Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.2 L+₹2.4 L (11.4%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹23.8 L+₹3.0 L (14.5%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹24.2 L+₹3.4 L (16.5%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹24.8 L+₹4.0 L (19.0%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
20 Jan 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Provision of certain special repair works under GE Utilities Udhampur
2019_MES_307849_1
GE/U-46/2019-20
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹53,000
Yes
12 Mar 2020
19 Dec 2019
21 Jan 2020
19 Dec 2019
20 Jan 2020
6 Jan 2020
Amount
Taking out the existing unserviceable rusted LT panel board alongwith busbar, MCCBs etc of any size/capacity including disconnection, breaking PCC foundation etc and disposed off complete all as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel Board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50 x 50 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments: -
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel Board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50 x 50 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel Board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50 x 50 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm , front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel Board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50 x 50 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Supply, installation, testing and commissioning of outdoor type,weather proof, LT Panel made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50 x 50 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 blocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
S&F in replacement of MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement of MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 250 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement of MCCB 4 pole, Ics=100%Icu- 25/26 KA, 415 Volts, 200 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement of MCCB 4 pole, Ics=100%Icu- 25/26 KA, 415 Volts, 160 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement of MCCB 4 pole, Ics=100%Icu- 16/18 KA, 415 Volts, 100 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
Taking out unserviceable LT UG cable of size 16 sqmm 2 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 12 but LT cable of size 16 sqmm 4 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 12 but LT cable of size 25 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 12 but LT cable of size 35 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 12 but LT cable of size 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 12 but LT cable of size 70 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 12 but LT cable of size 95 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 12 but LT cable of size 120 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 12 but LT cable of size 150 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 12 but LT cable of size 185 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Supply, Laying, fixing jointing and Testing in replacement LT Cross Linked Polythene Insulated (XLPE insulated) galvanized steel strip armoured electric cable of size 16 sqmm 2 core, 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, along the poles or passing through pipes or laid under floor or along walls complete all as specified and directed by Engr-in-charge. (Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately)
Description all as per serial Item No 22 but LT cable of size 16 sqmm 4 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 22 but LT cable of size 25 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 22 but LT cable of size 35 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 22 but LT cable of size 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 22 but LT cable of size 70 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 22 but LT cable of size 95 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 22 but LT cable of size 120 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 22 but LT cable of size 150 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 22 but LT cable of size 185 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
S&F tubing 'light grade' of size 80 mm bore galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 32 but 50 mm bore complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 32 but 100 mm bore complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, foundations of poles/stays etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning to UG cable laid in trenches with clean dry river sand 8 cm below & 15 cm above the cable & punned down to 18 cm thickness complete all as specified and directed by Engr-in-Charge. (For payment purpose 18 cm thickness shall measured)
M&L for providing new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed by Engr-in-charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
M&L for road cutting for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 25 to 35 sqmm 3.5 core LT UG Cable complete all as specified and directed by Engr-in-charge. Make: M-Seal /Denson or equivalent make
S&F straight through joint kit, heat shrinkable type suitable for 50 sqmm 3.5 core LT UG Cable complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 70 sqmm 3.5 core LT UG Cable complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 95 sqmm 3.5 core LT UG Cable complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 120 to 150 sqmm 3.5 core LT UG Cable complete all as specified and directed by Engr-in-charge.
S&F straight through joint kit, heat shrinkable type suitable for 185 sqmm 3.5 core LT UG Cable complete all as specified and directed by Engr-in-charge.
M&L in replacement aluminium thimble cable (Lugs) suitable for Cable of size 25 Sqmm complete all as specified and directed. Make: Dowells/Eqvt
Description all as per serial Item No 48 but thimbles of size 35 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 48 but thimbles of size 50 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 48 but thimbles of size 70 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 48 but thimbles of size 95 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 48 but thimbles of size 120 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 48 but thimbles of size 150 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial Item No 48 but thimbles of size 185 Sqmm complete all as specified and directed by Engr-in-charge.
M&L in replacement of PVC insulated multi stranded aluminum conductor PVC cable sheathed of size 10 Sqmm twin core and making connections with overhead lines/UG Cable complete all as specified and directed by Engr-in-charge.
M/S AG ELECTRICALS
PREM NATH KHAJURIA AND SONS
vijay kumar gupta and co
FANGALIA TRADERS
MOHAN LAL AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .