Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L1 | Accepted-AOC valid | |
| 2 | L2₹40.9 L+₹48,730.50 (1.20%)Rejected-Finance H NO 670 SECTOR 10 PANCHKULA HRY 134115 | PANCHKULA | HARYANA | 134115 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹42.8 L+₹2.4 L (5.90%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹44.3 L+₹3.9 L (9.57%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹45.1 L+₹4.6 L (11.5%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
19 Jan 2022, 6:00 pmClosed
GE (AF) SURATGARH
GE (AF) SURATGARH
PROVN OF TWO CLASS ROOMS WITH BOYS AND GIRLS TOILETS AT AF STATION SURATGARH
2021_MES_496746_1
8923/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹85,200
Yes
1 Apr 2022
22 Dec 2021
21 Jan 2022
22 Dec 2021
19 Jan 2022
5 Jan 2022
Amount
BOQ (PROVN OF TWO CLASS ROOMS WITH BOYS AND GIRLS TOILETS AT AF STATION SURATGARH.)
Surface excavation not exc 30cm deep and averaging 15 cm deep & getting out in soft loose soil, complete all as specified and directed by Engr-in-Charge.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-Charge.
Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating over areas, exc 1.5 m but n exc 3.0 m deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
M&L along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc, in apron complete all as specified and as directed.
M&L for plain cement concrete 1:4:8, type D-2 using (40mm graded crushed stone aggregate) as in foundation filling, mass concrete complete all as specified and as directed.
Returning filling in, including, spreading, levelling and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6.0m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan in half brick thick wall, built in cement mortar 1:4 complete all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter surface fair finished complete all as specified and as directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions surface fair finished complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, shelves, landing and similar work not exceeding 200mm thick (horizontal or sloping) and to edges of concrete surface fair finished complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.surface fair finished complete all as specified and as directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide surface fair finished complete all as specified and as directed.
M&L for mild steel high yield strength TMT bars 10mm dia and over cut to length bent to shape required, including cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for mild steel high yield strength TMT bars 6mm dia and over upto 8mm dia cut to length bent to shape required, including cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for mild steel high yield strength TMT bars 5mm dia and over upto 10mm dia as in stirrups spacers and binders cut to length bent to shape required, including cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for reinforced cement concrete M-25 design mix (20mm graded graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete M-25 design mix (20mm graded graded stone aggregate) in column, piers, posts and struts complete all as specified and as directed.
M&L for reinforced cement concrete M-25 design mix (20mm graded graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for reinforced cement concrete M-25 design mix (20mm graded graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and as directed.
M&L for 5mm thick rendering in cement mortar 1:3 on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and as directed.
Spreading of soil, levelling, watering and well ramming in layers n exc. 25cm thick under floors complete all specified and as directed. (Earth obtained from item No 3 shall be used)
M&L for hard core of broken stone or boulders broken to gauge exceeding 63mm but not exceeding 100 mm deposited, spread and levelled in layers not exc.15 cms thick, each layer watered and well rammed to a true surfaces complete all as specified and as directed.
M&L for 100mm thick plain cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in sub-base for floors, surface finished even and rough to receive top finish complete all as specified and as directed.
M&L for 25mm thick cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in levelling course, surface finished fair and even without using extra cement complete all as specified and directed.
M&L for 10 mm thick (square/ rectangular) vitrified ceramic, coloured, joint free tiles polished, area of each tile not exceeding 0.36 Sqm; as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match with colour of the tiles over and including screed bed of 15mm thick in cement mortar (1:6) complete all as specified and as directed.
M&L for 10 mm thick (square/ rectangular) vitrified ceramic, coloured, joint free skirting polished, area of each tile not exceeding 0.36 Sqm; as in skiriting dado etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match with colour of the tiles over and including backing coat of 10mm thick in cement mortar (1:4) complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles joint free 7 to 8mm thick square / rectangular area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tile, laid over and including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for Glazed ceramic coloured tiles, size 450mm x 350mm x 7mm thick as on vertical surfaces such as dado/skirting etc laid over and including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointing in white cement with pigment to match complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6, type C2, using 40mm graded crushed stone aggregate as in plinth protection, laid in slope of 1:20 and surface finished even and smooth without using extra cement including making joint at 3m interval and at each corner the joint shall be filled with bitumen mastic filling to full depth (comprising one part hot blown bitumen 85/25 and two part of sand), complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper white or tinted over a coat of primer and including a coat of birla 1-1.5mm thick white putty complete all as specified and as directed.
M&F for preparation of new plastered surfaces of ceiling and applying three coats of white wash etc complete all as specified and as directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of exterior acrylic emulsion (weather proof treatment ), in camouflaging patterns, over and including a coat of primer complete all as specified and directed.
S&F Anodised aluminium door shutter having 150mm x 44mm x 2.85 mm thick bottom rail,150 mm x 44mm x 2.85mm thick middle rail, 100mm x44mm x3 mm thick stile and top rail including necessary fitting joinery cleat, glazing packing snap beading 10 mm x 10 mm ,anodixed aluminium handle 200 mm long (02 Nos) , 3 Nos 100 mm size chromium plated butt hinges, 2 Nos 200mm size Alu tower bolt, 1x aluminium alloy, 16mm dia and 250mm long anodised, sliding door bolt with hasp, staple (bolt type), 1x double legged floor door stopper aluminum alloy body and tongue, 1 x Aluminium body hydraulically door closer , designation No-3, universal type, weight between 61 to 80 kg etc inlcuding frame of section 100 mm x 44 mm x3 mm and door shutter, top and bottom portion covered with and including 5.5mm thick tint glass ordinary quality , one mortise lock (Make: Harrison ) with shutter and fixing complete all as specified and directed.
S&F Aluminum window and ventilator shutters, sliding type with four track (two track with and including galvanised mild steel wire cloth 0.50 mm nominal dia of wire & average width of aperature 1.00 mm and fixed with tinned tacks or galvanised wire staples, two track with and including 4.8 mm thick tined glass including necessary fitting and fixture) without sash bars, aluminum sections of size 40x20x1.5 mm fixed in aluminum anodised double frame of section size 63X35X2 mm including necessary jointing cleats, glazing clips, aluminum anodised snap beading, screws, aluminium beading, pvc packing, aluminum anodised fitting and fixture including aluminium chequered grills as on aluminium windows weight not less than 1.0 kg/sqm complete all as specified and directed.
S&F 25mm dia stainless steel drappery curtain rod with finials cut to size and fixed in position including ss brackets complete all as specified and as directed.
S&F PVC solid door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, as per specification, complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement from stiles and plained colour PVC sheet to be fitted with MS frame welded/sealed to the styles & rails with suitable PVC sheet beading, and jointing together with solvent cement, supplied & fitted in the frame at site as per specification & drawings, complete as specified and directed.
S&F butt hinges, medium weight stainless steel 100mm long (ISI marked), complete all as specified and directed
S&F 200mm long aluminium anodised barrel tower bolt, of extruded section, with bright bolt and fixed complete all as specified and directed.
S&F extruded aluminum alloy handles fabricated type anodised, 150 mm size plate type complete all as specified and directed.
M&L for providing, cement concrete type B-1, 1:2:4 (20 mm graded aggregate) in lintels upto 1.5m clear span, chajja upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specifed and directed.
M&L for 20mm thick pre-polished granite stone any colour (table rubbed and polished) as in cooking platform over cement screed bed 15mm thick in cement mortar (1:4), set and jointed in neat cement slurry including pointing in white cement (1:2) and marble stone dust with admixture of pigment to match with colour and shade of granite, including making hole for LPG pipe and chamfering the corners complete all as specified and as directed.
S&F oval shaped wash hand basin, coloured with pedestal including 32mm brass chromium plated waste fittings, PVC connection 450mm long, waste pipe 32 mm dia,15 mm dia pillar tap fancy type etc. complete all as specified and directed.
S&F Vitreous china wash down water closet pan (Pedestal pattern incl one toilet paper holder, one health faucet and jet integrated controlled by two way angle valve) including plastic water closet seat white colour closed pattern with flat bottom and cover and mild steel chromium pated or aluminium/PVC hinging devices complete all as directed and specified by Engr-in-charge.
S&F Vitreous Chinaware squatting pan, orissa pattern size 580mm x 440mm with integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, complete all as specified and directed.
S&F Vitreous China gents Urinals, half stall type ( back wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, including PVC flush pipe, grating , waste coupling and union for discharge pipe, waste pipe, CP spreader etc, complete all as specified and directed.
S&F Vitreous Chinaware ladies urinal pot with integral foot rests, white, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, complete all as specified and directed.
S&F urinal partition of 8mm thick frosted glass curved shaped chrome finish of size 310x700mm complete all as specifed and directed.
S & F 10 ltr capacity PVC valves, syphonic action dual type, flushing cistren, low level, white with inlet ball valve, float and handle including brackets, complete all as specified and as directed.
S&F towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
S&F sheet glass corner set of 5.5 mm thick glass of 3 pieces as per sample approved by Engr -in-charge all as specifed and directed.
S&F soap dish, brass chromium plated 1 mm thick, complete all as specified and directed.
S&F bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F sheet glass 5.5 mm thick WHB Shelf 600 mm long and 125 mm wide as per sample approved by Engr -in-charge complete all as specifed and directed
S&F Rotational moulded polyethylene white water storage tank tripple layered white coloured, 1000 litres capacity (cylinderical vertical with closed top) hoisted with thread tank cover and fixed in position including GI tank nipple & with union(two nos each), including 20mm ball valve brass high pressure, with polythene float valve and fly nut complete all as specified and directed.
S&F Gun-metal, globe or gate valve of 20mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified and directed.
S&F stop valves, 15mm bore, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified and directed.
S&F Stop valve,15 mm cast copper alloy chromium plated fancy type with long shank &cup(concealed type) with capstan heads, screwed down, high pressure, with crutch or butterfly handle screwed for iron pipe complete all as specified and directed.
S&F PVC connection 15mm dia, 600mm long, hot water grade with brass chromium plated nuts and washers at both ends, complete all as specified.
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps & similar work etc. and cutting chases for concealed water tubing and making good, cutting exc 10cm but not exc. 20cm girth in brick walls, complete all as specified and directed.
S&F galvanized iron water tubing, ‘medium grade’ 15mm bore, with all fittings such as bend, tee, union etc., fixed complete to walls and ceilings or laid in floors, complete all as specified & directed.
S&F galvanized iron water tubing, ‘medium grade’ 20mm bore, with all fittings such as bend, tee, union etc., fixed complete to walls and ceilings or laid in floors, complete all as specified & directed.
S&F 100mm spun , Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors/wall complete all as specified and as directed.
S&F 75mm spun, Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors/wall complete all as specified and as directed.
S&F CI Bends (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore pipe, complete all as specified and as directed.
S&F CI Bends (any radius) with duck's foot or heel rest for 100mm bore pipe, complete all as specified and as directed.
S&F CI Bends (any radius) with duck's foot or heel rest for 75mm bore pipe, complete all as specified and as directed.
S&F 100mm sand cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches or T piece with oval access door complete all as specified and as directed.
S&F 75mm sand cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches or T piece with oval access door complete all as specified and as directed.
S&F Cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S&F Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S&F 100 mm dia cast iron cowl complete all as specified and directed.
S&F 125/110mm dia cast iron gully trap traps setting and jointing complete all as specified and directed.
S&F brass chromium plated grating 75/100 mm dia complete all as specified and directed.
S&F brass chromium plated grating 125mm dia with hole waste, complete all as specified and directed.
M&L for PCC(1:2:4) type B2 (40mm graded stone aggregate) filling in post holes, surface channels, drains and other similar work complete all as specified and directed.
S&F mild steel for framed structure like trusses purlins, crane gantries,post rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels, Tube, flate sections) including distance pieces, cleats etc conforming to Fe410-W (Gde-E-250) quality-A, complete all as specified and directed
S&F mild steel screws bolt (Machine made) with hexagonal or square heads at one end and screwed the other or both ends , each screwed end have one washer and one nut, dia of neck 11-15mm and length of bolt exc 5 cm and n exc 10cm long, complete all as specified and directed.
M&L for prepration of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
S&F for pre painted galvalume aluminium zinc coating having GI based corrugated steel sheets 0.50mm thick of any colour as in tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screw complete all as specified and directed by Engr-in-charge.
M&L for PCC type B-1(1:2:4), using 20mm graded crushed stone aggregate as in PCC padding on depression of roof finished even and fair without using extra cement, sides of rounded or chamfered on edges, toe beam as a bottom of fencing, complete all as specified and directed.
M&L for Water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of cleaning of concrete or plaster surface of roof and applying evenly a bitumen primer conforming to IS 3488@ 0.30Kg per sqm followed by a tack coat @ 1.2kg per Sqm using 85/25 grade industrial hot blown bitumen over it laid with APP modified polymeric water proofing membrane minimum weight 3 kg per Sqm reinforced with non-woven polyester fabric (weight not less than 150 gm per sqm) unrolled & bonded to substrate with longitudinal and end laps 100mm as per manufacturer's instruction and applying over it a tack coat using 85/25 grade industrial hot blown bitumen @ 1.2 kg sqm and as per manufacturer instruction and including taking the APP membrane will be required where the parapet wall exceed 45cm for carrying over and taking into parapet walls, cut out neatly a horizontal groove 6.5 cm deep, 7.5 cm wide section with lower edge at not less than 15 cm above the graded roof surface and groove shall be finished smooth with cement mortar 1:4 with WPC @3% by weight of cement where the parapet wall height is 45cm or less no groove will be required as the water proofing treatment will be carried over the top of parapet wall to its full thickness, complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on roof surface using water proofing compound as per manufacturer instruction surfaces finished even and smooth without using extra cement as on wall complete all as specified and directed.
M&L for 40 mm thick brick tiles laid in cement mortar and joints grouted flush in cement mortar 1:3 mixed with 5% crude oil by weight of cement on above treated surface, complete all as specified and directed.
M&L for PCC type B-0 1:2:4 using (12.5mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified & directed.
S&F peg set of six made of stainless steel, complete all as specified and directed.
M&L for Surface dressing n exc 15 cm deep in soft/ loose soil including removing bushes/ small trees etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
M&L 25 cm thick Sand cushion under floors or in foundations including consolidated with plate vibrator before and after laying of paver block including watering , ramming etc complete all as specified and directed.
M&L for 60 mm thick machine pressed precast cement concrete (M-35) factory made, interlocking paver blocks, with grey cement and pigment any shape and size as approved by GE, laid over sand cushion complete all as specified and directed by Engr-in-Charge.
M&L for 75 mm thick PCC 1:4: 8 type D-2 using 40 mm graded stone aggregate as in sub base of floor/tiles etc, complete all as specified and directed.
M&L for 75mm thick cement concrete 1:2:4, type B1, using 20mm graded crushed stone aggregate as in floor finished, surface finished even and smooth without using extra cement including making joint in blocks not more than 10 sqm and at each corner the joint shall be filled with bitumen mastic filling to full depth (comprising one part hot blown bitumen 85/25 and two part of sand), complete all as specified and directed.
Material & Labour for Painting lines, dashes, arrows, letters, etc. on roads, pavements and the like of any size with road marking paint, white or golden yellow , complete all as specified and directed.
M&L for 150mm internal diameter salt glazed stoneware drain pipe laid in trenches and joints , complete all as specified and directed.
M&L cement concrete type D2 1:4:8 (40 mm grade aggregate)as in concrete bed to drain pipes 150mm internal dia incl packing under and haunching against the pipe sides of pipe after they are laid and tested , complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM 1:4 including in circular well steining (any radius constructed from the base of curb) , complete all as specified and directed by Engr-in-charge.
M&L for 15 mm thick cement plaster in cement mortar 1:4 with water proofing compound as per manufacturer's instructions to brick or concrete surface finished even and smooth without using extra cement and using waterproofing compound all as specified (WPC shall be measured and paid separately)
Supply only integral water proofing compound
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed.
M&L for precast cement concrete type B-1 1:2:4 (20mm graded aggregate) and set in Cement Mortar (1:4) as in landings, manholes cover slabs, chajjas, shelves and similar articles including necessary form work, complete all as specified and directed.
Cutting into existing Manholes for connecting new drains , 150mm bore pipe, making good to pipes and rendering , cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete all as specified and as directed by Engr-in-Charge
Material and Labour for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed by the Engineer in Charge.
M&L for brick work with sub class 'B' bricks laid on edge in floors, bedded & jointed with cement mortar (1:6) and pointed in CM(1:3), complete all as specified and directed.
M&L for plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded aggregate) as in Channels , drains, Coping & similar works , complete all as specified and directed.
Material and labour for PCC (1;3:6) type C-2 (using 40mm graded stone aggregate) to drain pipe including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as sepcified.
Material and labour for reinforced concrete pipes 300 mm bore of pipe class NP-2 laid and jointed, with collars , complete all as specified and directed.
Extra for forming fair finished drain or surface channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint in camouflage pattern in multi shade on wall of approved colour and shade over one coat of primer, complete all as specified and directed.
Excavation in post holes(or similar holes) each in not exc. 0.50 cum getting out, returning,filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm in soft loose soil watering and removing surplus soil out of defence land and making good surface, complete all as specified & directed.
S&F Mild steel angle iron fencing posts and struts in fencing including necessary cutting , drilling , welding etc and bending to swan neck shape as required and drilling holes notching for wire etc conforming to Fe-410-0, complete all as specified and directed by Engr-in-Charge.
S&F Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to posts of any type including securing or tying at crossing with and provision of GI wire staples or steel pins etc complete all as specified and directed by Engr-in-Charge.
S&F MS chain link fencing 10 guage thick galvanised steel wire and 75mm x 75mm size mesh fixed to steel fencing post by nut & bolts etc including provision of binding wire complete all as specified and directed by Engineer-in-Charge .
S&F Mild Steel work in flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engrneer-in-charge
S&F mild steel round bars 10 mm dia Fe-410-w (Gde- E-250) and over cut ot length bent to shape including cranking bending etc , complete all as specified and directed.
M & L for preparing new surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
M&L for Point wiring (concealed) complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn through in including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5 Sq mm copper earth continuity wire connected to earth dolly complete for the following , complete all as specified and directed by Engineer-in-Charge.
One light /fan/exhaust fan point controlled by one switch.
One switch socket outlet 3 pin 5 amp on same board.
One switch socket outlet 3 pin 5 amp on independent board.
All as per item No 131 above but 2.5 sqmm cable size for one 3 pin socket outlet, 15 Amps on independent board.
All as per item No 131 above but 4 sqmm cable size for one 3 pin socket outlet, 15 Amps on independent board.(AC/Geyser)
S&F 20/22 Watt LED Luminarie decorative box type fitting inlcuding LED tube with blue coloured end caps pre wired for LED tube energy saving with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 2000 total lumen. The lamp shall be 1200 mm length with G13 base. The 20/22 Watt system shall be operating at 220-240V AC supply having internal driver, IP 20, surge protection 2 KV, ambient temperature -20 to 45 degree C, freequency 50 to 60 Hz, The system efficacy must be between 80-100 lumen/watt, with 70% lumen maintenance up to 40000 burning Hrs with uniform visually comfortable light output at 150 degree beam spread, CRI minimum 80, PF should be greater than 0.95, THD <10%. individual LED,s should not be visible for glare free output colour temperature 6500k filled on & including 2 Nos PVC block of suitable & connecting up to tube light fitting with connecting up with copper 3 core flexible white cord of min size of 0.5 sqmm, complete all as specefied and directed.
S & F Road way LED 25 Watt with new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver complete with all accessories suitable for and including lamp cool white including 1.5 sqmm single core cable from junction box to fitting passed through pole for making necessary electric connections. Make : Crompton cat part No- CG-LSTS-25-CDL-M or equivalent makes as specified in Appendix 'B' List of Makes.
S&F for Sub main wiring (concealed ) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sqmm copper earth continuity wire, accessories and connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge. Note :- 2 runs of 4 Sqmm, 1 run of PVC conduit & 1 run of 4 Sqmm cable shall be measured as single unit length.
S&F Ceiling rose, surface bakelite, 65 x 50 mm, three terminals, complete all as specified and directed by Engineer-in-Charge.
S&F Step 0-4, modular type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 100 Watts humfree single pole, complete all as specified and directed by Engineer-in-Charge.
S&F Socket modular type single pole one way 6 Amps 2/3 pin 240 volts, complete all as specified and directed by Engineer-in-Charge.
S&F Switch modular type, single pole one way 6 Amps, 250 volts AC suitable for modular switch boxes without indicator, complete all as specified and directed by Engineer-in-Charge.
S&F Socket modular type 16 Amps, 2/3 pin combine, 2 module,240 volts , complete all as specified and directed by Engineer-in-Charge.
S&F Switch modular type 16 Amps, one way 1 module,240 volts, complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 10/20 amps , 240 Volts, complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 4 way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal enclosures for DB's for incorporating MCBs, TPN, 4 way, IP-43 double glazed door with 200 amps rated busbar, 415 volts, as per IS-8623, complete all as specified and directed by Engineer-in-Charge.
S&F MCB four poles, 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 32 amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc, complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 6 to 32 amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
M&L Earthing complete with G I earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 4 dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. including replacment of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
S&F exhaust fan with louvers of size 300mm sweep, 900 RPM 230 Volts single phase AC Supply with bolts, nuts and washers, suitably embedded in the wall making suitable opening and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 from ceiling rose to exhaust fan for giving conection completed all as specifed and directed. Make:- HAVELLS/CROMPTON/KHAITAN/USHA
S&F ceiling fan 1200mm sweep complete 230 volts(single phase) and provisioning of flexible copper cord of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and directed by Engr-in-Charge. Make:- HAVELLS/CROMPTON/KHAITAN/USHA
S&F bracket for street light fittings made out of 40 mm dia GI pipe of medium grade 1.2 mtr long each bent to required shape & size and fixed to pole with and including flat iron clamps 02 Nos and fasteber Nos 04 made out of 40x6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of silver paint over a coat of red oxide primer and fittings bracket to street light fittings complete with , complete all as specified and directed by Engineer-in-Charge.
Filling of dry sand under and around LT cable to provide sand cushsioning 8cm before laying of cables and 15cm after laying of cables in sub station ducts/trenches complete all as specifed and directed.
Brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cales abutting each other complete all as specifed and directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core, complete all as specified and directed.
Contract Amount shall be derived on serial page No 16 of tender documents.
IMPERIAL ENGINEERS
H S BUILDERS
Aggarwal brothers and company
PACHR BUILDERS
M/S GODARA CONSTRUCTION CO.
MSR INFRATECH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .