Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹36.2 L+₹3.0 L (9.05%)Rejected-Finance | L2 | Rejected-Finance Rejected being lowest bidder | |
| 3 | L3₹36.6 L+₹3.4 L (10.2%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance Rejected being lowest bidder | |
| 4 | L4₹36.6 L+₹3.4 L (10.4%)Rejected-Finance | L4 | Rejected-Finance Rejected being lowest bidder |
Tender Value
₹40.7 L
EMD Value
₹81,500
Closing Date
19 Nov 2020, 6:00 pmClosed
CWE KIKREE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
SPECIAL REPAIRS TO BLDG NO P-3 ME LINE OF CAFVD UNDER GE (C) KIRKEE
2020_MES_389381_1
CA No CWE/ KKE/ TOKEN-15 OF 2020- 21
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹81,500
Yes
27 Jan 2021
23 Oct 2020
21 Nov 2020
24 Oct 2020
19 Nov 2020
6 Nov 2020
25 Oct 2020 - 30 Oct 2020
Amount
Taking down chowkats and frame n.exc 1.5 Sqm each including shutters without taking off shutters from the frame and removing from site complete all as specified and directed.
Taking down shutter of any description exceeding 1 sqm each and but not exceeding 2sqm each and removing from site complete all as specified and directed.
Supply and fix 35mm thick Plain, framed, panelled shutters (Two number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers veneers: supplied and fitted to chowkats. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L for 35 mm thick 2nd class hard wood glazed/gaused and skelton door shutter, factory made, open rebated and prepared to receive glass/guage etc. (without sash bar) edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing glass/guage etc. size of member as specified in SSR Part I Section 8 clause 8.24(a) and fixed to chowkat complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
M&L for Preparing surfaces of wood and wood based materials new or old of any description and girth, not other wise described and treated with two coat of creosote oil complete all as specified and directed.
S&F for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F Galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
S & F 200mm long Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm size Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F Aluminium handles, cast type, anodised of size 150mm, fixed with screws or welded complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Taking down GI tubing 15mm dia and connection including removable to store or credit to the contractor complete all as specified and directed.
Taking down GI tubing 20mm dia and connection including removable to store or credit to the contractor complete all as specified and directed.
S&F 15mm bore GI tubing ISI marked of size 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /wall/ceiling and including clips, wall hooks etc, including testing complete all as specified and directed
S&F 20mm bore GI tubing ISI marked of size 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /wall/ceiling and including clips, wall hooks etc, including testing complete all as specified and directed
Refixing only 15mm tubes any grade, to walls and ceilings or laying in floors including supply and fixing of new fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc. complete all as specified and directed. (Note: Old GI pipes in good condition as retrived from respective item hereinbefore shall be used.)
Refixing only 20mm tubes any grade, to walls and ceilings or laying in floors including supply and fixing of new fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc. complete all as specified and directed. (Note: Old GI pipes in good condition as retrived from respective item hereinbefore shall be used.)
S & F in repairs PVC flexible connections 15 mm dia, 600 mm long with brass check nuts complete all as specified and as directed.
S&F in repairs 15mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repairs 15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or utterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repair 20mm bore dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repair 25mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m m - 2 1 0 g m s ) complete all as specified and directed.
Supply and fix 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) double layered 'ISI' marked, hoisted & fixed in position with existing inlet, outlets & provision of washouts, vent pipe, nipples of suitable size hoisted and fixed in position all as specified in SSR part-I (2009) including dismantling and removal of existing water tank from site complete all as specified and as directed.
S & F in repairs Vitreous China Squatting pan Orissa pattern long pan, size 580 mmX440mm white with `P' or `S' trap, front or back inlet and foot rests any pattern including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including concrete bedding complete including making good to floor complete all as specified and as directed.
S&F in repair PVC low level flushing cistern 10 ltrs capacity with float ball valve and bracket including fixing of flush pipe & 15mm dia PVC connector pipe 450mm long with two nos brass fly nuts complete all as specified and as directed.
S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
S&F in repair 110mm bore dia PVC (SWR) junction single, (Single T) equal or unequal with access door, complete.
S&F in repair 110mm bore dia PVC (SWR) branch piece, double (double Y) equal or unequal with access door complete all as specified and as directed.
S&F in repairs PVC (SWR) bend with access door of any radius 110mm bore complete all as specified and as directed.
S&F in repairs PVC (SWR) bend with access door of any radius 75mm bore complete all as specified and as directed.
S&F in repair PVC (SWR) floor trap, Diameter of outlet in 75 mm plain with grating including jointing with solvent cement complete all as specified and directed.
S & F in repairs brass CP shower rose 125mm size with swivel joint including fixing to steel pipe 15mm complete all as specified and as directed.
S & F in repairs vitreous china wash basin white flat back size 550 x 400 mm excluding taps waste chain and plug and porcelain stopper but including necessary brackets CP wastes and other fittings complete all as specified and as directed.
S&F in repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
S&F E-board 'Everest' make 605x605x4mm thick white prelaminated sett embossed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm center to centre securely fixed to the structural soffits by approvedhangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete . The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm center to form 1200x600mm modules cross tee longer than 600mm to be supported independently. 600mmx600mm modules to be formed by fitting 600mm long cross Tee centrally between the 1200mm cross tee. Tee, Perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour all as per manufacture instruction including taking down wall / ceiling board of any thickness including fillets complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris outside MD land complete all as specified and as directed.
M & L rendering 20 mm thick in two layer on stone masonry surfaces in CM 1:4, finished even and smooth without using extra cement complete all as specified and as directed.
Dismantling Single or double layer Mangalore pattern or similar tiles or ridge in roofing complete all as specified and as directed.
S&F roof tiles , Mangalore Pattern, inter locking at side joints laid dry complete all as specified and as directed.
S&F ridge or hip tiles to suit Mangalore Pattern of roofing tiles bedded and jointed in CM 1:6 complete all as specified and as directed.
S & F second class hard wood clean sawn battens at 30 cm centre to centre and sectional area exceeding 15 and not exceeding 25 Sqcm including dismantling Battens for tiles ,singles etc. of any size including tiling fillets spaced exceeding 15 cm complete all as specified and as directed.
S & F second class hard wood clean sawn in scantlings including dismantling timber in scantling 40 sq.cm and over in section in any position and any description unframed work complete all as specified and as directed.
S & F 2nd class H/W plain fillets, rails, rafters, purlins, square, rectangular in section clean sawn secured with nails brads exceeding 13 sqcm but not exceeding 25 sqcm including dismantling timber scantlings in fillets, rails, posts, rafters, purlins etc under 40 sq. cm in section (Unframed work) in any position complete all as specified and as directed.
S & F for 0.63 Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 120gms/Sqm including dismantling of plain or corrugated steel sheeting any gauge thickness including Nainital or similar pattern as in roof covering complete all as specified and directed.
S & F for plain, galvanised mild steel sheeting in ridges hips valley gutters drip and straight flashing (length and girth as fixed) by using 1.00mm thick sheet grade of zinc coating @120 Gms/Sqm both sides and welded or soldered joints are provided including dismantling of plain or corrugated steel sheeting any gauge thickness including Nainital or similar pattern as in roof covering/valley gutters complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, and precast concrete block walling complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L for rendering 15mm thick plaster in cm (1:4) on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement including using water proofing compound all as specified and directed. Note: (i) Plaster work in Four story building on wall surface. (ii) Water proofing compound paid and measured separately)
Supply only Liquid water proofing compound complete all as specified and directed.
Demolition of Concrete reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and removing the including removing debries outside the MD and depositing where directed complete all as specified and as directed.
M&L for RCC types A1, 1:1.5:3 (20mm graded aggregate) as in beam, cantilivers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for RCC types A1, 1:1.5:3 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 5mm and over upto and including 10mm dia in stirrups spaces and binders complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M & L for washing, rubbing down and stopping of old distempered and painted surfaces of wall and applying a thin coat of wall care putty, two coat oil bound distemper over one coat of water based interior wall primer complete all as specified and directed.
M&L for preparing new plastered surfaces of wall and applying a thin coat of wall care putty, two coat oil bound distemper over one coat of water based interior wall primer complete all as specified and directed.
M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for Preparation of old surfaces (Plastered or un-plastered) of walls and applying two coats of cement base paint complete all as specified and directed.
M & L for preparing new or previously untreated wood surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified
M & L for preparing old wood surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old steel or iron surfaces (by complete removal of existing treatment) of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for 25 mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in floor, pavings or levelling course for floor tiles, etc, finishing the surface fair and even without using extra cement complete all as specified and directed.
M & L coloured ceramic tiles 400 mm x 400 mm x 7-8mm thick,in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in CM 1:6 including demolition of existing flooring of any type and description and removing the debris outside MOD land complete all as specified and directed.
M&L for glazed ceramic tiles coloured in vertical surface (300 x 200 x 7mm thick) on walls, set & jointed in neat cement slurry & pointed colour cement to match over and including rendering 10mm thick plaster in cm (1:4) on fair faces of brick work or concrete surfaces including finishing the surface fair and even and dismantling of existing wall tiles of any type and description and removing the debris outside MOD land all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving below or above GL not not otherwise provided for complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection including finishing the surface even & smooth without using extra cement complete all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealed box for mounting of switchs, regulators or bell push and casing capping terminal box for mounting ceiling rose/ holders etc including dismantling and taking down old unserviceable point wiring and fittings and fixtures and making good to disturbed surfaces complete all as specified and as directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on independent board including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealed box for mounting of switchs, sockets including dismantling and taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and as directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches including dismantling and taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and as directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switchs including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealed box for mounting of switch etc. including dismantling and taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point on independent board including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealed box for mounting of switches, sockets including dismantling and taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and as directed.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly including dismantling and taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and as directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping will be measured as one length.
S&F 5 Amp switch piano type single pole one way including dismantling and taking down unserviceable switches complete all as specified and as directed.
S&F 5 Amp switch piano type single pole two way complete all as specified and as directed.
S&F socket flush type 6 amps, 5 pin, 230v including dismantling and taking down unserviceable sockets complete all as specified and as directed.
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v including dismantling and taking down unserviceable switch socket complete all as specified and as directed.
S&F lamp Holder insulated body with back plate for batten fitting complete all as specified and as directed.
S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) complete all as specified and as directed. Make-HPL/Havells/CG/Bajaj/ Philips as approved by GE
S&F ceiling rose surface type bakelite three terminal including dismantling and taking down unserviceable ceiling rose complete all as specified and as directed.
S&F flush type electronic fan regulator with 5 step type,100 Watt, AC 240 Volts, 50 Hz including dismantling and taking down unserviceable fan regulator complete all as specified and as directed.
S&F MCB distribution board, as MCB incomer, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way ETPN complete all as specified and as directed. Make cat part no. 5076-11 of Legrand or equivalent of schneider or ABB as approved by GE
S&F MCB distribution board, as MCCB incomer, IP 30 protection, Double door, metal enclosure,ETPN, 415 Volts, 4 way complete all as specified and as directed. Make cat No. 5076-60 of Legrand or equivalent of schneider or ABB as approved by GE
S&F MCB,TPN, 63 Amps, 415 Volts,10 KA complete all as specified and as directed. MAKE- Cat Part No- 4086-83 of Legrand or equivalent of Schneider/ABB as approved by GE
S&F MCB, Single Pole 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve complete all as specified and as directed. Make-Cat Part No.4085-87 to 4085-95 of Legrand or equivalent of schneider/ABB
S&F MCB, Single Pole and neutral 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve complete all as specified and as directed. Make-cat part no.4086-9 to 4086-17 of Legrand or equivalent of schneider/ABB as approved by GE
S&F ceiling fan of 1200 mm sweep complete including suitable fan regulator, fan rod, clamp, nut, bolt & washers complete all as specified and as directed. Make: Bajaj / Havells / Usha /Cropton Greaves
S&F Exhaust fan Metal body light duty 300 mm sweep complete with grill complete all as specified and as directed. Make- Havells, cat Part No-Vent air-DS or Equivalent in Bajaj / Havells / Usha / Cropton Greaves
S&F LED Tube light fitting, 18 watt, CDL, 230 Volts, 4 feet long , complete with all accessories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable including LED tube and mounting casing box 2 Nos including dismantling and taking down unserviceable fitting any type complete all as specified and as directed. Make-CG, Cat Part No LCTL-18-CDL (Trim Linea) or equivalent in Bajaj/Philips/HPL/Havells
S&F LED tube light fitting with LED tube, 2' long, 09 watt, CDL, 230 Volts , complete with all accessories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 Nos including dismantling and taking down unserviceable fitting any type complete all as specified and as directed. Make-CG, Cat Part No-LCTL-9-CDL (Trim Linea) or equivalent in Bajaj /Philips /HPL /Havells
S&F LED security light fitting, 25 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener including dismantling and taking down unserviceable fitting any type complete all as specified and as directed. Make-CG, Cat Part No LSTS-25-CDL or equivalent in Bajaj/ Philips/ HPL/ Havells
Supply and installation of solar water heating system flat plate collector type with heat exchanger of 200 litre per day capacity with electrical heating back up including removing unservicable geysers of any capacity and depositing to E/M store yard.
S & F rotational moulded polythelene water storage tanks of capacity 500 ltrs ( cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I (2009) including dismantling of existing water tank complete all as specified and directed.
S&F 25mm bore GI tubing ISI marked of size 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /wall/ceiling and including clips, wall hooks etc, including testing complete all as specified and directed
Lagging to pipes of internal dia 25/20 mm all arround with,25/20 mm thick bonded mineral wool preformed 'SNAPON' pipe sections of density 144 Kg/cum confirming to IS 9842 complete all as specified and directed
S&F 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs 20mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
M&L framed brackets of angle or Tees with web and flanges cut into shape,drilled and counter sunk for screws,including bending and welding angles,as necessary gusset plates,rivetting confirming to Fe.290 Gde-E-165 complete all as specified and as directed.
M&L for PCC, type C-2, 1:3:6 mix using 40 mm graded stone aggregate as in foundations,filling and mass concrete complete all as specified and as directed.
M & L for Earthing complete with galvanized steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanized steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wire mesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal complete all as specified and as directed in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion complete all as specified and as directed.
Supply and lay LT UG cable 3.5 core 35 sqmm XLPE insulated sheathed armoured 1100 volts grade laid in trenches complete including indoor/ out door joint complete all as specified and as directed.
Excavation in trenches for laying of cable, for pole & stay not exceeding 1.5 mtr wide & not exceeding 1.5 mtr in depth & getting out in any type of soil complete all as specified and as directed.
Returning & refilling in including spreading levelling watering & well ramming in layers n.exc. 25 cm thick in soil complete all as specified and as directed.
Removal of excavated material not exceeding 50 m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Material and labour for crushed stone dustas in cushioning to underground cables in trenches including spreading, levelling, hand punning and consolidating complete all as specified and directed.
S&F 40mm bore GI tubing ISI marked of size 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /wall/ceiling and including clips, wall hooks etc. including testing and taking down existing GI tubing complete all as specified and directed.
M & L for reinforced precast concrete cable cover class LV type -1 flat of size 250mm x 150mm x 40 mm for cable protectioncomplete all as specified and directed.
L.K.R.TIWARI CONSTRUCTION
S.R.M.K Enterprises
Shri Sant Cosntruction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .