| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC LOWEST QUOTED | |
| 2 | L2₹5.9 L+₹49,360 (9.11%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L2 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 3 | L3₹6.4 L+₹96,655 (17.8%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 4 | L4₹6.9 L+₹1.5 L (26.9%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L4 | Rejected-Finance OTHER THAN LOWEST QUOTED | |
| 5 | L5₹7.9 L+₹2.4 L (45.0%)Rejected-Finance MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance OTHER THAN LOWEST QUOTED |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
6 Oct 2020, 6:00 pmClosed
GE AF UDHAMPUR
GE AF UDHAMPUR
Repairs and maintenance of earthing, lightening arrestor, smoke detector and other misc works at AF Station Nathatop under GE (AF) Udhampur
2020_MES_376190_1
GE/AFU-41/2020-21
Open Tender
Miscellaneous Works
Item Rate
334 days
AF STATION NATHATOP
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹30,000
Yes
19 Oct 2020
9 Sept 2020
8 Oct 2020
9 Sept 2020
6 Oct 2020
22 Sept 2020
Amount
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete with fittings such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCBs, Main switches from control board and making good disturbed surfaces of walls, floor to match with existing specifications complete all as specified.
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Switch modular type, 16/20 Amp, one way, one module conforming to IS-3854 complete all as specified and as directed.
Socket shuttered outlet 2-in-1, 6/16 Amp modular type, 2 modules complete all as specified and as directed.
S&F in repairs electric bell, AC 230 volt, single pole, multi musical type complete all as specified and as directed.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2.5.00 sqmm (nominal area) 1100 volts grade cable as earth wire,including suitable size of steel conduit drawn through concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 2.5.00 sqmm main cable and one RM of 2.5.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
S&F in repairs fully addressable intelegent optical/ionization heat and smoke detectors analogue,light scattingtype using apluse internal infra red LED and silicon photo diode .it should be microprocessor based type and suitable to operare on voitage 9-33 volts DC and operating teparture -20 degree centigrade to 40 degree centigrade as per IS: 11360 complete all as specified and as directed by Engineer-in-Charge. Make- HONEYWELL /EDWARD/ NOTIFIR/SYSDTEM SENSER
S&F in repairs UL approved addressable manual call point re-settable made out of cast iron or CRCA sheet with normally closed push button station placed in off condation by glass ( To be break in case of fire ) complete all as specified and as directed by Engineer-in-Charge.Make- AGNI/SURAKSHA/MINIMAX/FIREX
S&F in repairs UL approved addressable electronic hooter/ loop power sounder cum strobe complete all as specified and as directed by Engineer-in-Charge . . Make- AGNI/ MINIMAX / AHUJA / PHILIPS / MELTRON
S&F in repairs Fire Alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors & modules upto 200 detector including the following technical specifications and all specified and directed Engr-in-Charge. (a) Primary power supply : 220v +/- 10% AC, 50Hz(b) Standby power supply : 24 V DC (2 Nos of 12V, 7 SMF batteries )(c) Battery charging voltage ; 27.5 +/- 1V(d) Battery caharging current : 500 mA (max)(e) Pragrammable relay contact : 3 Sets.(f) Relay Contact Rating : 2 Amps 30 V DC(g) Operating temp :- 100C to +550C(h) Humidity : 0 to 95% RH(j) Internal wiring complete two core (k)1000 event history log(l) Built in battery Charger(m) Contamination level alart for maintenance (n) Detection sensitivity adjustments (from panel)(o) Alarm verification feature (p) upto 127 devices per loop. (q) two levels password protection MAKE:HONEYWELL/EDWARDS/NOTIFIRE/SYSTEM SENSER
MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 8 way SPN with 200 Amp rated bus bar 230 volt AC supply including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make:CAT PART NO:507682 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
Sheet metal enclosures for DBs SPN 2 way (when MCBs to be used) flush mounted including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / Schneider
S&F in repairs Air termination, single pointed, copper rod 12mm dia and 300mm long,complete all as specified and directed
MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make:CAT PART NO:408620 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
Earthing complete with copper earth plate electrode of size 90cm x 60cm x 5mm buried directly in ground vertically at a depth not less than 4.50 metre below normal ground level with top edge of earth plate at a depth not less than 3.5 metre below normal gorund level surrounded from all sides by 15 cm thick and packed alternate layer of common salt and charcoal and a top layer of copper sulphate 150mm thick all as specified and as directed in drawing No CEAF/SK-60/2017 Dt 24.4.17 including bringing of mother soil from outside for filling holes, including Copper strip of size 32 x 6mm by means of nuts, bolts and check nuts, washers of copper up to main board/test point or as required including necessary excavation and earth work in any type of soil so as to achieve earth resistance below 3 Ohms including excavation of polypit chamber with polyplastic pit cover (cost of polypit chamber with polyplastic pit cover shall be deemed to be included in the rate quoted) complete all as specified and as directed by Engineer-in-Charge including dismantling of existing unserviceable earthing. Notes : (a) Copper strip beyond test point shall be measured and paid for separately. (b) Earthing resistance result shall be less than 3 Ω .If the result comes more than 3 Ω the contractor shall carry out the earthing at separate location/site given by the Engr-in-Charge after taking out of earth electrode without any extra cost to the deptt. (c) Test point terminal block shall be measured and paid for separately. (d) The contractor's quoted rates shall be deemed to include for dismantling/taking down of old unserviceable earthing of any type and making good the disturbed surfaces and nothing extra shall be admissible on this account. (e) Any other fittings/fixtures if technically required for achieving desired results (if not included above) shall be provided by the contractor without any extra cost to the Govt. (f) If mother soil is not available then mother soil wil be provided by contractor from outside source without any extra cost to the Govt.
Earth continuity conductor or main earthing lead 20x3 mm Copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, In Repair,complete all as specified & directed by Engr-in-charge
Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws complete all as specified and directed including taking down old unserviceable.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq .mm 2 core nominal cross section stranded conductor in service connections ,including taking down old unsereviceable ,complete all as specified and directed by Engr-in-charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq .mm 2 core nominal cross section stranded conductor in service connections ,including taking down old unsereviceable ,complete all as specified and directed by Engr-in-charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq .mm 2 core nominal cross section stranded conductor in service connections ,including taking down old unsereviceable ,complete all as specified and directed by Engr-in-charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq .mm 2 core nominal cross section stranded conductor in service connections ,including taking down old unsereviceable ,complete all as specified and directed by Engr-in-charge.
Marking the earthing pit with white / coloured hylam sheet/ perplex sheet 3mm thick of size 200x 150mm fixed with MS angle iron 20x20x4mm and 0.75 m long including painting with synthetic enamelled paint two coats over a coat of red oxide primer fixed by means of 2 nos nuts/ bolts/ washers of with colour code as per direction by Engr-in-charge, suitable size and grouting the marker nearer to the earth pit in PCC type B-1, 1:2:4 of size 0.15x0.15x0.15m including necessary earth work, marker shall be having the following letters (letters of size 25mm) complete all as specified and directed by Engineer-in-Charge: EARTH PIT NO_________________________ CHEMICAL/ COPPER/ GI_________________ EQUIPMENT/ BUILDING CONNECTED________________________ DATE OF TEST :____________________________ EARTH RESISTANCE_______________________
Supply & fixing heavy duty insulator (alongwith nuts & bolts) to be fixed on wall/ roof for the support of copper earth strip all as specified and directed
MOHAN LAL AND SONS
DAVINDER SINGH
R K BUILDERS
RANBIR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .