Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 CrAccepted-AOC | ₹29.8 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹38.1 CrRejected-Finance | ₹38.1 Cr | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹38.4 CrRejected-Finance A 2 45 JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | ₹38.4 Cr | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹38.6 CrRejected-Finance 19 PARKDRIVE MALIBU TOWN SECTOR 47 SOHNA ROAD GURGAON HARYANA 122001 | GURGAON | GURGAON | HARYANA | 122001 | ₹38.6 Cr | L4 | Rejected-Finance NOT LOWEST |
| 5 | Rejected-Technical 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | - | - | Rejected-Technical NOT RECOMMENDED SINCE THE FIRM DOES NOT MEET THE PQC AS PER NIT |
| Sl No | Description | Qty | Unit | ASHOK KUMAR MITTAL L1 | Gawar Construction Limited L4 | JYOTI ENTERPRISES L2 | MAHINDER PAL CONSTRUCTIONS PVT LTD L3 |
|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE `A' PART - I (Building / Structure Works) is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only. | |||||||
| 1.01 | Design and construction of Sqn Leader & above accn in five storey (G+4 storey) having 2 DU per floor including accn for servent quarters and lift well complete all as specified and as shown on drawings. | 1 | Each Block | 2,00,00,000 ₹2 Cr | 4,77,00,000 ₹4.8 Cr | 5,67,03,703 ₹5.7 Cr | 4,71,12,000 ₹4.7 Cr |
| 1.02 | Design and construction of Flt Lt accn in two stoery (G+1 storey) having 2 DU per floor including accn for servent quarters complete all as specified and as shown on drawings. | 2 | Each Block | 50,00,000 ₹1 Cr | 1,16,00,000 ₹2.3 Cr | 99,98,040 ₹2.0 Cr | 1,06,36,800 ₹2.1 Cr |
| 1.03 | Design and construction of Warrant rank accn in seven storey (G+6 storey) having 2 DU per floor including lift well complete all as specified and as shown on drawings. | 1 | Each Block | 1,60,00,000 ₹1.6 Cr | 4,95,00,000 ₹5.0 Cr | 3,64,29,554 ₹3.6 Cr | 3,96,03,200 ₹4.0 Cr |
| 1.04 | Design and construction of Sgt & below accn in seven storey (G+6 storey) having 4 DU per floor including lift wells complete all as specified and as shown on drawings. | 2 | Each Block | 2,10,00,000 ₹4.2 Cr | 6,40,00,000 ₹12.8 Cr | 5,25,52,134 ₹10.5 Cr | 6,47,92,000 ₹13.0 Cr |
| 1.05 | Design and construction of Type III Civilian Md accn three storey (G+2 storey) having 2 DU per floor in permanent accn complete all as specified and shown on drawings. | 1 | Each Block | 1,00,00,000 ₹1 Cr | 1,14,00,000 ₹1.1 Cr | 1,01,23,200 ₹1.0 Cr | 1,03,10,400 ₹1.0 Cr |
| 1.06 | Design and construction of Type II Civilian Md accn three storey (G+2 storey) having 2 DU per floor in permanent accn complete all as specified and shown on drawings. | 1 | Each Block | 1,10,00,000 ₹1.1 Cr | 1,08,00,000 ₹1.1 Cr | 88,57,800 ₹88.6 L | 90,43,200 ₹90.4 L |
| 1.07 | Design and construction of Garrages including ramp for SQN LDR and above Accn complete all as specified and shown on drawings. | 2 | Each Block | 50,00,000 ₹1 Cr | 2,50,000 ₹5 L | 14,78,249 ₹29.6 L | 13,68,000 ₹27.4 L |
| 1.08 | Design and construction of Garrages including ramp for FLT LT Accn complete all as specified and shown on drawings. | 2 | Each Block | 57,00,000 ₹1.1 Cr | 2,50,000 ₹5 L | 11,99,024 ₹24.0 L | 10,94,400 ₹21.9 L |
| 1.09 | Design and construction of car and scooter Garrages including ramp for Warrant rank Accn complete all as specified and shown on drawings. | 2 | Each Block | 57,00,000 ₹1.1 Cr | 2,50,000 ₹5 L | 15,43,949 ₹30.9 L | 14,59,200 ₹29.2 L |
Tender Value
₹32.6 Cr
EMD Value
₹15 L
Closing Date
15 Dec 2025, 6:00 pmClosed
HQ CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM, DELHI CANTT
PROVN OF DEFICIENT 100 DUs AT AF STN SARSAWA PHASE I SCH A PART I FOR BLDGS WKS ON EPC MODE
2025_MES_728399_2
CEWAC/SAR/T-19/2025-26
Open Tender
Civil Works
1530 days
GE (AF) SARSAWA
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (AF) SARSAWA
₹15 L
Yes
HQ CE (AF) WAC PALAM DELHI CANTT
23 Jan 2026
24 Nov 2025
17 Dec 2025
24 Nov 2025
15 Dec 2025
8 Dec 2025
2 Dec 2025
Amount
SCHEDULE `A' PART - I (Building / Structure Works) is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only.
Design and construction of Sqn Leader & above accn in five storey (G+4 storey) having 2 DU per floor including accn for servent quarters and lift well complete all as specified and as shown on drawings.
Design and construction of Flt Lt accn in two stoery (G+1 storey) having 2 DU per floor including accn for servent quarters complete all as specified and as shown on drawings.
Design and construction of Warrant rank accn in seven storey (G+6 storey) having 2 DU per floor including lift well complete all as specified and as shown on drawings.
Design and construction of Sgt & below accn in seven storey (G+6 storey) having 4 DU per floor including lift wells complete all as specified and as shown on drawings.
Design and construction of Type III Civilian Md accn three storey (G+2 storey) having 2 DU per floor in permanent accn complete all as specified and shown on drawings.
Design and construction of Type II Civilian Md accn three storey (G+2 storey) having 2 DU per floor in permanent accn complete all as specified and shown on drawings.
Design and construction of Garrages including ramp for SQN LDR and above Accn complete all as specified and shown on drawings.
Design and construction of Garrages including ramp for FLT LT Accn complete all as specified and shown on drawings.
Design and construction of car and scooter Garrages including ramp for Warrant rank Accn complete all as specified and shown on drawings.
Design and construction of car and scooter Garrages including ramp for SGTand below Accn complete all as specified and shown on drawings.
Design and construction of Garrages including ramp for Type III Civillian Accn complete all as specified and shown on drawings.
Design and construction of Garrages including ramp for Type II Civillian Accn complete all as specified and shown on drawings.
Design and construction of Garbage bin with permanent specifications all as specified and as shown on drawings.
Design and construction of Service Toilet complete all as specified and shown on drawings.
Design and construction of UG Sump of capacity 20000 Gallon (free board of 0.50 M) with permanent specifications including necessary earthwork, foundation PCC, RCC M-30 (Design Mix), steel reinforcement, PCC plinth protection and all necessary connected items all as specified and shown on drawings.
Design and construction of UG Sump of capacity 25000 Litres (free board of 0.50 M) with permanent specifications including necessary earthwork, foundation PCC, RCC M-30 (Design Mix), steel reinforcement, PCC plinth protection and all necessary connected items all as specified and shown on drawings.
NOTE: Schedule ‘A’ Part II to XIII under Ser No 2.01 to 2.11 are Prepriced by MES.
Lump sum price worked out by the Contractor for “ SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part-II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part-III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part-IV
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-V
Lump sum price worked out by the Contractor for “AREA DRAINAGE WORK ” as listed in Schedule ‘A’ Part-VI
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part-VIII
Lump sum price worked out by the Contractor for “ROAD, PATH AND HARDSTANDING ” as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the Contractor for “FIRE ALARM & FIRE FIGHTING WORK ” as listed in Schedule ‘A’ Part-X
Lump sum price worked out by the Contractor for “LIFT WORK ” as listed in Schedule ‘A’ Part-XI
Lump sum price worked out by the Contractor for “LIGHTNENING PROTECTION ” as listed in Schedule ‘A’ Part-XII
Lump sum price worked out by the Contractor for “VERMICOMPOST ” as listed in Schedule ‘A’ Part-XIII
SCHEDULE `A' PART - XIV MISC ITEMS (B/R & E/M) is not prepriced by MES and prepriced rates indicated as 0.00 under column 5 signifies this fact only.
“INTERNAL ELECTRIC SUPPLY"
S&F sheet metal enclosures Vertical type doubledoor (VTPN) MCCB incomer, with Acrilic Door, cement spill protector For MCCB Triple pole and neutral, 8 ways, IP-43 protection, with 100 Amps rated bus bar breaking capacity 25KA, 415 Volts complete all as specified and directed by Engineer-in-Charge.
S&F telephone jack complete all as specified and directed
S&F T V Jack complete all as specified and directed.
“EXTERNAL WATER SUPPLY"
S&F openwell submersible pumpset having discharge and head not less than 80 LPM X 30 mtr head and outlet dia of 40mm bore with chrome steel impeller and strainer, including motor of suitable capacity to run on 230 volts, 1 phase, 50 Hz cycles A/C power supply including lifting chain, cable, starters, panel, etc. complete with other accessories as required.
S&F openwell submersible pumpset having discharge and head not less than 260 LPM X 33 mtr head and outlet dia of 80mm bore with chrome steel impeller and strainer, including motor of suitable capacity to run on 415 volts, 3 phase, 50 Hz cycles A/C power supply including lifting chain, cable, starters, panel, etc. complete with other accessories as required.
M&L for construction of brick masonry valve pit of size 90×90×90 cm (internal dimension) with MS top cover of 3mm thick sheet, fixed on frame made out of angle iron 40×40×6mm thick with locking arrangement including two coats of synthetic enamel paint over a coat of zinc chrome primer to MS sheet internally and externally & iron surface, brick work in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally & externally), 150 thick plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate for base, 100mm thick PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate for coping, two coats of white wash internally after preparation the surface complete all as specified and as shown on drawings.
M&L for construction of brick masonry valve pit of size 60×60×60 cm (internal dimension) with MS top cover of 3mm thick sheet, fixed on frame made out of angle iron 40×40×6mm thick with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primer to MS sheet internally and externally & iron surface, brick work in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally & externally), 150 thick plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate for base, 100mm thick PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate for coping, two coats of white wash internally after preparation the surface complete all as specified and as shown on drawings.
“EXTERNAL ELECTRIC SUPPLY"
Shifting of transformer 11/0.433 KV, 160 KVA rating from E/M store yard to proposed location for Sqn Leader and above area, using hydra & tractor trolley complete as specified and directed.
M&L for Construction of platform for transformer of size 2.5 x 2.5 x 1.5 mtr with following specifications:-a) Earth work in soft/loose soil b) 15 cm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as lean concrete in foundation c) Brick work with sub class ‘B’ brick built in cement mortar 1:4. Space between walls filled with aggregates duly rammed of size 45–60 mm d) 75 mm thick PCC 1:2:4 type B1 using 20 mm graded aggregate over brick platform e) Chain link on fencing post of size 40 x 40 x 6 mm of height 1.80 mtr at 2 mtr c/c around brick platform including excavation and earth work in soft/loose soil and angle iron PCC 1:2:4 of size 60 x 60 x 60 cm f) Chain link fencing of height 1.80 mtr made out of GI wire not less than 3 mm and pitch not more than 75 mm g) Angle iron gate using 40 x 40 x 6 mm angle iron 2 x 1.5 m with vertical flat 25 x 6 mm @ 10 cm (±10%) including hinges & locking arrangement h) 15 mm thick plaster in CM 1:6 on brick masonry platform j) All exposed surfaces of steel work shall be given two coats of synthetic enamel paint over a coat of red oxide primer k) Stair case of brick masonry for easy access to the plate.
Supply and fix Lightning arrester, expulsion type, transmission class, having discharge capacity 10KA, suitable for HT 11 KV complete all as specified and directed.
Note for item no 3.10 to 3.18: (i) All MCCB shall be with adjustable Thermal magnetic setting (TMD). (ii) The board shall be epoxy polyester powder coated with structure siemens gray shade RAL-7035. (iii) Sheet metal works shall be processed with 7 tank process i.e. degreasing, water rinsing, activation, phosphating, water rinsing, passivation and water drying. (iv) Busbar shall be of electrolytic grade aluminium and shall be insulated with Red, Yellow, Blue and Black colour heat shrinkable PVC Sleeves. (v) Earth bus of aluminium shall run throughout the length of the panel at the bottom. (vi) Each feeder shall be provided with individual inscription plate made out of black anodized Al/polycarbonate sheet with engraved/painted letters. (vii) Power switches/MCCB’s will be provided with door operating mechanism & door interlock and padlocking feature. (viii) Danger notice board with conventional skull & cross bones symbol shall be provided on front & rear side. (ix) All incoming & outgoing feeder shall be provided with gland plates for cable exit of cable. (x) All MCCB’s to be provided with external rotary operating handle. (xi) All type test certificate and design verification with switch gears (ACB & MCCB) as per. (xii) All panels shall be procured from CPRI manufacturere. (xiii) The panel shall be inspected by rep of CWE before dispatch to the site.
Supply & fixing Hot dipped galvanized octagonal pole of 8 mtr height having top dia 70mm, bottom dia 130mm, sheet thickness 3mm, base plate of size 220mm×200mm×12mm, foundation bolt 4×M20×750 (Noxidaxlength) with PCD 225mm, complete with in-built junction box with cable termination arrangement, 1mtr long single arm bracket of hot dipped GI including necessary foundation as per manufacturer’s design & specifications. (Note: Excavation & RCC foundation shall be measured and paid separately).
Supply & Fix non-metallic junction box made out of thermoplastic of size 250×250×160 mm for street light poles with connector for connection incoming and outgoing cables including provision of 01 No MCB SP 2.5 Amp to control the pole light circuit including 04 × aluminium bus bars strips 150×30×3mm of size mounting on the insulator and fixing clamp made of FI 25×3 mm with back strip with suitable nut, bolts, washers including double compression cable glands for incoming and outgoing cables complete as specified and directed.
Supply & Fix PVC insulated copper wire 1.5 sqmm 3 core for street light fitting drawn through pole from junction box to fitting complete as specified and directed.
Supply & Fix LED Aviation light 10 W, IP 65 comprising of aluminium housing with polycarbonate enclosure complete.
S&F MCCB 125 Amps 4 pole 16 KA duly enclosed in outdoor type sheet metal enclosure made out of 3.15mm thick CRCA sheet provided with 02 Nos mounting legs of angle iron of size 40x40x5mm, 450mm long each duly grounted in PCC (1:4:8) type D2 complete with cable gland for entry and exit point of cable complete. (Loc: Flt ltn qtr tapping point)
S&F MCCB 250 Amps 4 pole 25 KA duly enclosed in outdoor type sheet metal encloser made out of 3.15mm thick CRCA sheet provided with 02 Nos mounting legs of angle iron of size 40 x40x 5mm, 450mm long each duly grounted in PCC (1:4:8) type D2 complete with cable gland for entry and exit point of cable complete (Loc: Sqn Ldr near tapping point)
Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 16 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed. (for Aviation obstruction light)
Supply and fixing HDPE DWC pipe having OD/ID of size 40/32mm as per IS 16205 (Part 24) for electric cable protection across road/hardstanding/along poles complete with coupler all as specified and as directed.
Supply and fixing HDPE DWC pipe having OD/ID of size 63/50mm as per IS 16205 (Part 24) for electric cable protection across road/hardstanding/along poles complete with coupler all as specified and as directed.
Supply and fixing HDPE DWC pipe having OD/ID of size 110/95mm as per IS 16205 (Part 24) for electric cable protection across road/hardstanding/along poles complete with coupler all as specified and as directed.
Boring of holes under road, pavement, hard standing, size upto 150mm for passing of cable/pipe using necessary T&P complete all as specified and directed.
“FIRE ALARM & FIRE FIGHTING WORK ”
Supply and fix Fire alarm control panel zone card Conventional type complete all as specified and directed
Supply and fix conventional manual call point resettable type complete all as specified and directed
Supply and fix conventional sounder/ Hooter complete all as specified and directed
Supply and fix Repeater control panel with suitable for 40 manual call point complete all as specified and directed
Supply, installation, testing and commissioning of Electric Terrace fire control panel metal clad cubical type suitable for 415 V AC three phase 4 wire 50Hz supply system. The panel should be suitable for automatic operation for the fire pump having discharge 900 LPM and Head 36 mtr. The panel shall be completely compartmentalised and complete with relays, contractors, starters, Aluminium bus bar, designation lables as per requirement, Continuous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/bottom cable gland plate for incoming and outgoing cable entries complete all as specified and directed Note: (a) Complete system shall be installed by a firm dealing with such system or any authorized rep of firm. (b) Any minor items required for successful operation of the system deemed to be included in the overall rates quoted.
Supply, installation, testing and commissioning of Electric Terrace fire control panel metal clad cubical type suitable for 415 V AC three phase 4 wire 50Hz supply system. The panel should be suitable for automatic operation for the fire pump having discharge 450 LPM and Head 36 mtr. The panel shall be completely compartmentalised and complete with relays, contractors, starters, Aluminium bus bar, designation lables as per requirement, Continuous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/bottom cable gland plate for incoming and outgoing cable entries complete all as specified and directed Note: (a) Complete system shall be installed by a firm dealing with such system or any authorized rep of firm. (b) Any minor items required for successful operation of the system deemed to be included in the overall rates quoted.
Supply and fix hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle, MS sheet 2 mm thickness complete all as specified and directed.
Supply and fix MS cabinet (approx 750mm x 600mm x 450mm) to enclose fire brigade inlet connections fabricated from 16 gauge sheet with full fr.ont glass door and locking arrangement painted and mounted on masonry platform complete all as specified and directed
S&F Exit Light self contained 6W luminaire with flush mounting frame, sign label, fluorescent tube Li battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required complete all as specified and directed.
“DG SET ”
Supply, installation, commissioning and testing silent diesel engine driven Gen set 125 KVA capacity 415 volts, 3 phase, 4 wire acoustic weather proof enclosure as per latest CPCB-IV norms and noise level shall not exceeding 75 db at a distance of 1 metre, Engine as per IS-10001/1002 and alternator as per IS-13364 installed on PCC platform as per manufacturer's recommendation complet comprising the following components: (a) Diesel Engine:- Diesel engine develping suitable BHP, 1500 RPM water cooled engine inclusive of the following standard accessories (i) Spider coupling guard (ii) Fly wheel (iii) Fly wheel housing complete with starter gear ring and coupling (iv) Fuel pipe (v) Air cleaner (vi) Fuel & Lub oil filter (vii) by pass filter (viii) Lub oil pump (ix) Electric Starter 12 Volts DC (x) Battery charging generatory (DC alternator) (xi) Industrial silencer (xii) Lub oil cooler (xili) flexible pipe for sinencer (xiv) DC voltmeter (xv) lub oil pressure gauge, lub oil/water temperature guage (xvi) Speedo meter and engine running hours meter (xvi) Display for fault (xvii) Governor (xviii) Battery as per manufacturer recommendation- 01 No (b) ALTERNATOR: Alternator suitable for continous operation generation 125 KVA at 1500 RPM 415 V at NTP, 0.8 power factor 3 phase, 50Hz, self excited and regulated with ball/roller bearing confirming to IS -4722 (c) AMF PANEL (in built in canopy): AMF panel, factory made, indoor, cubical type, front open able fabricated out of CRCA sheet 2 mm thick complete with 4-pole Aluminium Bus, MCCB, Power contractor, Relay, battery charging system and protections as per OEM specifications.
All as per item No 3.43 & 3.44 above, but capacity of DG set shall be 40 KVA with alternator suitable for continuous operation generation 40KVA.
PHASE II: Commence after completion of work of Phase I
Manning & Operation of following lifts installed at 100 DU’s bldgs in three shift each of 08 Hrs per day including Sunday and holiday, providing rescue to the trapped person, attending day to day maintenance and maintaining the machine/equipments in clean and tidy condition during the operation period. (i) 08 passengers (G+6) – 03 Nos (ii) 13 passengers (G+6) – 03 Nos (iii) 13 passengers (G+4) – 01 Nos Tradesman to be deployed: One lift operator/technician (skilled) per shift
PHASE III: Commence after completion of work of Phase II
Manning & Operation of following lifts installed at 100 DU’s bldgs in three shift each of 08 Hrs per day including Sunday and holiday, providing rescue to the trapped person, attending day to day maintenance and maintaining the machine/equipments in clean and tidy condition during the operation period. (i) 08 passengers (G+6) – 03 Nos (ii) 13 passengers (G+6) – 03 Nos (iii) 13 passengers (G+4) – 01 Nos Tradesman to be deployed: One lift operator/technician (skilled) per shift
PHASE IV: Commence after completion of work of Phase III
Manning & Operation of following lifts installed at 100 DU’s bldgs in three shift each of 08 Hrs per day including Sunday and holiday, providing rescue to the trapped person, attending day to day maintenance and maintaining the machine/equipments in clean and tidy condition during the operation period. (i) 08 passengers (G+6) – 03 Nos (ii) 13 passengers (G+6) – 03 Nos (iii) 13 passengers (G+4) – 01 Nos Tradesman to be deployed: One lift operator/technician (skilled) per shift
Comprehensive, preventive and periodical maintenance of following electrically operated passenger lifts with electric power operated doors, auto door electric levelling device complete with ARD facility installed at 100 DU’s building to be maintained round the clock as described here-in after in reliable, safe and efficient operating condition by regularly overhauling, servicing & to adjust the mechanical and electrical driving equipment, governor, sleeve shaft assembly bearing/contacts & governor jaws, limit switches (car & hall mechanical buttons, car & hall position indicators, car direction indicators), and all other car and landing signal fixtures, deflectors, car and counter weight guide rails and buffers, equipment and carry out planned maintenance in a systematic and controlled manner using techniques and expertise consultancy; including replacement of spares parts as and when required all as directed and specified to the entire satisfaction of GE. (i) 08 passengers (G+6) – 03 Nos (ii) 13 passengers (G+6) – 03 Nos (iii) 13 passengers (G+4) – 01 Nos Note: AMC to be carried out through OEM only. MOU to this effect shall be submitted by the contractor to Engr-in-charge before commencement of work.
JYOTI ENTERPRISES (BID ID -3496505)
MAHINDER PAL CONSTRUCTIONS PVT LTD (BID ID -3497476)
Gawar Construction Limited (BID ID -3496856)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 6.34 MB
TENDER.pdf
Tender Documents • 17.06 MB
BOQ_830068.xls
BOQ • 0.88 MB
Soil.pdf
Additional Documents • 23.89 MB
DRGS.pdf
Additional Documents • 17.93 MB
Download all tender documents and submit your bid