank) as filter media of iron removal plant complete all as specified directed.
Supply & incorporation of SAND of size 1/6" x 1/8'' mesh (collection source BARAKAR river bank) as filter media of iron removal plant complete all as specified and directed.
Supply & incorporation of Anthracite grit of size 1/8" x 1/4'' as filter media of iron removal plant complete all as specified & directed.
Supply and fixing in repair PVC strainers of existing size complete all as specified and directed.
Materials and labour for painting to old painted external surfaces of Iron Removal Chamber, Pre-filter Chamber, Oxidation Chamber including Pipes complete of Fiteration Plant capacity 5000 GPH with Two Coats of Sythetic Enamel Paint of approved colour including neccessary preparation of surfaces, complete all as specified and as directed.
Materials and labour for painting to old painted Internal Surfaces of Iron Removal Chamber, Pre- filter Chamber and Oxidation Chamber including Pipes complete of Filteration Plant capacity 5000 GPH with Two Coats of Black Bituminous Paint (Lead Free) suitable for Drinking Water grade including necessary surface preparation by means of scraping, brushing, cleaning, complete all as specified and as directed.
Materials and labour for Painting to External Surfaces of old paited pressed steel tanks complete of any capacity/height with Two Coats of Sythetic Enamel Paint of approved colour including neccessary preparation of surfaces, complete all as specified and as directed.
Materials and labour for Painting to Internal Surfaces of Pressed steel tanks complete of any capacity/height with Two Coats of Black Bituminous Paint (Lead Free) suitable for Drinking Water grade including necessary surface preparation by means of scraping, brushing, cleaning, complete all as specified and as directed.
Supply and fixing sluice valve 150mm dia, PN 1.6 with Stainless steel spindle nuts, bolts, washers and rubber gasket sheet for packing including taking out existing unserviceable sluice valve fixed at any position all as specified and directed by Engr-in-Charge
Supply and fixing sluice valve 100mm dia, PN 1.6 with Stainless steel spindle nuts, bolts, washers and rubber gasket sheet for packing including taking out existing unserviceable sluice valve fixed at any position all as specified and directed by Engr-in-Charge
Supply and fixing sluice valve 80mm dia, PN 1.6 with Stainless steel spindle nuts, bolts, washers and rubber gasket sheet for packing including taking out existing unserviceable sluice valve fixed at any position all as specified and directed by Engr-in-Charge
Supply and fixing Butterfly valve 80mm dia, with nuts, bolts, washers and rubber gasket sheet for packing including taking out existing unserviceable sluice valve fixed at any position all as specified and directed by Engr-in-Charge
Supply and fixing Butterfly valve 100mm dia, with nuts, bolts, washers and rubber gasket sheet for packing including taking out existing unserviceable sluice valve fixed at any position all as specified and directed by Engr-in-Charge
Supply and fixing Butterfly valve 150mm dia, with nuts, bolts, washers and rubber gasket sheet for packing including taking out existing unserviceable sluice valve fixed at any position all as specified and directed by Engr-in-Charge
Materials and labour for construction of valve chamber with MS sheet cover 3mm thick with angle iron frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic enamel paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:4:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm thick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,painting on all steel surfaces as specified and as directed of sizes 1200mm x 1200mm x1200mm (internnal dimensions) including demolition of existing valve chamber,complete all as specified and as directed.
Materials and labour for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed.
Supply and fixing thermoplastic polycarbonate cable junction box having IP 66 protection, dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 16 sqmm and of size 155x210x92mm with terminals, brackets for street light pole mounting and provision of one 6A MCB SP all as specified and as directed.
Labour only for taking down any unserviseable street light fittings/flood light/garden light/gate light/fountain light fitting any type/size and refixing same after repair/replacement of all unserviceable accessories of any type and size from existing position/location or removing connection by cleaning terminals and shifting materials to store for keeping in safe custody for repair work or taking credit complete all as specified and as directed. (Note: Items required for repair work/replacement will be measured and paid seperately under relevant items as supply only)
Supply only post top lantern LED type, 20 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light, IP 65 protection with pressure die cast powder coated housing and PC diffuser luminaire, with impact and corrosion resistant complete with driver and lamp.
Supply only post top lantern LED type, 40 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light, IP 65 protection with pressure die cast powder coated housing and PC diffuser luminaire, with impact and corrosion resistant complete with driver and lamp.
Supply, fixing, testing and commissioning of LED flood light fitting 100 W new generation energy saving and enviromental friendly, long life, versatile pressure die cast aluminium IP 65 PDC floood light aesthetically designed with better thermal management with electronic driver complete all as directed by Engr-in-Charge
Supply only LED driver for 45/60/72 Watt LED street light complete all as specified and as directed.
Supply, fixing, testing and commissioning of LED flood light fitting 200 W new generation energy saving and enviromental friendly, long life, versatile pressure die cast aluminium IP 65 PDC floood light aesthetically designed with better thermal management with electronic driver complete all as directed by Engr-in-Charge
Supply Only Bollard light LED 9 watt 3000K complete all as specified and directed.
Materials and labour Street light bracket, made out of 32 mm dia GI pipe (light grade) 1.0 m long bend to shape as required and welded and fixing in position including dismantling and taking down old unserviceable bracket complete all as specified and directed.
M/S Bikash Saha
NARESH GUPTA
AJOY PAUL
KD SAHA and CO.INDIA
Biswas Brothers Co
M/S AJIT GARAGE
SHRI JIBANDHAN PAUL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .