Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 CrAdmitted-Finance | ₹7.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹7.8 Cr+₹61.5 L (8.58%)Admitted-Finance | ₹7.8 Cr+₹61.5 L (8.58%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical DHANBAD | DHANBAD | JHARKHAND | 818142 | - | - | Rejected-Technical REJECT |
| 4 | Rejected-Technical | - | - | Rejected-Technical REJECT |
| 5 | Rejected-Technical | - | - | Rejected-Technical REJECT |
| Sl No | Description | Qty | Unit | M/S SANJEEV KUMAR L2 | MAA KRIPA DEVELOPERS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00ESR capacity with staging 18 M- 436 KL | |||||
| 2.00Doing Geotechnical survey, Collecting field data, designing aesthetically, getting it approved by competent authority and Providing all labours and equipment for designing & construction of ESR all complete job. | |||||
| 3.00Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging Consisting of columns, internal and External bracings spaced vertically not More than 4.5 metres centre to centre for ESR having capacity upto 500 cum and Not more than 6m c/c for ESR shaving Capacity above 500 Cum including Excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and outside face of the container and also plaster with plastic paint in all columns and bracings including refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, outside, Stainless steel ladder in contenor, C.I. manhole frame and covers, water level indicators,l ightening conductor, G.I. pipe railing around walk way and top slab, Providing Stair case from ground level to roof level , MS Grill Gate of 2M Height with locking arrangement of approved design,B.B. Masonary Chambers For all valves ventilations shafts, providing and applying three coats acrylie emulsion with silicon edditives paint to the structure including roof slab, epoxy painting to internal surface and anti-termite treatment for underground part soft the structure and giving satisfactory water tightness test as per IS code. the job to include painting then ame of the scheme and other details on the reservoir as per the directions of engineer in chief. | |||||
| 4.00Providing spiral stair case from ground level to roof level, M.S. Grill gate of 2M height with locking arrangement of approved design, B.B. Masonry chambers for all valves, providing and applying three coats of Cement paint to the structure including roof slab, epoxy painting to internal surface and anti-termite treatment forunder ground part soft he structure and giving satisfactory water tightness test as per I.S. code. The job to include painting then ameof the scheme and other details on there servoir as per the directions of Engineer In - Charge. | |||||
| 5.00Notes | |||||
| 6.00The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 2009 or revised.) | |||||
| 7.00The design shall satisfy the stipulations as per I.S. 1893 -1984 and I.S.13920/1993 for seismic force and I.S.-11682 / 1985 for R.C.C. staging of over head tanks. | |||||
| 8.00For design having more than 6 columns, provision of internal bracing is obligatory. External bracings is also obligatory. | |||||
| 9.00The Entire structure shal be M/250 mix only .However concrete in contract with water such as container base slab,walls,roofs slab & putting in water base area shall be in M300 | |||||
| 10.00Plain round mild steel bars grade- I conforming to I.S.432 part-I orhigh yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall beused, grade- I Imild steel bars will not be allowed | |||||
Tender Value
₹7.4 Cr
EMD Value
₹7.5 L
Closing Date
22 May 2026, 5:00 pmClosed
Executive Engineer D.W. and S. Div. Jhumritelaiya
At Pani Tanki Campus Lakhibagi Koderma
Construction of Intake Well PH, Gangway WTP ESR Staff Quarter, Raw and Clear Water rising main and Distribution Network and Five years OM with allied works etc. all complete job for Sainik School Telaiya WSS under D.W. and S. Div. JMT (2nd Call)
2026_DWSD_113677_1
04/JMT/2026-27
Open Tender
Civil Works
Item Rate
545 days
D. W. and S. Division Jhumritelaiya
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹7.5 L
EIC DWSD JHARKHAND RANCHI
24 Jul 2026
6 May 2026
23 May 2026
6 May 2026
22 May 2026
7 May 2026
11 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | ESR capacity with staging 18 M- 436 KL | - | - | - | - |
| 2 | Doing Geotechnical survey, Collecting field data, designing aesthetically, getting it approved by competent authority and Providing all labours and equipment for designing & construction of ESR all complete job. | - | - | - | - |
| 3 | Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging Consisting of columns, internal and External bracings spaced vertically not More than 4.5 metres centre to centre for ESR having capacity upto 500 cum and Not more than 6m c/c for ESR shaving Capacity above 500 Cum including Excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and outside face of the container and also plaster with plastic paint in all columns and bracings including refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, outside, Stainless steel ladder in contenor, C.I. manhole frame and covers, water level indicators,l ightening conductor, G.I. pipe railing around walk way and top slab, Providing Stair case from ground level to roof level , MS Grill Gate of 2M Height with locking arrangement of approved design,B.B. Masonary Chambers For all valves ventilations shafts, providing and applying three coats acrylie emulsion with silicon edditives paint to the structure including roof slab, epoxy painting to internal surface and anti-termite treatment for underground part soft the structure and giving satisfactory water tightness test as per IS code. the job to include painting then ame of the scheme and other details on the reservoir as per the directions of engineer in chief. | - | - | - | - |
| 4 | Providing spiral stair case from ground level to roof level, M.S. Grill gate of 2M height with locking arrangement of approved design, B.B. Masonry chambers for all valves, providing and applying three coats of Cement paint to the structure including roof slab, epoxy painting to internal surface and anti-termite treatment forunder ground part soft he structure and giving satisfactory water tightness test as per I.S. code. The job to include painting then ameof the scheme and other details on there servoir as per the directions of Engineer In - Charge. | - | - | - | - |
| 6 | The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 2009 or revised.) | - | - | - | - |
| 7 | The design shall satisfy the stipulations as per I.S. 1893 -1984 and I.S.13920/1993 for seismic force and I.S.-11682 / 1985 for R.C.C. staging of over head tanks. | - | - | - | - |
| 8 | For design having more than 6 columns, provision of internal bracing is obligatory. External bracings is also obligatory. | - | - | - | - |
| 9 | The Entire structure shal be M/250 mix only .However concrete in contract with water such as container base slab,walls,roofs slab & putting in water base area shall be in M300 | - | - | - | - |
| 10 | Plain round mild steel bars grade- I conforming to I.S.432 part-I orhigh yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall beused, grade- I Imild steel bars will not be allowed | - | - | - | - |
| 11 | Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
Technical.pdf
Tender Documents • 4.18 MB
BOQ_153608.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .