| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.3 L+₹83,291 (2.65%)Rejected-AOC 227 2 5TH B MAIN ROAD 2ND BLOCK HRBR LAYOUT KALYAN NAGAR BANASAWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹34.0 L+₹2.6 L (8.20%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹37.0 L+₹5.6 L (17.8%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹38.0 L+₹6.6 L (20.8%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | RAHUL ENTERPRISES L4 | Vishwas Enterprises L1 | RRK PROJECTS L3 | M/s BHOOMI ELECTRICALS L2 | Varsha Enterprises L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket, fan regulators any type, rectangular board, light fittings, terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified & directed. | 620 | Per Point | 15 ₹9,300 | 10 ₹6,200 | 10 ₹6,200 | 20 ₹12,400 | 9 ₹5,580 Lowest |
| 2.00 | M&L for concealed Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified & directed.
(Note:- Cutting and making same the wall patches after laying the wire and conduit using putty, white wash and distemper. The surface shall be made smooth using putty and shall match exactly with the existing wall finish) | 120 | Per Point | 700 ₹84,000 | 600 ₹72,000 | 700 ₹84,000 | 699 ₹83,880 | 594 ₹71,280 Lowest |
| 3.00 | All as per Item No 2.00 here-in-before but for 3 pin 6 Amps socket outlet on independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified & directed. | 95 | Per Point | 700 ₹66,500 | 600 ₹57,000 | 700 ₹66,500 | 720 ₹68,400 | 594 ₹56,430 Lowest |
| 4.00 | All as per Item No 2.00 here-in-before but for 3 pin 6 Amps socket outlet on the same board complete all as specified & directed. | 20 | Per Point | 150 ₹3,000 | 100 ₹2,000 | 200 ₹4,000 | 200 ₹4,000 | 45 ₹900 Lowest |
| 5.00 | All as per Item No 2.00 here-in-before but for One light point controlled by two 2-way switches complete all as specified & directed. | 10 | Per Point | 700 ₹7,000 | 650 ₹6,500 | 700 ₹7,000 | 900 ₹9,000 | 603 ₹6,030 Lowest |
| 6.00 | All as per Item No 2.00 here-in-before but for 3 Pin 16 Amps socket outlet on independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire stranded and connected to earth dolly complete all as specified & directed. | 90 | Per Point | 800 ₹72,000 | 720 ₹64,800 Lowest | 800 ₹72,000 | 900 ₹81,000 | 720 ₹64,800 Lowest |
| 7.00 | S&F Modular switch 6 Amps single pole one way 230 V, 50 Hz, AC, with outer strip complete all as specified and directed | 235 | Each | 70 ₹16,450 | 70 ₹16,450 | 35 ₹8,225 | 160 ₹37,600 | 18 ₹4,230 Lowest |
| 8.00 | All as per Item No 7.00 here-in-before but 2 way complete all as specified & directed. | 20 | Each | 75 ₹1,500 | 85 ₹1,700 | 40 ₹800 | 180 ₹3,600 | 29.7 ₹594 Lowest |
| 9.00 | S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and directed | 90 | Each | 120 ₹10,800 | 170 ₹15,300 | 85 ₹7,650 Lowest | 210 ₹18,900 | 90 ₹8,100 |
| 10.00 | S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC, with outer/inner cover complete all as specified and directed | 115 | Each | 175 ₹20,125 | 125 ₹14,375 | 70 ₹8,050 | 140 ₹16,100 | 34 ₹3,910 Lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
11 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
REPAIR / MAINT OF CERTAIN E/M RELATED WORK SERVICES AT VARIOUS LOCATIONS IN CERTAIN MD / OTM ACCN AT CHAFB
2025_MES_740740_1
8428/E8
Open Tender
Civil Works
Item Rate
150 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹76,000
8 Jan 2026
20 Nov 2025
13 Dec 2025
20 Nov 2025
11 Dec 2025
4 Dec 2025
21 Nov 2025 - 28 Nov 2025
Amount
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket, fan regulators any type, rectangular board, light fittings, terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified & directed.
M&L for concealed Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified & directed. (Note:- Cutting and making same the wall patches after laying the wire and conduit using putty, white wash and distemper. The surface shall be made smooth using putty and shall match exactly with the existing wall finish)
All as per Item No 2.00 here-in-before but for 3 pin 6 Amps socket outlet on independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified & directed.
All as per Item No 2.00 here-in-before but for 3 pin 6 Amps socket outlet on the same board complete all as specified & directed.
All as per Item No 2.00 here-in-before but for One light point controlled by two 2-way switches complete all as specified & directed.
All as per Item No 2.00 here-in-before but for 3 Pin 16 Amps socket outlet on independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire stranded and connected to earth dolly complete all as specified & directed.
S&F Modular switch 6 Amps single pole one way 230 V, 50 Hz, AC, with outer strip complete all as specified and directed
All as per Item No 7.00 here-in-before but 2 way complete all as specified & directed.
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and directed
S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC, with outer/inner cover complete all as specified and directed
S&F for modular socket combined 2-in-1, 6 Pin, 6 & 16 Amps, 230 V, 50 Hz, AC, flush type with outer/inner cover complete all as specified and directed.
M&L for Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in Wiring with Copper conductor cables in PVC casing & caping/Conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with sunken boxes & PVC back plate for mounting all type switches, sockets & regulators etc with front plate including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and directed.
All as per Item No 12.00 here-in-before but for 3 pin 6 Amps socket outlet on independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and directed.
All as per Item No 12.00 here-in-before but for 3 pin 6 Amps socket outlet on the same board complete all as specified and directed.
All as per Item No 12.00 here-in-before but for One light point controlled by two 2-way switches complete all as specified and directed.
All as per Item No 12.00 here-in-before but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire stranded and connected to earth dolly complete all as specified and directed.
S&F modular switch 5 Amps, single pole, one way 230 V, AC complete all as specified and directed.
All as per Item No 17.00 here-in-before but 2 way complete all as specified and directed.
S&F modular switch 15 Amps, single pole, one way 230 V, AC complete all as specified and directed.
S&F modular Socket outlet 2 in 1, 3 pin, 5 A, 230 V, AC complete all as specified and directed.
S&F modular Socket outlet 2 in 1, 3 pin, 15 A, 230 V, AC complete all as specified and directed.
S&F modular Bell push flush type 5 amp 230 V, AC complete all as specified and directed.
S&F ceiling rose, surface bakelite 65x50mm, two to three terminals, fixed on PVC Round Block complete all as specified and directed.
S&F calling bell, ding dong, 230 volts, single pole complete all as specified and directed
S&F electronic step type fan regulator, 120 watt, 230 volts, 50Hz, two module C/S deluxe type complete all as specified and directed
M&L for sub main wiring with 10.00 Sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 10.00 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit not less than of 25mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing incl taking down old submain wiring complete all specified & directed. (Note : one run of earth continuity conductor, one run of PVC Conduit and two run of copper conductor together shall be taken as one length for measuring unit length)
All as per Item No 26.00 here-in-before but for 02 x 6.0 Sqmm for phase & neutral and 01 x 6.0 Sqmm for continuous earth wire in 20 mm PVC conduit complete all specified & directed.
All as per Item No 26.00 here-in-before but for 02 x 4.0 Sqmm for phase & neutral and 01 x 4.0 Sqmm for continuous earth wire in 20 mm PVC conduit complete all specified & directed.
All as per Item No 26.00 here-in-before but for 02 x 2.5 Sqmm for phase & neutral and 01 x 2.5 Sqmm for continuous earth wire in 20 mm PVC conduit complete all specified & directed.
All as per Item No 26.00 here-in-before but for 04 x 10.0 Sqmm for 3 phase & neutral and 01 x 10.0 Sqmm for continuous earth wire in 32 mm PVC conduit complete all specified & directed. (Note : One run of earth continuity conductor, one run of PVC Conduit and four runs of copper conductor together shall taken as one length for measuring unit length)
S&F in replacement sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 200 Amps rated copper bus bar and metal double door suitable for MCCB 63/100 amps as incomer and MCB SPs as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall complete all as specified & directed for the following ways :- (Note : MCCB & MCB SPs/SPN shall be measured and paid seperately)
S&F MCCB 63 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete all as specified & directed for the following ways :-
S&F in replacement Sheet metal enclosure DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs incl chases wall for fixing DB and making good to the disturbed surface complete for the following number of ways :-
S&F in replacement sheet metal enclosure, double door type for MCB TPN DB 4 way, vertical type, 415 volts with 200 Amps rated busbar and neutral link, chases wall for fixing DB and making good distributed wall surfaces to match with existing complete all as directed
S&F in replacement MCB TPN, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified & directed of following rating :-
S&F in replacement MCB SPN, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified & directed of following rating :-
S&F in replacement MCB SP, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified & directed of following rating :-
10 to 32 amps
S&F in replacement Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts, 20 Amps complete all as specified & directed.
S&F in repair switch piano, flush type, 5/6 Amp, single pole, one way, 230 volts complete all as specified and directed.
S&F Repair socket outlet 2 in 1, 3 pin, 5/6 Amp, flush type, 230 volts complete all as specified and directed.
S&F Repair switch piano flush type 15/16 Amp, single pole, one way, 230 volts complete all as specified and directed.
S&F Repair socket outlet 2 in 1, 3/6 pin 5 and 15 Amp, flush type, 230 volts complete all as specified and directed.
S&F Repair switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and directed.
S&F Repair switch socket combination 2 in 1, 3 pin, 5 amp flush type universal complete all as specified and directed.
S&F Repair Bell Push, flush type, 6 Amp, 230 Volts complete all as specified and directed.
S&F Repair modular switch 6/10 amps single pole one module, 230 volts complete all as specified and directed.
S&F Repair modular socket, 6/10 Amps, 5 pin, 2 module, 230 volt complete all as specified and directed.
S&F Repair modular switch 16/20 amps single pole one module, 230 volt complete all as specified and directed.
S&F Repair modular socket 16/20 amps, 2 module, 230 volt complete all as specified and directed.
S&F Repair modular bell push with indicator 6 amps, one module complete all as specified and directed.
S&F Repair modular fan step regulator 120 watt 2 module , 230 volt complete all as specified and directed.
S&F Repair Angular Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for light fittings complete all as specified and directed.
S&F in replacement electronic dimmers, 450 W, 250 V, flush type on the existing laminated sheet complete all as specified & directed.
S&F in replacement fresh air ventilating fan 230/250 mm sweep, 230V, AC, sturdy engineering plastic body with louver shutter etc complete and connection from ceiling rose to fan terminal complete all as directed
S&F in repair Plug top, 3 pin, 230 volt incl connection complete all as specified & directed. of following ratings :-
S&F in replacement LED lamp, BEE star rated energy efficient retrofit bulb, white/ warm white, complete all as specified & directed for following wattages :-
S&F in replacement LED lamp 0.5 watt, satelite white/ warm white, yellow/green/red, base cap B22 for engagement lights complete all as specified & directed.
Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 10 sqmm 2 core nominal cross section complete all as specified & directed.
S&F in repair PVC flexible twin twisted copper conductor cable multi strand of size 0.5 sqmm nominal cross section after taking out old unserviceable one including connection complete all as specified & directed.
S&F in repair PVC insulated and unsheathed flexible cable, 3 core, multi-stranded copper conductor, 1100 volt grade after taking out old unserviceable one including connection complete all as specified & directed.
2.5 sqmm 3 core
1.5 sqmm 3 core
S&F in replacement of exhaust fan, steel body, AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers along with all electrical wire connection incl taking down old fan & depositing to MES store complete all as specified and directed for the following sizes :- (Note: Old/unsv fan shall be deposited in MES store for declaring BER procedure)
300 mm sweep
380mm sweep
450mm sweep
S&F Ceiling fan complete with three blades,down rod, accessories 230 V, 1200 mm sweep, min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor incl connection including taking down old/unsv/faulty fan any sweep and depositing to MES store yard complete all as specified & directed. (Note: Old/unsv fan shall be deposited in MES store for declaring BER procedure)
S&F in repairs PVC Casing Capping of size upto width 25 mm & height 12 mm including all connected accessories complete all as specified & directed.
S&F in repairs PVC Conduit of Size 20/25 mm including all connected accessories complete all as specified & directed.
S&F in replacement of fan Capacitor 2.5/3.15 mfd, AC, 230 volt complete all as specified & directed.
S&F in replacement on surface/wall mounted LED batten, 20 watt, 230 V, AC, 4 feet, white / warm white, decorative box type with intigrated electronic drive & accessories including connection complete including taking down old/unsv light fitting complete all as specified & directed.
S&F in replacement on surface/wall mounted LED batten, 10 watt, 230 V, AC, 2 feet, white / warm white, decorative box type with integrated electronic drive & accessories including connection complete including taking down old/unsv light fitting complete all as specified & directed.
S&F in replacement LED building security light fitting 60 watt, 230 V, AC, outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp, clamps, suitable bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection, fitting to be fitted on existing / new bracket complete all as specified & directed. Note-New GI bracket shall be measured & paid seperately
S&F in replacement LED decorative down light fitting/recess mounted, round type, white/ warm white, high out put diffuser, 220 V, AC, with driver holder and LED lamp including connection complete all as specified & directed. for the following wattages :-
S&F in replacement LED wall mounting mirror type, white/ warm white pitcture/ wall light fitting with high out put diffuser 10 watt, 220 V, AC, decorative type with driver holder and LED lamp (As per sample) including connecting up with flexible copper conductor cable of suitable size complete all as specified & directed.
S&F in replacement air surface/ceiling recessed mounted LED panel type of size 2ft x 2ft, 36 W, 230 V, 5700 K complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete all as specified & directed.
S&F in replacement LED wall light fitting, decorative type, STYLO wall mounting, champagne gold / black finish fixture with plastic body as per sample suitable for 9/12 W LED lamp B22 base with driver holder with lamp white / warm white incl connection complete all as specified & directed.
S&F in repairs metal clad plug and socket for AC plug and geysers complete all as specified and directed.
S&F Security light mounting bracket made out of 40 mm bore light grade GI tube of suitable length, bend to shape and fixed to wall / pole by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed
S&F in repair Heating element for hot water geyser of 1.5 KW capacity, AC, 230 V, conforming to IS specifications, screw/flange type complete all as specified and directed
All as per Item No 75.00 here-in-before but of 2.0 KW capacity.
S&F in repair Thermostat suitable for water heater geyser upto 50 litres capacity complete all as specified and directed
S&F in repair PVC connection 15mm size with PTMT nuts of length 450 mm for hot water supply complete all as specified and directed
S&F in repair PVC connection 15mm size with PTMT nuts of length 600 mm for cold water supply complete all as specified and directed
S&F in replacement of LED lamp, inverter type bulbs, 12 watt, BEE star rated energy efficient Retrofit bulb back up time upto 04 hrs, auto cut off, 6500 K complete all as directed
S&F in replacement hermetically sealed new compressor for split AC of following capacity of existing make including disconnecting the electrical and refrigerant connection of defective sealed unit of split AC and re-connection of all pipe line & charging of refrigerant and testing complete all as directed of following capacity of split type AC :- (Note :- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase)
1.5 TR capacity
2.0 TR capacity
S&F in replacement of capacitor suitable for split type Air Conditioner of existing make and for capacity of 1.0 / 1.5 / 2.0 TR complete all as specified and as directed for the following rating :-
S&F in replacement Blower motor, suitable for split type air conditioner of capacity 1.5 TR complete all as specified and as directed.
S&F in replacement Condenser Fan motor of existing make suitable for split type air conditioner of capacity 1.5 TR complete all as specified and as directed
M&L for servicing of Split type ACs of capacity 1.0/1.5/2.0/3.0 Ton of any make as and when ordered including cleaning of air filters, greasing of fan/blower motors, electrical connections etc. as in preventive maintenance complete all as specified and as directed (Note : Replacement of spares, charging of gas etc. shall be measured and paid separately)
S&F Refrigerant gas (R 22) suitable for cooling equipments supplied and filled complete all as specified and as directed
S&F in replacement of Copper tube, 15 mm/18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof complete all as specified and as directed.
S&F in replacement Copper tube, 9 mm dia, superior quality suitable for refrigeration and discharge lines of split ACs, drawn trough pipes/ fixed to walls/ laid on floor or roof complete all as specified and as directed.
S&F in replacement invertor AC Printed Circuit Board (PCB), suitable for split type inverter Air Conditioner of existing make of 1.5 TR capacity complete all as specified and as directed.
S&F Refrigerant gas (R 410) suitable for cooling equipments supplied and filled complete all as specified and as directed
M&L for pressure testing and rectifying the leakages found in the system of split type ACs of capacity 1/1.5/2/3 Ton and including vacumizing,charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and as directed. (Note : Topping up of gas shall be measured and paid seperately)
S&F Condenser coil in replacement after disconnecting the refrigerant connection of defective condenser coil unit of split AC of capacity 1.5/2 Ton and replacing the condenser coil unit connecting the same unit with refrigerant connections complete all as specified and as directed.
M&L for shifting of Air Conditioner, split type of capacity 1.0/1.5/2.0/3.0 TR from existing location to new location as per user requirement and installing, topping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. (Note :- Topping up of gas and copper tubing shall be measured and paid seperately)
S&F LED post top light, 40 watt, 230 volts, AC, outdoor type with decorative post top for 360 degree indirect light IP 65 protection, made from aluminium housing with impact and corrosion resistant with driver and lamp, fitting to be fittied & incl GI pipe of required length & size, fixed at gate/wall incl connection complete all as specified & directed.
M/s BHOOMI ELECTRICALS (BID ID -3501682)
RRK PROJECTS (BID ID -3495489)
RAHUL ENTERPRISES (BID ID -3494565)
Varsha Enterprises (BID ID -3501745)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
SOC_8428.pdf
Additional Documents • 0.03 MB
Tender_8428.pdf
Tender Documents • 0.59 MB
BOQ_829450.xls
BOQ • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .